AND UT-302 Manuel utilisateur

Catégorie
Thermomètres corporels numériques
Taper
Manuel utilisateur
PREMIUM
EAR THERMOMETER
UT-302
Instruction Manual
ORIGINAL
Greetings
Congratulations on your purchase of the A&D Medical UT-302
Instant-Read Ear Thermometer. This easy to use thermometer offers
a safe, accurate and quick way to take a temperature measurement
through the ear. It is an especially convenient method of taking a child’s
temperature and perfect for adults too.
Before Use
In order to obtain an accurate measurement, please read this
instruction manual carefully before using.
Precautions
This thermometer is designed to take a temperature through the ear
canal. DO NOT use it to take rectal, oral or underarm temperature.
This ear thermometer is a delicate electronic device. Please handle
with care.
Only the tip of the ear thermometer is waterproof. Follow the proper
cleaning instructions as outlined in this manual. Do not submerge
body of thermometer in water or any other liquid.
Do not expose thermometer to direct sunlight.
Precision components were used in the construction of this device.
Extremes in temperature, humidity, shock or dust should be avoided.
Keep this device out of the reach of children.
Do not self-diagnose your condition using the measured result.
Consult your doctor if your temperature is higher than the normal
temperature.
Do not use the ear thermometer if there is blood or drainage in the
external ear canal.
Do not use the ear thermometer in an infected ear.
Do not force the thermometer tip into the ear canal.
Do not disassemble the ear thermometer.
Contents
Parts Identication E-3
Symbols E-4
Taking Your Temperature E-5
Switching The Unit Of Measure E-10
Replacing the Battery E-11
Care and Cleaning E-12
Troubleshooting E-13
Technical Data E-14
Warranty E-15
E-3
Parts Identication
Probe
Use this part to
insert into your ear
Power & Scan
button
Press this button to
power on and scan
the ear temperature
LCD Display
Display the
measurement
results Battery Cover
Fronthead Cover
Memory button
Press this button to
track historical data
M
E-4
Symbols
Degrees of temperature
Scanning sequence in progress
Smiling face (indicates temperature is lower than
38°C or 100.4°F)
Sad face (indicates temperature is higher than
38°C or 100.4°F)
Celsius Scale
Fahrenheit Scale
Low battery warning
Memory symbol
E-5
Taking your Temperature
Before You Start
This product is intended for household use only. lf you have questions
about the meaning of a specic temperature, please consult your
physician.
Use the thermometer at room temperature between 60.8ºF - 104.0ºF
(16ºC - 40ºC). lf the ear thermometer is stored in an environment where
the temperature is out of that range, move the thermometer to a location
with a room temperature of 60.8ºF - 104.0ºF (16ºC - 40ºC). Allow the
thermometer to equalize to that temperature range before use.
DO NOT measure temperature if:
Your ear is cold, wet or blocked with ear wax
lt is within 30 minutes after eating, taking a bath or physical exercise
You are suffering from an ear infection
NOTE: Make sure the tip of the thermometer is clean. A dirty lens may cause an inaccurate
measurement. Clean the lens with a soft, alcohol moistened cloth or cotton swab. Never use an
abrasive cleaner. Never submerge the body of the thermometer in water or any other liquid.
We recommend you practice with the A&D Medical ear thermometer
on yourself and family members while you are healthy. This way you
know how the thermometer works and will feel more condent of the
measurements when you or a family member is ill.
E-6
Taking your temperature
How The Ear Thermometer Works
The A&D Medical ear thermometer utilizes infrared thermo scanning
principies to scan the temperature of the human eardrum. The eardrum
is located beneath the surface and not easily inuenced by the changing
temperature in the environment.
The A&D Medical ear thermometer is faster, safer and easier to use
than traditional stick thermometers. lt scans the eardrum 512 times per
second and displays the highest temperature detected. Measurements
can even be taken while your child is sleeping. For adults, an ear
thermometer offers fast, comfortable, accurate readings in seconds.
Why The Ear?
Research indicates that the ear is an ideal site for taking body
temperature. The eardrum shares blood vessels with the hypochalamus,
the part of the brain that controls body temperature. Therefore, the ear is
an accurate indicator of internal body temperature.
E-7
Taking Your Temperature
1. Press Fronthead cover's sides to
remove.
2. Press the Power/Scan button for one
second consecutively. The system will
perform a self-test, and all symbols
will be displayed on the LCD for one
second
3. After the self-test, the last temperature
taken will be shown on the display.The
UT-302 is now ready to take a new
measurement
4. Press the Power/Scan " " again. The
symbol " " will appear beneath the
last reading.
E-8
Taking Your Temperature
5. lnsert the probe into the ear canal. The
probe must be inserted well into ear
to allow the probe tip to continuously
sean the ear canal. This will ensure an
accurate temperature measurement.
6. After one second a beep will sound
indicating the reading is complete.
Remove the thermometer from the ear
to get the temperature reading.
7. A smiling face" " will appear
indicating a temperature reading lower
than 38ºC (100.4ºF).
A sad face " " accompanied by one
long and two short beeps will indicate
a temperature of 38ºC (100.4ºF) or
higher.
E-9
8. A "Lo" or a "Hi" symbol appears when
the temperature measured is out of the
measurement range.
Taking Your Temperature
9. The symbol "Err" appears if the
operating temperature is not within
16ºC (60.8ºF) and 35ºC (95ºF).
10. To recall past readings, press the
"M" button on the underside of the
unit. The memory symbol and the set
index appear at the top left side of the
display.
11. To insure a long battery life, this
thermometer will automatically power
off after one minute of non-use.
E-10
Switching The Unit Of Measure
1. To switch between ºC or ºF, press the
Power/Scan " " button once. Then
press and hold the Power/Scan " "
button. Now, press the "M" button to
toggle between the ºC or ºF modes.
E-11
Replacing the Battery
Low Battery Warning
Replace the battery when the low battery warning symbol " " appears
on the display. When the low battery symbol appears, the thermometer
is still fully functional. When the "Lo" and " " appear on the display you
should stop using the thermometer until the battery has been replaced.
Battery Installation
1. Using a small phillips head screwdriver, remove the screw from the
battery lid and remove the lid.
2. Using a non-metal pointed tool, carefully dislodge the battery and
remove.
3. lnsert a new 3 Volt CR-2032 Lithium battery, with the positive (+) side
facing up.
4. Place the lid back on and screw in to secure.
Note:Battery removal clears readings stored in memory.
E-12
Care and Cleaning
Probe Lens
Clean the lens of the thermometer with a
soft, alcohol moistened cotton swab after
each use. Do not use water to wash the
probe lens.
Thermometer
Clean the body of the thermometer with a soft, dry cloth - DO NOT use
water, cleaning solutions or any other liquid. Never use an abrasive cleaner
or submerge the body of the thermometer in water or any other liquids.
E-13
Troubleshooting
Problem Recommended Action
Why do I get consistently low
temperature readings?
The thermometer is not positioned
properly in the ear. The tip of the
thermometer must form a seal around
the opening of the ear.
The waterproof lens is dirty. Clean the
lens with a soft, alcohol moistened
cotton swab.
Why is the reading taken in
the right ear different from
that taken in the left ear?
The temperature is roughly the same
in both ears, but the values may differ
because the shape and cleanliness of
each ear is different. Also, the position
of the thermometer can affect the
reading.
Can I use this thermometer
to measure an animal's
temperature?
No. This thermometer has been
designed exclusively for human
use. The UT-302 ear thermometer
was programmed specically for the
human ear construction and human
body temperature.
E-14
Technical Data
Model UT-302
Dimensions 2.2" x 1.75" x 6.2"
55.3 X 44.4 X 158.5mm
Weight 2.3 oz. (65.5 g)
Sensor type Thermopile Sensor STI 18
Measuring accuracy ±0.4ºF (0.2ºC): From 96.8ºF to102.2ºF
(36ºC - 39ºC)
±0.5°F (0.3ºC): Less than 96.8ºF (36ºC)
or greater than 102.2ºF (39ºC)
Measuring range 50ºF - 122ºF (10ºC - 50ºC)
Display resolution 0.1 ºF or ºC
Response time 1.0 Second
Memory function 10 memory recall
Thermometer tip Equipped with a waterproof lens. No lens
cover is required.
Automatic shut down The thermometer will automatically turn
off after one minute of non-use
Power supply One 3 Volt CR-2032 Lithium battery
Battery life Approximately 5,000 measurements
Operating environment 60.8ºF - 95ºF (16ºC - 35ºC) with
relative humidity up to 95%
Storage environment -4ºF - 122ºF (-20ºC - 50ºC) with relative
humidity up to 95%
E-15
LIMITED WARRANTY
A&D Medical
For purchasers within the US and Canada only:
Product Consumer Warranty Term
UT-302 2 Years
For outside of US and Canada, please contact local distributor or dealer.
Limited Warranty:
A&D Medical (“A&D”) warrants to the rst purchaser (“You”) that the
A&D product You purchased (the “Product”) will be free from defects
in material, workmanship and design for the applicable Warranty Term
stated above from the date You purchased the Product under normal
use. This Limited Warranty is personal to You and is not transferable.
If the Product is defective, then You return the Product to A&D in
accordance with the procedure set forth below. A&D’s warranty
obligation is limited to the repair or replacement, at A&D’s option, of the
defective Product that has been returned by You within the warranty
period. Such repair or replacement will be at no charge to You. The
repaired or replacement Product is warranted here-under for the longer
of the remainder of the original warranty period or 90 days from the
date of shipment of the repaired or replacement Product. If you return
the Product for warranty service to A&D, You must return the Product,
freight and insurance prepaid, within the warranty period to the address
set forth below, together with satisfactory proof of the date of Your
purchase and a description of the defect.
Returns will not be accepted unless a Return Material Authorization (RMA)
Number has been issued from A&D Customer Service Representative.
In US
A&D Medical
Attn.: Warranty Department
4622 Runway Boulevard
Ann Arbor, MI 48108 USA
1-800-726-3364
In Canada
Auto Control Medical
Attn.: Warranty Department
6695 Millcreek Dr., Unit 6
Mississauga, ON, L5N 5R, Canada
1-800-461-0991
Warranty
E-16
Warranty
This Limited Warranty does not cover, and A&D will not be liable for (i) any
shipment damage, (ii) any damage or defect due to misuse, abuse, failure
to use reasonable care, failure to follow written instructions enclosed
with the Product, accident, subjecting the Product to any voltage other
than the specied voltage, improper environmental conditions, or
modication, alteration or repair by anyone other than A&D or persons
authorized by A&D, or (iii) expendable or consumable components.
THIS LIMITED WARRANTY IS THE ONLY WARRANTY PROVIDED
A&D; THERE ARE NO OTHER EXPRESS WARRANTIES. If A&D
cannot reasonably repair or replace the Product, A&D will refund the
amount You paid for the Product (not including taxes), less a reasonable
charge for usage. To receive a refund you must have returned the
Product and all associated materials to A&D. The above remedy of
repair, replacement or refund is your only and exclusive remedy. IN NO
EVENT SHALL A&D BE LIABLE FOR ANY DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS, LOST INFORMATION
OR REPLACEMENT COSTS, ARISING OUT OF YOUR USE OF
OR INABILITY TO USE THE PRODUCT, INCLUDING, WITHOUT
LIMITATION, ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES, EVEN IF A&D HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES. Some states do not allow the exclusion of
incidental or consequential damages, so that the above exclusions may
not apply to you. This warranty gives you specic legal rights, and you
may also have other rights that may vary from state to state.
No distributor, dealer or other party is authorized to make any warranty
on behalf of A&D or to modify this warranty, or to assume for A&D any
liability with respect to its products.
PREMIUM
THERMOMÈTRE AURICULAIRE
UT-302
Manuel d’utilisation
ORIGINAL
Salutations
Félicitations pour votre achat du thermomètre auriculaire
à lecture instantanée A&D Medical UT-302. Ce thermomètre est facile à
utiliser et vous permet de prendre la température dans l’oreille de manière
sécuritaire, précise et rapide. Cette méthode est très pratique pour prendre
la température d’un enfant et est également parfaite pour les adultes.
Avant utilisation
An d’obtenir une mesure précise, veuillez lire attentivement ce mode
d’emploi avant de l’utiliser.
Précautions
Ce thermomètre est conçu pour prendre la température par le conduit
auditif. NE l’utilisez PAS pour prendre la température du rectum, de la
bouche ou des aisselles.
Ce thermomètre auriculaire est un appareil électronique délicat.
Veuillez donc le manipuler avec précaution.
Seul l’embout du thermomètre auriculaire est étanche. Suivez les
instructions de nettoyage appropriées décrites dans ce mode d’emploi.
Ne plongez pas le corps du thermomètre dans l’eau ou tout autre liquide.
N’exposez pas le thermomètre à la lumière directe du soleil.
Des composants de précision ont été utilisés dans la construction
de cet appareil. Il convient d’éviter les extrêmes en matière de
température, d’humidité, de chocs ou de poussière.
Gardez cet appareil hors de la portée des enfants.
Ne faites pas de diagnostic de votre état à partir des températures
obtenues. Consultez votre médecin si votre température est
supérieure à la normale.
N’utilisez pas le thermomètre auriculaire en cas de présence du sang
ou d’un écoulement dans le conduit auditif externe.
N’utilisez pas le thermomètre auriculaire dans une oreille infectée.
Ne forcez pas l’embout du thermomètre dans le conduit auditif.
Ne démontez pas le thermomètre auriculaire
Table des matières
Identication des pièces F-3
Symboles F-4
Prise de température F-5
Changement d’unité de mesure F-10
Remplacement des piles F-11
Entretien et nettoyage F-12
Dépannage F-13
Fiches techniques F-14
Garantie F-15
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

AND UT-302 Manuel utilisateur

Catégorie
Thermomètres corporels numériques
Taper
Manuel utilisateur

dans d''autres langues