IS-44299-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Find the appropriate threaded holes on mounng
strap[A]. Assemble mounng screws[B] into threaded
holes.
2) Aach mounng strap to outlet box[C] using the
strap mounng screws[D]. The mounng strap can be
adjusted to suit posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture[E] to ceiling, carefully passing mounng
screws through holes in canopy. NOTE: Be certain wires
do not get pinched between canopy and ceiling.
6) Use knobs[G] and lockwashers[H] to secure canopy.
Tighten to secure.
7) Place the glass globe[J] over the installed bulb and
secure in place using the 3 screws[F] and washers[I].
CAUTION: Do not overghten.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Mounting
Strap
[B] Mounting
Screws
[C] Outlet Box
[D] Strap
Mounting
Screws
[E] Fixture
[F] Screws
[G] Knobs
[H] Lockwashers
[I] Washers
[J] Glass Globe
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.