UF-80 RS232C PC-side FlowChart
2
UF-80 RS232C Cable Connection
UF80-side PC-side
2
3
5
2
3
5
Send 6-byte to MICOM
[start_code(0xB0)+command code
(4-byte)+stop_code(0xBF)]
Receive 6-byte from MICOM
(1st Rx data==0xB0)
&(6th Rx data==0xBF)
(2nd Rx data==0x80)
Basic Flow
End
Application Flow
Send Message State Check Command
[0xB0 0x64 0x00 0x00 0x00 0xBF]
Receive 6-byte from MICOM
(2nd Rx data == 0x80)
Send User (AWC, etc) Command
- BaudRate: 9600bps
- Parity Bit: No Parity
- Stop Bit Length: 1-bit
- Character Length: 8-bit
- Start Code: 0xB0
- Stop Code: 0xBF
- Command Code: 4-byte
(Note1 2nd Rx data == 0x80)
What the 2nd-Rx-data ("ACK data") is not 0x80
means that the system is doing other operation.
(Check up page 6)
With the command "Message-Status", you can
check up current status of the system and send
the user command. (AWC, etc)
RS232C Command Code (UF-80)
3
English French German Italian Spanish
AWC 0 x 01 0 x 00 0 x 05 0 x 00 0 x 01 "ACK data" 0 x 05 0 x 00
AF 0 x 02 0 x 00 0 x 05 0 x 00 0 x 02 "ACK data" 0 x 05 0 x 00
Lamp ON 0 x 03 0 x 00 0 x 05 0 x 00 0 x 03 "ACK data" 0 x 05 0 x 00
Lamp OFF 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Internal 0 x 04 0 x 00 0 x 05 0 x 00 0 x 04 "ACK data" 0 x 05 0 x 00
External 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Aperture ON 0 x 09 0 x 00 0 x 05 0 x 00 0 x 09 "ACK data" 0 x 05 0 x 00
Aperture OFF 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
FREQ 75Hz 0 x 0A 0 x 00 0 x 05 0 x 00 0 x 0A "ACK data" 0 x 05 0 x 00
FREQ 60Hz 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Power ON 0 x 0F 0 x 00 0 x 05 0 x 00 0 x 0F "ACK data" 0 x 05 0 x 00
Power OFF 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Rotate OFF 0 x 00 0 x 05 0 x 00 "ACK data" 0 x 05 0 x 00
Rotate 90° 0 x 11 0 x 00 0 x 08 0 x 00 0 x 11 "ACK data" 0 x 08 0 x 00
Rotate 180° 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Rotate 360° 0 x 00 0 x 0D 0 x 00 "ACK data" 0 x 0D 0 x 00
1st 2nd 3rd 4th
PC Transmit Data to MICOM
Command Remark
PC Receive Data from MICOM
1st 2nd 3rd 4th
RS232C Command Code (UF-80)
4
Freeze ON 0 x 12 0 x 00 0 x 05 0 x 00 0 x 12 "ACK data" 0 x 05 0 x 00
Freeze OFF 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Image Save 0 x 13 0 x 00 Number 0 x 00 0 x 13 "ACK data" Number 0 x 00 Range:"1~8"
Image Recall 0 x 14 0 x 00 Number 0 x 00 0 x 14 "ACK data" Number 0 x 00 Range:"1~8"
(1)
Image Divide 0 x 15 0 x 00 Number 0 x 00 0 x 15 "ACK data" Number 0 x 00 Range:"1~9"
Image Shift 0 x 16 0 x 00 0 x 05 0 x 00 0 x 16 "ACK data" 0 x 05 0 x 00
Preset Save 0 x 17 0 x 00 Number 0 x 00 0 x 17 "ACK data" Number 0 x 00 Range:"1~4"
Preset Exe 0 x 18 0 x 00 Number 0 x 00 0 x 18 "ACK data" Number 0 x 00
Recall, divide,
3x3 multi-screen
0 x1F 0 x 00 0 x 05 0 x 00 0 x 1F "ACK data" 0 x 05 0 x 00
Cancel
Iris Up 0 x 21 0 x 00 0 x 05 0 x 00 0 x 21 "ACK data" 0 x 05 0 x 00
Iris Down 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Red Up 0 x 23 0 x 00 0 x 05 0 x 00 0 x 23 "ACK data" 0 x 05 0 x 00
Red Down 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Blue Up 0 x 24 0 x 00 0 x 05 0 x 00 0 x 24 "ACK data" 0 x 05 0 x 00
Blue Down 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
1st 2nd 3rd 4th
PC Transmit Data to MICOM
Command Remark
PC Receive Data from MICOM
1st 2nd 3rd 4th
[Note 1] Transmitting number "9" in image divide command, the system executes 3X3 multi-screen mode.
RS232C Command Code (UF-80)
5
English French German Italian Spanish
Focus FAR 0 x 25 0 x 00 0 x 05 0 x 00 0 x 25 "ACK data" 0 x 05 0 x 00
Focus NEAR 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Zoom Tele 0 x 26 0 x 00 0 x 05 0 x 00 0 x 26 "ACK data" 0 x 05 0 x 00
Zoom Wide 0 x 00 0 x 0A 0 x 00 "ACK data" 0 x 0A 0 x 00
Iris Target 0 x 41 0 x 00 0 x 00 "data" 0 x 41 "ACK data" 0 x 00 "data"
Range: "1~120"
Red Target 0 x 43 0 x 00 0 x 00 "data" 0 x 43 "ACK data" 0 x 00 "data"
Range: "1~200"
Blue Target 0 x 44 0 x 00 0 x 00 "data" 0 x 44 "ACK data" 0 x 00 "data"
Range: "1~200"
Focus Target 0 x 45 0 x 00 "MSB data" "LSB data" 0 x 45 "ACK data" "MSB data" "LSB data"
(1)
Range: "0~2225"
Zoom Target 0 x 46 0 x 00 "MSB data" "LSB data" 0 x 46 "ACK data" "MSB data" "LSB data"
Range: "0~1904"
Focus/Zoom 0 x 47 0 x 05
"zoom MSB" "zoom LSB"
0 x 47 "ACK data"
"zoom MSB" "zoom LSB"
(1)
Focus: "0~2225"
concurrent Target
0 x 0A
"focus MSB" "focus LSB"
"ACK data"
"focus MSB" "focus LSB"
Zoom: "0~1904"
(1)
Drive Stop 0 x 2F 0 x 00 0 x 05 0 x 00 0 x 2D "ACK data" 0 x 05 0 x 00
1st 2nd 3rd 4th
PC Transmit Data to MICOM
Command Remark
PC Receive Data from MICOM
1st 2nd 3rd 4th
[Note 1] Depending of the zoom amount, the range of focus data will be changed. You can figure it out to see
page 4. ("Focus-Status[Max]", "Focus-Status[Min]")
[Note 2] Above 10 Command (Iris up/down ,Red up/down, Blue up/down, Focus far/near, Zoom tele/wide) will
go to all the way once you execute it.
"Drive Stop" can stop those command in certain point that you want.
RS232C Command Code (UF-80)
6
Set-Status(Normal)
0 x 61 0 x 00 0 x 00 0 x 00 0 x 61 "ACK data"
Status(MSB) Status(LSB)
Set-Status(Digital)
0 x 62 0 x 00 0 x 00 0 x 00 0 x 62 "ACK data"
Status(MSB) Status(LSB)
Message-Status
0 x 64 0 x 00 0 x 00 0 x 00 0 x 64 "ACK data"
Status(MSB) Status(LSB)
Iris-Status
0 x 65 0 x 00 0 x 00 0 x 00 0 x 65 "ACK data" 0 x 00 Status
Range:"1~120"
Red-Status 0 x 67 0 x 00 0 x 00 0 x 00 0 x 67 "ACK data" 0 x 00 Status
Range:"1~200"
Blue-Status 0 x 68 0 x 00 0 x 00 0 x 00 0 x 68 "ACK data" 0 x 00 Status
Range:"1~200"
Zoom-Status 0 x 69 0 x 00 0 x 00 0 x 00 0 x 69 "ACK data"
Status(MSB) Status(LSB)
Range:"0~1904"
Focus-Status 0 x 6A 0 x 00 0 x 00 0 x 00 0 x 6A "ACK data"
Status(MSB) Status(LSB)
Range:"0~2225"
(1)
Focus-Status(Max)
0 x 6B 0 x 00 0 x 05 0 x 00 0 x 6B "ACK data"
Status(MSB) Status(LSB)
Range:"648~2225"
(1)
Focus-Status(Min)
0 x 00 0 x 0A 0 x 00 "ACK data"
Status(MSB) Status(LSB)
Range:"0~1383
"
1st 2nd 3rd 4th
PC Transmit Data to MICOM
Command Remark
PC Receive Data from MICOM
1st 2nd 3rd 4th
[Note 1] This command returns focus maximum/minimum data at current zoom position.
Bit definition
of Status
represents
Page 5, 6, 7
RS232C COMMAND CODE (UF-80)
7
(0,0,0,0,1): Set is executing command by panel-key
(0,0,0,1,0): Set is executing command by remocon
(0,0,1,0,0): Set is executing command by RS232C
(0,1,0,0,0): Set is executing command by USB
(1,0,0,0,0): Set is executing command by MOUSE
Acknowledgement Bit ("0": no-ACK, "1": ACK)
76543210
(0,0,0,0,1): Set is executing command by panel-key
(0,0,0,1,0): Set is executing command by remocon
(0,0,1,0,0): Set is executing command by RS232C
(0,1,0,0,0): Set is executing command by USB
(1,0,0,0,0): Set is executing command by MOUSE
(0,0,1): Set is executing AF command
(0,1,1): Set is executing Preset-Exe command
(1,0,0): Set is executing Image-Save command
(1,0,1): Set is executing Image-Rotate command
(1,1,0): Set is executing Frequency command
76543210
Bit Definition of "ACK data"
Status Bit Definition by Message-Status Command
English French German Italian Spanish
RS232C Command Code (UF-80)
8
(0,0,0): internal input
(1,0,1): NO SYNC(EXT) (1,1,1): external input
(0): lamp OFF (1): lamp ON
(0): System Power OFF (1): System Power ON
(0): Aperture ON (1): Aperture OFF
(0): Frequency 75Hz (1): Frequency 60Hz
Status Bit Definition by Set-Status Command
- LSB 8bit
- MSB 8bit
76543210
76543210
RS232C COMMAND CODE (UF-80)
9
Divide position information
(0,0):shift1 (0,1):shift2 (1,0):shift3
Divide or Recall number information
(0,0,0,1): number1 (0,0,1,0): number2
. .
. .
(0,1,1,1): number7 (1,0,0,0): number8
Status Bit Definition by Set-Status(Digital) Command
- LSB 8bit
76543210
(0): image divide OFF (1): image divide ON
(0): 3X3 multi-screen OFF (1): 3X3 multi-screen ON
(0): image freeze OFF (1): image freeze ON
(0): image recall OFF (1): image recall ON
(0,0):image rotate OFF (0,1):image rotate 90°
(1,0):image rotate 180° (1,1):image rotate 270°
- MSB 8bit
76543210
English French German Italian Spanish
Memo
10
English French German Italian Spanish
Organigramme côté PC UF-80 RS232C
2
Câble de branchement UF-80 RS232C
Côté UF80 Côté PC
2
3
5
2
3
5
Envoie de 6-bits à MICOM
[code de démarrage(0xB0)+code de commande
(4-bits)+code darrêt(0xBF)]
Reçoit 6 bits de MICOM
Non
Non
Oui
Oui
Non
Oui
(1st Rx data==0xB0)
&(6th Rx data==0xBF)
(2nd Rx data==0x80)
Flux de base
Fin
Flux dapplication
Envoie message état contrôle commande
[0xB0 0x64 0x00 0x00 0x00 0xBF]
Reçoit 6 bits de MICOM
(2nd Rx data == 0x80)
Fin
Envoie commande utilisateur (AWC, etc)
- Débit en bauds : 9600bps
- Bit de parité : Aucune parité
- Arrêt longueur de bit : 1-bit
- Longueur de caractère : 8-bit
- Code de démarrage : 0xB0
- Code darrêt : 0xBF
- Code de commande : 4-byte
(Remarque 1 2nd Rx data== 0x80)
2nd-Rx-data ("ACK data") nest pas 0x80
signifie que le système effectue une autre
opération. (Vérifiez page 8)
A laide de la commande "Message-Status"
vérifiez l’état actuel du système et envoyez la
commande utilisateur. (AWC, etc)
Code commande RS232C (UF-80)
3
English French German Italian Spanish
AWC 0 x 01 0 x 00 0 x 05 0 x 00 0 x 01
"Données ACK"
0 x 05 0 x 00
AF 0 x 02 0 x 00 0 x 05 0 x 00 0 x 02
"Données ACK"
0 x 05 0 x 00
Lamp ON 0 x 03 0 x 00 0 x 05 0 x 00 0 x 03
"Données ACK"
0 x 05 0 x 00
Lamp OFF 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Internal 0 x 04 0 x 00 0 x 05 0 x 00 0 x 04
"Données ACK"
0 x 05 0 x 00
External 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Aperture ON 0 x 09 0 x 00 0 x 05 0 x 00 0 x 09
"Données ACK"
0 x 05 0 x 00
Aperture OFF 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
FREQ 75Hz 0 x 0A 0 x 00 0 x 05 0 x 00 0 x 0A
"Données ACK"
0 x 05 0 x 00
FREQ 60Hz 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Power ON 0 x 0F 0 x 00 0 x 05 0 x 00 0 x 0F
"Données ACK"
0 x 05 0 x 00
Power OFF 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Rotate OFF 0 x 00 0 x 05 0 x 00
"Données ACK"
0 x 05 0 x 00
Rotate 90°0 x 11 0 x 00 0 x 08 0 x 00 0 x 11
"Données ACK"
0 x 08 0 x 00
Rotate 180°0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Rotate 360°0 x 00 0 x 0D 0 x 00
"Données ACK"
0 x 0D 0 x 00
1er 2ème 3ème 4ème
Transmission de données du PC vers MICOM
Command
Remarque
Réception de données de MICOM vers le PC
1er 2ème 3ème 4ème
RS232C Command Code (UF-80)
4
Freeze ON 0 x 12 0 x 00 0 x 05 0 x 00 0 x 12
"Données ACK"
0 x 05 0 x 00
Freeze OFF 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Image Save 0 x 13 0 x 00 Numéro 0 x 00 0 x 13
"Données ACK"
Numéro 0 x 00 Plage:"1~8"
Image Recall 0 x 14 0 x 00 Numéro 0 x 00 0 x 14
"Données ACK"
Numéro 0 x 00 Plage:"1~8"
(1)
Image Divide 0 x 15 0 x 00 Numéro 0 x 00 0 x 15
"Données ACK"
Numéro 0 x 00 Plage:"1~9"
Image Shift 0 x 16 0 x 00 0 x 05 0 x 00 0 x 16
"Données ACK"
0 x 05 0 x 00
Preset Save 0 x 17 0 x 00 Numéro 0 x 00 0 x 17
"Données ACK"
Numéro 0 x 00 Plage:"1~4"
Preset Exe 0 x 18 0 x 00 Numéro 0 x 00 0 x 18
"Données ACK"
Numéro 0 x 00
Recall, divide,
3x3 multi-screen
0 x1F 0 x 00 0 x 05 0 x 00 0 x 1F
"Données ACK"
0 x 05 0 x 00
Cancel
Iris Up 0 x 21 0 x 00 0 x 05 0 x 00 0 x 21
"Données ACK"
0 x 05 0 x 00
Iris Down 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Red Up 0 x 23 0 x 00 0 x 05 0 x 00 0 x 23
"Données ACK"
0 x 05 0 x 00
Red Down 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Blue Up 0 x 24 0 x 00 0 x 05 0 x 00 0 x 24
"Données ACK"
0 x 05 0 x 00
Blue Down 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
1er 2ème 3ème 4ème
Transmission de données du PC vers MICOM
Command
REMARQUE
Réception de données de MICOM vers le PC
1er 2ème 3ème 4ème
[Remarque 1] En transmettant le numéro "9" en commande division dimage, le système exécute le mode
multi écran 3X3.
RS232C Command Code (UF-80)
5
English French German Italian Spanish
Focus FAR 0 x 25 0 x 00 0 x 05 0 x 00 0 x 25
"Données ACK"
0 x 05 0 x 00
Focus NEAR 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Zoom Tele 0 x 26 0 x 00 0 x 05 0 x 00 0 x 26
"Données ACK"
0 x 05 0 x 00
Zoom Wide 0 x 00 0 x 0A 0 x 00
"Données ACK"
0 x 0A 0 x 00
Iris Target 0 x 41 0 x 00 0 x 00 "données0 x 41
"Données ACK"
0 x 00 "données
Plage: "1~120"
Red Target 0 x 43 0 x 00 0 x 00 "données0 x 43
"Données ACK"
0 x 00 "données
Plage: "1~200"
Blue Target 0 x 44 0 x 00 0 x 00 "données0 x 44 "
"Données ACK"
0 x 00 "données
Plage: "1~200"
Focus Target 0 x 45 0 x 00
"données MSB” “données LSB
0 x 45
"Données ACK" "données MSB” “données LSB
(1)
Plage: "0~2225"
Zoom Target 0 x 46 0 x 00
"données MSB” “données LSB
0 x 46
"Données ACK" "données MSB” “données LSB
Plage: "0~1904"
Focus/Zoom 0 x 47 0 x 05
"données MSB” “données LSB
0 x 47
"Données ACK" zoom MSB” “zoom LSB
(1)
Mise au point
:
"0~2225"
concurrent Target
0 x 0A
"données MSB” “données LSB"Données ACK"
"Mise au point MSB" "Mise au point LSB"
Zoom: "0~1904"
(1)
Drive Stop 0 x 2F 0 x 00 0 x 05 0 x 00 0 x 2D
"Données ACK"
0 x 05 0 x 00
1er 2ème 3ème 4ème
Transmission de données du PC vers MICOM
Command
Remarque
Réception de données de MICOM vers le PC
1er 2ème 3ème 4ème
[Remarque 1] Selon le zoom, la plage des données de la mise au point vont changer. Vous pouvez consulter
la page 6. ("Etat mise au point[Max]", "Etat mise au point [Min]")
[Remarque 2] Au delà, la commande 10 (Diaphragme haut/bas, Rouge haut/bas, Bleu haut/bas, Mise au
point proche/éloigné, Zoom téléobjectif/grand angle) sera effectuée entièrement lorsque vous
lexécutez.
" Arrêt lecteur" permet darrêter les commandes à l'endroit de votre choix.
RS232C Command Code (UF-80)
6
Set-Status(Normal)
0 x 61 0 x 00 0 x 00 0 x 00 0 x 61
"données ACK"
Etat (MSB) Etat (LSB)
Set-Status(Digital)
0 x 62 0 x 00 0 x 00 0 x 00 0 x 62
"données ACK"
Etat (MSB) Etat (LSB)
Message-Status
0 x 64 0 x 00 0 x 00 0 x 00 0 x 64
"données ACK"
Etat (MSB) Etat (LSB)
Iris-Status
0 x 65 0 x 00 0 x 00 0 x 00 0 x 65
"données ACK"
0 x 00
Etat
Plage:"1~120"
Red-Status 0 x 67 0 x 00 0 x 00 0 x 00 0 x 67
"données ACK"
0 x 00
Etat
Plage:"1~200"
Blue-Status 0 x 68 0 x 00 0 x 00 0 x 00 0 x 68
"données ACK"
0 x 00
Etat
Plage:"1~200"
Zoom-Status 0 x 69 0 x 00 0 x 00 0 x 00 0 x 69
"données ACK"
Etat (MSB) Etat (LSB)
Plage:"0~1904"
Focus-Status 0 x 6A 0 x 00 0 x 00 0 x 00 0 x 6A
"données ACK"
Etat (MSB) Etat (LSB)
Plage:"0~2225"
(1)
Focus-Status(Max)
0 x 6B 0 x 00 0 x 05 0 x 00 0 x 6B
"données ACK"
Etat (MSB) Etat (LSB)
Plage:"648~2225"
(1)
Focus-Status(Min)
0 x 00 0 x 0A 0 x 00
"données ACK"
Etat (MSB) Etat (LSB)
Plage:"0~1383
"
1er 2ème 3ème 4ème
Transmission de données du PC vers MICOM
Command
Remarque
Réception de données de MICOM vers le PC
1er 2ème 3ème 4ème
[Remarque 1] Cette commande permet de ramener les données maximum/minimum de la mise au point à la
position du zoom actuel.
La définition
du bit de l’état
représente les
pages 7, 8, 9
RS232C COMMAND CODE (UF-80)
7
(0,0,0,0,1): Le paramétrage est effectué par une commande d'une
(0,0,0,1,0): Le paramétrage est effectué par une commande de
(0,0,1,0,0): Le paramétrage est effectué par la commande de RS232C
(0,1,0,0,0): Le paramétrage est effectué par une commande USB
(1,0,0,0,0): Le paramétrage est effectué par une commande de la SOURIS
Bit de réception ("0": no-ACK, "1": ACK)
touche du panneau
la commande à distance
d'une touche du panneau
de la commande à distanc
de RS232C
USB
de la SOURIS
76543210
(0,0,0,0,1): Le paramétrage est effectué par une commande
(0,0,0,1,0): Le paramétrage est effectué par une commande
(0,0,1,0,0): Le paramétrage est effectué par la commande
(0,1,0,0,0): Le paramétrage est effectué par une commande
(1,0,0,0,0): Le paramétrage est effectué par une commande
(0,0,1): Le paramétrage est effectué par la commande AF
(0,1,1): Le paramétrage est effectué par la commande Preset-Exe
(1,0,0): Le paramétrage est effectué par la commande Image-Save
(1,0,1): Le paramétrage est effectué par la commande Image-Rotate
(1,1,0): Le paramétrage est effectué par la commande Frequency
76543210
Définition de bit des "données ACK"
Bit d’état Definition par Message-Commande état
English French German Italian Spanish
RS232C Command Code (UF-80)
8
(0,0,0) : entrée interne
(1,0,1) : PAS DE SYNC(EXT)
(1,1,1) : entrée externe
(0): lampe éteinte (1): lampe allumée
(0) : Système éteint (1): Système allumé
(0) : Ouverture activée (1): Ouverture désactivée
(0) : Fréquence 75Hz (1): Fréquence 60Hz
Définition du bit d’état par paramétrage-Commande état
- LSB 8bit
- MSB 8bit
76543210
76543210
RS232C COMMAND CODE (UF-80)
9
Information relatives à la position de division
(0,0) :déplacer 1 (0,1) : déplacer 2 (1,0) : déplacer 3
Informations relatives au numéro de division ou de rappel
(0,0,0,1) : numéro 1 (0,0,1,0) : numéro 2
(0,1,1,1) : numéro 7 (1,0,0,0) : numéro 8
Bit d’état définition par paramétrage-Commande état (Numérique)
- LSB 8bit
76543210
(0) : division dimage désactivée (1) : division dimage activée
(0) : multi écran 3X3 désactivé (1) : multi écran 3X3 activé
(0): image figée désactivée (1): image figée activée
(0): rappel dimage désactivé (1): rappel dimage activé
(0,0) :rotation dimage désactivée (0,1) :rotation dimage de 90
(1,0) :rotation dimage de 180 (1,1) :rotation dimage de 270
- MSB 8bit
76543210
English French German Italian Spanish
Memo
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61

Samsung UF-80 XGA Le manuel du propriétaire

Taper
Le manuel du propriétaire