12. If the heater was installed inappropriately or was connected unhomogeneously with the local elec-
trical supply cable, high transfer resistances may occur, which lead to overheang of the device. For
the heang system and many custom applicaons the heaters were equipped with a NTC temperature
control and an addional latching temperature limiter.
Ordinarily possible overhaeng due to inappropriate installaon is protected by the NTC temperature
control and the latching temperature limiter. If overheang of a carbon heang element occur due to
interlinkage of mounng and installaon mistakes, the carbon laments inside of the quarz tubes will
fuse and safely disconnect the current ow. Even aer a mechanical break of the quarz tubes, the car-
bon heang spirals will not work any longer. Besides the n front screen of the SPOT heaters and the
glass ceramic, high temperature resistant front screen of the VISION heaters provide best protecon of
the installed carbon heang elements.
Funconal descripon of the NTC temperature control: If the system temperature of the electronical
control exceeds 217.4 °F, the upper heang element will shut o temporary by default to avoid over-
haeng of the electronical parts. Aer a short me the heang element will switch on automacally
again. The self-controlled shut o of the heater will take place only, if the heat dissipaon inside the
device is inappropriate, if the heat radiaon is interfered or if the ambience temperetaure is way too
high. Apart from that the NTC temperature control supports energy sangs, if the ambient temperatu-
res are too high and the highest heang level of the heang unit is not necessary.
Funconal descripon of the latching temperature limiter: If the NTC temperature control is not wor-
king against expectaons, the latching temperature limiter will shut down the lower heang element
permanently, unl the heater is shut o totally by hand. Aer cooling down (warm to the touch) and
xing the inappropriate heat dissipaon inside the device and/or the interferred heat radiaon the
heater can be switched on again. If the lower heang element shuts down once more, a system mal-
funcon or a heat dissipaon inside the device or an interference of the heat radiaon or an error in
the electrical installaon may be the reason. If a system malfuncon inside the device causes the shut
down, the heater must be repaired by a professional technician; please contact your dealer immedi-
ately. If a wrong cable connecon causes the shut down, this has to be checked and xed through a
professional electrician on the spot.
Installaon and connecng regulaons with tested and approved luster terminals are part of the
delivered equipment.
13. The radiant heater must not be installed directly below a power source/socket. The sides of the
unit must be at least 7.87 inch from the nearest power source. Sockets/power sources must be freely
accessible at all mes and comply with the following specicaons: 220–240 V AC ~, 50/60 Hz, 16 A
with 16 A fuse. No other loads may be connected to this power source.
14. The radiant heater must must not be installed in rooms where there is high humidity (bathroom,
spa, pool etc.) in close vicinity to bathtubes, showers or pools. The distance to the bathtub or shower
must be at least 39.37 inch and the distance to the pool at least 78.74 inch. A person standing in the
bathtube, shower or pool should never reach the switch or controller of the heater. If the HEATSCOPE®
is installed in such an environment with high humidity, the switches or other operang components
must be posioned in such a way that they cannot be touched by persons who are in direct contact
with water. Bathroom heaters must not be operated with a separate automac thermostat or mer.
When a radiant heater is installed in a bathroom, the CE standard requires that at least one heang
element visibly „glows“ as soon as the unit is switched on.