EBP US Gang Button Panels • Setup Guide
The Extron EBP 50, EBP100 and EBP200 eBUS
®
Button Panels (EBPs) are fully customizable AV system control interfaces for
use with Extron IPCPPro Series Control Processors.
NOTE: These products are only for use with Extron UL Listed IPCP Pro control processors.
Each EBP has two eBUS ports that support both power and communications between the IPCPPro control processor and eBUS
devices. Up to eight eBUS endpoint devices such as EBP button panels can be connected to the control processor and to each
other in various cabling topologies. Cabling topology refers to the physical layout of cabling interconnections between devices
in a network such as an eBUS system. eBUS systems can include daisy chain, star, or a combination of both topologies (see
the eBUS Technology Reference Guide, available at www.extron.com, for basic diagrams). Every endpoint device must have a
unique identication address (bus ID) within the system.
Setup involves setting bus ID DIP switches on the EBPs, then using Extron GlobalCongurator
®
Plus and Professional (GCP)
software, the Toolbelt utility, or Global Scripter
®
programming, to congure the control processor. Once congured, the panels can
be used for AV system control.
This guide provides basic instructions for an experienced installer to install any of these panels. For more details on the EBPs, see
the eBUS Technology Reference Guide. For details on conguration, see the software help les.
Features
Rear Panel Features
NOTE: The EBP 100 and EBP 200 rear panel features are identical.
EBP 50 Rear Panel
BUS ID
M
S
B
L
S
B
12
ON
3456
PWR LOAD = X.XW
LINK
COM
ERROR
ID
ERROR
+V +S -S G+V +S -S G
STATUS
eBUS
EBP 100 Rear Panel
PWR LOAD = X.XW
+V +S -S G+V +S -S G
eBUS
BUS ID
M
S
B
L
S
B
12
ON
3456
AA
A
A
B
B
B
B
C
C
C
C
D
D
D
D
Figure 1. EBP Rear Panel Features
A
Status LEDs — Provide diagnostic information about the connection, communication, and power status of the panels.
The EBP 100 and EBP 200 have a single green LED.
The EBP 50 has yellow, red, and green LEDs.
For more information about how the LEDs are used for troubleshooting, see Step 7: Test and Troubleshoot on page 10.
B
eBUS Connectors (2 ports) — The four-pole captive screw connectors use the Extron eBUS protocol to connect the panel to
a controller and to other panels (see Step 5: Cable All Devices on page 8).
C
DIP Switches — Up to eight devices can be connected to one control processor. Each device connected to the same control
processor must have a unique BUS ID, which is set using DIP switches (see Step 4: Set Bus ID Addresses on page 5).
D
Mounting Holes — Used to mount the device to UL-listed junction boxes (see Step 8: Mount the EBPs on page 11).
EBP 50 (1 gang) 2 mounting holes
EBP 100 (2 gang) 4 mounting holes
EBP 200 (3 gang) 6 mounting holes
figure 1
2
EBP US Gang Button Panels • Setup Guide (Continued)
Front Panel Features
Extron
DISPLAY
ON
PC
VIDEO
OFF
LAPTOP
MUTE
VOLUME
E
xtron
ON
VID
E
OFF
L
AP
T
MUT
V
O
L
U
M
E
PC
MUTE
E
T
RESET
E
PC
DOC
CAM
VG A
ON
OFF
MUTE
LAPTOP
HDMI
SCREEN
UP
SCREEN
DOWN
RESET
Extron
DISPLAY
VOLUME
Ex
t
r
o
n
V
O
L
U
M
ON
OFF
PC
DOC
CAM
VG A
MUTE
LAPTOP
HDMI
SCREEN
UP
SCREEN
DOWN
CCCC
E
EEE
E
EEE
C
CCC
B
BBBAAAA
BBBBAAAA
EBP 100 Front Panel with Faceplate
EBP 100 Front Panel without Faceplate
FFFF
EBP 200 Front Panel with Faceplate EBP 200 Front Panel without Faceplate
FFFF
EBP 50 Front Panel with Faceplate
EBP 50 Front Panel without Faceplate
GGGG
GGGG
FFFF
C
CCC
E
R
E
S
E
T
E
RESET
ON OFF
VOL
PC
VOL
VIDEO
E
ON OFF
VOL
PC
VOL
VIDEO
AAAA
BBBB
DDDD
GGGG
Figure 2. Front Panels With and Without Faceplates
The buttons and encoders must be congured or programmed to carry out their functions.
A
Faceplate
B
Mounting Holes — EBP 50 has two holes, EBP 100 has four holes, and EBP 200 has 6 holes
C
Power Buttons — Control the power to a display
D
Volume Control Buttons (EBP 50 only) — Use the Volume Up and Volume Down buttons to adjust the audio volume.
E
Volume Control LEDs and Encoder (EBP 100 and EBP 200) — Use the encoder to adjust the volume level. The LEDs
provide a visual representation of the volume level.
F
Function Buttons — These buttons can be congured to carry out a variety of functions.
G
Reset Button — Resets the rmware to the factory installed version.
3
Product Category
To reset the firmware
1. Disconnect the eBUS cable that is providing power.
2. While reconnecting power, press and hold down the Reset button.
3. Release the Reset button 1 second after reconnecting power. During the reset process, the front panel buttons are not lit.
When the eBUS Connection Status LED lights, the reset process is complete.
Planning the System and Installation
When planning to install an eBUS system you must consider how many EBP button panels to use, maximum cable distance,
cabling topology, and mounting. See the eBUS Technology Reference Guide for more information about eBUS topologies.
Installation
Step 1: Get Ready
Use the following check list to prepare for the installation.
Download and install the latest version of the software, rmware, and device drivers needed to congure the IPCPPro
and control the connected AV products. See the IPCPPro Series User Guide (available at www.extron.com) for details on
software and drivers.
Obtain network information (IP addresses, passwords, DHCP settings, and the like) and the MAC address for the control
processor.
Obtain model names, drivers, and setup information for AV devices.
Determine which eBUS cabling topologies to use and obtain cables, mounting hardware, and any power supplies or hubs
required by that conguration (see the eBUS Technology Reference Guide for more information about eBUS topologies).
Step 2: Prepare the Installation Site
ATTENTION:
Installation and service must be performed by authorized personnel only.
L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
Extron recommends installing the EBP into a grounded, UL Listed electrical junction box.
Extron recommande d’installer le EBP dans un boîtier d’encastrement électrique mis à la terre, listé UL.
If the EBP will be installed into ne furniture, it is best to hire a licenced, bonded craftsperson to cut the access hole
and perform the physical installation so the surface will not be damaged.
S’il est prévu d’installer le EBP dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et qualié
pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
NOTE: For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the EBP must be
installed in a UL Listed junction box (not included with the EBP). The end user or installer must furnish the junction box.
Americans with Disabilities Act (ADA) compliance
When planning where to install these devices, you may need to consider factors affecting accessibility of the button panel such
as height from the oor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see
sections 307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the 2010 ADA Standards for Accessible Design available at
http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf.
Site preparation
Model US Gang Size
EBP 50 1
EBP 100 2
EBP 200 3
Extron offers an assortment of mud rings, optional ULListed in-wall junction boxes, external wall boxes, and surface or tabletop
mounting boxes for use with the eBUS button panels.
4
EBP US Gang Button Panels • Setup Guide (Continued)
Step 3: Change a Faceplate, Button Labels, or Knob
You can replace a faceplate or one or more of the labels within the buttons. Some button labels
ship with the unit. You can create and print your own customized labels using Extron Button
Label Generator software.
To change a bezel or button labels, follow these instructions.
1. The faceplate is held in place by magnets. It is removed by holding the body
of the unit with one hand, gripping the sides of the faceplate with the
other hand, and pulling the faceplate away from the unit.
2. Gently separate the button lens button cap from its white
diffuser: insert the end of the provided Extron removal
tool into the corner notch and gently twist the tool (see
gure 3,
1
).
3. Remove the label insert from the button cap.
TIP: If the insert does not come out easily, use a piece
of sticky tape to pull it out of the button cap.
4. Select one of the button labels from the printed label
sheets included with the unit. Remove the label from its
backing and remove the clear, protective lm from the
other side of the label.
5. Insert the button label into the button cap (
2
).
TEXT
Separate the
two-piece button
her
e at the corner.
Dif
fuser
Base
Insert
button label.
Button
Lens Cap
Removal
Tool
1
2
Figure 3. Replacing Buttons
To change a knob (EBP 100 and EBP 200 models only), follow
these instructions:
1. Remove the faceplate as described in step 1 above.
2. Firmly grasp the knob and pull it away from the EBP.
3. Align the ridge inside the new knob (gure 4,
1
) with the
channel on the knob control (
2
) and allow the magnet in the
knob to snap into place.
4. Reattach the faceplate to the unit as described in step 7
above.
2
1
Side View
Figure 4. Replacing the knob on EBP 100 or EBP 200
6. Align the cap with the white diffuser and the panel opening,
and press the clear cap into place on the button.
7. Attach the faceplate to the EBP by aligning the openings of
the faceplate with the buttons and knob and with the LEDs
and place the faceplate against the unit.
The magnetic catches fasten the faceplate onto the unit.
5
Product Category
Step 4: Set Bus ID Addresses
Up to eight devices can be connected to one control processor. In order for the control processor to be successfully congured,
each device connected to the same control processor must have a unique six-bit, BUS ID, which is set with the DIP switch
assembly on the side panel of the EBP (gure 1,
C
). If two or more modules have the same bus ID, address conicts may cause
one or more of the panels to not be recognized by the IPCPPro control processor.
Various combinations of the six DIP switches being set to On or Off, provide 64 addresses: 0 is a reserved eBUS ID and the
congurable eBUS ID range is 1 through 63 (see the table on the two following pages). The section below shows an example of
binary to decimal conversion.
eBUS ID Setup
DIP Switch
Position
Decimal
Off
1
2
5
=32
2
Off
2
4
=16
5
On
2
1
=2
4
Off
2
2
=4
3
Off
2
3
=8
6
Off
2
0
=1
Slide
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
Figure 5. eBUS ID Setup
Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device. In gure 5, only DIP
switch #5 is on and the rest are off, which means the address for the device in gure 5 is 0+0+0+0+2+0=2.
NOTES:
Any address can be used except address 0 (binary: 000000), which is reserved (as the address of the controller) and may
not be used.
Switch 1 (on the left) is the highest value (32, the most signicant bit) and is labelled MSB.
Switch 6 (on the right) is the lowest value (1, the least signicant bit) and is labelled LSB.
Up = on = 1, Down = off = 0
The following table shows the factory default BUS IDs and the corresponding addresses for the EBP US Gang Button Panel
models. These IDs can be changed to any valid value.
Model Address BUS ID
EBP 50 22 010110
EBP 100 3 000011
EBP 200 4 000100
The table on the following two pages shows the DIP switch settings for all 64 possible addresses.
6
EBP US Gang Button Panels • Setup Guide (Continued)
Setting eBUS ID Numbers
In the table below, a DIP switch setting shown as 0 is equivalent to Off. A DIP switch setting shown as 1 is equivalent to On.
NOTE: The ID number 0 (switch setting 000000) is reserved for the control processor and cannot be used by an eBUS device.
DIP Switch Setting
Decimal
Value
DIP Switch Setting
Decimal
Value
1 2 3 4 5 6 1 2 3 4 5 6
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 0 0 0
0
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 1 1 1
15
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 0 0 1
1
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 0 0 0
16
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 0 1 0
2
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 0 0 1
17
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 0 1 1
3
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 0 1 0
18
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 1 0 0
4
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 0 1 1
19
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 1 0 1
5
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 1 0 0
20
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 1 1 0
6
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 1 0 1
21
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 0 1 1 1
7
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 1 1 0
22
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 0 0 0
8
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 0 1 1 1
23
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 0 0 1
9
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 0 0 0
24
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 0 1 0
10
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 0 0 1
25
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 0 1 1
11
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 0 1 0
26
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 1 0 0
12
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 0 1 1
27
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 1 0 1
13
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 1 0 0
28
1 2
3
4
56
ON
M
S
B
L
S
B
0 0 1 1 1 0
14
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 1 0 1
29
7
Product Category
DIP Switch Setting
Decimal
Value
DIP Switch Setting
Decimal
Value
1 2 3 4 5 6 1 2 3 4 5 6
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 1 1 0
30
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 1 1 1
47
1 2
3
4
56
ON
M
S
B
L
S
B
0 1 1 1 1 1
31
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 0 0 0
48
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 0 0 0
32
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 0 0 1
49
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 0 0 1
33
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 0 1 0
50
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 0 1 0
34
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 0 1 1
51
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 0 1 1
35
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 1 0 0
52
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 1 0 0
36
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 1 0 1
53
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 1 0 1
37
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 1 1 0
54
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 1 1 0
38
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 0 1 1 1
55
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 0 1 1 1
39
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 0 0 0
56
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 0 0 0
40
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 0 0 1
57
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 0 0 1
41
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 0 1 0
58
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 0 1 0
42
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 0 1 1
59
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 0 1 1
43
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 1 0 0
60
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 1 0 0
44
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 1 0 1
61
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 1 0 1
45
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 1 1 0
62
1 2
3
4
56
ON
M
S
B
L
S
B
1 0 1 1 1 0
46
1 2
3
4
56
ON
M
S
B
L
S
B
1 1 1 1 1 1
63
8
EBP US Gang Button Panels • Setup Guide (Continued)
Step 5: Cable All Devices
Attach cables using the diagrams in this section as a guide. Connect a 4-pole captive screw connector to each end of the cable,
wiring both ends as shown in gure 6. In most cases the EBPs are powered by the IPCPPro control processor that provides the
eBUS signal. Power is carried on the V+ pin of each eBUS connection.
The four connectors are:
+V — carries 12 VDC power from the controller, active hub, or power supply
+S — carries the positive data signal
-S — carries the negative data signal
G — ground
Extron STP20-2/1000 or STP20-2P/1000 cable is recommended for eBUS connections.
Ground
+ Signal
+
12 VDC
-
Signal
Drain Wires (2)
G
-
S
+S
+V
Black
White
Green
Red
Figure 6. Basic eBUS Connector Wiring and Cable Color Code
NOTES:
The two eBUS ports are interchangeable: either port can be used to connect the device to a controller or EBDB
distribution hub and either can be used to daisy-chain the device to another EBP.
Connect up to eight eBUS devices for each IPCP Pro control processor.
Wire the connectors in the same way at both ends.
Do not exceed a total of 1000 feet (305 meters) of cable for connections between the IPCP Pro and all the EBP panels.
Do NOT power an EBP from more than one power source. Power is provided by the IPCP Pro. If additional power
is required, use a PS 1220EB power supply and distribution hub, or an Extron 12 VDC power supply. If more than
one power source is used in a system, make sure that the devices powered by the rst source are isolated from the
devices powered by the second source by disconnecting the +V pin appropriately (see gure 7 on the following page).
ATTENTION:
Always use a power supply supplied or specied by Extron. Use of an unauthorized power supply voids all regulatory
compliance certication and may cause damage to the supply and the unit.
Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked
“Class2” or “LPS” and rated output 12VDC, minimum 1.0A.
Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit être alimenté par une source
d’alimentation certiée UL de classe 2 ou LPS et paramétré à 12VDC et 1,0A minimum.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération
ou dans les cavités murales.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/
NFPA70, article725 and the Canadian Electrical Code part1, section16. The power supply shall not be permanently
xed to building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/
NFPA70, article725, et au Canadian Electrical Code, partie1, section16. La source d’alimentation ne devra pas être
xée de façon permanente à une structure de bâtiment ou à une structure similaire.
9
Product Category
EBPs that are relatively far from the control processor (see the eBUS Technology Reference Guide at www.extron.com for
details) can be connected to an optional Extron PS1220EB eBUS power inserter (see gure 7), or an Extron 12VDC desktop
power supply (see gure 8).
PWR LOAD = X.XW
+V +S -S G+V +S -S G
eBUS
BUS ID
M
S
B
L
S
B
12
ON
3456
PWR OUT = 6W
V
C
G
VOL
P
O
WE
R
12V
1.
0
A MA
X
G
T
x
R
x
R
T
S
C
T
S
COM 1
3
1
2
4
G
DIGITAL I/O
G
Tx R
x
COM 2
-S+V +S G
eBUS
C
1
2
RELAYS
S
G
IR/S
LAN
IPCP PRO 250
M
A
C
:
00
-
05
-A
6
-
XX
-
XX
-
XX
S/
N: ####### E#####
#
IPCP Pro
eBUS Connections
Connect up to ve (5) eBUS
endpoint devices to the PS 1220EB.
Wire the connectors the same at both
ends.
All ports are identical and
interchangeable.
Power Input
(100-240 VAC,
50-60 Hz)
PS 1220EB
ATTENTION: Do NOT connect the
power pin to any device that is already
powere d by the IPCP Pro control
processor or by an additional power
supply.
3/16"
(5 mm)
Max.
Ground
+ Signal
+12 VDC
-
Signal
Ground
+ Signal
-
Signal
X
X
Tie drain wires
to ground.
EBP 100
eBUS 24 WATTS MAX
100-240V 50-60Hz
0.6A MAX
-S+V +S G-S+V +S G-S+V +S G
-S+V +S G-S+V +S G-S+V +S G
Figure 7. Cabling an eBUS System with an PS 1220EB Power Supply and Distribution Hub
Tie drain wires to ground.
RidgedSmooth
3/16" (5 mm) Max.
Ground
+ Signal
-
Signal
Ground
+ Signal
-
Signal
+12 VDC
NOTE:
Check the polarity of the power
supply before connecting it to the EBP.
PWR OUT = 6W
V
C
G
VOL
PO
WER
12V
1
.
0
A MAX
G
Tx
Rx
R
T
S
C
T
S
COM 1
3
1
2
4
G
DIGITAL I/O
G
Tx
Rx
COM 2
-S+V +S G
eBUS
C
1
2
RELAYS
S
G
IR/S
LAN
IPCP PRO 250
M
AC: 00-05-A6
-
XX-XX-X
X
S/
N: ####### E#####
#
IPCP Pro
External Power Supply
(12 VDC, 1.5 A max.)
Ground
all Devices
– Return
+12 VDC input
PWR LOAD = X.XW
+V +S -S G+V +S -S G
eBUS
BUS ID
M
S
B
L
S
B
12
ON
3456
EBP 100
PWR LOAD = X.XW
+V +S -S G+V +S -S G
eBUS
BUS ID
M
S
B
L
S
B
12
ON
3456
EBP 100
Figure 8. Cabling EBP Panels with an Extron Power Supply
10
EBP US Gang Button Panels • Setup Guide (Continued)
Step 6: Configure or Program the System
EBPs are shipped with pre-labelled buttons in place but these buttons do not have any functions associated with them until
they are congured with Global Congurator or programmed with Global Scripter. See the Global Configurator Help File or the
Global Scripter Help File for step-by-step instructions and detailed information.
Step 7: Test and Troubleshoot
1. Verify that the DIP switches on the EBPs are set to the desired address on each device and that there are no BUS ID conicts
in the system (see Step 4: Set Bus ID Addresses on page 5).
2. The eBUS status LEDs (see figure 1,
A
, on page 1) provide information about power and communication status and bus
ID address conicts.
The EBP 100 and EBP 200 have a single green LED that provides information as follows:
Off — The device is not receiving power.
Slow blink (1 blink every second)— The device is receiving power but communication with the control processor is not
conrmed.
Fast blink (2 blinks per second) — There is a BUS ID address conict.
Lights solidly — Power and communication are both conrmed.
The EBP 50 has three LEDs:
Off — If all three LEDs are off, the device is not receiving power.
Yellow LED— Lights solidly when the device is receiving power but communication with the control processor is not
conrmed.
Red LED— Lights solidly when there is a BUS ID address conict.
Green LED — Lights solidly when power and communication are both conrmed.
3. Verify that cables to and from the EBPs are wired in the same way at each end (pin 1 to pin 1, pin 2 to pin 2, and so forth).
4. Test the system.
Press buttons on the EBPs and ensure the buttons light as desired and that the appropriate control commands or
functions are triggered.
Ensure that the audio output responds correctly to the volume knob or button. Also ensure that the volume LEDs light
correctly as you increase or decrease the audio gain.
5. Make adjustments to wiring, BUS ID address, or system conguration as needed. Remember that the rear panel ports
and DIP switches will not be accessible after the EBP is mounted. If needed, upload a revised conguration to the control
processor.
If you have questions during installation and setup, contact the ExtronS3 Sales & Technical Support or the ExtronS3 Control
Systems Support Hotline (1.800.633.9877).
11
Product Category
Step 8: Mount the EBPs
EBP panels can be installed directly into the wall using a 1-gang (EBP 50), 2-gang (EBP 100), or 3-gang (EBP 200) wall mounting
bracket (mud ring), wall or surface mounting box or UL-Listed junction box.
ATTENTION:
All electrical installation should be performed by qualied personnel in accordance with local and national building codes,
re and safety codes, and local and national electrical codes.
Toute installation électrique devrait être effectuée par un personnel qualié, conformément aux codes du bâtiment, aux
codes incendie et sécurité, et aux codes électriques locaux et nationaux.
NOTES:
The wall box is not provided and must be purchased separately.
Install the wall box by following the instructions provided by the manufacturer.
If the unit is not installed in a mounting bracket, you must install the provided plastic spacer. The spacer positions the
unit to allow the magnetic faceplate to attach properly and securely.
Before mounting
1. Decide where to locate the panel. Take into consideration the position of wall studs and windows that could obstruct cable
runs.
2. If required, install the electrical wall box by following the instructions provided by the manufacturer.
Or install the provided wall mounting bracket by following these instructions.
a. Cut a hole in the wall or furniture:
EBP 50 (1-gang) — 3.7" (94 mm) H x 2.2" (56 mm) W
EBP 100 (2-gang) — 3.7" (94 mm) H x 4.0" (102 mm) W
EBP 200 (3-gang) — 3.75" (95 mm) H x 5.9" (150 mm) W
b. Turn the screws on the front of the mounting bracket counterclockwise so that the locking arms are ush with the edges
of the bracket.
c. Insert the bracket into the hole. If necessary, enlarge the hole with a le or rasp.
d. Turn the screws on the front of the mounting bracket clockwise so that the locking arms rotate and secure the bracket
against the wall. Do not overtighten the locking arms.
3. Disconnect power from all devices at the source and run the cables through the wall or furniture and, if required, through the
plastic spacer.
4. Connect the cables to the EBP rear panel (see figure 1 on page 1 and see Step 5: Cable All Devices on page 8).
5. If you have not already done so, set the DIP switches to give the panel a unique BUS ID (see Step 4: Set Bus ID Addresses
on page 5).
12
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics,
see the Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2016-2019 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
EBP US Gang Button Panels • Setup Guide (Continued)
68-2907-50 Rev. C
10 19
Mounting
The following diagrams show how to mount the EBP 100. Use the same procedure to mount the EBP 50 or EBP 200.
Extron
DISPLAY
VOLUME
22
1
1
EBP 100
Wall Mounting
Bracket
(Mud Ring)
Faceplate
Wall
MUTE
MUTE
Extron
DISPLAY
VOLUME
22
1
1
Wall
Wall
Bo
x
Faceplate
EBP 100
Plastic Spacer
Figure 9. Mounting the EBP 100 with a Wall Mounting Bracket (left) or a Junction Box (right)
1. Insert the cabled EBP into the mud ring or junction box, aligning the mounting holes in the EBP with those in the box or mud
ring. The EBP 50 (1 gang) has two mounting holes, the EBP 100 (2 gang) has four mounting holes, and the EBP 200 (3 gang)
has six mounting holes.
2. Secure the EBP to the junction box, wall or surface mounting box, or mud ring, using the included screws (see gure 9,
1
).
3. Using a Phillips screwdriver, lightly tighten the screws until snug.
4. Attach the faceplate to the EBP: align the faceplate openings with the buttons, knob (if applicable), and LEDs (if applicable)
and place the faceplate against the unit (
2
). Magnetic catches hold the faceplate securely to the front of the unit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Extron EBP 200 Manuel utilisateur

Catégorie
Boîtiers de commutation série
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues