Sun Microsystems Sun Storage J4400 Replacement Manual

Taper
Replacement Manual
Sun Microsystems, Inc.
www.sun.com
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Storage J4400 Array
Chassis Replacement Guide
Part No. 820-4601-10
April 2008, Revision A
Please
Recycle
Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.
Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without
limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or
more additional patents or pending patent applications in the U.S. and in other countries.
This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and
decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of
Sun and its licensors, if any.
Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, and Solaris are trademarks or registered trademarks of Sun Microsystems,
Inc. in the U.S. and in other countries.
All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other
countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.
U.S. Government Rights—Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and
applicable provisions of the FAR and its supplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés.
Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la
limitation, ces droits de propriété intellectuels peuvent inclure un ou plus des brevets américains énumérés à http://www.sun.com/patents et
un ou les brevets plus supplémentaires ou les applications de brevet en attente dans les Etats-Unis et dans les autres pays.
Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la
décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans
l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a.
Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des
fournisseurs de Sun.
Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.
Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, et Solaris sont des marques de fabrique ou des marques déposées de Sun
Microsystems, Inc. aux Etats-Unis et dans d’autres pays.
Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc.
aux Etats-Unis et dans d’autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun
Microsystems, Inc.
L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique
pour l’industrie de l’informatique. Sun détient une license non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant également les licenciées de Sun qui mettent en place l’interface d ’utilisation graphique OPEN LOOK et qui en outre se conforment
aux licences écrites de Sun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFAÇON.
iii
Contents
Replacing a J4400 Array Chassis 1
Prerequisites 1
Verifying a Chassis Failure 1
ESD Precautions 2
Removing a Chassis 2
Installing the New Chassis 9
Installing CRUs Into a New Chassis 11
Completing the Chassis Installation 14
Related Documentation 15
iv Sun Storage J4400 Array Chassis Replacement Guide April 2008
1
Replacing a J4400 Array Chassis
This document describes replacement procedures for the Sun Storage J4400 Array
chassis.
Caution Only trained service personnel should remove the covers on this
equipment.
This product is intended for restricted access whereby access is controlled through
the use of a means of security (for example, key, lock, tool, badge access), and
personnel authorized for access have been instructed on the reasons for the
restrictions and any precautions that need to be taken.
Prerequisites
Before you start to replace a failed chassis, you must:
Back up all data stored on the array.
Stop all system I/O to the array.
Verify that the failed chassis is ready to be removed.
Prepare the work site and observe all “ESD Precautions” on page 2.
Remove all power from the chassis and chassis components.
Verifying a Chassis Failure
To determine that a chassis has failed, check the following:
The array System Power/Status LED (front) is amber.
2 Sun Storage J4400 Array Chassis Replacement Guide April 2008
The audible alarm is sounding.
All of the component fault LEDs are green.
Disk drive ID/Status LEDs (front) are green
SIM Power LED (back) is green
Power supply module LEDs (back) are green
Note A steady amber LED on any component indicates a problem with that
component.
ESD Precautions
Observe the following electrostatic discharge (ESD) precautions:
Remove all plastic, vinyl, and foam material from the work area.
Wear an antistatic wrist strap at all times when handling any CRU.
Before handling any CRU, discharge any static electricity by touching a grounded
surface.
After removing a CRU from the cabinet, immediately place it on an antistatic mat.
Handle any card that is part of a CRU by its edges only and avoid touching the
components or circuitry.
Do not slide a CRU over any surface.
Limit body movement (which builds up static electricity) during the removal and
replacement of a CRU.
Removing a Chassis
Caution You must remove power from the chassis that needs to be replaced
before starting this procedure. All interconnected trays will be disrupted during this
procedure. Powering off one J4400 Array tray causes loss of access to other
interconnected trays.
1. From the back of the cabinet, locate the chassis (also referred to as a tray) that is
being replaced (see “Verifying a Chassis Failure” on page 1).
2. Disconnect the power cord from each power supply (see
FIGURE 1):
Replacing a J4400 Array Chassis 3
a. Remove the power cord tie strap from each power cord.
b. Disconnect each power cord from its power supply connector (see
FIGURE 1).
FIGURE 1 Removing the Power Cable and Mini-SAS Cables
Caution For products with multiple power cords, all power cords must be
disconnected to completely remove power from the system.
3. Label each mini-SAS cable connection (see
FIGURE 1) for reconnection to the
same connectors on the replacement chassis. For example, “Tray 1, SIM Link
Out to Tray 0, Host or SIM Link IN.”
4. Disconnect the labeled mini-SAS cables from each SIM board.
a. Grasp the metal body of the connector with one hand, and use your other
hand to firmly grasp and pull the tab.
b. Pull the tab gently toward the connector body, and, then with your other
hand, extract the connector from the bulkhead.
Connection Between
Tray 0 and Tray 1
Connection from Host
or SIM Link IN to
Management Host
Power Cord
4 Sun Storage J4400 Array Chassis Replacement Guide April 2008
Caution Do not twist the tab or pull it in any direction other than parallel with
the connector body. If the tab breaks, use a small sharp object (such as a fine-tipped
screwdriver) to lift the metal spring at the top of the connector shell to unlatch it (see
FIGURE 1).
Caution Electrical Shock Hazard. The power supplies in this equipment can
produce high energy hazards. Only instructed personnel with authorized access to
this equipment can remove and replace modules in the system.
a. Loosen the two captive thumb screws on the power supply ejection levers
and swing the ejection levers fully outward to partially eject the power
supply from the tray (see
FIGURE 2).
b. Pull the power supply out of the tray.
c. Place the power supply aside.
FIGURE 2 Removing a Power Supply
Replacing a J4400 Array Chassis 5
5. Remove each SIM board from the chassis (see FIGURE 3).
Caution Possible lose of configuration data. Label the SIM boards (SIM 0 and
SIM 1) as you remove them from the faulty chassis, and reinstall them in the new
chassis in the same slot order to prevent possible loss of driver configuration data.
a. Loosen the captive thumb screws on the ejection levers and pull the
ejections levers out fully to partially eject the SIM board from the tray.
b. Pull the SIM board from chassis (see
FIGURE 3).
c. Place the SIM board aside in a static-free environment.
FIGURE 3 Removing a SIM Board From the Chassis
6 Sun Storage J4400 Array Chassis Replacement Guide April 2008
6. From the front of the cabinet, remove each disk drive and disk filler assembly
(see
FIGURE 4).
Caution Potential loss of data access - Data might be lost if an active disk drive
is removed. If you remove an active disk drive accidentally, wait at least 30 seconds
before reinserting it.
Caution Potential loss of configuration information or data - Label each disk
drive with the slot from which it was removed, and reinstall each drive in the
identical slot location in the replacement chassis.
a. Press the release button in and to the right to release the disk extraction
lever.
b. Swing the extraction lever fully out and to the right to partially extract the
disk drive from the tray.
c. Grasp the middle of the disk drive and pull it toward you to remove it from
the tray (see
FIGURE 4).
FIGURE 4 Removing a Disk Drive or Disk Filler Assembly
Replacing a J4400 Array Chassis 7
d. Record the slot location on the outer drive casing. Use the same slot location
when installing each disk drive in the new chassis.
e. Store each disk drive in a static-free environment.
7. After you have removed all of the components from the chassis, remove the
chassis from the cabinet (see
FIGURE 6).
Caution The empty weight of a chassis is 14 kg (32 lbs). You might need two
people to remove the chassis from the cabinet.
a. Remove the two system locking clips from the lower corners of the rear
chassis (see ). You can use a Phillips head screwdriver for leverage to help
you pull out each clip. Set the clips aside.
FIGURE 5 Removing the System Locking Clips
b. From the front of the cabinet, loosen the four captive screws, two on either
side of the tray.
Locking Clip Installed
Locking Clip
Mounting Rail
J4400 Tray
8 Sun Storage J4400 Array Chassis Replacement Guide April 2008
c. Grasp each side of the chassis and pull it toward you, and remove it from the
cabinet (see
FIGURE 6).
FIGURE 6 Removing the Failed Chassis From the Cabinet
d. Package the failed chassis and return it to Sun, if instructed to do so, or
properly dispose of it.
Replacing a J4400 Array Chassis 9
Installing the New Chassis
Caution Follow all “ESD Precautions” on page 2 and use care when handling all
components.
1. From the front of the cabinet, slide the new chassis into the cabinet until the
front flanges of the chassis touch the vertical face of the cabinet (see
FIGURE 7).
FIGURE 7 Installing the New Chassis in the Cabinet
2. Tighten the captive screws on each side of the tray front to secure the chassis to
the cabinet.
10 Sun Storage J4400 Array Chassis Replacement Guide April 2008
3. At the back of the cabinet, slide a system locking clip onto each lower corner of
the chassis (see
FIGURE 8). You can use a Phillips head screwdriver for leverage
to help you push in the clip.
FIGURE 8 Installing the System Locking Clips
Locking Clip Installed
Locking Clip
Mounting Rail
J4400 Tray
Replacing a J4400 Array Chassis 11
Installing CRUs Into a New Chassis
1. From the front of the cabinet, install each disk drive and disk filler assembly
into (see
FIGURE 9). For each disk drive and disk filler assembly:
Caution Possible loss of configuration information or data - Reinstall each drive
into the identical slot location from which it was removed in the failed chassis, as
defined by the notation written on the drive outer case when each drive was
removed.
a. Unlatch and swing the extraction lever to its fully open position.
b. Align the disk component with the open slot and slide the drive into the tray
until the extraction lever engages with the tray connectors and the lever
begins to swing closed.
c. Press the extraction lever closed until it snaps in place on the disk front
panel to seat the drive into the tray.
FIGURE 9 Installing the Disk Drives and Filler Assemblies in New Chassis
12 Sun Storage J4400 Array Chassis Replacement Guide April 2008
2. From the back of the cabinet, install the two SIM boards in the SIM slots (see
FIGURE 10).
Caution Possible incorrect configuration or driver information - Reinstall the
SIM boards into the identical slot locations from which they were removed in the
failed chassis.
For each SIM board:
a. Swing both extraction levers to the fully open position.
b. Align the SIM board with the open slot and slide it into the tray until it
engages with the tray connectors and the extraction levers begin to swing
closed.
c. Simultaneously push both extraction levers toward the middle of the board
to seat it in the tray.
d. Tighten the extraction lever captive screws to secure the board.
FIGURE 10 Installing a SIM Board
Replacing a J4400 Array Chassis 13
3. Install the two power supplies into the chassis slots (see FIGURE 11).
For each power supply:
a. Swing both extraction levers to the fully open position.
b. Align the power supply with the open slot and slide it into the tray until it
engages with the tray connectors and the extraction levers begin to swing
closed.
c. Simultaneously push both extraction levers toward the middle of the power
supply to seat it in the tray.
d. Tighten the extraction lever captive screws to secure the power supplies.
FIGURE 11 Installing a Power Supply
14 Sun Storage J4400 Array Chassis Replacement Guide April 2008
Completing the Chassis Installation
Caution Possible incorrect configuration or loss of data - Reconnect all mini-SAS
cables to their original locations on each SIM board in the new chassis.
1. From the back of the cabinet (see
FIGURE 12), reconnect the country-specific
power cables into each of the power supply connectors.
2. Replace the power cord tie strap on each power cord.
3. Turn on power to both power supplies.
FIGURE 12 Reconnecting the Mini-SAS and Power Cables
Connection Between
Tray 0 and Tray 1
Power Cord
Connection from Host
or SIM Link IN to
Management Host
Replacing a J4400 Array Chassis 15
4. Check the status of the tray.
After the power-on sequence is complete, confirm the following:
The green OK/Power LEDs on each drive in the tray are steady on.
If all tray and drive OK/Power LEDs are steady green and the amber Service
Required LEDs are off, the power-on sequence is complete and no faults have
been detected.
The amber LED is blinking for any module.
Reseat the module to make sure that it is properly installed. If the LED is now
green, the module is functioning properly. If the module remains blinking amber,
contact Sun Customer Service Personnel.
The alarm shuts off after connecting the second power cord.
If an alarm sounds after plugging in the first power cord, the alarm will shut off
once the second power cord is connected.
Related Documentation
For additional information about the Sun Storage J4400 Array chassis, see the
following product documentation:
Application Title Part Number
Regulatory and safety
information
Sun StorageTek Regulatory and Safety
Compliance Manual
96272, Revision A
Multilanguage safety
information
Important Safety Information for Sun
Hardware Systems
816-7190-nn
Site planning information Sun Storage J4200/J4400 Array Site
Preparation Guide
820-3219-nn
Installation at a glance Sun Storage J4200 Array Setup Poster 820-3221-nn
Installation at a glance Sun Storage J4400 Array Setup Poster 820-4691-nn
Complete details of the
hardware components, rail
and tray installation, and
cabling.
Sun Storage J4200/J4400 Array Hardware
Installation Guide
820-3218-nn
Late-breaking information
not included in the
information set
Sun Storage J4200/J4400 Array Release
Notes
820-3222-nn
16 Sun Storage J4400 Array Chassis Replacement Guide April 2008
Service Contact Information
If you need help installing or using this product in the United States, call
1-800-USA-4SUN(872-4786), or go to:
http://www.sun.com/service/contacting/index.xml
Installation and use of the
management software using
a GUI
Sun StorageTek Common Array Manager
User Guide for the J4000 Array Family
820-3765-nn
Installation and use of the
management software using
a CLI
Sun StorageTek Common Array Manager
CLI Guide for the J4000 Array Family
820-4419-nn
General operation and
troubleshooting
Sun Storage J4200/J4400 Array Overview 820-3223-nn
Disk drive replacement
procedures
Sun Storage J4200/J4400 Array Disk Drive
Replacement Guide
820-3225-nn
SIM board replacement
procedures
Sun Storage J4200 Array SIM Board
Replacement Guide
820-3226-nn
SIM board replacement
procedures
Sun Storage J4400 Array SIM Board
Replacement Guide
820-4600-nn
Power supply replacement
procedures
Sun Storage J4200 Array Power Supply
Replacement Guide
820-3227-nn
Fan replacement procedures Sun Storage J4200 Array Fan Replacement
Guide
820-3229-nn
Power supply and fan
replacement procedures
Sun Storage J4400 Array Power
Supply/Fan Replacement Guide
820-3228-nn
Chassis replacement
procedures
Sun Storage J4200 Chassis Replacement
Guide
820-4413-nn
Chassis replacement
procedures
Sun Storage J4400 Chassis Replacement
Guide
820-4601-nn
Rail kit installation
procedures
Sun Storage J4200/J4400 Array Rail Kit
Installation Guide
820-3764-nn
Application Title Part Number
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Sun Microsystems Sun Storage J4400 Replacement Manual

Taper
Replacement Manual

dans d''autres langues