Extron DVI DA Manuel utilisateur

Catégorie
Séparateurs vidéo
Taper
Manuel utilisateur
1
DVI DA2 and DVI DA 4 • User Guide
This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Ampliers. Unless stated
otherwise, “distribution amplier” or “the unit” in this guide refer to both models.
About the DVI DA2 and DVI DA4
The Digital Visual Interface (DVI) Distribution Ampliers (DAs) have one input and either two (DVI DA2) or four (DVI DA4) outputs.
Output 1 for each model is for a local monitor and is used for Digital Display Channel (DDC) reference.
Both distribution ampliers accept one single link DVI-D input and drive two (DVI DA2) or four (DVI DA4) single link DVI-D output
signals.
12V
0.4A MAX
POWER
DVI-D INPUT DVI-D OUTPUT
1 2
DVI DA2
Ext
ron
DV
I DA 2
Dist
ribution Amplier
PC
w/ DVI Output
Local Monitor
Flat Panel Display
w/ DVI Input
Figure 1. DVI DA2 Application Diagram
DVI DA2 and DVI DA4 Features
External power supply — The DVI DA2 and DVI DA4 are powered by an external 12VDC power supply (provided with the
units).
DVI-D input — Both distribution ampliers accept one single link DVI-D input with a range of resolutions up to 1920 x 1200
or 1080p @ 60 Hz.
Input equalization — Input Equalization (EQ) conditions the input signals to ensure the integrity of the signals delivered to
the output devices.
DVI-D outputs — The units drive two (DVI DA2) or four (DVI DA4) single link DVI-D output signals.
DDC routing to the local monitor — Output 1 is used as a DDC reference and is labeled “Local Monitor” for easy reference.
The video source uses the bidirectonal DDC to communicate with the local monitor, which allows the source to determine the
resolution and refresh rate of the signal that it sends.
NOTES:
Since output 1 is used as the reference, all other display devices must be capable of handling resolutions equal to or
greater than that of the local monitor.
The actual signal transmission distance can vary greatly and depends on signal resolution, cable type, cable quality,
graphics card, and the display used in the system.
Versatile mounting options — Both units are 1U high, 3 inches (7.62 cm) deep, and 1/2rack (8.7 inches or 22.1 cm) wide,
allowing them to be conveniently mounted in a rack, mounted under a desk, or set on a tabletop.
figure 1
2
Installation Overview
Both distribution ampliers can be placed on tabletops, or mounted under furniture or in racks by following these steps:
1. Turn off all electrical equipment. Make sure that the input sources, the DA and the output display(s) are all turned off and all
power sources and signal cables are disconnected.
2. Mount the unit (see Mounting page 5).
3. Connect the cables (see DVI Connections on page 3).
4. Plug in the power supply (see page 3), then turn on the display devices and input devices.
Front Panel Features
The front panels of the DVI DA2 and DVI DA4 are identical and shown in the illustration below
DVI DA SERIES
DVI DISTRIBUTION AMPLIFIER
11
Figure 2. DVI DA2 and DVI DA4 Front Panel (both models are identical)
1
LED indicator — On both the DVI DA2 and DVI DA4, the LED indicator lights when the unit is receiving power.
Rear Panel Features
12V
0.4A MAX
POWER
DVI-D INPUT DVI-D OUTPUT
LOCAL MONITOR
12
DVI DA2
12V
0.4A MAX
POWER
DVI-D INPUTDVI-D OUTPUTS
LOCAL MONITOR
1234
DVI DA4
11
2
2 3344
Figure 3. DVI DA2 (top) and DVI DA4 (bottom) Rear Panels
1
Power input (see figure 3) — Connect the provided power supply
DC Power
Input
POWER
12V
0.4A MA
X
Power Supply
Output Cord
SECTION A–
A
RidgesSmooth
AA
DC Power Cord
Captive Screw Connector
Ground
+12 VDC input
G
External Power Supply
(12 VDC, 0.5 A max.)
Ground all
Devices
to the 3.5 mm, captive screw power receptacle.
NOTES:
The length of the exposed wires in the stripping process
is critical. The ideal length is 3/16 inch (5 mm).
If the exposed section is longer, the exposed wires
may touch, causing a short circuit between them.
If it is shorter, the wires can be easily pulled out,
even if tightly fastened by the captive screws.
Do not tin the wires. Tinned wire does not hold its
shape and can become loose over time.
Figure 4. Power Connection
figure 2
figure 3
figure 4
3
ATTENTION:
If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked “Class
2” or “LPS” and rated output 12 VDC, 1.5 A minimum. Always use a power supply provided by or specied by Extron.
Use of an unauthorized power supply voids all regulatory compliance certication and may cause damage to the supply
and the end product.
Si le produit n’est pas fourni avec une source d’alimentation, il doit être alimenté par une source d’alimentation certiée
UL de classe 2 ou LPS, avec une tension nominale 12 Vcc, 1,5 A minimum. Utilisez toujours une source d’alimentation
fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute certication de
conformité réglementaire, et peut endommager la source d’alimentation et l’unité.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power
supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution
Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d’aération ou dans
les cavités murales. La source d’alimentation doit être placée à proximité de l’équipement Extron dans un emplacement
ordinaire soumis à un degré de pollution de catégorie II, solidement xé au rack d’équipement d’une baie technique, d’un
pupitre, ou d’un bureau.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA
70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently xed to
building structure or similar structure.
Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l’électricité (National
Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l’électricité, partie 1, section 16. La source
d’alimentation ne devra pas être xée de façon permanente à la structure de bâtiment ou à d’autres structures similaires.
DVI Connections
2
Input connector (see figure 3 on the previous page) — Connect the input signal to the female DVI connector. The DVI input
signal is equalized to ensure integrity.
3
Output connectors — Connect up to two (DVI DA2) or four (DVI DA4) DVI-D outputs to display devices, using the female DVI
connectors.
NOTE: The outputs are not HDCP compatible.
4
Local Monitor connector — Output 1 (Local Monitor) is used as a Hotplug Detect, a DDC clock, and a DDC data reference.
For the input device to provide a signal at the correct resolution and refresh rate, there must be a display device connected to
output1.
NOTE: Although the source device, local monitor, and remote display devices all connect to the distribution amplifiers
through DVI-I connectors, the DVI DA2 and DVI DA4 are compatible only with single-link DVI-D video signals.
To enable the units to accept sources providing HDMI signals or to provide signals to displays that accept HDMI signals,
use a HDMI to DVI adapter or cable, such as the Extron HDMIF-DVIDM female HDMI to male DVI-D adapter or the Extron
HDMIM-DVI-D M series of male HDMI to male DVI cables.
The input signal is one single link DVI-D with a resolution range up to 1920x1200 or 1080p@ 60 Hz.
Input EQ conditions input signals to ensure the integrity of the signals delivered to the output devices.
NOTES:
The actual signal transmission distance can vary and depends on the signal resolution, cable quality, graphics card, and
display used in the system.
To ensure proper operation, display devices connected to outputs 2 through 4 must be able to handle resolutions equal
or greater than that of the local monitor on output 1.
4
DVI Connector Pin Assignments
The illustration below shows the pin assignments for the male and female DVI-I connectors.
NOTE: Although DVI-I dual link connectors are used, the DVI DA2 and DVI DA4 are compatible only with single-link DVI-D
video signals.
Pin Signal Pin Signal Pin Signal
Three rows of eight holes and two contacts
above and below the "
+
" socket.
DVI-I Dual Link - Female
(analog and digital)
1
9
8
17 24
C3 C4
C1 C2
C5
1 TMDS data 2- 9 TMDS data 1- 17 TMDS data 0-
2 TMDS data 2+ 10 TMDS data 1+ 18 TMDS data 0+
3 TMDS data 2/4
shield
11 TMDS data 1/3
shield
19 TMDS data 0/5
shield
4 TMDS data 4- 12 TMDS data 3- 20 TMDS data 5-
5 TMDS data 4+ 13 TMDS data 3+ 21 TMDS data 5+
6 DDC clock 14 +5V power 22 TMDS clock shield
7 DDC data 15 Ground 23 TMDS clock+
8 Analog vertical sync 16 Hot plug detect 24 TMDS clock1
C1 Unused C3 Unused C5 Unused
C2 Unused C4 Unused
Operation
To operate the unit (see figure 3 and figure 4 on page2):
1. Connect the power supply.
2. Connect and power on Output 1 (Local Monitor) .
3. Connect and power on any other output displays.
4. Connect and power on the source device.
NOTE: Output 1 (Local Monitor) is used as a DDC reference and must be connected to the distribution amplifier before the
source device is powered on. If the source device cannot communicate with the local monitor when it is being powered on,
it may not be able to send a video signal or the signal may have the wrong resolution or refresh rate.
If there are any problems, consult the Troubleshooting section below.
Troubleshooting
No output signal — Check that the front panel LED is lit. If it is not, check the power supply connections to the unit (see
page 4).
No output signal or poor quality signal — Check the integrity of the cabling to output1 (Local Monitor) and ensure that
output 1 is connected to the distribution amplier before powering on the source device.
If the source device cannot communicate with output 1 when it is being powered on, it may not be able to send a video
signal or the signal may have the wrong resolution or refresh rate.
No output signal or poor quality signal — Check the input and output cabling (figure 4 on page2). DVI signals run at
very high frequency and poor connections can cause degradation or loss of the signal, or jitter. To avoid this:
Use only cable that is designed for DVI signals.
Limit or avoid the use of adapters.
Display device shows a flashing black or blue screen, snow or other distortion — A device that is not HDCP compliant
may be receiving HDCP-encrypted signals.
The DVI DA2 and DVI DA4 are not High-Bandwidth Digital Content Protection (HDCP) compliant. They will pass HDCP-
encrypted signals only to the local output device.
Signal on local monitor but not on other displays — Check that all output devices (monitors or projectors) can handle
resolutions equal to or greater than that of the local monitor.
5
68-1376-01 Rev. H
10 18
© 2007-2018 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
Mounting
Attach the four provided rubber feet to the bottom of the unit and place it in any convenient location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of these products in a rack:
1. Elevated operating ambient temperature — If the unit is installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the
equipment in an environment compatible with the maximum ambient temperature (Tma: +122 °F, +50°C) specied by Extron.
2. Reduced air flow — Install the equipment in the rack so that the equipment gets adequate air ow for safe operation.
3. Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous
condition.
4. Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might
have on overcurrent protection and supply wiring. Consider the equipment nameplate ratings when addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply
connections other than direct connections to the branch circuit (such as the use of power strips).
Rack Mounting Procedure
The unit can be mounted on any rack systems. To mount the product on a rack shelf, follow the instructions provided with the
shelf accessories.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the
FCC rules. The ClassA limits provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Extron DVI DA Manuel utilisateur

Catégorie
Séparateurs vidéo
Taper
Manuel utilisateur

dans d''autres langues