Installation Guide
OttoE TF100(H)/TG100(H) Series | Unmanaged Ethernet Switch
Unpacking
Open the carton and unpack the items. Your package should include:
OttoE TF100(H) or TG100(H) series switch. Note that the (H) indicates
hardened models.
If any items are missing or damaged, notify your EtherWAN representative. If
possible, save the carton and packing material in case you need to ship or store the
switch in the future.
What Else You Need
Appropriate cables for data ports. To prevent damage to the switch from
electrical surges, it is recommended to use STP (Shielded twisted pair)
cabling.
Personal computer or laptop
Appropriate SFP modules for SFP ports
Select a Location
Installations: DIN-Rail mount.
Select a power source within 6 feet (1.8 meters).
Choose a dry area with ambient temperature between -10 and 6C (-14
and 140ºF) for OttoE TF100 and TG100.
Choose a dry area with ambient temperature between -40 and 7C (-40 to
167ºF) for OttoE TF100H and TG100H.
For use at altitudes up to 2000 meters, indoor use only.
Humidity range (Operational): 5% to 95%, non-condensation
For use in Pollution Degree 2 environment.
Connect to the Data Ports
Depending on the model, your switch can have the following ports:
TF100(H)-0800
TF100(H)-0602
TG100(H)-0800
TG100(H)-0602
To prevent damage to the switch from electrical surges, it is recommended to use
STP (Shielded twisted pair) cabling.
Connect Power
The switch has two pairs of power inputs. Only one power input is required to
operate the switch. However, redundant power supply functionality is supported.
Power rating:
Model TF100(H)-0800: 9-55 VDC, 0.25-0.05 A
Model TF100(H)-0602: 9-55 VDC, 0.35-0.1 A
Model TG100(H)-0800: 9-55 VDC, 0.5-0.1 A
Model TG100(H)-0602: 9-55 VDC, 0.6-0.15 A
The power input specification complies with the requirements of SELV (Safety
Extra Low Voltage), and the power supply should comply with UL 61010-1 and UL
61010-2-201.
Terminal Block
The switch provides two power inputs on a 9-55 VDC terminal block. The terminal
block has 7 terminal posts.
Pin
Description
Power 1
+
9-55VDC
Power Ground
Power 2
+
9-55VDC
Power Ground
Earth Terminal
Relay Output
Rating
0.5A @30VDC
Relay Output Alarm
The switch provides a relay output contact. The relay is for signaling of a user-
defined power redundancy failure. The current is 0.5A@30VDC at Normal Open
or Normal Close.
POWER1
INPUT
POWER2
INPUT
RELAY contact
X
X
Open, Start alarm
O
X
Open, Start alarm
X
O
Open, Start alarm
O
O
Close, Non-alarm
Power-Up Sequence
When the switch is powered up:
All Link/ACT LEDs blink momentarily.
The Power 1 LED light goes ON.
LEDs for every port connected to a device will flash, as the switch conducts a
brief Power On Self-Test (POST).
Front Panel LEDs
TF100(H)-0800 TF100(H)-0602
TG100(H)-0800 TG100(H)-0602
LED
Color
Status
L/A
(Link/Active)
Green
LED On: Link
LED Off: No Link
LED blinking: Data Transmission
PWR 1&2
Green
LED On: Power On
LED Off: Power Off
Alarm
Red
LED On: Error Power Redundancy Detection
LED Off: No Power Error Condition
W70G-TG-TFQIG6 Page 2
Copyright 2022 EtherWAN Systems, Inc. All Rights Reserved 06/26/2023
Installation Guide
OttoE TF100(H)/TG100(H) Series | Unmanaged Ethernet Switch
Quality of Service (QoS)
The QoS feature is automatically activated when the switch is running. Priority
mapping is handled according to the following tables:
TF100(H)
CoS priority
(802.1p)
7, 6, 5, 4
3, 2, 1, 0
Queues
1
0
WRR
16
1
EtherNet/IP: UDP 2222 (Queue 1)
TG100(H)
CoS priority
(802.1p)
7, 6
5, 4
3, 2
1, 0
DSCP priority
59, 55
47, 46, 43
27
Other
Queues
3
2
1
0
WFQ
Highest
Priority
Secondary
Priority
16
1
EtherNet/IP: UDP 2222 (Queue 2)
Profinet Ether type: 0x8892 (Queue 2)
Other Information
DIN-Rail Assembly Startup, and Dismantling
Assembly: Place the Switch on the DIN rail from above using the slot. Push
the front of the Switch toward the mounting surface until it audibly snaps
into place.
Startup: Connect the supply voltage to start up the Switch via the terminal
block.
Dismantling: Pull out the lower edge and then remove the Switch from the
DIN rail.
User Guide for KC Certification
Power wiring information:
Use copper conductors only.
Use cable type - AWG (American Wire Gauge) 18-22 and corresponding pin type
cable terminals.
The rating of the power wire used must be at least 105°C.
Informations de câblage d'alimentation:
Utilisez le type de câble - AWG (American Wire Gauge) 18-22.
Le calibre du fil d'alimentation utilisé doit être d'au moins 105°C.
DESTINÉ À ÊTRE UTILISÉ AVEC DES CONDUCTEURS EN CUIVRE SEULEMENT.
Si la méthode d'utilisation de l'équipement diffère de celle décrite par le fabricant,
la protection assurée par l'équipement risque d'être altérée.
Contactez-nous pour l'entretien ou la reparation.
Label clean up:
Wipe with a dry cloth to clean up the labelling.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
The product is open type, intended to be installed in an industrial control panel or
an enclosure.
SFP module specification requirement: Class 1 laser product. Complies with CDRH
21CFR 1040.10 and 1040.11. Rated 3.3 or 5 VDC.
The installation safety of any system incorporating the equipment is the
responsibility of the assembler of the system.
Nettoyage de l’étiquette:
Nettoyez avec un chiffon doux et sec.
Si l’équipement est utilisé d’une façon non conforme aux directives du
manufacturier, il peut être endommagé.
Le produit est du type ouvert et doit être installé dans un coffret ou panneau de
contrôles industriel.
Spécification pour le module SFP : Laser classe 1 conforme aux normes CDRH
21CFR 1040.11 Alimentation 3.3 ou 5 VCC.
La sécurité d’une l’installation d’un système incorporant l’équipement est la
responsabilité de l’assembleur du système.
Manufacturer information:
EtherWAN Systems, Inc.
33F, No. 93, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City, 221 Taiwan
The full product manual can be downloaded from:
https://www.etherwan.com/products/ethernet-switches