Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
Contents
Introduction ....................................................................................................................................................................... 2
Installation Procedures ..................................................................................................................................................... 2
Configuration Procedures ................................................................................................................................................. 5
FCC / Industry Canada Compliance ................................................................................................................................. 7
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
Introduction
This user manual describes the features, specifications, and operation of the Censys UHF Reader from Brady
Corporation.
The Censys reader is a small, low cost, easy to install UHF RFID reader with wireless data transport to a an
application server. Its purpose is to provide a function similar to real time location system (RTLS) at reduced
complexity and cost using only passive tags. Model BCENSYS-1000 takes power from a 5V 2A USB interface
which can be provided using common plugin wall adapters or outlets with a properly rated USB port. Model
BCENSYS12-1000 can alternatively be powered from a 12-24V central power supply for longer power runs. Each
reader unit periodically scans its local area which is constrained by its read range performance. The UHF reader
sub system is an EPC Gen 2 and ISO 18000-63 compliant reader. The embedded software application notifies
the server of all tag events that occurred during the last scan cycle using a wireless network. A tag event may be
for example when a tag first enters the reader’s range. The wireless network is built upon WiFi and will typically
bridge to a wired Ethernet system to provide connectivity to the server. The server may also be cloud hosted.
The server and reader may also have two way communications using the wireless (and wired) network. A high
level block diagram is shown below.
The RFID Reader Kit is delivered with the following components and accessories:
One RFID Reader with Integrated Circular Polarized Antenna
One AC/DC Power Supply
Mounting Hardware Kit
Read this manual first
Read and understand the contents of this manual before installing or operating this equipment. These
instructions cannot cover all details, variations of the equipment, or use cases.
Installation Procedures
Contained in the box will be the following: CenSys RFID Reader, 6’ 5V 2A Micro-USB Power Supply, 4ct Screw
Mounting Pack, Grommet.
Product Installation for 5V USB Version
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
1
Insert the Micro-USB plus into the
port on the reader board
2
Wrap the cord around the cord-
secure posts
3
Insert the grommet around the
cord, and slide into the grommet
channel
4
Position reader in mounting
location and drill through guide
holes*
* Note: Other mounting methods such as Velcro®
may be used in lieu of screw mounting.
5
Use drywall anchors to secure in the
wall
6
Secure the unit to the wall and
attach the front cover
Product Installation for 12V input version
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
1
Insert the 12V leads into the
terminal block the of the reader
board
2
Wrap the cord around the cord-
secure posts
3
Insert the grommet around the
cord, and slide into the grommet
channel
4
Position reader in mounting
location and drill through guide
holes*
* Note: Other mounting methods such as Velcro®
may be used in lieu of screw mounting.
5
Use drywall anchors to secure in the
wall
6
Secure the unit to the wall and
attach the front cover
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
Configuration Procedures
Before using the product determine the appropriate configurations based on your needs.
Connecting Reader
Connect the reader to a power source
Using a computer or mobile device, find the
“CenSys” SSID and connect to the wireless network.
Once connected, open a web browser
The following prompt should appear in your web
browser
Enter your wireless network name, select the
security, and enter the password
The “Broker URL” is set to the default broker, and
unless you are using your own software, this broker
URL does not need to be changed.
Enter your Site ID. Site ID will be provided within 48
hours of system purchase
Configuring reader
Place the reader in the intended final mounting position.
Remove any large objects, metal, or human obstructions
from a 10’ radius of the reader unit.
Plug in or connect power to the reader unit.
Stand back at least 8 feet from the reader (the reader
will be detecting the natural state of environment)
The LED light on the reader will flash red 10 times, hold
steady red, and then turn blue confirming it’s connected
to your WiFi.
Log into the CenSys software at [insert URL here]. Your
login will be provided to you via e-mail.
Once logged in, on the left, click on Manage, and select
“Assets”
You will see a site named “Home” and on the right you
will see four tabs; Assets, Readers, Un-Assigned Readers,
and Settings.
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
Make sure that the wireless network is range (note:
reader does not need to be in final installation
position, although it could be)
Click “Submit.” The reader will power-cycle, and
you will see it go through it’s start up sequence
LED will flash red 10 times, go solid red, and then
turn blue once successfully connected to the
network. If successful, reader may be unplugged
and installed in final location without further
configuration.
If LED turns or stays red, it was unable to connect to
your WiFi. Cycle power and repeat this step until
connected.
Select the “Un-Assigned Readers” tab.
Your reader should be visible here if properly connected.
From here you can click on “Edit” and assign the reader
to a location within your site hierarchy.
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
FCC / Industry Canada Compliance
CONTAINS FCC ID: 2ADHKATWINC1500
CONTAINS IC: 20266-ATWINC1500PB
FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Warning
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Innovation, Science and economic Development Canada (ISED):
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following
two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Cet appareil est conforme à la norme d'Industrie Canada, exempts de licence standard RSS (s). Son fonctionnement
est soumis aux deux conditions suivantes: 1) le dispositif ne doit pas causer d'interférences, et 2) le dispositif doit
accepter toute interférence, y compris les interférences qui susceptible de provoquer un mauvais fonctionnement de
l'appareil.
RF Exposure:
To comply with FCC and IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used
for this transmitter must be installed to provide a separation distance of at least 32 cm from all persons and operating
in conjunction with any other antenna or transmitter.
Pour se conformer aux limites d'exposition RF FCC et IC pour la population générale / l'exposition incontrôlée,
l'antenne utilisée pour cet émetteur doit être installée pour assurer une distance de séparation d'au moins 32 cm de
toutes les personnes et fonctionnant conjointement avec toute autre antenne ou émetteur .
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and max-
imum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
Censys: UHF Reader
Censys User Guide March 2017 Version 1.0
This device has been designed to operate with the antenna(s) listed below, and having a maximum gain
of 5.5 dB. Antennas not included in this list or having a gain greater than 5.5 dB are strictly prohibited for use
with this device. The required antenna impedance is 50 ohms.
En vertu de la réglementation d'Industrie Canada, cet émetteur radio ne peut fonctionner qu'avec une antenne
d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Pour réduire les
interférences radio potentielles avec d'autres utilisateurs, le type d'antenne et son gain devraient être choisis de
manière à ce que la puissance éloignée isotrope équivalente (e.i.r.p.) ne soit pas supérieure à celle nécessaire à
une communication réussie.
Cet appareil a été conçu pour fonctionner avec les antennes indiquées ci-dessous et ayant un gain maximal de
5,5 dB. Les antennes non comprises dans cette liste ou ayant un gain supérieur à 5,5 dB sont strictement
interdites pour être utilisées avec cet appareil. L'impédance d'antenne requise est de 50 ohms.
RFID Reader Circular Antenna
Brady Part Number: Y4509238
Polarization: RHCP
Impedance: 50 ohms
Gain: 5.5dBi max
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Brady NUC-BC1000 Manuel utilisateur

Catégorie
Des ponts
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues