1
5. Click or tap your Go Direct sensor
from the list of Discovered
Wireless Devices. Your sensor's ID
is located near the barcode on the
sensor. The Bluetooth LED will
blink green when it is successfully
connected.
6. Click or tap Done to enter data-
collection mode.
on LabQuest 2. You are now ready
to collect data.
Connecting the Sensor
See the following link for up-to-date connection information:
www.vernier.com/start/gdx-ccs
Connecting via Bluetooth
Ready to connect Red LED next to Bluetooth icon flashes when
the sensor is awake and ready to connect. At the
same time, the red LED next to the power icon is
steady.
Connected Green LED next to Bluetooth icon flashes when
the sensor is connected via Bluetooth. At the
same time, the red LED next to the power icon is
on steady.
Connecting via USB
Connected Red LED next to power icon on steady when
sensor is connected to Graphical Analysis via
USB. LED next to Bluetooth icon off.
Powering the Sensor
Turning on the sensor
Red LED is on steady when connected to AC
power.
Putting the sensor in sleep
mode
Red LED is off when disconnected from AC
power.
Using the Product
Connect the sensor following the steps in the Getting Started section of this user
manual.
Go Direct
®
Constant Current
System
(Order Code GDX-CCS)
The Go Direct Constant Current System is a DC power source with a built-in
current probe designed for use in electrochemistry experiments. The user can set
the current by tuning the dial. The system is capable of delivering up to 0.6 A.
The following is a partial list of activities and experiments that can be
performed using this sensor.
l Electroplating and Faraday’s law
l Electrolysis
l Determining Avogadro’s number
Note: Vernier products are designed for educational use. Our products are not
designed nor are they recommended for any industrial, medical, or commercial
process such as life support, patient diagnosis, control of a manufacturing
process, or industrial testing of any kind.
What's Included
l GoDirect Constant Current System
l ACpower adapter
l Micro USBCable
Compatible Software
See www.vernier.com/manuals/gdx-ccs for a list of software compatible with the
Go Direct Constant Current System.
Getting Started
Please see the following link for platform-specific connection information:
www.vernier.com/start/gdx-ccs
Bluetooth Connection USB Connection
1. Install Graphical Analysis 4 on
your computer, Chromebook™, or
mobile device. See
www.vernier.com/ga4 for software
availability.
2. Turn on your sensor by plugging
it into the AC power adapter. The
Bluetooth
®
LED will blink red.
3. Launch Graphical Analysis 4.
4. Click or tap Sensor Data
Collection.
1. Install Graphical Analysis 4 on your
computer or Chromebook. If using
LabQuest 2, make sure LabQuest
App is up to date. See
www.vernier.com/ga4 for software
availability or
www.vernier.com/downloads to
update LabQuest App.
2. Turn on your sensor by plugging it
into the AC power adapter.
3. Connect the sensor to the USB port.
4. Launch Graphical Analysis 4 or turn
2
support@vernier.com or call 888-837-6437. Support specialists will work with
you to determine if the unit needs to be sent in for repair. At that time, a Return
Merchandise Authorization (RMA) number will be issued and instructions will
be communicated on how to return the unit for repair.
Accessories/Replacements
Item Order Code
LabQuest Power Supply
LQ-PS
Micro USB Cable
CB-USB-MICRO
USB-C to Micro USBCable
CB-USB-C-MICRO
Warranty
Vernier warrants this product to be free from defects in materials and
workmanship for a period of five years from the date of shipment to the
customer. This warranty does not cover damage to the product caused by abuse
or improper use. This warranty covers educational institutions only.
Disposal
When disposing of this electronic product, do not treat it as household waste. Its
disposal is subject to regulations that vary by country and region. This item
should be given to an applicable collection point for the recycling of electrical
and electronic equipment. By ensuring that this product is disposed of correctly,
you help prevent potential negative consequences on human health or on the
environment. The recycling of materials will help to conserve natural resources.
For more detailed information about recycling this product, contact your local
city office or your disposal service.
Battery recycling information is available at www.call2recycle.org
Do not puncture or expose the battery to excessive heat or flame.
The symbol, shown here, indicates that this product must not be disposed of
in a standard waste container.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may cause undesired operation
RF Exposure Warning
Specifications
Range 0 to 0.6 A
Linearity 0.1%
Supply Voltage 5 VDC
Supply current (typical) 9 mA
Output voltage range 0 to 5 V
Transfer function Vout=6.9(I) + 0
Power supply (input) 100240 Volts AC
50/60 Hz 0.5 A
2641 VA
Power supply (output) 5 V, 1.5 A
USB specification 2.0
Wireless specification Bluetooth 4.2
Maximum wireless
range
30 m
Dimensions 9 cm length, 6 cm height, 5 cm depth, leads: 60 cm
long
How the Sensor Works
The Go Direct Constant Current System is a DC-coupled amplifier capable of
delivering up to 0.6 A at 5 V DC. A current-sensing resistor allows monitoring
of the output current by the data-collection software.
Current Conventions
The current will be indicated as positive if current flows from the positive (red)
terminal to the negative (black) terminal as described by conventional current
flow notation. Using electron flow notation, electrons flow out of the negative
terminal through the circuit back to the positive terminal. The negative terminal
is connected to ground via a power transistor and 0.1 Ω sensing resistor. The
positive terminal connects to a 5 V power supply. The Constant Current System
dial can be tuned to deliver up to 0.6 A with the voltage adjusting
automatically (max 5 V). If the electrolyte resistance is too high, the 0.6 A may
not be attained before the maximum of 5 V is reached.
Troubleshooting
For troubleshooting and FAQs, see www.vernier.com/til/3851
Repair Information
If you have followed the troubleshooting steps and are still having trouble with
your Go Direct Constant Current System, contact Vernier Technical Support at
3
The equipment complies with RF exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must
not be co-located or operating in conjunction with any other antenna or transmitter. You are cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void your authority to operate the equipment.
IC Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Industry Canada - Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus
as set out in the interference-causing equipment standard entitled Digital Apparatus,” ICES-003 of Industry Canada. Operation is subject
to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that permitted for successful communication.
RF exposure warning: The equipment complies with RF exposure limits set forth for an uncontrolled environment. The antenna(s) used
for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’appareil doit accepter tout interférence radioélectrique, même si cela résulte à un brouillage susceptible d’en compromettre le
fonctionnement.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans
la norme sur le matériel interférant-brouilleur: Appareils Numériques,” NMB-003 édictée par industrie Canada. L’utilisation est soumise
aux deux conditions suivantes:
(1) cet appareil ne peut causer d’interférences, et
(2) cet appareil doit accepter toutes interférences, y comprises celles susceptibles de provoquer un disfonctionnement du dispositif.
Afin de duire les interférences radio potentielles pour les autres utilisateurs, le type d’antenne et son gain doivent être choisie de telle
façon que léquivalent de puissance isotrope émis (e.i.r.p) n’est pas plus grand que celui permis pour une communication établie.
Avertissement d’exposition RF: L’équipement est conforme aux limites d’exposition aux RF établies pour un environnement non
supervisé. L’antenne (s) utilisée pour ce transmetteur ne doit pas être jumelés ou fonctionner en conjonction avec toute autre antenne ou
transmetteur.
Note: This product is a sensitive measurement device. For best results, use the cables that were provided. Keep the device away from
electromagnetic noise sources, such as microwaves, monitors, electric motors, and appliances.
Vernier Software & Technology
13979 SW Millikan Way Beaverton, OR 97005-2886
Toll Free (888) 837-6437 (503) 277-2299 Fax (503) 277-2440
info@vernier.com www.vernier.com
Rev. 04/02/18
Go Direct, Graphical Analysis, LabQuest, and other marks shown are our trademarks or registered trademarks in
the United States. All other marks not owned by us that appear herein are the property of their respective
owners, who may or may not be affiliated with, connected to, or sponsored by us.
The Bluetooth
®
word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of
such marks by Vernier Software & Technology is under license. Other trademarks and trade names are those of
their respective owners.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Vernier GDX-CCS Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues