RAIS Rina 90 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur

Ce manuel convient également à

1
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
USER MANUAL
MANUAL D’UTILISATEUR
GEBRUIKERSHANDLEIDING
RAIS Rina
RAIS Viva
RAIS Juno
N
O
R
D
I
S
K
M
I
L
J
Ø
M
Æ
R
K
N
I
N
G
5
7
8
0
0
5
EN 13240:2001+A2:2004
Raumheizer für feste Brennstoffe
Appliance fired by wood
Poêle pour combustibles solides
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
Certification
110-0369/TG20196
VKF-NR:
22767
Typ FC
41x FC51x
15a B-VG
EC.NO: 131
AFSTAND TIL BRÆNDBART, BAGVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, HINTEN
DISTANCE TO COMBUSTIBLE BACK WALL
DIST. ENTRE COMPOSANTS COMBUSTIBLES, ARRIÈRE
AFSTAND TIL BRÆNDBART, SIDEVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, SEITE
DISTANCE TO COMBUSTIBLE SIDE WALL
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, COTÉ
AFSTAND TIL BRÆNDBART, MØBLERING
ABSTAND VORNE ZU BRENN
BAREN MÖBELN
DISTANCE TO FURNITURE AT THE FRONT
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, DEVANT
CO EMISSION (REL. 13% O
2)
CO EMISSION IN DEN VERBRENNUNGSPRODUKTEN (BEI 13%O
2)
EMISSION OF CO IN COMBUSTION PRODUCTS (AT 13%O
2)
EMISSION CO DANS LES PRODUITS COMBUSTIBLES (À 13%O
2)
NOMINEL EFFEKT / HEIZLEISTUNG /
THERMAL OUTPUT / PUISSANCE CALORIFIQUE:
RØGGASTEMPERATUR / ABGASTEMPERATUR /
FLUE GAS TEMPERATURE / TE
MPÉRATURE DES GAZ DE FUMÉE:
VIRKNINGSGRAD / ENERGIEEFFIZIENZ /
ENERGY EFFIENCY /EFFICACITÉ ÉNERGÉTIQUE:
DK: Brændsel (Brug kun anbefalede brændsler) Følg instrukserne i brugermanualen.
Anordningen er egnet til røggassamleledning og intervalfyring.
DE: Hinweis: Lesen und befolgen Sie die Bedienungsanleitung.
Zeitbrandfeuerstätte. Nur empfohlene Brennstoffe einsetzen.
UK: Fuel types (only recommended)
Follow the installation and
operating instruction manual. Intermittent operation.
F: Remarque: Veuillez lire et observer les instructions du mode d'emploi.
Foyer à durèe de combustion limitèe, homologué pour cheminée à
connexions multiples. Utiliser seulement les combustibles recommandés.
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 F
rederikshavn
STØV / STAUB /
DUST / POUSSIÈRES:
DK: 11 mg/Nm3 / DE: 11 mg/Nm3
UK: 11 mg/Nm3 / FR: 11 mg/Nm3
DK: 271°C / DE: 271°C
UK: 271°C / FR: 271°C
DK: 4 kW / DE: 4 kW
UK: 4.6 kW / FR: 4 kW
DK: 79% / DE: 79%
UK: 79% / FR: 79%
DK: BRÆNDE
DE: HOLZ
UK: WOOD
FR: BOIS
DK:150 mm/SE BRUGERVEJLEDNING
DE:150 mm/SIEHE BEDIENUNGSANLEITUNG
UK:150 mm/SEE USER MANUAL
FR:150 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:3
50 mm/SE BRUGERVEJLEDNING
DE:350 mm/SIEHE BEDIENUNGSANLEITUNG
UK:350 mm/SEE USER MANUAL
FR:350 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:700 mm/SE BRUGERVEJLEDNING
DE:700 mm/SIEHE BEDIENUNGSANLEITUNG
UK:700 mm/SEE USER MANUAL
FR:700 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: 0,1%
DE: 0,1% / 1250 mg/nm3
UK: 0,1%
FR: 0,1%
CE Label:
RINA 90
RINA 90 Classic
RINA SST
RINA SST Classic
14
RINA 90 / RINA 90 Classic / RINA SST / RINA SST Classic
UK - USER MANUAL ............................................................2-35
FR - MANUEL D’UTILISATEUR ...........................................36-65
FL - GEBRUIKERSHANDLEIDING ........................................66-94
DoP Declaration of Performance ................................................96
Rina 90/Rina SST
Manufacturer’s plate, Plaque signalétique, Merkplaatje
EN 13240:2001+A2:2004
Raumheizer für feste Brennstoffe
Appliance fired by wood
Poêle pour combustibles solides
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
Certification
110-0369/TG20196
15a B-VG
EC.NO: 131
VKF-NR:
22767
Typ FC41x FC51x
AFSTAND TIL BRÆNDBART, BAGVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, HINTEN
DISTANCE TO COMBUSTIBLE BACK WALL
DIST. ENTRE COMPOSANTS COMBUSTIBLES, ARRIÈRE
AFSTAND TIL BRÆNDBART, SIDEVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, SEITE
DISTANCE TO COMBUSTIBLE SIDE WALL
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, COTÉ
AFSTAND TIL BRÆNDBART, MØBLERING
ABSTAND VORNE ZU BREN
NBAREN MÖBELN
DISTANCE TO FURNITURE AT THE FRONT
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, DEVANT
CO EMISSION (REL. 13% O
2)
CO EMISSION IN DEN VERBRENNUNGSPRODUKTEN (BEI 13%O
2)
EMISSION OF CO IN COMBUSTION PRODUCTS (AT 13%O
2)
EMISSION CO DANS LES PRODUITS COMBUSTIBLES (À 13%O
2)
NOMINEL EFFEKT / HEIZLEISTUNG /
THERMAL OUTPUT / PUISSANCE CALORIFIQUE:
RØGGASTEMPERATUR / ABGASTEMPERATUR /
FLUE GAS TEMPERATURE / T
EMPÉRATURE DES GAZ DE FUMÉE:
VIRKNINGSGRAD / ENERGIEEFFIZIENZ /
ENERGY EFFIENCY /EFFICACITÉ ÉNERGÉTIQUE:
DK: Brug kun anbefalede brændsler. Følg instrukserne i
brugermanualen. Anordningen er egnet til røggassamleledning og intervalfyring.
DE: Lesen und befolgen Sie die Bedienungsanleitung.
Zeitbrandfeuerstätte. Nur empfohlene Brennstoffe einsetzen.
UK: Fuel types (only recommended). Follow the instal
lation and
operating instruction manual. Intermittent operation.
F: Veuillez lire et observer les instructions du mode d'emploi.
Foyer à durèe de combustion limitèe, homologué pour cheminée à
connexions multiples. Utiliser seulement les combustibles recommandés.
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
STØV / STAUB /
DUST / POUSSIÈRES:
DK: 11 mg/Nm3 / DE: 11 mg/Nm3
UK: 11 mg/Nm3 / FR: 11 mg/Nm3
DK: 271°C / DE: 271°C
UK: 271°C / FR: 271°C
DK: 4 kW / DE: 4 kW
UK: 4.6 kW / FR: 4 kW
DK: 79% / DE: 79%
UK: 79% / FR: 79%
DK: BRÆNDE
DE: HOLZ
UK: WOOD
FR: BOIS
DK:100 mm/SE BRUGERVEJLEDNING
DE:100 mm/SIEHE BEDIENUNGSANLEITUNG
UK:100 mm/SEE USER MANUAL
FR:100 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:350 mm/SE BRUGERVEJLEDNING
D
E:350 mm/SIEHE BEDIENUNGSANLEITUNG
UK:350 mm/SEE USER MANUAL
FR:350 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:700 mm/SE BRUGERVEJLEDNING
DE:700 mm/SIEHE BEDIENUNGSANLEITUNG
UK:700 mm/SEE USER MANUAL
FR:700 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: 0,1%
DE: 0,1% / 1250 mg/nm3
UK: 0,1%
FR: 0,1%
CE Label:
VIVA 98
VIVA 98 Classic
VIVA 120
VIVA 120 Classic
JUNO
JUNO Classic
14
VIVA 98 / VIVA 98 Classic / VIVA 120 / VIVA 120 Classic / JUNO / JUNO Classic
EN 13240:2001+A2:2004
Raumheizer für feste Brennstoffe
Appliance fired by wood
Poêle pour combustibles solides
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
Certification
110-0369/TG20196
VKF-NR:
22767
Typ FC
41x FC51x
15a B-VG
EC.NO: 131
AFSTAND TIL BRÆNDBART, BAGVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, HINTEN
DISTANCE TO COMBUSTIBLE BACK WALL
DIST. ENTRE COMPOSANTS COMBUSTIBLES, ARRIÈRE
AFSTAND TIL BRÆNDBART, SIDEVÆG
ABSTAND ZU BRENNBAREN BAUTEILEN, SEITE
DISTANCE TO COMBUSTIBLE SIDE WALL
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, COTÉ
AFSTAND TIL BRÆNDBART, MØBLERING
ABSTAND VORNE ZU BRENN
BAREN MÖBELN
DISTANCE TO FURNITURE AT THE FRONT
DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, DEVANT
CO EMISSION (REL. 13% O
2)
CO EMISSION IN DEN VERBRENNUNGSPRODUKTEN (BEI 13%O
2)
EMISSION OF CO IN COMBUSTION PRODUCTS (AT 13%O
2)
EMISSION CO DANS LES PRODUITS COMBUSTIBLES (À 13%O
2)
NOMINEL EFFEKT / HEIZLEISTUNG /
THERMAL OUTPUT / PUISSANCE CALORIFIQUE:
RØGGASTEMPERATUR / ABGASTEMPERATUR /
FLUE GAS TEMPERATURE / TE
MPÉRATURE DES GAZ DE FUMÉE:
VIRKNINGSGRAD / ENERGIEEFFIZIENZ /
ENERGY EFFIENCY /EFFICACITÉ ÉNERGÉTIQUE:
DK: Brug kun anbefalede brændsler. Følg instrukserne i
brugermanualen. Anordningen er egnet til røggassamleledning og intervalfyring.
DE: Lesen und befolgen Sie die Bedienungsanleitung.
Zeitbrandfeuerstätte. Nur empfohlene Brennstoffe einsetzen.
UK: Fuel types (only recommended). Follow the install
ation and
operating instruction manual. Intermittent operation.
F: Veuillez lire et observer les instructions du mode d'emploi.
Foyer à durèe de combustion limitèe, homologué pour cheminée à
connexions multiples. Utiliser seulement les combustibles recommandés.
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
STØV / STAUB /
DUST / POUSSIÈRES:
DK: 11 mg/Nm3 / DE: 11 mg/Nm3
UK: 11 mg/Nm3 / FR: 11 mg/Nm3
DK: 271°C / DE: 271°C
UK: 271°C / FR: 271°C
DK: 4 kW / DE: 4 kW
UK: 4.6 kW / FR: 4 kW
DK: 79% / DE: 79%
UK: 79% / FR: 79%
DK: BRÆNDE
DE: HOLZ
UK: WOOD
FR: BOIS
DK:100 mm/SE BRUGERVEJLEDNING
DE:100 mm/SIEHE BEDIENUNGSANLEITUNG
UK:100 mm/SEE USER MANUAL
FR:100 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:400 mm/SE BRUGERVEJLEDNING
DE:
400 mm/SIEHE BEDIENUNGSANLEITUNG
UK:400 mm/SEE USER MANUAL
FR:400 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:650 mm/SE BRUGERVEJLEDNING
DE:650 mm/SIEHE BEDIENUNGSANLEITUNG
UK:650 mm/SEE USER MANUAL
FR:650 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK: 0,1%
DE: 0,1% / 1250 mg/Nm3
UK: 0,1%
FR: 0,1%
CE Label:
VIVA 98 G
VIVA 98 G Classic
VIVA 120 G
VIVA 120 G Classic
JUNO G
JUNO G Classic
14
VIVA 98 G / VIVA 98 G Classic / VIVA 120 G / VIVA 120 G Classic / JUNO G / JUNO G Classic
Viva 98G / Viva 120G / Juno G
Manufacturer’s plate, Plaque signalétique, Merkplaatje
Viva 98 / Viva 120 / Juno
Manufacturer’s plate, Plaque signalétique, Merkplaatje
Using the wood burning stove
Utilisation du poêle
Gebruik van de kachel
Adjustment of the air damper
Réglage du volet d’air
Insellen van de klep
Position 1
Position 1
Stand 1
Position 2
Position 2
Stand 2
Position 3
Position 3
Stand 3
The oven is wrapped in packaging that is recyclable. This must
be disposed of according to national rules regarding the dis-
posal of waste.
The glass can not be reused.
The glass should be discarded along with the residual waste
from
ceramics and porcelain.
Pyrex glass has a higher melting temperature and therefore can
not be reused.
If discarded you make an important positive contribution to
the environment.
FIRE ENVIRONMENTALLY FRIENDLY!
5 Eco-friendly advices for sensible heating
- common sense both environmentally and economically.
1. Effective lighting. Use dry brushwood, kindling and possible a piece of news
paper. Open the air damper, so plenty of air is fed to the stove and the gases
from the heated wood can burn rapidly.
2. Light the fire with only little wood at a time - this gives the best combustion.
Remember plenty of air for every time new wood is added.
3. When the flames are diminished, adjust the air damper so that the air supply
is reduced
4. When only glowing embers remain, air flow can be reduced further, so heat-
ing demand is just covered. With a lower air supply the charcoal will burn
slower and the heat loss through the chimney is reduced.
5. Use only dry wood - ie wood with a humidity of 15 to 22 percent.
We cannot be held responsible for any misprints.
3
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
RAIS Rina - RAIS Viva - RAIS Juno
Revision: 6
Date : 11th November 2013
INTRODUCTION .................................................................................................................................. 4
WARRANTY ......................................................................................................................................... 4
SPECIFICATIONS .................................................................................................................................. 5
INSTALLATION INSTRUCTIONS .............................................................................................................. 6
CONVECTION ...................................................................................................................................... 7
CHIMNEY ........................................................................................................................................ 7-8
INSTALLATION ................................................................................................................................... 8-9
CHANGE OF CHIMNEY CONNECTION ................................................................................................ 10
INSTALLATION DISTANCE IN CASE OF COMBUSTIBLE WALL .......................................................... 11-16
NORMAL SET-UP - CORNER SETTING - RINA ....................................................................................... 12
NORMAL SET-UP - CORNER SETTING - VIVA / JUNO .......................................................................... 13
CORNER SETTING 45° - RINA ............................................................................................................ 14
CORNER SETTING 45° - VIVA / JUNO ................................................................................................. 15
360° SWIVEL BASE - VIVA / JUNO ...................................................................................................... 16
INSTALLATION DISTANCE IN CASE OF NON-COMBUSTIBLE WALL ...................................................... 17
FOR THE INSTALLER ........................................................................................................................... 18
OPERATING INSTRUCTIONS ................................................................................................................ 19
FUEL ........................................................................................................................................... 19-20
DRYING AND STORAGE .................................................................................................................... 21
REGULATION OF COMBUSTION AIR .................................................................................................. 21
ROOM VENTILATION AND STOVES .................................................................................................... 21
USING THE WOOD BURNING STOVE ................................................................................................ 22
ADJUSTMENT OF AIR DAMPER ......................................................................................................... 22
CONTROL ......................................................................................................................................... 22
FIRST USAGE .................................................................................................................................... 22
LIGHTING AND FUELLING ................................................................................................................... 23
CLEANING AND CARE ..................................................................................................................... 25
CLEANING OF THE FLUE WAYS .......................................................................................................... 25
INTERRUPTION OF OPERATION ......................................................................................................... 26
ACCESSORIES AND SPARE PARTS ....................................................................................................... 27
SPARE PART DIAGRAMS RAIS RINA 90 .............................................................................................. 27
SPARE PART DIAGRAMS RAIS VIVA 98 WITH SIDE GLASS ................................................................... 28
SPARE PART DIAGRAMS RAIS VIVA 98 WITHOUT SIDE GLASS ............................................................ 29
SPARE PART DIAGRAMS RAIS VIVA 120 WITH SIDE GLASS ................................................................. 30
SPARE PART DIAGRAMS RAIS VIVA 120 WITHOUT SIDE GLASS .......................................................... 31
SPARE PART DIAGRAMS RAIS JUNO WHIT SIDE GLASS ....................................................................... 32
SPARE PART DIAGRAMS RAIS JUNO WHITOUT SIDE GLASS ................................................................ 33
INSTALLATION OF SOAPSTONE - RINA ................................................................................................ 34
4
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
Introduction
Thank you for purchasing a RAIS wood burning stove. These appliances have been ap-
proved by SCA/HETAS Ltd as intermittent operating appliances for burning wood logs
only.
A RAIS wood burning stove is more than just a heat source: it also shows that you care
about design and quality in your home.
To make the most of your wood burning stove it is important that you read the manual
thoroughly, before installing and using it.
In the case of warranty coverage, and for general queries regarding your wood burning
stove, it is important that you know the stove’s production number. We therefore recom-
mend that you note down the number in the table below. The production number is
located on the back of the stove at the bottom.
Warranty
Your RAIS wood burning stove comes with a 5 year warranty. The warranty, however,
does not cover heat-insulating materials, glass and seals.
Any alterations made to the stove will void the warranty.
Date: Distributor:
5
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Specifications
Rais Rina 90
Rais Viva 98
Rais Viva 98 G
Rais Viva 120
Rais Viva 120 G
Rais Juno
Rais Juno G
Nominal output (kW):
4.6 4.6 4.6 4.6
Min./Max. output (kW):
2-6 2-6 2-6 2-6
Heating area (m
2
):
30-90 30-90 30-90 30-90
Stove’s width/depth/height (mm):
461-410-900 Ø440-980 Ø440-1200 Ø470-1660
Combustion chamber’s width/depth/height (mm):
295-225-393
295-225-393
320-225-393
295-225-393
320-225-393
295-225-393
320-225-393
Recommended amount of wood when fuelling (kg):
(Distributed on 2-3 logs of wood of approx. 25 cm)
1,2 1,2 1,2 1,2
Min.uptake / min. draught (Pascal):
-12 -12 -12 -12
Weight (kg):
105 98 104 356
Efficiency (%):
79 79 79 79
CO-emission at 13% O
2
(%) 0.10 0.10 0.10 0.10
Particles after NS3058/3059 (g/kg):
1.39 1.39 1.39 1.39
Dust measured according to Din+ (mg/Nm³):
11 11 11 11
Smoke gas mass flow (g/s):
4 4 4 4
Smoke gas temperature (°C):
271 271 271 271
Intermittent operation:
Refuelling should be undertaken within 3 hours
6
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
Installation instructions
The following pages give instructions for the safe and proper installation of this heating
appliance in the UK. These instructions cover the basic principles of installation, although
detail may need slight modification to suit particular local site conditions. In all cases the
installation must comply with current UK Building Regulations, Local Authority Byelaws
and other specifications or regulations as they affect the installation of the stove. Please
note that it is a legal requirement under England and Wales Building Regulations that
the installation of the stove is either carried out under Local Authority Building Control
approval or is installed by a Competent Person registered with a Government approved
Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of their Reg-
istered Competent Persons can be found on their website at www.hetas.co.uk.
It should be noted that the current Building Regulations requirements are given in Ap-
proved Document J. These requirements may also be met by adopting the relevant recom-
mendations given in British Standards BS 8303 and BS EN 15287-1.
WARNING: Health and Safety Advice Notice
The installation of this heating appliance is governed by the Health and Safety at Work
Act 1974. It is the responsibility of the installer to ensure that all requirements of this Act
are met during the installation works. Attention is drawn in particular to the following:
Handling:
The appliance is a heavy item and adequate facilities must be available for loading,
unloading and site handling.
Fire Cement:
Some types of fire cement are caustic and should not be allowed to come into con-
tact with the skin. Protective gloves should be worn when handling fire cement. In
case of contact with the skin wash immediately with plenty of water.
Asbestos:
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in
the course of installation then please seek specialist guidance and use appropriate
protective equipment.
Metal Parts:
When installing or servicing this stove care should be taken to avoid the possibility
of personal injury.
Important Warning –Preparatory Work and Safety Checks:
This stove must not be installed into a chimney that serves any other heating appli-
ance.
It’s recommendet not have an extractor fan fitted in the same room as the stove as
this can cause the stove to emit fumes into the room.
If this appliance is installed into an existing chimney, the chimney must first be swept
and examined for soundness and suitability before the appliance is installed (see also
section headed “Chimney”).
7
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Convection
RAIS stoves are convection stoves. This means that the stove’s back and side panels are
not over-heated. Convection means that there is a circulation of air, which ensures that
the heat is distributed more evenly throughout the entire room. The cold air is sucked in
at the base of the stove up through the convection channel, which runs along the stove’s
combustion chamber. The heated air pours out at the top of the stove, which ensures a
circulation of warm air throughout the room.
The stoves are equipped with a “cold” lever – RAIS special feature – which means you
could almost do away with gloves. Be aware, however, that all exterior surfaces become
hot during use - so take extreme care.
Chimney
The chimney is the driving force which makes the stove function. In order for the stove to
perform satisfactorily the chimney height must be sufficient to ensure the correct draught
of 14 to 18 Pa so as to clear the products of combustion and prevent problems of smoke
emanating into the room when firing.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet
of the stove to the top of the chimney should be satisfactory. Alternatively the calcula-
tion procedure given in BS 5854:1980 may be used as the basis for deciding whether a
particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with
the provisions of Building Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or
other faults which might allow fumes into the house. Older properties, especially, may
have chimney faults or the cross section may be too large i.e. more than 230 mm x 230
mm. Remedial action should be taken, if required, seeking expert advice, if necessary. If it
is found necessary to line the chimney then a flue liner suitable for solid fuel must be used
in accordance with Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immedi-
ately before installation of the stove. If the stove is fitted in place of an open fire then the
chimney should be swept one month after installation to clear any soot falls which may
have occurred due to the difference in combustion between the stove and the open fire.
If there is no existing chimney then either a prefabricated block chimney in accordance
with Building Regulations Approved Document J or a twin walled insulated stainless steel
flue to BS 1856-1can be used. These chimneys must be fitted in accordance with the
manufacturer’s instructions and Building Regulations.
8
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not
suitable for using for the complete chimney. The chimney and connecting fluepipe must
have a minimum diameter of 150 mm and its dimension should be not less than the size
of the outlet socket of the stove which is 150 mm in diameter. Any bend in the chimney
or connecting fluepipe should not exceed 45°. 90°bends should not be used.
Combustible material should not be located where the heat dissipating through the walls
of fireplaces or flues could ignite it. Therefore when installing the stove in the presence
of combustible materials due account must be taken of the guidance on the separation
of combustible material given in Building Regulations Approved Document J and also in
these stove instructions.
If it is found that there is excessive draught in the chimney then either an adjustable flue
damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper
should not close off the flue entirely but should in its closed position leave a minimum
continuous opening free area of at least 20 % of the total cross sectional area of the flue
or fluepipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweep-
ing the chimney and connecting fluepipe.
You should also familiarise yourself with the draught conditions for chimneys with 2 flues.
The flue outlet spigot is eiter 150 (6”) mm in diameter, or 129 (5”) mm in diameter.
For strong draughts, the chimney or flue should be fitted with a draught stabiliser. In
which case, it is important to ensure that there is a free flow-through area of minimum
20 cm² when the regulating gate is shut. Otherwise, the fuel energy may not be used
optimally. If, at any time, you are unsure about the condition of the chimney, you should
contact a chimney sweep.
Remember that access to the access door should be kept clear.
Installation
When installing the wood burning stove, there are some rules which MUST be followed:
The stove must be set up and installed in accordance with all current national and local
rules and regulations. Local authorities and a chimney specialist should be contacted prior
to set up.
It is prohibited to carry out unauthorised alterations to the stove.
9
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
There must be plenty of fresh air in the room where the stove is being installed, in order
to ensure proper combustion. Note that any mechanical exhaust ventilation - e.g. an
extraction hood - may reduce the air supply. Any air grates must be placed in such a man-
ner, that the air supply is not blocked.
The floor structure must be able to carry the weight of the wood burning stove, as well as
the weight of a chimney, if necessary.
When you choose where to set up your RAIS wood burning stove, you should consider
the heat distribution to the other rooms. This will enable you to get the best use out of
your stove.
The stove should be set up at a safe distance from inflammable materials.
See the manufacturer’s plate on the wood burning stove
10
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
Change of chimney connection
The stove is delivered ready for top outlet, but may be changed to back outlet in the fol-
lowing way:
Strike out the knock out plate at the rear of stove.
Remove the blanking plate and the packing, and
position them in the hovle at the top. Ensure that the
packing is positioned correctly. Screw all elements
together with the three M6 nuts.
Mount the flue collar, which is found in a bag in the
stove, and the clamp for the upper smoke conductor
with three M6x20 cylinder screws and M6 nuts.
Mount the parts in reverse order.
11
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Installation distance in case of combustible wall
To find out whether the wall next to where the stove is going to be installed is flammable,
you should contact your building contractor or the local building authorities.
The hearth should be able to accommodate the weight of the stove. The chimney must
be independently supported by wall brackets or a ceiling support plate. The weight of the
stove is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construc-
tion that is in accordance with the provisions of the current UK Building Regulations Ap-
proved Document J.
If the stove is to be installed on a wooden floor, it must be covered with a non-combusti-
ble material at least 12 mm thick, in accordance with UK Building Regulations Approved
Document J, to at distance of 300 mm in front of the stove and 150 mm to each side
measuring from the door of the combustion chamber.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of
combustible material given in UK Building Regulations Approved Document J and also in
these stove instructions.
12
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
Normal set-up - corner setting
Rais Rina
A. Distance to furniture 700 mm
Distance to flammable materials:
B. - in front (floor) 300 mm
C. - to the side (floor) 150 mm
D. - to the rear (wall) 150 mm
E. - to the side of the wall 350 mm
13
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Normal set-up - corner setting
Rais Viva/Rais Juno Rais Viva G/Rais Juno G
A. Distance to furniture 700 mm 650 mm
Distance to flammable materials:
B. - in front (floor) 300 mm 300 mm
C. - to the side (floor) 150 mm 150 mm
D. - to the rear (wall) 100 mm 100 mm
E. - to the side of the wall 350 mm 400 mm
14
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
Corner setting 45°
Rais Rina
A. Distance to furniture 700 mm
Distance to flammable materials:
B. - in front (floor) 300 mm
C. - to the side (floor) 150 mm
D. - to the rear (wall) 150 mm
E. - to the side of the wall 350 mm
15
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Corner setting 45°
Rais Viva/Rais Juno Rais Viva G/Rais Juno G
A. Distance to furniture 700 mm 650 mm
Distance to flammable materials:
B. - in front (floor) 300 mm 300 mm
C. - to the side (floor) 150 mm 150 mm
D. - to the rear (wall) 100 mm 250 mm
E. - to the side of the wall 350 mm 400 mm
16
English RAIS - Manual for RAIS Rina, RAIS Viva, RAIS Juno
360° swivel base
Rais Viva/Rais Juno Rais Viva G/Rais Juno G
A. Distance to furniture 700 mm 650 mm
Distance to flammable materials:
B. - to the side (floor) 300 mm 300 mm
17
English RAIS - Manual for RAIS Rina, RAIS Viva , RAIS Juno
Installation distance in case of non-combustible wall
We recommend a minimum distance to non-combustible material of 50 mm (F) for
cleaning considerations.
It should always be possible to access the access door.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107

RAIS Rina 90 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues