3.5 Manual Start and Stop
Up to eight (8) speeds may be started from the
controller. Manual operation of speeds "eStar" through
"4" differs from manual operation of speeds "5" through
"8".
NOTE When starting the pump, the pump will rst run
at the priming speed for the priming duration, as
set by the installer.
Speeds eStar through 4
To start the pump manually running at speeds
"eStar" through "4", press button "" through "4"
corresponding to the desired speed. The associated LED
will light red and the controller enters the RUN mode.
234
MENU
2:SPEED 2
10:00AM RPM: 1200
To stop the pump, press the button again. The associated
LED will extinguish and the pump and controller will
return to the OFF mode.
Speeds 5 through 8
To start the pump manually at speeds "5" through
"8", press the MENU button. The controller displays
SELECT PRESET/N:LABEL, where n:label is the
number and label of the last selected speed "5" through
"8".
Using the arrow keys, select the desired speed to
activate, and then press MENU to enter RUN mode,
starting the pump running at the selected speed.
234
SELECT PRESET
5:SPEED 5
MENU
To stop the pump, press MENU. To exit without starting
the pump, press any button "" through "4".
3.6 Pump Speed Setting
With the exception of preset "", each speed may be
adjusted while the pump is running in that speed mode.
Preset "" is reserved for the eStar function, and its
speed is set by the installer.
To adjust the pump speed, the controller must be in the
RUN mode. While in RUN mode, the controller displays
the pump speed. Adjust the speed by pressing the up or
down arrow keys. The speed is saved by the controller
and will remain until changed again.
NOTE Pump speed is adjustable only within a certain
range. The minimum and maximum limits of the
range are set by the installer.
NOTE When used with a solar heat system, set speed
to at least 3000 RPM and potentially up to 3450
RPM, based on the pump's head required to
push the water up a minimum of 12-15 feet.
2:SPEED 2
10:00AM RPM: 1400
3.7 Timeclock Setup and Operation
NOTE The controller has a non-replaceable battery back-up
that keeps time, programs, and speed settings when power is
disconnected and should never require replacement.
The controller allows the user to create timed pump
programs on pump speeds (presets) "" and "2". The
two timers operate independently of each other, and may
overlap in time if desired.
Timeclock Setup
Start the desired speed, "" or "2". Press MENU. The
controller enters the Timeclock setup mode. Using the
arrow keys, select ON TIME and press MENU. Set the
desired pump turn-on time using the arrow keys and
press MENU. The time is stored. Select OFF TIME using
the arrow keys and press MENU. Set the desired pump
turn-off time using the arrow keys and press MENU. The
time is stored.
2:SPEED 2 TIMECLOCK
ON TIME
Using the arrow keys, select TIMECLOCK. Select
ENABLE using the arrow keys. The program is now
enabled to run. Press the speed button ("" or "2") to
return to the RUN mode.
PAGE 12 JEP-R Variable-Speed Pump Controller | Installation Manual