Hestan GABR36-LP-OR Le manuel du propriétaire

Catégorie
Barbecues
Taper
Le manuel du propriétaire
OUTDOOR COOKING
Grill with Rotisserie
GABR / GSBR / GMBR
Use & Care Manual
Installation & Operation
HESTAN OUTDOOR, MOST
POWERFUL, VERSATILE AND
RELIABLE RESIDENTIAL
GRILL AVAILABLE.
Message from Hestan:
Outdoor cooking is a perfectionist’s pursuit, and with your new investment,
you’ve now taken the ultimate step forward. We sincerely welcome you to
the Hestan Family. We’ve engineered and built our products so that your
guests will rave about your meal, but deep down, our customers know it
could’ve been just a little more tender, juicier – a pinch more salt in the rub
or a few seconds less on the flame. Yes, we’ve taken the time to know our
Hestan customer and we’re excited to be on this journey with you. Hestan
Outdoor was born from this same perfectionist passion. Our engineers
experimented, innovated, tweaked and tinkered until they created the most
powerful, versatile and reliable outdoor products available.
We pride ourselves on restless innovation, superior engineering and
purpose-built designs, but also our in-depth understanding of our target
consumer and the interests and needs of the ultimate end-users we serve
and covet. For many consumers, cooking outdoors is much more than an
act of food preparation. It’s a lifestyle activity that encompasses culinary,
leisure and social pursuits among others.
We are thankful and proud that you have chosen Hestan, and we yearn to
have you as a customer for life. We take your decision to choose Hestan
most seriously, and we promise to deliver the very best to you.
Welcome to Hestan Outdoor
©2019 Hestan Commercial Corporation
1
EN
©2019 Hestan Commercial Corporation
2
EN
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not try lighting this appliance without reading the LIGHTING
INSTRUCTIONS section of this manual.
For outdoor use ONLY. This cooking appliance is not intended to be
installed in or on recreational vehicles, and/or boats.
Flammable Gas - disconnect all propane or natural gas supplies to this
unit before servicing.
Electrical Parts & Components – disconnect all power supplies and
batteries before servicing.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or your fire department.
DANGER
1. Do not store or use gasoline or
other flammable liquids or vapors
in the vicinity of this or any other
appliance.
2. An LP cylinder not connected
for use shall not be stored in
the vicinity of this or any other
appliance.
READ THIS MANUAL CAREFULLY AND COMPLETELY BEFORE USING YOUR
GRILL TO REDUCE THE RISK OF FIRE, BURN HAZARD, OR OTHER INJURY.
KEEP THIS MANUAL FOR FUTURE REFERENCE.
©2019 Hestan Commercial Corporation
3
EN
4 MODEL NUMBERS
6 RATING LABELS
6 PRECAUTIONS
9 REGULATORY / CODE REQUIREMENTS
9 PORTABLE LP CYLINDERS
10 LOCATION AND ASSEMBLY
12 INSTALLATION
15 GAS CONNECTIONS
22 ELECTRICAL SUPPLY
25 LIGHTING INSTRUCTIONS
27 USING YOUR GRILL
28 CLEANING AND MAINTENANCE
33 TROUBLESHOOTING
34 WIRING SCHEMATICS
38 PARTS LIST
38 SERVICE
38 WARRANTY
TABLE OF CONTENTS
©2019 Hestan Commercial Corporation
4
EN
BUILT-IN MODELS
Model No. Description
GABR30-NG / -LP 30” BUILT-IN (ALL TRELLIS BURNERS)
GMBR30-NG / -LP 30” BUILT-IN (SEAR AND TRELLIS BURNERS)
GSBR30-NG / -LP 30” BUILT-IN (ALL SEAR BURNERS)
GABR36-NG / -LP 36” BUILT-IN (ALL TRELLIS BURNERS)
GMBR36-NG / -LP 36” BUILT-IN (SEAR AND TRELLIS BURNERS)
GSBR36-NG / -LP 36” BUILT-IN (ALL SEAR BURNERS)
GABR42-NG / -LP 42” BUILT-IN (ALL TRELLIS BURNERS)
GMBR42-NG / -LP 42” BUILT-IN (SEAR AND TRELLIS BURNERS)
GSBR42-NG / -LP 42” BUILT-IN (ALL SEAR BURNERS)
FREESTANDING MODELS
Model No. Description
GABR30-NG/-LP & GCD30 30” FREESTANDING (ALL TRELLIS BURNERS) DOUBLE DOOR CART
GMBR30-NG/-LP & GCD30 30” FREESTANDING (SEAR AND TRELLIS BURNERS) DOUBLE DOOR CART
GSBR30-NG/-LP & GCD30 30” FREESTANDING (ALL SEAR BURNERS) DOUBLE DOOR CART
GABR30-NG/-LP & GCR30 30” FREESTANDING (ALL TRELLIS BURNERS) DRAWER AND DOOR CART
GMBR30-NG/-LP & GCR30 30” FREESTANDING (SEAR AND TRELLIS BURNERS) DRAWER AND DOOR CART
GSBR30-NG/-LP & GCR30 30” FREESTANDING (ALL SEAR BURNERS) DRAWER AND DOOR CART
GABR36-NG/-LP & GCD36 36” FREESTANDING (ALL TRELLIS BURNERS) DOUBLE DOOR CART
GMBR36-NG/-LP & GCD36 36” FREESTANDING (SEAR AND TRELLIS BURNERS) DOUBLE DOOR CART
GSBR36-NG/-LP & GCD36 36” FREESTANDING (ALL SEAR BURNERS) DOUBLE DOOR CART
GABR36-NG/-LP & GCR36 36” FREESTANDING (ALL TRELLIS BURNERS) DRAWER AND DOOR CART
GMBR36-NG/-LP & GCR36 36” FREESTANDING (SEAR AND TRELLIS BURNERS) DRAWER AND DOOR CART
GSBR36-NG/-LP & GCR36 36” FREESTANDING (ALL SEAR BURNERS) DRAWER AND DOOR CART
GABR42-NG/-LP & GCR42 42” FREESTANDING (ALL TRELLIS BURNERS) DRAWER AND DOOR CART
GMBR42-NG/-LP & GCR42 42” FREESTANDING (SEAR AND TRELLIS BURNERS) DRAWER AND DOOR CART
GSBR42-NG/-LP & GCR42 42” FREESTANDING (ALL SEAR BURNERS) DRAWER AND DOOR CART
Built-in Model Freestanding Model
MODEL NUMBERS
GRILLING IS A PERFECTIONIST’S PURSUIT.
©2019 Hestan Commercial Corporation
6
EN
RATING LABEL
The rating label contains important information about your Hestan appliance such as the model
and serial number, gas type and manifold pressure, the BTU rating for each burner type, and the
minimum installation clearances.
PRECAUTIONS - BEFORE YOU USE YOUR GRILL
When properly cared for, your Hestan grill will provide safe, reliable service for many years.
However, extreme care must be used since the grill produces intense heat, which can cause
serious injury or even death if the instructions are not followed carefully. When using this
appliance, basic safety practices must be followed as outlined below.
1. NEVER LEAVE THE GRILL UNATTENDED WHILE COOKING.
2. Children should not be left alone or unattended in an area where the grill is being used.
Never allow them to sit, stand, or play on or around the grill. Do not store items of interest
to children around or below the grill or in the cart. Never allow children to crawl inside of
the cart.
3. Never operate the grill while under the influence of alcohol or drugs.
4. Never use the grill in windy conditions. If located in a consistently windy area, oceanfront,
mountaintop, etc., a Wind Screen will be required (available from Hestan). Always adhere to
the specified clearances as described in the INSTALLATION section of this manual.
5. The grill shall be used only outdoors and shall not be used in buildings, garages, sheds,
breezeways, or any enclosed areas. Do not operate the grill under unprotected, combustible
construction. Use only in well-ventilated areas. See the INSTALLATION section of this
manual.
6. Do not use the grill unless a leak check has been performed on all gas connections. See the
GAS CONNECTIONS section of this manual.
7. If the grill is installed by a professional installer or technician, be sure that they show you
where your gas supply shut-off is located. All gas lines must have a shut-off that is easily
accessible. If you smell gas, check for leaks immediately. Check only with a soap and water
solution. Never check gas leaks with an open flame. See the GAS CONNECTIONS section
of this manual.
8. Check the regulator, hoses, burner ports, air shutter, and venturi / valve section carefully.
Always turn off gas at the source (tank or supply line) prior to inspecting parts.
9. When lighting a burner, always pay close attention to what you are doing. Be certain you are
turning the correct knob labeled for the burner you intend to use. If any burner does not
light, or goes out during operation, turn off all gas control knobs, open the hood and wait
five (5) minutes before attempting to re-light. See the LIGHTING INSTRUCTIONS section
of this manual.
Hestan Grill rating
label is located on
the underside of the
drip pan.
©2019 Hestan Commercial Corporation
7
EN
10. Portable LP cylinders - Always shut off the main valve on the liquid propane (LP) cylinder
after each use. Never use a dented or rusted LP cylinder. Never attach or disconnect an LP
cylinder, or move or alter gas fittings when the grill is in operation or is hot.
11. Inspect LP gas supply hose prior to each use of the grill. The hose must be kept away from
heated areas of the grill. If there is evidence of excessive abrasion or wear, or the hose is
cut, it must be replaced before using the grill. The hose and LP regulator are supplied as a
complete assembly and must be replaced together. Do not attempt to repair or replace the
hose itself. Contact your Hestan dealer for genuine replacement P/N 014309.
12. Keep any electrical supply cord away from the heated areas of the grill. The cord is provided
with a 3-prong grounding plug which should not be removed or altered. Do not use this
appliance with an ungrounded, 2-prong adapter. The cord must be plugged into a properly
grounded GFCI-protected outlet. See INSTALLATION section of this manual.
13. Spiders and insects like to nest in the burners, venturis, valves, and orifices of a grill,
disrupting the gas flow in the burner. This very dangerous condition can cause a fire behind
the control panel, damaging the grill and risking personal injury. If your grill has been
unused for a long time, inspect and clean the burners, venturis, valves, and orifices. It is
recommended you inspect your grill at least twice a year. See BURNER ADJUSTMENT
section of this manual for details.
14. Keep the areas surrounding the grill free from combustible materials, trash, or combustible
fluids and vapors such as gasoline or charcoal lighter fluid. Do not obstruct the flow of
combustion gases (rear) and ventilation airways (front).
15. If your grill is mounted on a cart, keep the rear area free and clear of debris, extra LP
cylinders, etc. Do not block the ventilation louvers of the cart.
16. If your grill is mounted on a cart and stored indoors, ensure that it is cool before moving.
If propane is used, the LP cylinder must be disconnected and stored OUTSIDE in a well-
ventilated area, out of the reach of children. A grill cover is recommended, even when stored
indoors.
17. Never move the grill when hot. When in use, portions of the grill are hot enough to cause
severe burns.
18. Always have an “ABC” type fire extinguisher accessible – never attempt to extinguish a grease
fire with water or other liquids.
19. Avoid wearing loose-fitting garments or long sleeves while grilling. They could ignite.
For personal safety, wear proper apparel while grilling. Some synthetic fabrics are highly
flammable and should not be worn while grilling.
20. Never let pot holders, grill covers, or other flammable materials come in contact with or
too close to any cooking grate, burner, or hot surface until it has cooled down sufficiently.
Fabrics may ignite and result in personal injury. Use only dry potholders. Moist or damp
potholders on hot surfaces may cause burns from steam. Do not use a towel or bulky cloth
in place of potholders. Do not let potholders touch hot portions of the cooking grates or
warming racks.
21. Never touch the cooking grates, hood, or immediate surrounding metal surfaces with your
bare hands while grilling, as these areas become extremely hot and could cause burns. Use
only the handles and knobs provided for operation of the grill.
22. Protect your hand when opening a hot grill hood. Use an insulated glove or mitt when
operating the grill. Always open the hood slowly to allow heat and smoke to escape before
fully opening. Keep your face and body as far away as possible when opening the hood.
Never lean over an open hot grill.
PRECAUTIONS - BEFORE YOU USE YOUR GRILL
(continued)
©2019 Hestan Commercial Corporation
8
EN
23. The grill hood must be fully opened while lighting the grill. Opening the gas valves on a
closed grill before lighting will not make it light sooner or more efficiently. It will only risk
explosion and personal injury, or death. Never lean over a hot grill surface, or look directly
into the grill when attempting to light. See the LIGHTING INSTRUCTIONS section of this
manual.
24. Do not heat unopened food containers (cans) as pressure build-up will cause the container to
explode.
25. Do not use aluminum foil to line cooking grates or the drip tray. This will alter the airflow
to the grill or trap excessive heat in the control area. This can melt control knobs, wiring, or
igniters, and increase the risk of personal injury. Such damage is specifically excluded from
our warranty.
26. Never grill without the drip tray in place and pushed all the way to the back of the grill.
Without the drip tray, hot grease can leak downward creating a fire or explosion hazard.
27. Grease is extremely flammable. Let hot grease cool before attempting to handle or dispose
of it. Avoid letting grease deposits collect in the bottom of the grill by cleaning the drip tray
often. Never clean while the grill is on, or hot from recent use.
28. Grilling excessively fatty meats and oils will cause flare-ups. Internal fires or damage caused
by them or by the grill being left unattended, are not covered under the terms and conditions
of our warranty.
29. Never use charcoal, pellets, wood, or any other solid fuel in the grill. Wood chips for smoking
are to be used with the smoker accessory only. See the SMOKER section of this manual.
30. Only certain types of glass, heatproof glass-ceramic, earthenware, or other glazed utensils are
suitable for grill use. However, these types of materials may break with sudden temperature
changes. Use only on low or medium heat settings, and according to their manufacturers’
directions.
31. Do not lean on side shelves or place a load of more than 25 lbs [11.3 kg] on a side shelf.
32. Do not repair or replace any part of the grill unless specifically recommended in this manual.
All other warranty and non-warranty service should be referred to and performed by a
qualified technician.
33. For proper lighting and performance of the burners, keep the ports clean. It is necessary
to clean them periodically for optimum performance. The burners will operate only in one
position and must be mounted correctly for safe operation. See BURNER ADJUSTMENT
section of this manual.
34. Clean the grill with caution. Avoid steam burns - do not use a wet sponge or cloth to clean
the grill while it is hot. Some cleaners produce noxious fumes or can ignite when applied to
a hot surface. Be sure all grill controls are turned off and the grill is cool before using any
type of aerosol cleaner on or around the grill. The chemical that produces the spraying action
could, in the presence of heat, ignite or cause metal parts to corrode. Clean and perform
general maintenance on the grill twice a year. Watch for corrosion, cracks, or insect activity.
See the CLEANING AND MAINTENANCE section of this manual.
PRECAUTIONS - BEFORE YOU USE YOUR GRILL
(continued)
©2019 Hestan Commercial Corporation
9
EN
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance with local codes. In the
absence of local codes, this unit should be installed in accordance with the National Fuel Gas
Code
ANSI Z223.1/NFPA 54
, Natural Gas and Propane Installation code
CSA B149.1
, or Propane
Storage and Handling Code
B149.2
.
All Electrical Components must be electrically grounded in accordance with local codes or in the
absence of local codes with the National Electrical Code
ANSI/NFPA 70
, or Canadian Electrical
code
CSA C22.1
.
STATE OF MASSACHUSETTS
Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate
Massachusetts license. All permanently installed natural gas or propane installations require a T
handle type manual gas valve be installed in the gas supply line to this appliance. This does not
apply to portable propane installations using a 20lb. cylinder.
CALIFORNIA PROPOSITION 65 - WARNING
WARNING: This product can expose you to chemicals including carbon monoxide,
which is known to the State of California to cause birth defects and other reproductive
harm. For more information, go to www.P65Warnings.ca.gov.
PORTABLE LP GAS CYLINDERS
Use only a standard 20 lb. [9.1 kg] liquid propane (LP) gas cylinder - 12.25” diam. X 18.25” H
[31 cm X 47 cm] which features an Overfill Protection Device. The cylinder must be installed in
the upright position. Do not use a dented or rusty LP cylinder as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve. Never move or alter
the gas fittings. Check the expiration date on the cylinder collar as well. Do not refill an expired
cylinder, it must be replaced. If you buy refilled (exchange) LP cylinders, check this date as well.
The LP gas cylinder must be constructed and marked in accordance with the specifications for
LP gas cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided
with a shut off valve terminating in an LP gas supply cylinder valve outlet specified, as applicable,
for connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet
connections ANSI/CGA-V-I.
Certain liquid propane dealers may fill LP cylinders for use in the grill beyond cylinder filling
capacity. This “overfilling” may create a dangerous condition due to a build-up of excess pressure.
As a safety device, there is a pressure relief valve which will vent propane gas vapor to relieve this
excess pressure. This vapor is combustible and therefore can be ignited. To reduce this danger,
you should take the following safety precautions:
1. When you have your cylinder filled, be sure you tell the supplier to fill it to no more than 80%
of its total capacity.
2. If you own or use a spare cylinder, you should NEVER store it near or under the grill/cart unit
or burner box, or near any other ignition or heat source (like a water heater or furnace).
IF THE INFORMATION IN 1 AND 2 ABOVE IS NOT FOLLOWED EXACTLY, A FIRE
CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
3. The LP cylinder must be disconnected and stored OUTSIDE in a well-ventilated area, out of
the reach of children.
4. Do not store a full cylinder in direct sunlight.
©2019 Hestan Commercial Corporation
10
EN
LOCATING AND ASSEMBLING THE GRILL
LOCATION
When determining a suitable location for your grill, take into account concerns such as exposure
to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs as short as
possible.
Locate the grill only in a well-ventilated area. Never locate the grill in a building, garage,
breezeway, shed or other such enclosed areas without an approved ventilation system. Never
locate the grill over, under, or next to unprotected combustible construction.
AIRFLOW / WINDY AREAS
During heavy use, the grill will produce a lot of heat and smoke. The grill is designed to take in cool
air at the front control panel area, and send the combustion products and smoke out the exhaust
gap at the rear of the hood. IT IS IMPORTANT TO MAINTAIN THIS FLOW AT ALL TIMES.
Using the grill in windy areas can disrupt the proper flow and cause damage to your grill, or result
in burn hazards to the user. Initial indications of this situation are very hot control knobs. If this
happen, use an oven mitt or other protection, and while keeping your face away, immediately open
the hood to release the built up heat inside the grill. Turn down the burners to a lower setting. If
you have a free-standing grill on a cart, re-orient the grill so the prevailing wind is toward the front
of the grill as seen below in Fig. 1.
For built-in grill installations which consistenly receive wind at the rear of the grill, a Wind Screen
accessory is available from Hestan. Contact your Hestan dealer for details.
Damage caused from use in windy conditions, such as melted knobs
and/or wiring, discoloration of the control panel, etc., is excluded from
warranty coverage.
OTHER CONSIDERATIONS
When installing a grill or other gas appliance into an enclosure (island), the enclosure must be
constructed with ventilation openings to avoid accumulation of gas should there be a leak. See the
INSTALLATION section of this manual for details.
Ensure all packaging, straps, etc. have been removed from the grill. Remove any tie-down wires
from the burners.
Your Hestan grill has provision for mounting onto a mobile cart if you choose to do so. Contact
your Hestan dealer for the appropriate cart for your grill. If your grill is mounted on a cart, engage
the brakes on the casters to prevent movement of the cart.
Figure 1
©2019 Hestan Commercial Corporation
11
EN
Ensure that the burners are positioned correctly on their orifices, and are fully seated onto their
rear hanger brackets (see Fig. 2). The burners should not move side-to-side or front-to-back if
properly seated.
Above each Trellis Burner
is a stainless steel radiant tray containing specially shaped ceramic
briquettes. Position the radiant trays onto the lower ledge of the burner box in the grill, and then
install the cooking grates on the upper ledge (see Fig. 3). The burners and radiant trays work
together to create a very even heat, front-to-back, left-to-right. The radiant trays also serve to
minimize flare-ups, and prevent blockages of the burner ports from falling grease and debris. The
radiant trays and Trellis Burners must be used together and are integral to the performance of the
grill. Do not cook on the grill without them.
Note: Infrared Sear Burners do not require the radiant trays. NEVER place a radiant tray over a
Sear Burner.
Figure 2
Figure 3
LOCATING AND ASSEMBLING THE GRILL
(continued)
©2019 Hestan Commercial Corporation
12
EN
INSTALLATION
CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4” [10 cm] clearance from the back of the grill to non-combustible construction is
required to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible
construction. If your enclosure (island) is combustible, then an insulated jacket manufactured
by Hestan, is required. See INSULATED JACKET dimensions below to make allowances in your
enclosure for this item. A minimum clearance to vertical combustible material, such as adjacent
walls, is 12” [30 cm] on the sides and the rear of the appliance.
The minimum vertical clearance to combustible materials means that ALL combustible materials
must be outside this 12” [30 cm] zone. As an example, if you have an island with a stucco or
tiled surface and wood-frame construction beneath, or wood-frame walls adjacent or behind,
the wood is considered combustible, even though the grill is touching the stucco or tiled surface,
which is non-combustible. In extreme circumstances, the wood could potentially get hot enough
to burn.
ISLAND VENTILATION OPENINGS
A minimum of two ventilation openings totalling 30 in² [194 cm²] must be provided for your
enclosure (island). Three openings are preferred at left and right sides, as well as the back. These
openings are required to safely dissipate gas vapors if there is a leak in your enclosure. The
ventilation openings should be a 1-2” [3-5 cm] off the floor.
W
2.5
6.4
MIN.
18.8
47.8
36.0
91.4
REF.
H
5.25
13.3
MIN.
30.0
76.2
10 in² (64.5 cm²) MIN.
VENTILATION
OPENING ON
BOTH SIDES
AND REAR
2 OPENINGS
FOR GAS &
ELECTRICAL
OPENING FOR
ACCESS DOORS
FINISHED
COUNTERTOP
1.2
3
1.5
3.8
.8
2.1
D
TOP VIEW
3.5" [8.9] SQUARE
OPENING FOR
GAS SUPPLY
3.5" [8.9] SQUARE
OPENING FOR
ELECTRICAL
TYPICAL ISLAND
INSTALLATION
(36" GRILL SHOWN)
.56
1.4
NOTCH
1.00
2.5
MAX.
COUNTERTOP
OVERHANG
LAYOUT FOR
NON-COMBUSTIBLE
ENCLOSURE (ISLAND)
DIMENSIONS IN [ ] ARE IN CM.
BUILT-IN DIMENSIONS:
©2019 Hestan Commercial Corporation
13
EN
W
2.5
6.4
MIN.
18.8
47.8
36.0
91.4
REF.
4.5
11.4
MIN.
H
30.0
76.2
10 in² (64.5 cm²) MIN.
VENTILATION
OPENING ON
BOTH SIDES
AND REAR
2 OPENINGS
FOR GAS &
ELECTRICAL
OPENING FOR
ACCESS DOORS
FINISHED
COUNTERTOP
4.2
10.6
3.1
7.9
3.8
9.7
1.5
3.8
D
TOP VIEW
3.5" [8.9] SQUARE
OPENING FOR
GAS SUPPLY
3.5" [8.9] SQUARE
OPENING FOR
ELECTRICAL
TYPICAL ISLAND
INSTALLATION WITH
INSULATION JACKET
(36" GRILL SHOWN)
INSULATION
JACKET
1.0
2.5
MAX.
COUNTERTOP
OVERHANG
DIMENSIONS IN [ ] ARE IN CM.
LAYOUT FOR
COMBUSTIBLE
ENCLOSURE (ISLAND)
WITH INSULATION JACKET
36.0
91.4
REF.
8 MIN.
20.3
FRONT VIEW
10 in² (64.5 cm²) MIN.
VENTILATION
OPENING ON
BOTH SIDES
AND REAR
120VAC - 15AMP
GFCI PROTECTED
OUTLET
FINISHED
COUNTERTOP
2.50
6.4
*
3.25
8.3
23.38
59.4
*
30.0
76.2
*
5.25
13.3
7.63
19.4
27.37
69.5
SIDE VIEW
OPTIONAL
CABINET
AGLP36
10" X 11" [25 X 28]
ELECTRICAL BOX
LOCATED ON INSIDE
REAR WALL OF
ENCLOSURE
30" [76.2 cm] island depth recommended to allow for clearance
at rear of grill for opening of hood. Assuming 2.50" [6.4 cm]
construction elements (studs) in island, electrical box mounts to
rear wall of island and is 3.25" [8.3 cm] deep. Certain cabinets
(such as AGLP36) installed beneath the grill require clearance
so as to not interfere with the electrical box.
*
-
INSTALLATION
(continued)
©2019 Hestan Commercial Corporation
14
EN
INSTALLATION
(continued)
34.6”
[87.9]
NON-COMBUSTIBLE
CONSTRUCTION
ISLAND VENT
OPENINGS
W
DUCT
OUTLETS
NOTES:
* SHADED AREA INDICATES WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* "W" IS THE WIDTH OF THE GRILL.
NON-COMBUSTIBLE CONSTRUCTION ONLY
(HESTAN GRILL SHOWN)
18”
[45.7]
27.4”
[69.7]
18.3”
[46.5]
30”
[76.2]
REF.
5”
[12.3]
MIN.
12”
[30.5]
12”
[30.5]
6”
[15.1]
6”
[15.1]
30”
[76.2]
36”
[91.4]
REF.
GRILL
WIDTH
RECOMMENDED
VENT HOOD
30" [76.2]
GVP42
36" [91.4]
GVP48
42" [106.7]
GVP54
Fig. 1
12”
[30.5]
SUPPLEMENTARY VENTILATION
In certain installations, such as an island located against your home or other structure, or perhaps
a short roof overhang above your grill, a “range-hood” style ventilation unit may be desirable to
direct smoke and grease away from those structures. In these cases, a Hestan Pro Canopy vent
hood is recommended. See table in the image below to select the appropriate vent hood for your
grill model.
FOR NON-COMBUSTIBLE LOCATIONS ONLY!! The vent hood is wall-mounted and must
NOT be installed on or next to unprotected combustible construction. A minimum clearance to
vertical combustible material, such as adjacent walls, is 12” [30 cm] on the sides of the appliance
(see below). Complete installation details are provided with the hood. Duct covers are also
available to conceal the ductwork and wiring above the vent.
©2019 Hestan Commercial Corporation
15
EN
GAS CONNECTIONS
GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order
to establish the availability of an adequate supply of gas (NG or LP). If it is a new installation,
have the gas authorities or supplier check the meter size and piping to assure that the unit is
supplied with the necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance
installer.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as
a means of isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been
purged so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners.
Use pipe joint compound / thread sealant approved for natural and LP gases.
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY. Before proceeding,
ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas
type will result in poor performance and increased risk of damage or injury. Gas type and gas
consumption (BTU per hour) for each burner type is shown on the rating label affixed to the
underside of the drip tray.
Installation of this cooking appliance must be made in accordance with local codes. In the
absence of local codes, this unit should be installed in accordance with the National Fuel Gas
Code No.
Z223.1/ NFPA 54
, Natural Gas and Propane Installation code
CSA B149-1
, or Propane
Storage and Handling Code B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONVERSION KITS
Gas conversion kits are available from your Hestan dealer should you need to convert an LP unit
to NG, or vice-versa.
HIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. [610 m] or more above sea level, your grill will require
different orifices for proper combustion and performance. High altitude kits are available
through Hestan Customer Service. Please have your model and serial number information ready
when you call.
FREE-STANDING GRILL CONNECTION TO A STATIONARY SUPPLY
Natural Gas (NG) units, or propane (LP) units mounted on a cart and connected to a stationary
gas supply outside the grill must be connected using a 10 ft. approved gas hose. This hose may be
purchased as an accessory.
When routing the hose behind your grill, be careful not to roll over the hose, or place it in an area
of high foot traffic which could create a tripping hazard. Make sure there are no sharp bends in
the hose. Periodically check the hose for scratches, nicks, brittleness, cracking, which could all
lead to a gas leak. Check for gas leaks if you ever smell gas (see LEAK TESTING on page 18). As
an added safety measure, shut off the gas supply after each grill use. Do not push excess hose
length back into the rear access hole of the grill cart. There is not enough room inside the unit
and the hose would get kinked or damaged by cart movement.
©2019 Hestan Commercial Corporation
16
EN
GAS CONNECTION - NATURAL GAS (NG)
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply
pressure is adequate. Use only the gas pressure regulator supplied with this appliance. This
regulator is set for a supply (inlet) pressure of 7-14 inch WC [1.74-3.48 kPa] to maintain 4 inch
WC [1.00 kPa] nominal outlet (manifold) pressure. Use a minimum 1/2” ID flex hose to prevent
gas starvation. Ensure that the service pipe supplying the appliance is fitted with a shut-off valve
conveniently positioned and easily accessible as an emergency gas shut-off.
Your Hestan grill for use with Natural Gas is supplied with its own regulator which MUST be
installed. If this regulator needs to be replaced, use only the type specified by Hestan for this
appliance.
To connect the regulator / hose assembly follow the next steps:
1. Locate the regulator and gas connection point in the rear right side of your grill (in cart-
mounted models, remove the rear panel to gain access).
2. Install the natural gas regulator as shown. Connect gas supply using a minimum 1/2”
diameter flexible (semi–rigid) stainless steel gas hose, no more than 48” in length. The hose
as well as the connectors must comply with the
Standard for Connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor
installation. Use the appropriate thread sealant on all connections.
3. Proceed to LEAK TESTING section.
1/2” ID FLEX HOSE
& NIPPLE
(SUPPLIED BY CUSTOMER)
NAT GAS
REGULATOR
(SHIPPED LOOSE)
INCOMING
NAT GAS SUPPLY
SHUTOFF VALVE
(SUPPLIED BY CUSTOMER)
TYPICAL HESTAN GRILL
(36” MODEL SHOWN)
GAS CONNECTIONS
(continued)
©2019 Hestan Commercial Corporation
17
EN
GAS CONNECTION - LIQUID PROPANE (LP) CYLINDER
Your Hestan grill for use with LP gas is supplied with a two-stage regulator/hose assembly for
connection to a standard 20 lb. LP gas cylinder. This assembly must be used WITHOUT alteration. If
this assembly needs to be replaced, contact your Hestan dealer for genuine replacement P/N 014309.
NOTE: To ensure proper heating performance of this appliance, verify that the supply (inlet)
pressure is adequate. Use only the gas pressure regulator supplied with this appliance. This regulator
is set to maintain 10 inch WC [2.49 kPa] nominal outlet (manifold) pressure.
To connect the regulator / hose assembly follow these steps:
1. Locate the regulator and gas connection point in the rear right side of your grill (in cart-mounted
models, remove the rear panel to gain access).
2. Connect the 3/8” Flare (compression flare fitting) X 1/2” NPT female adapter to the grill manifold
pipe as shown. Connect the regulator/hose assembly to the adapter.
3. Connect the regulator/hose assembly to a standard 20 lb. LP cylinder. The hose as well as the
connectors must comply with the
Standard for Connectors for Outdoor Gas Appliances and
Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation. Use the
appropriate thread sealant on all thread connections.
4. Proceed to LEAK TESTING section.
GAS CONNECTION - LP PIPED SYSTEMS
An LP piped system is one with a large central LP tank that feeds an entire household. These
systems are normally equipped with a high pressure regulator by the large LP tank, and low
pressure regulators close to the home. The gas line connectors must comply with the
Standard for
Connectors for Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and
suitable for outdoor installation. The connection shall be 48” [1.22 m] or less.
Please contact Hestan Customer Service to order an LP Piped System Kit for this unique installation.
Specify if you have a NG or LP grill when ordering the kit.
NOTE: To ensure proper heating performance of this appliance, verify that the supply (inlet)
pressure is adequate (11-14 inch WC [2.74-3.48 kPa] pressure is preferred) to maintain 10 inch WC
[2.49 kPa] nominal outlet (manifold) pressure.
TYPICAL HESTAN GRILL
(36” MODEL SHOWN)
ADAPTER, 3/8 FLARE
X 1/2 NPT FEMALE
(SHIPPED LOOSE)
20lb LP TANK
(SUPPLIED BY CUSTOMER)
2-STG. LP
REGULATOR / HOSE
ASSEMBLY
GAS CONNECTIONS
(continued)
©2019 Hestan Commercial Corporation
18
EN
LP TANK RESTRAINT
If you purchased a Hestan Grill on a cart, be sure to restrain the LP cylinder by securing it with
the retention bolt on the slide-out tray as shown below. It is important the tank does not fall
over or stretch the hose which could cause a gas leak.
LEAK TESTING
GENERAL
Although all gas connections on your Hestan grill are leak tested at the factory prior to
shipment, a complete gas tightness check must be performed at the installation site due to
possible movement in shipment, or excessive pressure unknowingly being applied to parts of the
unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is
detected.
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing
purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.
2-STAGE
LP REGULATOR /
HOSE ASSY.
TANK
RETENTION
BOLT
SLIDE-OUT
TANK TRAY
20 LB.
LP TANK
(SUPPLIED BY
CUSTOMER)
GAS CONNECTIONS
(continued)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Hestan GABR36-LP-OR Le manuel du propriétaire

Catégorie
Barbecues
Taper
Le manuel du propriétaire

dans d''autres langues