Regency Plateau PTO60-LP Guide d'installation

Catégorie
Cheminées
Taper
Guide d'installation

Ce manuel convient également à

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-990a 07/19/11
Owners &
Installation Manual
Tested by: Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Regency Plateau
PTO30 / PTO60
Outdoor Decorative Gas Appliance
WARNING: FOR OUTDOOR USE ONLY
www.regency- re.com
WARNING:
If the information in these instructions
are not followed exactly, a fire
or explosion may result causing
property damage, personal injury or
loss of life.
WARNING - FOR YOUR SAFETY
What to do if you smell gas:
•Shut off gas to the appliance.
•Do not try to light any appliance.
•Extinguish any open ame.
•If odour continues, keep away from the appliance and im-
mediately call your gas supplier or re department.
•Do not touch any electrical switch: do not use any phone
in your building.
•Immediately call your gas supplier from a neighbour's
phone.
•Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the re
department.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
equipment.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
WARNING:
Do not store or use gasoline or other ammable vapours
and liquids in the vicinity of this or any other appliance.
Models: PTO30-NG / PTO30-LP
PTO60-NG / PTO60-LP
2Regency Plateau™ PTO30 Outdoor Gas Fireplace
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space
such as a camper, tent, car or home.
XX
X
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Outdoor Decorative Gas Appliance by REGENCY®. The
Plateau™ PTO30 Outdoor decorative gas appliance has been designed to provide you with all
the warmth and charm of a fi re at the fl ick of a switch. The Plateau™ PTO30 Outdoor Decorative
Gas Appliance has been approved by Warnock Hersey/Intertek for both safety and effi ciency.
As it also bears our own mark, it promises to provide you with economy, comfort and security
for many trouble free years to follow. Please take a moment now to acquaint yourself with these
instructions and the many features of your Regency® decorative gas appliance.
Regency Plateau™ PTO30 Outdoor Gas Fireplace 33
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................4
DIMENSIONS
PTO30 nished table top and Unit Dimensions .............5
PTO60 Unit Dimensions ................................................6
INSTALLATION
Important Message ......................................................7
Before You Start ............................................................7
General Safety Information............................................7
Installation Checklist .....................................................8
Locating Your Outdoor decorative gas appliance ..........8
Minimum Clearances to combustibles ...........................9
Inner Framing dimensions (required) ..........................10
Finishing ......................................................................10
High Elevation .............................................................11
Gas Line Installation ....................................................11
Pilot Adjustment ...........................................................11
Gas Pipe Pressure Testing ..........................................11
886 S.I.T. Valve Description .........................................11
Aeration Adjustment ....................................................11
PTO30 wall switch installation .....................................12
PTO60 wall switch installation .....................................13
Drain Installation (Recommended) ..............................14
Wiring Diagram ............................................................15
PTO60 assembly .........................................................16
PTO30 table top Installation ........................................17
PTO60 table top Installation ........................................18
Glass crystal installation on burner..............................19
Volcanic stone installation on burner ..........................20
Optional Log Set Installation........................................21
Optional glass surround Installation ............................23
OPERATING INSTRUCTIONS
Operating Instructions .................................................24
Lighting Procedure ......................................................24
Shutdown Procedure ...................................................24
First Fire ......................................................................24
Copy of Lighting Plate Instructions ..............................25
MAINTENANCE
Maintenance Instructions.............................................26
Valve assembly replacement .......................................27
PARTS
Parts ............................................................................28
WARRANTY
Limited Warranty: ......................................................31
4Regency Plateau™ PTO30 Outdoor Gas Fireplace
SAFETY LABEL
This is a copy of the label that accompanies each
PTO30 Outdoor decorative gas appliance. We have
printed a copy of the contents here for your review.
NOTE: Regency® units are constantly being
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fi tter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
382
382
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
Listed:
Certified for/Certifi e pour:
Tested to:
OUTDOOR DECORATIVE GAS APPLIANCE /
CANADA and U.S.A.
EXTÉRIEUR DÉCORATIFS APPAREIL À GAZ
(US) / CR97-003 (CAN) / CAN / CGA-2.17-M91
é
ANSI Z21.97-2010
.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
ÉÉ
é
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le
PTO30-LP
PROPANE GAS: Model -LPPTO30
NATURAL GAS: Model PTO30-NG
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minumum input
Altitude
Maximum supply pressure
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit maximum selon
l'altitude
Pression d'allimentation maximum
Pression à la tubulure d' chappement
Calorifique
D bit Calorifique minimum selon
ééé
é
é basse
é
14” WC/C.E. (3.49 kPa)
5" WC/C.E. (1.25 kPa)
WC/C.E.
1.6" WC/C.E. (0.40 kPa)
50,000 Btu/h (14.65 kW)
30,000 Btu/h (8.79 kW)
3.5" (0.87 kPa)
#25 DMS
0-4500 ft/pi (0-1372 m)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit maximum selon
l'altitude
Pression d'allimentation maximum
Pression à la tubulure d' chappement
Calorifique
D bit Calorifique minimum selon
ééé
é
é basse
é
14" WC/C.E. (3.49 kPa)
11” WC/C.E. (2.74 kPa)
WC/C.E.
6.4" WC/C.E. (1.59 kPa)
49,000 Btu/h (14.36 kW)
38,000 Btu/h (11.13 kW)
10” (2.49 k Pa)
#45 DMS
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Maximum supply pressure
Manifold pressure low
Minumum input
Back Wall
A 17” (432mm)
B 17” (432mm)
C 45” (1143mm)
D 1” (25mm)
Side Wall
Ceiling
Unit Base
The installation must conform with local codes or, in the absence of local codes, with The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70. This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, avec CAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54.
L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, avec le Code canadien de l'électricité, CSA C22.1 ou avec le National Electrical Code,ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel du propriétaire pour les détails.
CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod leéPTO30-NG
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS / SI VOUS LE GARDER À L'INTÉRIEUR, DETACHER LE CYLINDRE ET LAISSER À L'EXTÉRIEUR 918-989
PTO30-LP
PTO30-NG
A
C
B
D
4001172
Regency Plateau™ PTO30 Outdoor Gas Fireplace 5
DIMENSIONS
PTO30 FINISHED TABLE TOP AND UNIT DIMENSIONS
20-1/4”
(514mm)
10-3/16”
(258mm)
33-7/16”
(848mm)
12”
(305mm)
14-3/16”
(359mm)
17”
(432mm)
41-1/2”
(1054mm)
37-15/16”
(963mm)
18-9/16”
(470mm)
12-13/16”
(352mm)
6”
(152mm)
CL
CL
CL CL
17”
(432mm)
TOP VIEW
SIDE VIEW END VIEW
* Shown with optional glass surround.
6Regency Plateau™ PTO30 Outdoor Gas Fireplace
DIMENSIONS
PTO60 FINISHED TABLE TOP AND UNIT DIMENSIONS
71-13/16"
(1821mm)
68-3/16"
(1731mm)
68-5/16"
(1734mm) 15"
(381mm)
71-13/16"
(1821mm)
15"
(432mm)
12-13/16"
(325mm)
* Shown with optional glass surround.
NOTE: PTO60 is two PTO30 units assembled end to end.
Regency Plateau™ PTO30 Outdoor Gas Fireplace 7
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The PTO30 Outdoor Decorative Gas Appliance must
be installed in accordance with these instructions.
Carefully read all the instructions in this manual
rst. Consult the "authority having jurisdiction" to
determine the need for a permit prior to starting the
installation. It is the responsibility of the installer to
ensure this decorative gas appliance is installed in
compliance with manufacturers instructions and all
applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
GENERAL SAFETY
INFORMATION
1) The installation must conform with local
codes or, in the absence of local codes, with
CAN/CSA-B149.1, Natural Gas and Propane
Installation Code or CAN/CSA-B149.2, Propane
installation code the Natural Gas Fuel Code,
ANSI Z223.1/NFPA 54.
2) See general construction and assembly
instructions. The appliance should be enclosed.
3) Inspect the burner before each use of the
appliance for blockage and any signs of
deterioration
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPE-
CIALLY THE DECORATIVE GAS APPLI-
ANCE GLASS AND FACEPLATE, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
THIS APPLIANCE SHALL BE USED
ONLY OUTDOORS IN A WELL-VENTI-
LATED SPACE AND SHALL NOT BE
USED IN A BUILDING, GARAGE OR ANY
OTHER ENCLOSED AREA.
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
ANY GUARD OR OTHER PROTECTIVE
DEVICE REMOVED FOR SERVICING
THE APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS FIRE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
DO NOT SIT OR STAND ON DECORATIVE
GAS APPLIANCE.
SOLID FUELS SHALL NOT BE BURNED
IN THIS APPLIANCE.
DO NOT USE THIS APPLIANCE IF
ANY PART HAS BEEN UNDER WATER.
IMMEDIATELY CALL A QUALIFIED
SERVICE TECHNICIAN TO INSPECT
THE APPLIANCE AND TO REPLACE
ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLI-
ANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A DECORATIVE GAS APPLIANCE
OR STOVE, INSTALL AN ADJUSTABLE
SAFETY GATE TO KEEP TODDLERS,
YOUNG CHILDREN AND OTHER AT RISK
INDIVIDUALS OUT OF THE ROOM AND
AWAY FROM HOT SURFACES.
4) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
decorative gas appliance.
5) Wear gloves and safety glasses for protection
while doing required maintenance.
6) Maximum gas inlet pressure = 1/2 psig.
7) Under no circumstances should this appliance
be modifi ed. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
8) Installation and any repairs to this appliance
should be done by a qualifi ed service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
9) Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be burned
in this appliance.
10) The appliance and its individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 1/2
psi (3.5kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
11) The appliance area must be kept clear and
free of combustible materials, (gases and other
ammable vapours and liquids).
It is highly recommended to protect the
interior from moisture (rain, snow). Cover
the enclosure opening when not in use. This
decorative gas appliance is only for use
with the type of gas indicated on the rating
plate. This decorative gas appliance is not
convertible for use with other gases, unless a
certi ed kit is used.
12) Stainless Steel/ Sunset Bronze Weather
Cover must be removed when burner is in
operation.
13) When not using appliance for extended periods
of time - turn off gas supply and install Stainless
Steel Weather Cover.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
8Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
LOCATING YOUR
OUTDOOR DECORATIVE GAS APPLIANCE
1) When selecting a location for your decorative gas appliance, ensure that the clearances are met.
2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural
convection.
3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant
heat and could become damaged.
4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall
comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no
overhead cover.
Within a partial enclosure that includes an overhead cover and no more that two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
At least 25% of the total wall area is completely open, and
At least 30% of the remaining wall area is open and unrestricted
INSTALLATION
CHECKLIST
1) Locate appliance:
a) Refer to "Locating Your Outdoor decorative
gas appliance" section
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
2) Drain Installation (recommended).
3) Install ON/OFF switch - ensure it is in the OFF
position.
4) Make gas connections - test for leaks.
5) Install 4 "AA" batteries into each battery pack.
This unit will not operate without AA batteries
in place.
6) Install standard and optional features. Refer to
the following sections:
a. Tabletop Installation
b. Glass Crystals
c. Volcanic Stone Installation (optional)
d. Log Installation (optional)
e. Glass Surround Installation (optional)
f. Weather Cover Installation
7) Final check.
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label), after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
30% or more in total of the remaining wall
area is open and unrestricted.
Open side at least 25% of total wall area
Regency Plateau™ PTO30 Outdoor Gas Fireplace 9
INSTALLATION
Caution Requirements
The top, back and sides of the decorative gas appliance
are defi ned by standoffs. The metal ends of the
standoff may NOT be recessed into combustible
construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas
appliance be installed only in accordance with these instructions.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
PTO30 Clearance Requirements
Clearance: Dimension Measured From:
A: Back wall 17" (432mm) Burner to back wall
B: Sidewall 17" (432mm) Burner to sidewall
C: Ceiling 45" (1143mm) Burner to Ceiling
D: Unit Base 1"(25mm) Unit Base to Combustible
E: Alcove Width PTO30 84"(2134mm) Wall to Wall (Minimum)
E: Alcove Width PTO60 100" (2540mm) Wall to Wall (Minimum)
F: Alcove Depth 60" (1524mm) Front to Back Wall (Maximum)
Notes: 0" No Hearth Required
E
F
Alcove
A
C
B
D
10 Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
INNER FRAMING DIMENSIONS (REQUIRED)
NOTE:FRAMING MATERIAL NOT SUPPLIED
1”(25mm)
10-1/2”(267mm)
38-1/2”(978mm)
15”(381mm)
38-1/2”(978mm)
15”(381mm)
10-1/2”(267mm)
TOP VIEW
SIDE VIEW END VIEW
NOTE: Framing materials may be combustible or non-
combustible.
Finishing materials MUST be non-combustible.
Consideration should be given to weather / elements
when choosing framing materials (ie. treated lumber,
steel stud).
68-1/2"
(1740mm)
68-1/2"
(1740mm)
10-1/2""
(267mm)
15"
(381mm)
15"
(381mm)
TOP VIEW
SIDE VIEW END VIEW
PTO30
PTO60
Regency Plateau™ PTO30 Outdoor Gas Fireplace 11
INSTALLATION
FINISHING MATERIALS EXCEEDING 1"
Side nailing brackets are adjustable for material from a minimum of 1/2"
thick up to a maximum of 1" thick.
Determine total thickness of top facing and adjust nailing brackets.
Top facing material is to be brought to unit edge for fi nished look.
If using a material thicker than 1" on the top facing - the table top opening
must be maintained at 17-1/4" x 41-3/4" to allow for the proper fi t.
Nailing brackets
Nailing bracket
Top = 1/2" thick material
Middle = 3/4" thick material
Bottom = 1" thick material
17-1/4”
41-3/4”
Table Top
Burner Opening
Cutaway
Cutaway
12 Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa). Disconnect
piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should be
checked using the valve pressure ports
on the valve.
1) Make sure the valve is in the "OFF" position.
2) Loosen the "IN" and/or "OUT" pressure tap(s),
turning counterclockwise with a
1/8" wide at screwdriver.
3) Attach manometer to "IN" and/or "OUT" pressure
tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON" position.
5) The pressure check should be carried out with
the unit burning and the setting should be within
the limits speci ed on the safety label.
6) When nished reading manometer, turn off the
gas valve, disconnect the hose and tighten the
screw (clockwise) with a 1/8" at screwdriver.
Note: Screw should be snug, but do not over
tighten.
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue ame or
close for a more yellow ame.
Minimum Air Shutter Opening:
Fully Closed NG
1/2" LP
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
HIGH ELEVATION
This unit is approved for altitude 0 to 4500 ft. (CAN/
CGA 2.17-M91).
GAS LINE
INSTALLATION
Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA B149 installation
code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or ex connectors use only
approved ttings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and ex connectors are
usually considered to meet this requirement.
NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.
IMPORTANT: Always check for gas leaks with
a soap and water solution or gas leak detector.
Do not use open ame for leak testing.
PTO30-NG SYSTEM DATA
Max. Supply Pressure 14" WC (3.49 kpa)
Min. Supply Pressure 5" WC (1.25 kpa)
Manifold Pressure 3.5" WC (0.87 kpa)
Manifold Pressure -Low 1.6" WC (0.40 kpa)
Ori ce Size #25 DMS
Minimum Input 30,000 Btu/h
(8.79 kW)
Maximum Input 50,000 Btu/h
(14.65 kW) 3
PTO30-LP SYSTEM DATA
Max. Supply Pressure 14" WC (3.49 kpa)
Min. Supply Pressure 11" WC (2.73 kpa)
Manifold Pressure 10" WC (2.49 kpa)
Manifold Pressure-Low 6.4" WC (1.59 kpa)
Ori ce Size #45 DMS
Minimum Input 38,000 Btu/h
(11.13 kW)
Maximum Input 49,000 Btu/h
(14.36 kW)
Note: If you have an incorrect ame pattern,
contact your Regency® dealer for further
instructions.
Incorrect ame pattern will have small, probably
yellow ames, not coming into proper contact
with the rear burner or ame sensor.
Burner
Flame Sensor
Pilot Ignitor
PILOT ADJUSTMENT
Periodically check the pilot ames. Correct ame
pattern has two strong blue ames: 1 owing
around the ame sensor and 1 owing across
the burner (it does not have to be touching the
burner).
886 S.I.T. VALVE
DESCRIPTION
1) Manual high/low adjustment
2) Pilot adjustment
3) Outlet Pressure Tap
4) Inlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet
1
3
2
4
5
6
7
NOTE:
The PTO60 has a combined min. input of 60,000
Btu - NG/ 76,000 Btu - LP and max. input of
100,000 Btu - NG / 98,000 Btu - LP.
Care should be taken when sizing the gas pipe
due to the extremely high Btu of this unit.
Regency Plateau™ PTO30 Outdoor Gas Fireplace 13
INSTALLATION
PTO30 WALL SWITCH INSTALLATION
(INCLUDED WITH UNIT)
The unit comes with low voltage wire and a battery extension wire installed.
1) Run supplied wire to desired location - to a max. of 9 feet.
2) Install supplied electrical box in desired location.
3) Remove center knock out from electrical box and install strain relief
(strain relief nut not required).
4) Route low voltage wire and battery extension wire through the strain
relief.
5) Connect low voltage wire to supplied switch, fasten switch to right side of
electrical box (polarity not important).
8) Place supplied gasket on top of electrical box.
9) Fasten cover to electrical box using supplied screws.
10) Place switch in OFF position until fi nal installation is complete.
Center knock out
Strain Relief
6) Install supplied 4-AA batteries into the battery holder. Using velcro install
battery holder to the backside of the battery compartment door. Connect
battery terminal.
7) Using silicone, completely seal strain relief to protect from water or moisture.
14 Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
PTO60 WALL SWITCH INSTALLATION
(INCLUDED WITH UNIT)
Note: The PTO60 comes with 2-wall switches. Only one wall switch is re-
quired. The 2nd switch can either be discarded or saved as a spare part.
The unit comes with low voltage wire and a battery extension wire installed
on each burner.
1) Run supplied wire to desired location - to a max. of 9 feet for both
burners.
2) Install supplied electrical box in desired location.
3) Remove center knock out from electrical box and install strain relief
(strain relief nut not required).
4) Connect both sets of low voltage wires together from each burner - white
with white and black with black.
5) Route low voltage wires and battery extension wire through the strain
relief.
Note: Ensure the battery extension wires are approx. 8" in length inside the
electrical box.
This excess will ensure ease of battery replacement and servicing in
the future.
8) Using silicone, completely seal strain relief to protect from water or moisture.
9) Place supplied gasket on top of electrical box.
10) Fasten cover to electrical box using supplied screws.
11) Place switch in OFF position until fi nal installation is complete.
Center knock out Slide 1st battery
pack to the right.
Strain Relief
6) Attach low voltage wires to the switch - ensure to attach on the right side
of the switch. This will make it easier to remove the 2nd battery terminal
when replacing batteries. Fasten switch to right side of electrical box as
shown below.
7) Install 4- AA batteries into each battery terminal. Ensure correct polarity.
Slide the fi rst battery terminal all the way to the right - until it is next to the
switch.
The 2nd battery terminal can be attached to the battery cover with the
supplied velcro.
Regency Plateau™ PTO30 Outdoor Gas Fireplace 15
INSTALLATION
PTO30 DRAIN INSTALLATION (RECOMMENDED)
Although this decorative gas appliance is designed to operate outdoors safely, rain and other sources of moisture may enter the burner area, which will
cause water to collect inside the base of the unit.
To prevent excessive water collection, the installer should provide a way to drain the water from the base of the unit by building or installing a
water collector before positioning the decorative gas appliance in its location.
INSTALLATION INSTRUCTIONS
1) Remove 2 screws to remove the bracket from the bottom of the burner - this will allow access to the drain hole at the base of the unit.
2) On the exposed drain hole (see location below), install a PVC 3/4" threaded coupling reducer going from the top of the pan, down through the hole.
Apply a silicone-based sealant around the base and threads before installation. Cut notches into the top of the coupling reducer to prevent water
pooling.
3) Holding the reducer coupling with a wrench, thread a 90° PVC elbow (from the underside of the unit) to the reducer until it is tight to the metal.
4) Reinstall bracket from Step 1.
Note: To assure proper drainage, that decorative gas appliance must be installed on a leveled surface
5) Add additional piping to route the drain to an appropriate location.
NOTE: Install a drain on both burners on the PTO60.
Threaded
Reducer
(PVC)
Threaded
Elbow
@ 90°
(PVC)
Reducer and elbow can be purchased from your local
hardware store.
Cut notches into the top
of the coupling reducer to
prevent water pooling.
View from under-
side of burner.
16 Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
PTO30 WIRING DIAGRAM
This appliance does not require a 120V A.C. supply for operation.
NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Do not use a 9 volt battery.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical
Code, ANSI/NFPA 70, if applicable.
0.886.001
Proflame Valve
Standard Main On/Off Switch
or Optional Wall Switch
ON/OFF Switch
PTO60 WIRING DIAGRAM
Regency Plateau™ PTO30 Outdoor Gas Fireplace 17
INSTALLATION
PTO60 ASSEMBLY
1 Remove the large stand off from both PTO30 units - by removing 2
screws per side.
2) Remove the burner from one of the units - by removing 4 screws in loca-
tions shown below.
3) Bend fl ange 90º downward until it is fl at.
Do this on each burner only on end shown below.
Note: Removing a burner from one of the units will make it easier to stack
the burners.
This step is recommended - but not required.
4) Reinstall burner.
5) Line the two units up end to end. Stack the fl attened burner fl anges
(from previous step) one over top of the other. Create a fl at surface
across both burners.
6) Install units together into framing. Secure in place with nailing strips.
Bend ange till at
Large standoff
Bend ange till at
18 Regency Plateau™ PTO30 Outdoor Gas Fireplace
End Caps
INSTALLATION
Before installation,stainless steel must be handled and cleaned as per instructions noted below:
Stainless Steel Table Top
• Stainless table top must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
To protect the nish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when
removing protective coating).
•Stainless table top will discolor a little during normal operation.
This is normal and should not be considered a defect.
* All hand and nger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a lm/
residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this lm before applying heat to the unit.
Failure to do this will result in burn stains on table top which you will be unable to remove.
Not protected by product warranty.
PTO30 TABLE TOP INSTALLATION
NOTE: These instructions apply to both the stainless steel and sunset
bronze table tops.
Note: Instructions below shown with the Plateau Series coffee table base.
1) Place table top over completed unit.
2) Place end caps over pilot and opposite end to complete installation.
3) To remove - reverse steps.
Final Install
Regency Plateau™ PTO30 Outdoor Gas Fireplace 19
INSTALLATION
End Cap
Before installation,stainless steel must be handled and cleaned as per instructions noted below:
Stainless Steel Table Top
• Stainless table top must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
To protect the nish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when
removing protective coating).
•Stainless table top will discolor a little during normal operation.
This is normal and should not be considered a defect.
* All hand and nger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a lm/
residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this lm before applying heat to the unit.
Failure to do this will result in burn stains on table top which you will be unable to remove.
Not protected by product warranty.
PTO60 TABLE TOP INSTALLATION
1) Remove knockouts from both ends of unit with pliers as shown below.
3) Place end caps over both pilots at either end to complete installation.
Note: 2 caps remain - these may be discarded or kept as spare parts.
4) To remove - reverse steps 3-2.
Final Install
2) Place table top over completed unit.
Note: Unit shown below is not completed
20 Regency Plateau™ PTO30 Outdoor Gas Fireplace
INSTALLATION
Glass Crystals shown on Burner
For Units HZ54E, HZ54EPV, HZ42ST, HZ42STE, HZ42STEPV,
HZI234E, HZ42E, HZ42, HZ30E only
Glass Crystals (7 lbs) shown on Burner and Firebox Floor
For Units HZI390E, HZI390EB only
Optional Ceramic Spa Stones + Glass Crystals shown on burner.
For Units HZ54E, HZ54EPV, HZ42ST, HZ42STE, HZ42STEPV,
HZI234E, HZ42, HZ42E, HZ30E only
Glass Crystals shown on Burner
For units P33S, P33SE, L676S, U32S, U32SE, E33S only
BURNER PACKAGES
Unit *Glass Crystals Ceramic Spa Stones
HZ54E / HZ54EPV 3 lbs 1 lb Glass + 2 packages (140 spa stones)
HZ42 / HZ42E 2 lbs 1 lb Glass + 1 package (70 spa stones)
HZ42ST / HZ42STE
HZ42STEPV
2 lbs 1 lb Glass + 1 package (70 spa stones)
HZ30E ** 1 lb 1 lb Glass + 1 package (70 spa stones)**
HZI234E *** 3/4 lb 3/4 lb Glass + 1 package 70 spa stones)***
HZI390E/ HZI390EB * 7 lbs [4lbs burner+3lbs fi rebox] 2 lb Glass + 1 package (70 spa stones)
HZO42/HZO42 (AUS) 3 lbs Not Approved
L676S 1 lb 1 package = (70 spa stones)
P33S/P33SE **** 1 lbs 1 package = (70 spa stones)****
PTO30 */ Plateau Series 10 lbs Not Approved
PTO60 20 lbs Not Approved
U32S / U32SE 1 lb 1 package = (70 spa stones)
E33S 1 lb 1 package = (70 spa stones)
NOTE: * Glass Crystals are available in 1lb and 5lb bags. All units come standard with Cobalt Blue glass crystals except:
* HZO42 comes with Copper glass crystals.
* HZI390E, HZI390EB, PTO30, PTO60 & Plateau Series do NOT include glass crystals with units. Must purchase separately.
• 1 Ceramic Spa stone package contains 70 stones.
• 1 Ceramic Garden stone package contains 50 stones.
** Recommended - use only 40 of the 70 ceramic stones on the HZ30E burner.
*** Recommended - use only 24 of the 70 ceramic stones on the HZI234E burner.
**** Recommended - use only 50 of the 70 ceramic stones on the P33S/P33SE burner.
Optional Ceramic Spa Stones shown on burner.
For units P33S,P33SE L676S, U32S, U32SE, E33S only
Evenly spread the Glass Crystals or optional Ceramic Spa Stones over the burner. Ensure the crystals (or stones) do not overlap too much as
this will effect the fl ame pattern.
IMPORTANT NOTE:
Only the supplied approved Glass Crystals and Ceramic Spa Stones are to be used with these fi replaces. Use of any other type of glass crystals
or stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
When using Ceramic Spa Stones DO NOT cover burner ports or pilot light that lead to pilot fl ame. Ensure the crystals or stones do not overlap
excessively as this will effect the fl ame pattern.
Glass Crystals shown on Burner
For Units HZO42, HZO42 (AUS) PTO30, PTO60 Plateau Series only
GLASS CRYSTAL INSTALLATION ON BURNER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Regency Plateau PTO60-LP Guide d'installation

Catégorie
Cheminées
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues