Mitsubishi Electric PAC-YT53CRAU Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

– 1 –
GB
Safety precautions............................................................... 2
Names and functions of controller components .................. 4
Controller interface .......................................................... 4
Display............................................................................. 5
Basic operations.................................................................. 6
Operation mode............................................................... 6
Preset temperature.......................................................... 7
Fan speed........................................................................ 8
Vane ................................................................................ 8
Controller operation - Function settings .............................. 9
Temperature range restriction ......................................... 9
Operation lock setting.................................................... 10
Mode skip setting........................................................... 10
Backlight brightness setting........................................... 11
Specifications .................................................................... 12
Icon explanations
The square icons used in this manual indicate as follows.
Indicates settings that can be changed only while the
units are in operation.
Indicates settings that can be changed only while the
units are stopped.
Indicates functions that are not available when the
buttons are locked or the system is centrally controlled.
Prior to use, thoroughly read the instructions in this manual to use the product correctly.
Retain for future reference.
Make sure that this manual and Installation Manual are passed on to any future users.
To ensure safety and proper operation of the remote controller, the remote controller should only be
installed by qualified personnel.
ON
OFF
CITY MULTI Control System
and Mitsubishi M-Series and P-Series Air Conditioners
Simple MA Remote Controller PAC-YT53CRAU
Instruction Book
F
WT06428X01_GB.fm Page 1 Friday, December 16, 2011 9:51 AM
– 2 –
GB
Safety precautions
Read the following safety precautions before using the controller.
Observe these precautions carefully to ensure safety.
After reading this manual, provide this manual to end user for future reference.
Keep this manual for future reference and refer to it as necessary. This manual should be made
available to those who repair or relocate the controller. Make sure that the manual is forwarded to
future end users.
WARNING
CAUTION
WARNING
WARNING
Indicates a risk of death or serious injury if you misuse the PAC-YT53CRAU.
CAUTION
Indicates a risk of serious injury or structural damage if you misuse the
PAC-YT53CRAU.
General precautions
Precautions for moving or repairing the controller
Do not install the unit in a place where large amounts of
oil, steam, organic solvents, or corrosive gases, such
as sulfuric gas, are present or where acidic/alkaline
solutions or sprays are used frequently. These
substances can compromise the performance of the
unit or cause certain components of the unit to corrode,
which can result in electric shock, malfunctions,
smoke, or fire.
To reduce the risk of shorting, current leakage, electric
shock, malfunctions, smoke, or fire, do not wash the
controller with water or any other liquid.
To reduce the risk of electric shock, malfunctions,
smoke or fire, do not operate the switches/buttons or
touch other electrical parts with wet hands.
When alcohol sterilization is performed, ventilate the
air to remove the gas.
To reduce the risk of injury or electric shock, stop the
operation and switch off the power supply before
cleaning, maintaining, or inspecting the controller.
To reduce the risk of injury or electric shock, before
spraying a chemical around the controller, stop the
operation and cover the controller.
If any abnormality (e.g., burning smell) is noticed, stop
the operation, turn off the power switch, and consult
your dealer. Continuing the operation may result in
electric shock, malfunctions, or fire.
Properly install all required covers to keep moisture
and dust out of the controller. Dust accumulation and
water can cause electric shock, smoke, or fire.
To reduce the risk of damage to the controller, do not
directly spray insecticide or other flammable sprays on
the controller.
To reduce the risk of electric shock or malfunctions, do
not touch the touch panel, switches, or buttons with a
pointy or sharp object.
To reduce the risk of injury and electric shock, avoid
contact with sharp edges of certain parts.
To reduce the risk of injury, wear protective gear when
working on the controller.
Consult your dealer for the proper disposal of the
controller.
The controller should be repaired or moved only by
qualified personnel.
Do not disassemble or modify the controller.
Improper installation or repair may cause injury, electric
shock, or fire.
WT06428X01_GB.fm Page 2 Friday, December 16, 2011 9:51 AM
– 3 –
GB
CAUTION
Additional precautions
To reduce the risk of shorting, electric shock, fire, or
malfunction, do not touch the circuit board with tools or
with your hands, and do not allow dust to accumulate
on the circuit board.
To avoid damage to the unit, use appropriate tools to
install, inspect, or repair the unit.
To avoid discoloration, do not use benzene, thinner, or
chemical rag to clean the controller.
To clean the controller, wipe with a soft cloth soaked in
water with mild detergent, wipe off the detergent with a
wet cloth, and wipe off water with a dry cloth.
WT06428X01_GB.fm Page 3 Friday, December 16, 2011 9:51 AM
– 4 –
GB
Names and functions of controller components
Controller interface
Backlit LCD
TEMP. button (See Page 7.)
MODE button (See Page 6.)
ON/OFF lamp
ON/OFF button
FAN button (See Page 7.)
VANE button (See Page 8.)
* To set the functions that are not available on this controller (PAC-YT53CRAU) such as Louver,
use MA remote controller or the centralized controller.
The lamp will light up in green when
turned on, and blink during startup
and when an error occurs.
Pressing this button starts and
stops the operation.
WT06428X01_GB.fm Page 4 Friday, December 16, 2011 9:51 AM
– 5 –
GB
Display
*2 icon
For M-Series and P-Series, when an error occurs, power indicator will blink, and refrigerant address (two digits),
error code (two digits), and unit No. will blink.
For City Multi, when an error occurs, power indicator will blink, and unit address (three digits) and error code (four
digits) will blink.
Check the error status, stop the operation, and consult your dealer.
When only error code blinks, air conditioning units stay in operation, but an error may have occurred.
Check the error code, and consult your dealer.
[M-Series and P-Series] [City Multi]
[M-Series and P-Series] [City Multi]
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Refrigerant
address and unit
attribute appear
alternately.
Error code and
unit No. appear
alternately.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Unit address
blinks.
Error code
blinks.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Error code
blinks.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Error code
blinks.
icon appears while the unit is operated in the
energy-save mode
* All icons are displayed for explanation.
icon appears when Operation lock setting is
effective. (See page 10.)
icon appears when indoor unit functions are set up.
(Refer to the Installation Manual.)
Fan speed icon
Vane icon
icon appears when the power is on.
Indoor temperature
Operation modes
CENTRAL icon *1
CHECK icon *2
Preset temperature *3
*1 icon
Appears when one of the following local operations is prohibited: ON/OFF; operation mode; preset temperature;
fan speed; vane.
CENTRAL
*3 Preset temperature
* Centigrade or Fahrenheit is selectable. Refer to the Installation Manual for details.
In COOL, DRYING, HEAT, or
AUTO (single set point) modes
In AUTO (dual set point) or
SETBACK modes
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Preset
temperature
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Heating preset
temperature
Cooling preset
temperature
WT06428X01_GB.fm Page 5 Friday, December 16, 2011 9:51 AM
– 6 –
GB
Basic operations
Pressing the button will change the operation mode in the following order.
*1: Not all functions are available on all models of indoor units. Functions that are not available will not
appear on the display.
*2: The preset temperature for AUTO (either single or dual set point) mode will appear depending on
the indoor unit model.
*3: Available only on the M-Series and P-Series unit interlocked with LOSSNAY unit.
"VENTI." will light up when LOSSNAY unit operates while the unit is in operation.
AUTO (dual set point) mode:
In AUTO (dual set point) mode, the preset temperatures can be set for cooling and heating, and
operation can be switched automatically between cooling and heating depending on the room
temperature.
The preset temperatures for cooling and heating set in AUTO (dual set point) mode will be reflected
to the temperature setting for COOL/DRYING and HEAT modes.
SETBACK mode:
The SETBACK function automatically switches the operation mode between cooling and heating to
maintain the room temperature within the set temperature range.
The preset temperatures for cooling and heating set in SETBACK mode can be different from the
preset temperatures for other modes.
Operation mode
MODE
COOL HEATAUTOFANDRYING SETBACK VENTI.
*1 *1 *1 *1*1, *2 *1, *3
During operation in AUTO (dual set point) mode
Preset temp.
(COOL)
Preset temp.
(HEAT)
HEAT
Room
temperature
HEATCOOL COOL
The room temperature
changes corresponding
to the change in the
outside temperature.
During operation in SETBACK mode
Preset temp.
(COOL)
Preset temp.
(HEAT)
HEAT
Room
temperature
HEATCOOL COOL
The room temperature
changes corresponding
to the change in the
outside temperature.
WT06428X01_GB.fm Page 6 Friday, December 16, 2011 9:51 AM
– 7 –
GB
In COOL, DRYING, HEAT, and AUTO (single set point) modes
Pressing the button increases the preset temperature.
Pressing the button decreases the preset temperature.
In AUTO (dual set point) and SETBACK modes
* During the preset temperature setting, the setting will automatically turn off if the or
button is left untouched for a certain period of time.
Preset temperature
ON
TEMP.
TEMP.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Cooling preset temperature
Heating preset temperature
Current operation mode
Current preset temperature (cooling/heating) appears.
* The example shows the display in AUTO (dual set point) mode.
When the or button is pressed, the preset temperature
(cooling/heating) display blinks.
TEMP.
TEMP.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
While the preset temperature (cooling/heating) display blinks, pressing the
button increases the preset temperatures for both cooling and heating,
and pressing the button decreases the preset temperatures for both
cooling and heating.
When the button is pressed, only the cooling preset temperature display
blinks.
TEMP.
TEMP.
MODE
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
While the cooling preset temperature display blinks, pressing the button
increases the cooling preset temperature, and pressing the button
decreases the cooling preset temperature.
When the button is pressed, only the heating preset temperature display
blinks.
TEMP.
TEMP.
MODE
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
While the heating preset temperature display blinks, pressing the
button increases the heating preset temperature, and pressing the
button decreases the heating preset temperature.
Pressing the button completes the preset temperature setting.
TEMP.
TEMP.
MODE
TEMP.
TEMP.
WT06428X01_GB.fm Page 7 Friday, December 16, 2011 9:51 AM
– 8 –
GB
Preset temperature range is as follows.
*1 Preset temperature range varies depending on the indoor unit model to be connected.
Refer to the Indoor unit Instruction Book for details.
*2 The preset temperatures for cooling and heating for AUTO (dual set point) mode will be used for those for
COOL/DRYING and HEAT mode.
*3 The preset temperatures for cooling and heating can be set under the following conditions.
• The cooling preset temperature is greater than the heating preset temperature.
• The difference between the cooling and heating preset temperatures is equal or greater than the minimum
temperature difference that varies depending on the indoor unit model to be connected.
Pressing the button will change the fan speed in the following order.
* The settable fan speed varies depending on the indoor unit model to be connected.
* If the unit has no fan setting function, the fan speed cannot be set.
In this case, the fan icon blinks when the button is pressed.
Pressing the button will switch the vane directions.
* The settable vane direction varies depending on the indoor unit model to be connected.
* If the unit has no vane function, the vane direction cannot be set.
In this case, the vane icon blinks when the button is pressed.
Operation mode Preset temperature range
COOL/DRYING 67 - 87 (95)°F/19 - 30 (35)°C *1
HEAT 63 (40) - 83°F/17 (5) - 28°C *1
AUTO (single set point) 67 - 83°F/19 - 28°C *1
AUTO (dual set point) [COOL] Preset temperature range for COOL mode.
[HEAT] Preset temperature range for HEAT mode. *2, *3
SETBACK [COOL] Preset temperature range for COOL mode.
[HEAT] Preset temperature range for HEAT mode. *3
FAN, VENTI. Unsettable
Fan speed
Vane
ON
FAN
AUTO
FAN
ON
VANE
AUTO Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 Swing
VANE
WT06428X01_GB.fm Page 8 Friday, December 16, 2011 9:51 AM
– 9 –
GB
Controller operation - Function settings
The preset temperature range for each operation mode can be restricted.
1 Press the button to stop the air conditioning unit.
2 Press and hold the button for three seconds or longer to bring up the temperature range
restriction setting display. (A or B appears.)
3 Press the button to select from A through D.
* When the AUTO (single set point) mode is not available on the indoor unit, or when the AUTO
mode is set to OFF in the Mode skip setting, D will not be displayed.
A. No temperature range restriction:
The temperature range restriction will not be executed for all modes.
B. Temperature range restriction for COOL/DRYING mode:
The preset temperature range for COOL/DRYING, AUTO (dual set point), and
SETBACK mode can be changed.
C. Temperature range restriction for HEAT mode:
The preset temperature range for HEAT, AUTO (dual set point), and SETBACK mode
can be changed.
D. Temperature range restriction for AUTO (single set point) mode:
The preset temperature range for AUTO (single set point) mode can be changed.
4 Press the button to switch between the upper limit (Hi) and lower limit (Lo) settings.
Temperature range restriction
OFF
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
(1)
ON/OFF
(3)
MODE
(3)
(3)
(3)
(2)
FAN
(6)
FAN
(4)
FAN
(5)
TEMP. /
(5)
TEMP. /
(5)
TEMP. /
(4)
FAN
(4)
FAN
MODE
MODE
MODE
(Press the button for three seconds or longer.)
(Press the button for three
seconds or longer.)
B. Temperature range restriction for COOL/DRYING mode
D. Temperature range restriction for AUTO (single set point) mode
C. Temperature range restriction for HEAT mode
The air conditioning unit stops.
A. No temperature range
restriction
ON/OFF
FAN
MODE
FAN
WT06428X01_GB.fm Page 9 Friday, December 16, 2011 9:51 AM
– 10 –
GB
5 Press the or button to set upper/lower limit value.
Pressing the and buttons simultaneously can bring up the previous
temperature range of COOL/DRYING, HEAT, and AUTO modes.
The temperature can be adjusted within the preset temperature range of the indoor unit.
Refer to the Indoor unit Instruction Book for details.
6 Press and hold the button for three seconds or longer to complete the setting.
If this action is taken while A is displayed, the temperature range restriction will not be executed.
If this action is taken while one of B through D is displayed, all temperature range restrictions for
COOL/ DRYING, HEAT, and AUTO modes set in B through D will be executed.
If the preset temperature range has not been changed, the restriction will not be executed.
After the temperature range restriction is executed, if the user tries to select a temperature
outside of the range, the preset temperature display will blink.
* The temperature range on this controller (PAC-YT53CRAU) connected to the indoor units that
have the temperature range restriction function can be restricted also from the centralized
controller that has the same function.
This function can lock all buttons.
Locking the operations
While the operation lock is disabled ( icon is unlit.), press and hold the button for three
seconds or longer to enable the Operation lock. (A)
* While the operation lock is enabled, icon is lit. (B)
* If any button is pressed while the operation lock is enabled, icon will blink.
Unlocking the operations
While the operation lock is enabled ( icon is lit.), press and hold the button for three
seconds or longer to disable the Operation lock. (C)
The usability of AUTO and SETBACK modes can be set.
This setting is effective only when the controller is connected to the indoor units that have AUTO and
SETBACK modes.
Operation lock setting
Mode skip setting
TEMP.
TEMP.
TEMP.
TEMP.
FAN
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
A. Operation lock is enabled. B. While the operation lock is enabled. C. Operation lock is disabled.
MODE
MODE
OFF
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
(1)
ON/OFF
(3)
MODE
(4)
(2/5)
TEMP. + TEMP.
ON/OFF
(4)
ON/OFF
(Press the buttons for three
seconds or longer.)
A. AUTO mode
The air conditioning unit stops.
B. SETBACK mode
WT06428X01_GB.fm Page 10 Friday, December 16, 2011 9:51 AM
– 11 –
GB
1 Press the button to stop the air conditioning unit.
2 Press the and buttons simultaneously for three seconds or longer to bring up the
Mode skip settings display. (The current setting will appear.)
3 Press the button to switch between the AUTO and SETBACK mode settings. (Not all
operation modes are available on all models of indoor units. Operation modes that are not available
cannot be selected.)
4 Press the button to select ON or OFF.
ON: Target mode can be selected by pressing the button during operation.
OFF: Target mode cannot be selected by pressing the button during operation.
5 Press the and buttons simultaneously for three seconds or longer to complete
the setting.
1 Press the button to stop the air conditioning unit.
2 Press the and buttons simultaneously for three seconds or longer to change the
backlight brightness. (The factory setting is “bright.”)
* Repeat step 2 above to switch the settings A, B, and C.
* The setting will automatically turn off if step 2 is not performed for a certain period of time.
Backlight brightness setting
ON/OFF
TEMP.
TEMP.
MODE
ON/OFF
MODE
MODE
TEMP.
TEMP.
OFF
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
(1)
ON/OFF
(2)
MODE +
(2)
MODE +
TEMP.
TEMP.
(Press the buttons for three seconds or longer.)
A. Bright
The air conditioning
unit stops.
(Press the buttons for three
seconds or longer.)
B. Dark C. Light off
Auto off without
pressing any buttons.
ON/OFF
MODE
TEMP.
WT06428X01_GB.fm Page 11 Friday, December 16, 2011 9:51 AM
– 12 –
GB
Specifications
This product is designed and intended for use in the residential, commercial,
and light-industrial environment.
Controller specifications
Specifications
Product size 70 (W) × 120 (H) × 14.5 (D) mm (2-3/4 × 4-3/4 × 9/16 [in])
(not including the protruding part)
Net weight 0.1 kg (1/4 lb.)
Rated power supply voltage 12 VDC (supplied from indoor units)
Power consumption 0.3 W
Usage environment Temperature 0 ~ 40ºC (32 ~ 104ºF)
Humidity 30 ~ 90%RH (with no dew condensation)
Material PC + ABS
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
WT06428X01
WT06428X01_GB.fm Page 12 Friday, December 16, 2011 9:51 AM
– 1 –
F
Consignes de sécurité......................................................... 2
Noms et fonctions des parties composant la télécommande
... 4
Interface de la télécommande ......................................... 4
Afficheur .......................................................................... 5
Opérations de base............................................................. 6
Mode de fonctionnement................................................. 6
Température programmée............................................... 7
Vitesse du ventilateur ...................................................... 8
Vanne .............................................................................. 8
Fonctionnement de la télécommande - réglage des fonctions
.. 9
Limitation de la plage de température ............................. 9
Réglage Commande bloquée........................................ 10
Réglage Ignorer mode................................................... 10
Réglage de la luminosité du rétroéclairage ................... 11
Caractéristiques ................................................................ 12
Description des icônes
Les icônes carrées utilisées dans ce manuel fournissent
les informations suivantes.
Indique des réglages modifiables uniquement lorsque
les unités fonctionnent.
Indique des réglages modifiables uniquement lorsque
les unités sont à l'arrêt.
Indique des fonctions qui ne sont pas disponibles
lorsque les boutons sont verrouillés ou le système est
contrôlé de manière centrale.
Avant toute utilisation, lire attentivement les instructions de ce manuel pour utiliser le produit
correctement.
Conservez le pour vous y référer ultérieurement.
Assurez-vous que ce manuel et le manuel d'installation sont bien remis à tout futur utilisateur.
Pour assurer la sécurité et le bon fonctionnement de la télécommande, la télécommande doit être
installée uniquement par du personnel qualifié.
ON
OFF
Système de contrôle CITY MULTI
et climatiseurs Mitsubishi séries M et P
Contrôleur à distance simple MA PAC-YT53CRAU
Manuel d'instructions
WT06428X01_F.fm Page 1 Tuesday, December 27, 2011 12:03 PM
– 2 –
F
Consignes de sécurité
Lisez les consignes de sécurité ci-après avant toute utilisation du contrôleur.
Respectez scrupuleusement ces consignes pour assurer la sécurité.
Après avoir lu ce manuel, remettez-le à l'utilisateur final pour qu'il puisse le consulter en cas de
besoin.
Conservez ce manuel pour pouvoir le consulter en cas de besoin. Ce manuel doit être fourni aux
personnes chargées de réparer ou de déplacer la télécommande. Assurez-vous que le manuel est
bien remis à tout futur utilisateur.
AVERTISSEMENT
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
Signale un risque de blessure grave, voire mortelle en cas de
mauvaise utilisation du PAC-YT53CRAU.
ATTENTION
Signale un risque de blessure grave ou de dommage matériel en cas
de mauvaise utilisation du PAC-YT53CRAU.
Précautions générales
Précautions pour le déplacement ou la réparation la télécommande
N'installez pas l'unité en un endroit où se trouvent de grandes
quantités d'huile, de vapeur, de solvants organiques ou de gaz
corrosifs tels du gaz sulfurique ou encore là où sont
fréquemment utilisés des aérosols ou des solutions acides/
alcalines. Ces substances peuvent affecter les performances
de l'unité ou provoquer la corrosion de certains de ses
composants, ce qui peut donner lieu à des défauts de
fonctionnement, des dégagements de fumée ou même une
électrocution ou un incendie.
Ne lavez pas la télécommande avec de l'eau ou tout autre
liquide afin de prévenir tout risque de court-circuit, de fuite
électrique, d'électrocution, de dysfonctionnement, de fumée
ou d'incendie.
N'utilisez par les commutateurs/touches ou d'autres parties
électriques avec les mains mouillées afin de prévenir tout
risque d'électrocution, de dysfonctionnement, de fumée ou
d'incendie.
Lors de la réalisation d'une stérilisation à l'alcool, aérez pour
dissiper les gaz.
Pour éviter tout risque de blessure ou d'électrocution,
éteignez la télécommande et coupez l'alimentation électrique
avant de la nettoyer, de l'examiner, ou avant toute opération
d'entretien de celle-ci.
Pour éviter tout risque de lésion ou d'électrocution, éteignez la
télécommande et couvrez-la avant de pulvériser un
quelconque produit chimique dans l'environnement de celui-
ci.
En cas d'anomalie (odeur de brûlé, etc.), arrêtez le système,
mettez-le hors tension et contactez immédiatement votre
revendeur. Ne pas interrompre le fonctionnement pourrait
causer une électrocution, un mauvais fonctionnement ou un
incendie.
Installez correctement toutes les protections requises pour
protéger la télécommande contre l'humidité et la poussière.
L'accumulation de poussière et d'eau peut provoquer des
électrocutions, de la fumée ou un incendie.
Pour prévenir tout risque d'endommager la télécommande, ne
pulvérisez pas d'insecticide ou tout autre aérosol inflammable
directement dessus.
Ne touchez pas l'écran tactile, les commutateurs ou les
touches avec un objet pointu ou tranchant afin de prévenir
tout risque d'électrocution ou de dysfonctionnement.
Évitez le contact avec les bords tranchants de certaines
parties afin de prévenir tout risque de blessure et
d'électrocution.
Pour prévenir tout risque de blessure, portez un équipement
de protection lors de toute intervention sur la télécommande.
Consultez votre revendeur pour en savoir plus sur la mise au
rebut appropriée du contrôleur.
Seul un personnel qualifié doit être autorisé à réparer la
télécommande ou à la changer de place.
N'essayez pas de démonter ou de modifier vous-même la
télécommande.
Une installation ou une réparation non conforme peut
entraîner des blessures, une électrocution ou un incendie.
WT06428X01_F.fm Page 2 Tuesday, December 27, 2011 12:03 PM
– 3 –
F
ATTENTION
Précautions supplémentaires
Pour prévenir tout risque de court-circuit, d'électrocution,
d'incendie ou de dysfonctionnement, ne touchez pas le circuit
imprimé avec des outils ou vos mains et ne laissez pas la
poussière s'accumuler dessus.
Pour prévenir tout dommage à l'unité, utilisez des outils
appropriés pour son installation, son inspection ou sa
réparation.
N'utilisez pas de benzène, de diluant ou d'abrasif chimique
pour nettoyer le contrôleur, afin d'éviter de le décolorer.
Pour nettoyer le contrôleur, essuyez-le avec un chiffon doux
imbibé d'un mélange d'eau et d'un détergent doux, rincez les
restes de détergent avec un chiffon humide, puis essuyez
l'eau avec un chiffon sec.
WT06428X01_F.fm Page 3 Tuesday, December 27, 2011 12:03 PM
– 4 –
F
Noms et fonctions des parties composant la télécommande
Interface de la télécommande
Écran LCD rétroéclairé
Bouton TEMP.
(Voir page 7.)
Bouton MODE
(Voir page 6.)
Voyant Marche/Arrêt
Bouton ON/OFF (Marche/Arrêt)
Bouton FAN (Ventilateur)
(Voir page 7.)
Bouton VANE (Vanne)
(Voir page 8.)
* Pour régler les fonctions non disponibles sur ce contrôleur (PAC-YT53CRAU) comme la fonction
Volet, utilisez le contrôleur à distance MA ou le contrôleur centralisé.
Le voyant s'allume en vert lors de la
mise sous tension et clignote
pendant le démarrage et lorsqu'une
erreur se produit.
Appuyer sur ce bouton démarre et
arrête le fonctionnement.
WT06428X01_F.fm Page 4 Tuesday, December 27, 2011 12:03 PM
– 5 –
F
Afficheur
*2 Icône (VÉRIFICATION)
Pour les séries M et P, le voyant d'alimentation clignote et l'adresse du réfrigérant (deux chiffres), le code d'erreur
(deux chiffres) et le numéro de l'unité clignotent lorsqu'une erreur se produit.
Pour le City Multi, le voyant d'alimentation clignote et l'adresse du réfrigérant (trois chiffres) et le code d'erreur
(quatre chiffres) clignotent lorsqu'une erreur se produit.
Vérifiez l'état d'erreur, arrêtez le fonctionnement et consultez votre revendeur.
Lorsque seul le code d'erreur clignote, les climatiseurs restent en marche mais une erreur peut s'être produite.
Vérifiez le code d'erreur et consultez votre revendeur.
[Séries M et P] [City Multi]
[Séries M et P] [City Multi]
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
L'adresse du
réfrigérant et
l'attribut de l'unité
apparaissent
alternativement.
Le code d'erreur et
le numéro de l'unité
apparaissent
alternativement.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
L'adresse de
l'unité clignote.
Le code d'erreur
clignote.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Le code d'erreur
clignote.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Le code d'erreur
clignote.
apparaît lorsque l'unité fonctionne en mode
d'économie d'énergie
* Toutes les icônes sont affichées pour la compréhension.
apparaît lorsque le réglage Commande bloquée
est effectif. (Voir page 10.)
apparaît lorsque les fonctions de l'unité intérieure
sont réglées.
(Veuillez vous référer au manuel d'installation.)
Icône de vitesse du ventilateur
Icône de vanne
apparaît lorsque l'unité est sous tension.
Température intérieure
Modes de fonctionnement
Icône CENTRAL *1
Icône CHECK (VÉRIFICATION) *2
Température programmée *3
*1 Icône
Apparaît lorsque le fonctionnement local suivant est interdit : ON/OFF ; mode de fonctionnement ; température
programmée ; vitesse du ventilateur ; vanne.
CENTRAL
*3 Température programmée
* Vous pouvez sélectionner Centigrade ou Fahrenheit. Consultez le manuel d'installation pour en savoir plus.
En modes FROID, DÉSHU., CHAUD
ou AUTO (un seul point de réglage)
En modes AUTO (deux points de réglage)
ou INVERSION
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Température
programmée
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Température
programmée de
chauffage
Température
programmée de
refroidissement
WT06428X01_F.fm Page 5 Tuesday, December 27, 2011 12:03 PM
– 6 –
F
Opérations de base
Appuyer sur le bouton change le mode de fonctionnement dans l'ordre suivant.
*1: Toutes les fonctions ne sont pas disponibles sur tous les modèles d'unités intérieures.
Les fonctions non disponibles n'apparaissent pas à l'écran.
*2: La température programmée en mode AUTO (un ou deux points de réglage) apparaît en fonction
du modèle d'unité intérieure.
*3: Disponible uniquement sur les unités des séries M et P reliées à l'unité LOSSNAY.
« VENTI. » apparaît lorsque l'unité LOSSNAY fonctionne tandis que l'unité fonctionne.
Mode AUTO (deux points de réglage) :
En mode AUTO (deux points de réglage), les températures programmées peuvent servir au
refroidissement ou au chauffage ; il est possible de basculer le fonctionnement automatiquement
entre le refroidissement et le chauffage en fonction de la température de la pièce.
Les températures programmées pour le refroidissement et le chauffage en mode AUTO (deux
points de réglage) reflètent le réglage de la température des modes FROID/DÉSHU. et CHAUD.
Mode INVERSION :
La fonction de INVERSION change automatiquement le mode de fonctionnement entre
refroidissement et chauffage afin de maintenir la température de la pièce dans la plage de la
température programmée.
Les températures programmées pour le refroidissement et le chauffage en mode INVERSION
peuvent varier des températures programmées pour les autres modes.
Mode de fonctionnement
ON
MODE
COOL
(FROID)
HEAT
(CHAUD)
AUTO
FAN
(VENTILATEUR)
DRYING
(DÉSHU.)
SETBACK
(INVERSION)
VENTI.
(VENTILATION)
*1 *1 *1 *1*1, *2 *1, *3
Pendant le fonctionnement en mode AUTO (deux points de réglage)
Température
programmée
(FROID)
Température
programmée
(CHAUD)
CHAUD FROID
La température de la
pièce change en
fonction de la
température extérieure.
Température
de la pièce
CHAUD FROID
Pendant le fonctionnement en mode INVERSION
Température
de la pièce
La température de la
pièce change en
fonction de la
température extérieure.
Température
programmée
(FROID)
Température
programmée
(CHAUD)
CHAUD CHAUDFROID FROID
WT06428X01_F.fm Page 6 Tuesday, December 27, 2011 12:03 PM
– 7 –
F
En modes FROID, DÉSHU., CHAUD et AUTO (un seul point de réglage)
Appuyer sur le bouton augmente la température programmée.
Appuyer sur le bouton diminue la température programmée.
En modes AUTO (deux points de réglage) et INVERSION
* Pendant le réglage de la température programmée, le réglage est automatiquement désactivé si le
bouton ou n'est pas touché pendant une période prédéterminée.
Température programe
ON
TEMP.
TEMP.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Température programmée de refroidissement
Température programmée de chauffage
Mode de fonctionnement actuel
La température programmée (refroidissement/chauffage) actuelle apparaît.
* L'exemple montre l'affichage en mode AUTO (deux points de réglage).
Lorsque vous appuyez sur le bouton ou , l'affichage de la
température programmée (refroidissement/chauffage) clignote.
TEMP.
TEMP.
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Lorsque l'affichage de la température programmée (refroidissement/chauffage)
clignote, appuyer sur le bouton augmente les températures
programmées de refroidissement et de chauffage et appuyer sur le bouton
diminue les températures programmées de refroidissement et de
chauffage.
Lorsque vous appuyez sur le bouton , seul l'affichage de la température
programmée de refroidissement clignote.
TEMP.
TEMP.
MODE
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Lorsque l'affichage de la température programmée de refroidissement clignote,
appuyer sur le bouton augmente la température programmée de
refroidissement et appuyer sur le bouton diminue la température
programmée de refroidissement.
Lorsque vous appuyez sur le bouton , seul l'affichage de la température
programmée de chauffage clignote.
TEMP.
TEMP.
MODE
Room
Set to
AUTO COOLHEATFAN
DRYING VENTI. SETBACK
Lorsque l'affichage de la température programmée de chauffage clignote,
appuyer sur le bouton augmente la température programmée de
chauffage et appuyer sur le bouton diminue la température
programmée de chauffage.
Appuyer sur le bouton termine le réglage de température programmée.
TEMP.
TEMP.
MODE
TEMP.
TEMP.
WT06428X01_F.fm Page 7 Tuesday, December 27, 2011 12:03 PM
– 8 –
F
La plage de températures programmées se présente comme suit.
*1 La plage de températures programmées varie en fonction du modèle d'unité intérieure à connecter.
Consultez le manuel d'instructions de l'unité intérieure pour en savoir plus.
*2 Les températures programmées pour le refroidissement et le chauffage en mode AUTO (deux points de
réglage) sont utilisées en mode FROID/DÉSHU. et CHAUD.
*3 Les températures programmées pour le refroidissement et le chauffage peuvent être réglées dans les
conditions suivantes.
• La température programmée de refroidissement est supérieure à la température programmée de chauffage.
• La différence entre les températures programmées de refroidissement et de chauffage est égale ou
supérieure à la différence de température minimale qui varie en fonction du modèle d'unité intérieure à
connecter.
Appuyer sur le bouton change la vitesse du ventilateur dans l'ordre suivant.
* La vitesse du ventilateur réglable varie en fonction du modèle d'unité intérieure à connecter.
* Si l'unité ne possède pas de fonction de ventilation, vous ne pouvez pas régler la vitesse du
ventilateur. Le cas échéant, l'icône du ventilateur clignote lorsque vous appuyez sur le bouton .
Appuyer sur le bouton modifie le sens des vannes.
* Le sens des vannes réglable varie en fonction du modèle d'unité intérieure à connecter.
* Si l'unité ne possède pas de fonction de vanne, vous ne pouvez pas régler le sens des vannes.
Le cas échéant, l'icône des vannes clignote lorsque vous appuyez sur le bouton .
Mode de fonctionnement Plage de températures programmées
FROID/DÉSHU. 67 - 87 (95)°F/19 - 30 (35)°C *1
CHAUD 63 (40) - 83°F/17 (5) - 28°C *1
AUTO
(
un seul point de réglage
)
67 - 83°F/19 - 28°C *1
AUTO
(
deux points de réglage
)
[FROID]
Plage de températures programmées du mode FROID
[CHAUD]
Plage de températures programmées du mode CHAUD
*2, *3
INVERSION [FROID]
Plage de températures programmées du mode FROID
[CHAUD]
Plage de températures programmées du mode CHAUD
*3
Ventilateur, Ventilation Non réglable
Vitesse du ventilateur
Vanne
ON
FAN
AUTO
FAN
ON
VANE
AUTO Réglage 1 Réglage 2 Réglage 3 Réglage 4 Réglage 5 Balayage
VANE
WT06428X01_F.fm Page 8 Tuesday, December 27, 2011 12:03 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Mitsubishi Electric PAC-YT53CRAU Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues