Lincoln Electric Red-D-Arc GX-271 Mode d'emploi

Catégorie
Système de soudage
Taper
Mode d'emploi
RED-D-ARC
GX 271Chopper LPG
IM635
October, 2000
Red-D-Arc Spec-Built Welding Equipment
This RED-D-ARC welder is built to RED-D-ARC Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
For use with machines having Code Numbers:
10579
North America’s Largest Fleet of Welding Equipment
1-800-245-3660
OPERATOR’S MANUAL
GX 271 Chopper LPG
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar 95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines
The Above For Gasoline Engines
GX 271 Chopper LPG
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases.When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and below Threshold Limit Values (TLV)
using local exhaust or mechanical ventilation. In
confined spaces or in some circumstances, outdoors, a
respirator may be required. Additional precautions are
also required when welding on galvanized steel.
5.b.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating
products.
5.c. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95
GX 271 Chopper LPG
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
iii
SAFETY
iii
Mar ‘95
WELDING SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
GX 271 Chopper LPG
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de
l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible
de la zone de travail qu’il est pratique de le faire. Si on place
la masse sur la charpente de la construction ou d’autres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
d’opérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
Mar. ‘93
GX 271 Chopper LPG
Thank You
for selecting this QUALITY product. We want you to take pride in
operating this product ••• as much pride as we have in bringing
this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or
loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to
this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Model Name & Number _____________________________________
Code & Serial Number _____________________________________
Date of Purchase _____________________________________
Whenever you request replacement parts for or information on this equipment always supply the information
you have recorded above.
vv
GX 271 Chopper LPG
vi
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Installation Instructions.........................................................................................................A-3
Location and Ventilation................................................................................................A-3
Storing...........................................................................................................................A-3
Stacking ........................................................................................................................A-3
Angle of Operation ........................................................................................................A-3
Lifting.............................................................................................................................A-3
Additional Safety Precautions .......................................................................................A-3
Pre-Operation Engine Service..............................................................................................A-4
Fuel ...............................................................................................................................A-4
Oil..................................................................................................................................A-4
Battery Connections .............................................................................................................A-5
Muffler ...........................................................................................................................A-5
Spark Arrester ...............................................................................................................A-5
Electrical Connections..........................................................................................................A-6
Machine Grounding.......................................................................................................A-6
Welding Cable Connections..........................................................................................A-6
Auxiliary Power Receptacles, Plugs, and Hand-Held Equipment ........................................A-7
Circuit Breakers....................................................................................................................A-7
Premises Wiring ...................................................................................................................A-7
Operation.........................................................................................................................Section B
General Description..............................................................................................................B-1
Design Features ...................................................................................................................B-1
Other Features .....................................................................................................................B-2
Recommended Applications.................................................................................................B-2
Limitations ............................................................................................................................B-2
Additional Safety Precautions .............................................................................................B-2
Controls and Settings ..................................................................................................................B-3
Welder / Generator Controls .........................................................................................B-3
Engine Operation .................................................................................................................B-4
Before Starting the Engine ............................................................................................B-4
Starting the Engine........................................................................................................B-4
Stoping the Engine........................................................................................................B-5
Fuel Consumption Data ................................................................................................B-5
Welding Operation................................................................................................................B-6
Welder Controls - Function and Operation....................................................................B-6
Stick Welding ................................................................................................................B-7
Pipe Welding .................................................................................................................B-7
TIG Welding ..................................................................................................................B-7
Wire Welding.................................................................................................................B-8
Summary of Welding Processes and Machine Settings ...............................................B-9
Auxiliary Power...................................................................................................................B-10
Simultaneous Welding and Power Loads ...................................................................B-10
Accessories.....................................................................................................Section C
General Options / Accessories..............................................................................C-1
TIG Welding Options / Accessories.......................................................................C-1
Semiautomatic FCAW and MIG Welding Options / Accessories.........................................
C-2
Connection Diagrams for Accessories ..................................................................C-3
GX 271 Chopper LPG
vii
TABLE OF CONTENTS
Page
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine and Periodic Engine Maintenance ...........................................................D-1
Engine Maintenance Parts..............................................................................D-1
Engine Maintenance Schedule .......................................................................D-2
Changing the Engine Oil .................................................................................D-3
Changing the Engine Oil Filter ........................................................................D-3
Air Cleaner Service .........................................................................................D-3
Spark Plug Service .........................................................................................D-4
Fuel Filter Service ...........................................................................................D-5
Engine Adjustments ........................................................................................D-5
Battery Maintenance .......................................................................................D-5
Servicing Optional Spark Arrestor .........................................................................D-6
Welder / Generator Maintenance ..........................................................................D-6
Storage ...........................................................................................................D-6
Cleaning..........................................................................................................D-6
Brush Removal and Replacement ..................................................................D-6
Troubleshooting..............................................................................................Section E
Safety Precautions.................................................................................................E-1
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide ..........................................................................................E-2
Wiring Diagram & Dimension Print................................................................Section F
Parts List ......................................................................................................P325 Series
A-1
INSTALLATION
GX 271 Chopper LPG
A-1
TECHNICAL SPECIFICATIONS - Red-D-Arc GX-271 LPG (K1680-1)
Make/Model Description Speed (RPM) Displacement Starting Capacities
System
Kohler 2 cylinder High Idle 3700 38.1 cu. in
12VDC battery
Fuel: LPG cyl.
CH20S 20.0 HP @ Low Idle 2400 (624 cc) (Group 58, 435
Command® w/LP 3600 RPM Full Load 3500 cold crank amps)
Full Load Bore x Stroke Oil: 2.0 Qts.
4 Cycle 25A. Alternator 1.9 L
Air Cooled 3.03” x 2.64”
LPG Engine
(77 mm x 67 mm)
Overhead Valves
INPUT - ENGINE
RATED OUTPUT - WELDER
HEIGHT WIDTH DEPTH WEIGHT
30.3 in. 19.1 in. 43.8 in. 469 lbs.
770 mm 485 mm 1113 mm 212 kg.
OUTPUT - GENERATOR
Welding Output Volts at Rated Amps Duty Cycle
1
Max. OCV @ 3700 RPM
CC Stick/TIG, Pipe and CV Wire Welding
275 Amps 28 volts 100%
80 volts DC
300 Amps 25 volts 60%
Auxiliary Power
2
8,000 Watts, 60 Hz
120/240 Volts
100 % Duty Cycle
42 Volt Auxiliary Power for Wire Feeders
PHYSICAL DIMENSIONS
1. Duty cycle is based on a 10 minute period. This machine can be loaded to 300 amps for 6 minutes out of every 10 minute
period.
2. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
A-2
INSTALLATION
GX 271 Chopper LPG
A-2
TECHNICAL SPECIFICATIONS - Red-D-Arc GX-271 (K1680-1)
A-3
INSTALLATION
GX 271 Chopper LPG
A-3
INSTALLATION INSTRUCTIONS
SAFETY PRECAUTIONS
Only qualified personnel should install,
use, or service this equipment.
LOCATION AND VENTILATION
Whenever you use the GX-271, be sure that clean
cooling air can flow through the machine’s engine and
the machine case. Avoid dusty, dirty areas. Also,
keep the machine away from heat sources. Do not
place the engine end of the machine anywhere near
hot engine exhaust from another machine or closer
than two feet from a wall. And of course, make sure
that engine exhaust is ventilated to an open, outside
area.
The GX-271 may be used outdoors. Do not set the
machine in puddles or otherwise submerge it in water.
Such practices pose safety hazards and cause
improper operation and corrosion of parts.
Always operate the GX-271 with the case roof on and
all machine components completely assembled. This
will protect you from the dangers of moving parts, hot
metal surfaces, and live electrical devices.
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at
front of this operator’s manual.
-----------------------------------------------------------
WARNING
STORING
1. Store the machine in a cool, dry place when it is
not in use. Protect it from dust and dirt. Keep it
where it can’t be accidentally damaged from con-
struction activities, moving vehicles, and other
hazards.
2. Drain the engine oil and refill with fresh oil. Run
the engine for about five minutes to circulate oil to
all the parts. See the MAINTENANCE section of
this manual for details on changing oil.
3. Remove the battery, recharge it, and adjust the
electrolyte level. Store the battery in a dry, dark
place.
STACKING
GX-271 machines CANNOT be stacked.
ANGLE OF OPERATION
Place the machine on a secure, level surface whenev-
er you use it or store it. Any surfaces you place it on
other than the ground must be firm, non-skid, and
structurally sound.
The engine is designed to run in a level position for
best performance. It can operate at an angle, but this
should never be more than 15 degrees in any direc-
tion. If you do operate it at a slight angle, be sure to
check the oil regularly and keep the oil level at the
FULL mark as it would be in its normal level condition.
LIFTING
The GX-271 weighs approximately 469 lbs/212 kg. A
lift bail is mounted to the machine frame and should
always be used when lifting the machine.
ADDITIONAL SAFETY PRECAUTIONS
FALLING EQUIPMENT can cause
injury.
Do not lift this machine using lift
bale if it is equipped with a heavy
accessory such as trailer or gas
cylinder.
Lift only with equipment of adequate lifting
capacity.
Be sure machine is stable when lifting.
WARNING
A-4
INSTALLATION
GX 271 Chopper LPG
A-4
If growing bubbles appear, there is a leak. Re-tighten
connection or replace defective component. Retest to
make sure that there is no leak.
Leak test must be performed each time the fuel cylin-
der is replaced.
Always close the cylinder valve when the machine is
not being used.
The specification for aluminum lift truck cylinders are
shown below:
Capacity Cylinder Weight Footring
LP-Gas Volume Empty Outside
(LBS.) (Cu. In.) (LBS.) Diameter
33.5 2219 22.5 9 3/8”
43.5 2873 25.5 9 3/8”
Note: The GX 271 LPG cannot
be used with vapor draw
LP gas cylinders such as those used for recreation
vehicles, trailers, grilles, and boats.
OIL
The GX 271 is shipped with the engine crankcase filled
with SAE 10W-30 oil. Check the oil level before starting
the engine. If it is not up to the full mark on the dip stick,
add oil as required. Make certain that the oil filler cap is
tightened securely. Refer to the engine Owner’s Manual
for specific oil recommendations.
PRE-OPERATION ENGINE SERVICE
READ the engine operating and maintenance instruc-
tions supplied with this machine.
FUEL
A lift truck type coupler is provided on the supplied
fuel line for easy hand attachment to a lift truck type
LPG fuel cylinder. The fuel cylinder must meet D.O.T.
Specification 4E-240. The valve on the fuel cylinder
must
be installed on the outlet marked “LIQUID”.
The engine will not develop full power if connected to
the vapor outlet.
Be certain that the cylinder valve is CLOSED before
attempting to attach the fuel supply hose coupler to the
cylinder. Connect the coupler to the fuel cylinder and
tighten by hand.
___________________________________________
After connecting the fuel supply to the supply cylinder,
open the valve on the fuel cylinder and leak test by
brushing a 50/50 soap and water solution on to the fol-
lowing connections:
Both ends of the fuel hose where it enters the metal connector.
The threaded fitting on the end of fuel hose attached to the GX
271 LPG fuel shut off solenoid.
The fuel hose coupler and the connection to the cylinder valve.
The stem of the cylinder valve and where the valve is attached
to the top of the cylinder.
All other fittings on top of the fuel cylinder.
CAUTION
LPG
fuel can cause fire or explosion.
-
All leak testing must be done in a well
ventilated area free from all potential
ignition sources.
Keep sparks and flame away from machine and
LPG supply cylinder.
• Do not expose the LPG supply cylinder to temper-
atures exceeding 120°F (49°C).
• Do not weld on or near the LPG supply cylinder.
Do not smoke or allow any potential ignition sources
near the LPG supply cylinder.
Always be certain that the LPG supply cylinder is NOT
in the welding circuit. Do not allow either welding
cable to come in contact with the supply cylinder.
Replace the fuel supply hose if there is excessive
abrasion, cracks or wear or if the hose is cut.
------------------------------------------------------------------------
WARNING
CAUTION
LUBRICATION SYSTEM CAPACITY
(INCLUDING FILTER)
Kohler CH20S - 2.0 Quarts (1.9 Liters)
A-5
INSTALLATION
GX 271 Chopper LPG
A-5
BATTERY CONNECTIONS
GASES FROM BATTERY can explode.
Keep sparks, flame and cigarettes
away from battery.
To prevent EXPLOSION when:
INSTALLING A NEW BATTERY — disconnect
negative cable from old battery first and connect
to new battery last.
CONNECTING A BATTERY CHARGER —
remove battery from welder by disconnecting nega-
tive cable first, then positive cable and battery
clamp. When reinstalling, connect
negative cable last. Keep well ventilated.
USING A BOOSTER — connect positive lead to
battery first then connect negative lead to negative
battery lead at engine foot.
BATTERY ACID can burn eyes and
skin.
Wear gloves and eye protection and
be careful when working near battery.
Follow instructions printed on battery.
------------------------------------------------------------------------
WARNING
IMPORTANT: To prevent ELECTRICAL DAMAGE
WHEN:
a) Installing new batteries.
b) Using a booster.
Use correct polarity — Negative Ground.
The GX 271 is shipped with the negative battery cable
disconnected. Before you operate the machine, make
sure the Engine Switch is in the STOP position and
attach the disconnected cable securely to the negative
(-) battery terminal.
Remove the insulating cap from the negative battery
terminal. Replace and tighten negative battery cable
terminal. NOTE: This machine is furnished with a wet
charged battery; if unused for several months, the bat-
tery may require a booster charge. Be sure to use the
correct polarity when charging the battery.
MUFFLER
Shut off the machine and allow the muffler to cool
before touching the muffler.
------------------------------------------------------------------------
SPARK ARRESTER
Engine mufflers may emit sparks when the engine is
running. Some federal, state, or local laws require
spark arresters in locations where unarrested sparks
could present a fire hazard.
Standard mufflers do not act as spark arresters.
When local laws require it, a spark arrester must be
installed on the machine and properly maintained.
An incorrect spark arrester may lead to damage to the
engine or reduce performance.
------------------------------------------------------------------------
CAUTION
CAUTION
A-6
INSTALLATION
GX 271 Chopper LPG
A-6
ELECTRICAL CONNECTIONS
See Figure B.1 in the OPERATION section of this
manual for location of the 120 and 240 volt recepta-
cles, weld output terminals, circuit breakers and
ground stud.
MACHINE GROUNDING
Because the GX 271 creates its own power from its
engine driven generator, and if the machine is not
connected to premises wiring (home, shop, etc.), you
do not need to connect the machine frame to an earth
ground. However, for best protection against electri-
cal shock, connect a heavy gauge wire (#8 AWG or
larger) from the ground stud located on the bottom of
the output panel (See Figure B.1) to a suitable earth
ground such as a metal pipe driven into the ground.
Do not ground the machine to a pipe that carries
explosive or combustible material.
------------------------------------------------------------------------
When the GX 271 is mounted on a truck or a trailer,
the machine generator ground stud MUST be securely
connected to the metal frame of the vehicle. See
Figure B.1. The ground stud is marked with the
ground symbol.
If the GX 271 is connected to premises wiring such as
a home or shop, it must be properly connected to the
system earth ground.
WELDING CABLE CONNECTIONS
CABLE SIZE AND LENGTH
Be sure to use welding cables that are large enough.
The correct size and length becomes especially
important when you are welding at a distance from the
welder.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
Lincoln Electric offers a welding accessory kit with the
properly specified welding cables. See the
ACCESSORIES section of this manual for more infor-
mation.
WARNING
Table A.1
CABLE INSTALLATION
Install the welding cables to your GX 271 as follows.
See Figure B.1 for location of parts.
1. The engine must be OFF to install welding cables.
2. Remove the flanged nuts from the output terminals.
3. Connect the electrode holder and work cables to
the weld “+” and “-” output terminals. The terminals
are identified on the case front. The polarity require-
ment for the welding process being used deter-
mines which terminal the electrode cable is
attached to.
4. Tighten the flanged nuts securely.
5. Be certain that the metal piece you are welding (the
“work”) is properly connected to the work clamp and
cable.
6. Check and tighten the connections periodically.
Loose connections will cause the output terminals to
overheat. The terminals may eventually melt.
Do not cross the welding cables at the output termi-
nal connection. Keep the cables isolated and sepa-
rate from one another.
------------------------------------------------------------------------
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
Cable Length
0-50 Ft. (0-15 meters)
50-100 Ft. (15-39 meters)
100-150 Ft. (30-46 meters)
150-200 Ft. (46-61 meters)
200-250 Ft. (61-76 meters)
Cable Size for
300 Amps
100% Duty Cycle
1/0 AWG
1/0 AWG
2/0 AWG
2/0 AWG
3/0 AWG
CAUTION
A-7
INSTALLATION
GX 271 Chopper LPG
A-7
AUXILIARY POWER RECEPTACLES,
PLUGS, AND HAND-HELD EQUIPMENT
The control panel of the GX 271 features three auxil-
iary power receptacles: See Figure B.1.
• Two 15 amp, 120 volt duplex (double outlet) recepta-
cles.
• One 50 amp 120/240 volt single outlet receptacle.
Through these receptacles the machine can supply up
to 8,000 rated continuous watts of single-phase, 60
Hz AC power.
For further protection against electric shock, any elec-
trical equipment connected to the 120V duplex recep-
tacles must use a three-blade, grounded type plug or
an Underwriter’s Laboratories (UL) approved double
insulation system with a two-blade plug. Lincoln
offers an accessory plug kit that has the right type of
plugs. See the ACCESSORIES section of this manual
for more information.
If you need ground fault protection for hand-held
equipment refer to the K896-1 GFCI Receptacle kit in
the ACCESSORIES section of this manual for more
information.
For recommended extension cord lengths and sizes
see Table A.1.
CIRCUIT BREAKERS
The GX 271 machines are equipped with 50 amp cir-
cuit breakers on the 120/240 V receptacle and 15 amp
circuit breakers on the 120 receptacles for overload
protection. Under high heat a breaker may tend to trip
at lower loads than it would normally.
Never bypass the circuit breakers. Without overload
protection, the GX 271 could overheat and/or cause
damage to the equipment being used.
------------------------------------------------------------------------
CAUTION
PREMISES WIRING
The GX 271 is suitable for temporary, standby, or
emergency power using the engine manufacturer’s
recommended maintenance schedule. With its three-
wire grounded neutral generator, it can be permanent-
ly installed as a standby power unit for 240 volt, three
wire, single phase 33 ampere service.
Only a licensed, certified, trained electrician should
install the machine to a premises or residential elec-
trical system. Be certain that:
The installation complies with the National Electrical
Code and all other applicable electrical codes.
The premises is isolated and no feedbacking into
the utility system can occur. Certain state and local
laws require the premises to be isolated before the
generator is linked to the premises. Check your
state and local requirements.
A double pole, double throw transfer switch in con-
junction with the properly rated double throw circuit
breaker is connected between the generator power
and the utility meter.
------------------------------------------------------------------------
The following information and the connection diagram,
Figure A.1, can be used as a guide by the electrician
for most applications to premises wiring.
1. Install a double pole, double throw switch between
the power company meter and the premises dis-
connect. The switch rating must be the same as
or greater than the premises disconnect and
service overcurrent protection.
2. Take the necessary steps to assure that the load is
limited to the capacity of the GX 271 by installing a
35 amp 240 volt double pole circuit breaker.
Maximum rated load for the 240 volt auxiliary is 33
amperes. Loading above 33 amperes will reduce
output voltage below the allowable -10% of rated
voltage. This may damage appliances or other
motor-driven equipment.
3. Install a 50 amp 120/240 volt plug (NEMA type 14-
50) to a double pole circuit breaker using No. 8 or
larger, 4 conductor cable of the desired length.
(The 50 amp 120/240 volt plug is available in the
optional power plug kit.
4. Plug this cable in to the 50 amp 120/240 volt recep-
tacle on the GX 271 case front.
WARNING
A-8
INSTALLATION
GX 271 Chopper LPG
A-8
Connection of GX 271 to premises wiring must be done by a licensed electrician and must comply with
the National Electrical Code and all other applicable electrical codes.
230 Volt
60 Hz.
3-Wire
Service
POWER
COMPANY
METER
230 VOLT
115 VOLT
115 VOLT
LOAD
N
NEUTRAL
BUS
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
GND
N
NOTE: No. 8 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
230 VOLT
GROUNDED CONDUCTOR
35 AMP
230 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 115/230
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 115/230 VOLT
RECEPTACLE
Figure A.1
CONNECTION OF GX 271 TO PREMISES WIRING
Table A.1
Extension Cord Length Recommendations
WARNING
Current Voltage Load Maximum Allowable Cord Length in ft (m) for Conductor Size (AWG)
(Amps) (Volts) (Watts) 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG
15 120 1800 30 (9) 40 (12) 75 (23) 125 (38) 175 (53) 300 (91)
15 240 3600 60 (18) 75 (23) 150 (46) 225 (69) 350 (107) 600 (183)
20 240 4800 60 (18) 100 (30) 175 (53) 275 (84) 450 (137)
25 240 600 90 (27) 150 (46) 225 (69) 250 (76)
30 240 7200 75 (23) 120 (37) 175 (53) 300 (91)
35 240 8400 100 (30) 150 (46) 250 (76)
B-1
OPERATION
GX 271 Chopper LPG
B-1
OPERATING INSTRUCTIONS
Read and understand this entire section before oper-
ating your GX 271.
SAFETY INSTRUCTIONS
Do not attempt to use this equipment until you have
thoroughly read all operating and maintenance man-
uals supplied with your machine. They include impor-
tant safety precautions, detailed engine starting,
operating and maintenance instructions and parts
lists.
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such
as output terminals or internal wiring.
•Insulate yourself from the work and
ground.
•Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
•Use in open, well ventilated areas or
vent exhaust outside
•Do not stack anything near the engine.
------------------------------------------------------------------------
MOVING PARTS can injure.
•Do not operate with doors open or
guards off.
•Stop engine before servicing.
•Keep away from moving parts
------------------------------------------------------------------------
Only qualified personnel should operate this equip-
ment.
GENERAL DESCRIPTION
The GX 271 is an engine driven, multi-process DC arc
welder and AC power generator for commercial and
residential applications. As a generator it can supply
up to 8,000 continuous watts of 120/240 volt, 60 Hz,
single-phase AC power to operate AC power tools,
battery chargers, and lighting; it can also be used to
provide standby power. As a welder it provides up to
300 amps of DC current for DC stick welding and DC
semiautomatic wire feed welding. The GX 271 can
also perform DC TIG welding.
DESIGN FEATURES
FOR WELDING:
DC constant current output for stick and TIG weld-
ing - Two continuous CC output settings of 20 to
300 amps, one for general purpose stick and tig
welding and one with a fixed controlled slope for out
of position and pipe welding. The STICK-TIG mode
includes an arc force control.
DC constant voltage output for MIG and Flux Cored
wire welding - One continuous CV welding range of
11 to 32 volts. Excellent MIG welding with CO2 and
blended gas. A pinch control allows the arc to be
fine tuned from “soft “ to “crisp”. The recommended
wire feeder is the K446 LN-25 with the K624-1 42
Volt Remote Output Control Module or the K449 LN-
25 with an internal contactor.
• 100% duty cycle at 275 amps output.
Remote control capability. Nine pin and fourteen
pin connectors for easy connection of Lincoln wire
feeders and remote control accessories. The 14 pin
connector includes power for 42 VAC wire feeders.
Internal “Solid State” contactor allows for the selec-
tion of “hot” or “cold” output terminals.
FOR AUXILIARY POWER
• 8,000 watts of 240 V AC, 60Hz auxiliary power.
Power for tools, 120/240 lights, electric pumps and
for standby emergency power.
• Power a 1-1/2 HP motor (provided it is started under
no load).
Two 15 amp industrial grade 120 V AC duplex
receptacles for up to 60 amps of 120 VAC power.
WARNING
GX 271 Chopper LPG
B-2
OPERATION
B-2
One 50 amp 120/240 V AC, single phase power,
dual voltage receptacle with two 50 amp circuit
breakers. Supplies up to 33 amps of 240 V AC and
up to 66 amps of 120 V AC single phase auxiliary
power per side to separate branch circuits (not in
parallel). Allows easy connection to premises wiring.
Welding and AC auxiliary power at the same time
(within machine total capacity).
OTHER FEATURES
Overhead valve, 20 HP LPG engine. Designed for
long life, easy maintenance and excellent fuel econ-
omy.
Engine protection system shuts the engine down
with low oil pressure.
Large maintenance-free battery. Group 58 with 435
cold cranking amps.
• Battery charging ammeter.
• Engine hour meter.
Automatic idler reduces engine speed when not
welding or drawing auxiliary power. This feature
reduces fuel consumption and extends engine life.
Compact size fits crosswise in compact size pick-up
truck.
Copper alternator windings for dependability and
long life.
• CSA approved.
RECOMMENDED APPLICATIONS
WELDER
The GX 271 provides excellent constant current DC
welding output for stick (SMAW) welding and for TIG
welding, and it offers constant voltage output for DC
semiautomatic wire feed welding.
GENERATOR
The GX 271 gives AC power output for medium use
demands.
LIMITATIONS
The GX 271 is not recommended for any process-
es besides those that are normally performed using
stick welding (SMAW), TIG welding (GTAW), MIG
(GMAW) welding and Innershield® (FCAW) welding.
• The GX 271 is not recommended
for pipe thawing.
During welding, generator power is limited and out-
put voltages can drop. Therefore, DO NOT OPER
-
ATE ANY SENSITIVE ELECTRICAL EQUIPMENT
WHILE YOU ARE WELDING. See Table B.4 for
permissible simultaneous welding and auxiliary
power loads.
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the roof and case
sides in place as this provides maximum protection
from moving parts and assures proper cooling air flow.
Read and understand all Safety Precautions before
operating this machine. Always follow these and any
other safety procedures included in this manual and in
the Engine Owner’s Manual.
Only qualified personnel should install, use, or service
this equipment.
GX 271 Chopper LPG
B-3
OPERATION
B-3
CONTROLS AND SETTINGS
All generator/welder controls are located on the
Output Control Panel of the machine case front. Idler
control, and start/stop controls are also on the case
front. See Figure B.1 and the explanations that follow.
FIGURE B.1
OUTPUT PANEL CONTROLS
WELDER/GENERATOR CONTROLS
See Figure B.1 for the location of the following features:
1. OUTPUT CONTROL: Allows full range adjustment of
welding current or voltage.
2. ARC CONTROL: The “ARC CONTROL” potentiome-
ter is active in two modes: “STICK/TIG” and “WIRE
WELDING” with different purposes in each mode.
3. MODE SWITCH: Selects three possible modes of
welding operation, 1.) CC Stick/Tig welding, 2.) Pipe
welding, and 3.) CV Wire Welding.
4. LOCAL/REMOTE CONTROL SWITCH: Allows the
operator to control welding output at the welding con-
trol panel or at a wire feeder, TIG amptrol, or a K857
remote control.
5. WELDING TERMINALS SWITCH: The toggle switch
labeled “WELDING TERMINALS ALWAYS ON” and
“WELDING TERMINALS REMOTELY CON-
TROLLED” is used to control the operation of the
solid state output contactor. With the switch in the
“WELDING TERMINALS ALWAYS ON” position, the
contactor is closed at low and high idle.
6. BATTERY CHARGER CIRCUIT BREAKER: Opens
the engine battery circuit if a short develops. Engine
will not crank if this circuit breaker is open.
7. WIRE FEEDER POWER CIRCUIT BREAKER: Opens
the wire feeder circuit and disables the feeder if a fault
is detected in the circuit.
8. 15 AMP, 120 VOLT DUPLEX RECEPTACLES:
Connection point for supplying 120 volt power to oper-
ate one or more electrical devices.
9. 50 AMP, 120/240 VOLT RECEPTACLE: Connection
point for supplying 240 volt power to operate one
electrical device.
10. WELD OUTPUT TERMINALS WITH FLANGE NUT:
Provides the connection point for the electrode and
work cables.
11. GROUND STUD: Provides a connection point for
connecting the machine case to earth ground for the
safest grounding procedure.
12. 6 PIN AMPHENOL: For attaching optional remote
control equipment to the GX 271.
13. 14 PIN AMPHENOL: For attaching wire feeder con-
trol cables to the GX 271 (Includes contactor closure
circuit, remote control circuit, wire feeder 115/42 volt
power source).
14. WIRE FEEDER VOLTMETER POLARITY SWITCH:
matches polarity of wire feeder voltmeter to polarity
of electrode.
15. ENGINE RUN-STOP SWITCH: Energizes engine cir-
cuit.
16. ENGINE START PUSHBUTTON SWITCH:
Energizes starter solenoid contactor and fuel sole-
noid.
17. ENGINE CHOKE
18. AUTO IDLER SWITCH: In the “AUTO” mode, the
engine goes to low idle speed 12 seconds after a
welding or auxiliary power load is removed. Engine
goes to high speed when the load is re-applied.
19. BATTERY CHARGER AMMETER
20. ENGINE HOUR METER
5
4 3
15
17
18
16
19
20
11
121413
10
6
7
9
8
1
2
GX 271 Chopper LPG
B-4
OPERATION
B-4
ENGINE OPERATION
DO NOT RUN THE ENGINE AT EXCESSIVE
SPEEDS. The maximum allowable high idle speed
for the GX 271 is 3750 RPM, no load. Do NOT adjust
the governor screw on the engine. Severe personal
injury and damage to the machine can result if it is
operated at speeds above the maximum rated speed.
------------------------------------------------------------------------
Read and understand all safety instructions included
in the Engine Owner’s manual that is shipped with
your GX 271.
BEFORE STARTING THE ENGINE
Check the engine oil level:
1. Be sure the machine is on a level surface.
2. Remove the engine oil dipstick and wipe it with a
clean cloth. Reinsert the dipstick and check the
level on the dipstick.
3. Add oil (if necessary) to bring the level up to the full
mark. Do not overfill.
4. See Engine Owner’s Manual for specific oil recom-
mendations.
WARNING
STARTING THE ENGINE
Be sure all Pre-Operation Maintenance has been per-
formed. See the INSTALLATION section.
Remove all loads connected to the AC power recepta-
cles and the welder before starting the engine.
------------------------------------------------------------------------
To start the engine, set the “IDLER” switch in the
“AUTO” ( / ) position.
Open the fuel valve on the supply cylinder. Pull the
choke control out.
Place the “Engine” Switch in the “RUN” Position.
Push the “Start” button and crank the engine until it
starts. Release the button as soon as the engine
starts. After the engine has started, slowly return the
choke control to the full “in” position (choke open). In
the “AUTO” position, the engine will run at high idle for
10-14 seconds and then go to low idle. Allow the
engine to warm up by letting it run at low idle for a few
minutes.
At cold temperatures, it may be necessary to start the
engine in “HIGH” idle and allow it to run for several
minutes before using “AUTO” idle.
Operating the starter motor for more than 5 seconds
can damage the motor. If the engine fails to start,
release the switch and wait 10 seconds before operat-
ing the starter again. Do not push the “Start” button
while the engine is running because this can damage
the ring gear and/or starter motor.
------------------------------------------------------------------------
CAUTION
CAUTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Lincoln Electric Red-D-Arc GX-271 Mode d'emploi