1. Unplug all appliances or equipment on the circuit being tested.
2. Plug the GT-10 into any standard 120 V AC receptacle (NEMA 5-15R).
3. Compare the illuminated lamps on the GT-10 to the code key located
on the product or in the table above.
Note: If the LEDs indicate anything other than “Correct Wiring”,
have the wiring verified by a qualified electrician.
Note: The GT-10 is not a comprehensive diagnostic instrument. The
GT-10 is a simple instrument designed to detect nearly all, probable
and common, improper wiring conditions. It will not detect a
combination of defects. It will not indicate the quality of ground or
reversal of grounded and grounding conductors. It will not detect two
hot wires in a circuit. Circuit capacitance may indicate continuity in an
open circuit. Failure to unplug appliances or equipment on the circuit
being tested can cause erroneous readings.
Hot / Ground Reverse
Hot / Neutral Reverse
Correct
O
p
en Groun
d
Open Neutral
Open Hot
FA
U
L
T
Hot and ground contacts interchanged
Hot and neutral contacts interchanged
Receptacle is wired correctly
G
round contact not connected
Neutral contact not connected
Hot contact not connected
REA
SO
N F
O
R WIRIN
G
FA
U
L
T
INDI
C
AT
OR
KEY:
Indicator Lit
Indicator Not Lit
Hot Contact
(
black wire
)
Neutral Contact
(
white wire
)
Ground Contact
(
green or uninsulated wire
)
Typical 3-Wire NEMA 5-15R Receptacle
(
polarized
)
Electric shock hazard:
Contact with live circuits could result in severe injury
or death.
GT-10 Outlet Circuit Tester
Lifetime Limited Warranty
Greenlee Textron Inc. warrants to the original purchaser of these goods for use that these
products will be free from defects in workmanship and material for their useful life, excepting
normal wear and abuse. This warranty is subject to the same terms and conditions contained in
Greenlee Textron Inc.’s standard one-year limited warranty.
For all Test Instrument repairs, contact Customer Service at 800-435-0786 and request a Return
Authorization. An Approved Authorization including shipping label and instructions will be sent.
For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote
is available upon request.
Note: Prior to returning any test instrument, please check replaceable batteries or make sure the
battery is at full charge.
Garantía limitada válida durante la vida útil del producto
Greenlee Textron Inc. le garantiza al comprador original de estos bienes de uso, que los mismos
estarán libres de defectos de materiales y fabricación durante su vida útil; excepto en el caso de
que sean maltratados o hayan sufrido el deterioro normal. Esta garantía está sujeta a los
mismos términos y condiciones de la garantía estándar limitada válida por un año, otorgada por
Greenlee Textron Inc.
Para reparaciones de todo instrumento de verificación, comuníquese con el Departamento de
Servicio al Cliente al 800-435-0786 y solicite una autorización de devolución. Se le enviará una
Autorización Aprobada incluyendo una etiqueta de envío e instrucciones.
Puede obtener, previa solicitud, una cotización de precios de reparación para aquellos artículos
que no están cubiertos bajo esta garantía (los que se han dejado caer o han sido maltratados).
Aviso: Antes de devolver un instrumento de verificación, revise si las pilas están bajas y es
necesario reemplazarlas.
Garantie à vie limitée
La société Greenlee Textron Inc. garantit à l’acheteur d’origine de ces produits que ces derniers
ne comportent aucun défaut d’exécution ou de matériau pour la durée de leur vie utile, sauf
l’usure normale. Cette garantie est assujettie aux mêmes conditions que celles contenues dans
les modalités et conditions de la garantie limitée standard d’un an de Greenlee Textron Inc.
Pour toutes les réparations d’instruments de mesure, appeler le service après vente au
800 435-0786 et demander une autorisation de retour. Une autorisation approuvée, incluant
une étiquette d’expédition et des instructions sera envoyée.
Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil tombe, s’il est
soumis à un usage abusif, etc.), une soumission pour le prix de réparation sera présentée sur
demande.
Remarque : Avant de renvoyer un appareil de mesure, vérifier les piles remplaçables ou
s’assurer que la pile est chargée au complet.
For technical assistance: 800-435-0786
Greenlee / A Textron Company
4455 Boeing Drive, Rockford, IL 61109-2988 USA
Customer Service (International): 815-397-7070 • Fax: 815-397-9247
Customer Service (North America): 800-435-0786
USA Fax: 800-451-2632, 815-397-1865 • Canada Fax: 800-524-2853
Greenlee Textron Inc. is a subsidiary of Textron Inc.
www.greenlee.com
999 6763.4 REV 1 © 2005 Greenlee Textron Inc. 7/05
Instrucciones
1. Desenchufe todo aparato o equipo conectado al circuito que se está
verificando.
2. Enchufe la unidad GT-10 a cualquier receptáculo estándar de
120V CA (NEMA 5-15R).
3. Compare las lámparas iluminadas en la unidad GT-10 con la clave de
códigos en el producto o en la tabla que aparece arriba.
Nota: Si los diodos emisores de luz (LED) indican cualquier otra
cosa excepto que el cableado es correcto “Correct Wiring”,
contrate a un electricista profesional a fin de que revise el
cableado.
Nota: La unidad GT-10 no es un instrumento de diagnóstico
exhaustivo. La unidad GT-10 es un simple instrumento que detecta
casi todas las condiciones de cableado incorrecto comunes posibles.
No detectará una combinación de defectos. No indicará la calidad de
las conexiones a la tierra, conexiones a tierra invertidas o conductores
a tierra. No detectará dos cables energizados en un mismo circuito. La
capacitancia del circuito podría indicar continuidad en un circuito
abierto. De no desenchufarse todos los aparatos y equipos conectados
al circuito que se está verificando, podrían ocasionarse lecturas
incorrectas.
Verificador de Circuitos
de Tomacorrientes GT-10
Mode d’emploi
1. Débrancher tous les appareils ou équipements sur le circuit à vérifier.
2. Brancher le GT-10 dans n’importe quelle prise de courant standard
(NEMA 5-15R) de 120 V c.a.
3. Comparer les voyants allumés sur le GT-10 au code de clé situé sur le
produit ou dans le tableau ci-dessus.
Remarque : Si les DEL indiquent autre chose que « Correct
Wiring » (câblage correct), faire vérifier le câblage par un
électricien qualifié.
Remarque : Le GT-10 n’est pas un instrument de diagnostic complet.
Le GT-10 est un instrument simple, conçu pour détecter presque
toutes les conditions probables et courantes de câblage incorrect. Il ne
détecte pas une combinaison de défauts. Il n’indique pas la qualité de
la mise à la terre ou l’inversion des conducteurs mis à la terre ou de
mise à la terre. Il ne détecte pas deux câbles actifs sur un circuit. La
capacité du circuit pourrait indiquer la continuité dans un circuit
ouvert. Le fait de ne pas débrancher les appareils ou l’équipement
branchés sur le circuit peut produire des lectures erronées.
Vérificateur de prise
de courant GT-10
Energizado/Tierra invertida
Energizado/Neutro invertido
Correcto
Tierra abierta
Neutro abierto
Energizado abierto
FALLA
Contactos energizado y a tierra intercambiados
Contactos energizado y neutro intercambiados
El receptáculo está cableado correctamente
Contacto a tierra no conectado
Contacto neutro no conectado
Contacto energizado no conectado
RAZÓN DE LA FALLA DE CABLEADO
INDICADOR
LEYENDA:
Indicador iluminado Indicador no iluminado
Contacto energizado (alambre negro)
Contacto neutro (cable blanco)
Contacto a tierra (cable verde o sin forro aislante)
Receptáculo NEMA 5-15R trifilar típico (polarizado)
Chaud / Mise à la terre inversée
Chaud / Neutre inversé
Correct
Mise à la terre ouverte
Ouvert neutre
Ouvert chaud
DÉFAUT
Contacts chaud et de mise à la terre remplacés l’un par l’autre
Contacts chaud et neutre remplacés l’un par l’autre
Les fils de la prise sont installés correctement
Contact de mise à la terre non branché
Contact neutre non branché
Contact chaud non branché
RAISON DU DÉFAUT DE CÂBLAGE
INDICATEUR
RÉFÉRENCE :
Voyant allumé Voyant éteint
Contact chaud (fil noir)
Contact neutre (fil blanc)
Contact de mise à la terre (vert ou fil non isolé)
Réceptacle NEMA 5-15R à 3 fils type (polarisé)
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar
graves lesiones o incluso la muerte.
Risques de décharge électrique :
Un contact avec des circuits sous tension pourrait
entraîner des blessures graves, voire mortelles.
  • Page 1 1
  • Page 2 2

Greenlee GT-10 Outlet Circuit Tester Manuel utilisateur

Taper
Manuel utilisateur