Portable Airconditioner - English manual 7
EN
IMPORTANT SAFEGUARDS (5/6)
48. No ignition sources:
No person carrying out work in relation to a refrigeration system
which involves exposing any pipe work that contains or has contained
ammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of re or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufciently far
away from the site of installation, repairing, removing and disposal,
during which ammable refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no ammable
hazards or ignition risks. “No Smoking” signs shall be displayed.
49. Ventilated area:
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
50. Checks to the refrigeration equipment:
Where electrical components are being changed, they shall be
t for the purpose and to the correct specication. At all times the
manufacturer’s maintenance and service guidelines shall be followed. If
in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using ammable
refrigerants:
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and
are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected;
– refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which may
corrode refrigerant containing components, unless the components
are constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.