Zephyr AK7500CS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
WWW.ZEPHYRONLINE.COM
OCT20.0301
Airow Control Technology
TM
C
Tempest II
AK7500CS, AK7536CS, AK7542CS,
AK7548CS, AK7554CS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
2
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
3
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information ............................................................................ 4-9
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................5-8
Operation ........................................................................................... 8
Electrical Requirements .....................................................................8-9
Federal Communication Commission Interface Statement ................. 9
List of Materials .................................................................................. 10
Installation Instructions ....................................................................11-24
Ducting Calculation Sheet .................................................................... 11
Mounting Height, Clearance, & Ducting .......................................... 12-13
Ducting Options .................................................................................14
Hood Specifications ............................................................................15
Electrical Supply .................................................................................16
Cable Lock .........................................................................................16
Mounting the Hood ...........................................................................17-18
Horizontal Ducting Conversion ........................................................ 19-21
PBD-1200A Dual Blower Vertical Ducting .........................................22-23
PBD-1200A Dual Blower Horizontal Ducting ....................................... 24
Features & Controls ......................................................................... 25-29
Touch Controls ................................................................................25-27
Optional RF Remote Control ............................................................28-29
Maintenance ................................................................................... 30-32
Hood & Filter Cleaning .....................................................................30-31
LumiLight LED ................................................................................... 32
ACT™ Conversion ............................................................................ 33-35
Airflow Control Technology (ACT™) ................................................... 33
Enabling ACT™ ................................................................................34-35
Wiring Diagram ............................................................................... 36-37
Troubleshooting............................................................................... 38-39
List of Parts & Accessories ..................................................................40
Notes ................................................................................................41-42
Limited Warranty ...............................................................................43
Product Registration ........................................................................... 44
4
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual for your appliance. Always read
and obey all safety messages.
This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe
bodily injury or death. All safety messages will follow the Safety Alert Symbol and either the words
DANGER” “WARNING” or “CAUTION
DANGER
WARNING
CAUTION
Danger means that failure to heed this safety
statement may result in severe injury or death.
Warning means that failure to heed this safety
statement may result in extensive product damage,
serious personal injury, or death.
Caution means that failure to heed this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
5
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING
General Safety
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
CAUTION
6
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
7
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING
8
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Ź To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
CAUTION
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could
catch onto hair, fingers and loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given
here for installation, maintenance and suitable use of the product. The manufacturer further
declines all responsibility for injury due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility to be aware of these below:
Ź To contact a qualified electrical installer.
Ź To assure that the electrical installation is adequate and in conformance with National Electrical
Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
9
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly
grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire with ground. Please also refer to Electrical Diagram on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements, purchase and install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment o and on, the user is encouraged to try to correct the interference by one
of the following measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
10
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
List of Materials
#6 x 1” (4 )
#6 x 1-1/2” (4 )
#6 x 2” (4 )
M3.5 x 8 (8)
Wire Caps (3)
3/16 x 3/8 (4)
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Dual blower kit (PBD-1200A)
Duct cover accessory
Wood board to hang hood (WxDxH)
AK7500CS: 27” x 1/2” x 4”
AK7536CS: 33” x 1/2” x 4”
AK7542CS: 39” x 1/2” x 4”
AK7548CS: 45” x 1/2” x 4”
AK7554CS: 51” x 1/2” x 4”
Parts Supplied
Quantity Part
1Hood
2 Pro bae filters (AK7500CS, AK7536CS, AK7542CS)
3 Pro bae filters (AK7548CS & AK7554CS)
2 LumiLight LED, 6W (pre-installed)
4 LumiLight LED, 6W (pre-installed) (only AK7548CS & AK7554CS)
1 8” round starting collar
1 Rectangular starting collar (for single horizontal ducting)
1 Top cover plate (for horizontal ducting)
1 Hardware package
11
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Duct pieces
To t a l
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
To t a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Ducting Calculation Sheet
12
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Installation Instructions
Mounting Height, Clearance, & Ducting
24” min.
36” max.
36”
13
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum of 8” round must be used to maintain maximum air flow eciency for single blower and
10” round duct for dual blower for both horizontal and vertical ducting.
A 3-1/4” x 10” rectangular duct may also be used for single blowers for horizontal ducting
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on page 11) to compute total available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 36.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
14
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Installation Instructions
Ducting Options
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Sot or crawl space
Roof Pitch w/
Flashing & Cap
Rear Ducting
Side wall cap
w/ gravity damper
15
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ů
Top View
Side View
Back View
Ducting & Electrical Dimensions
12”
24”
4”
18”
8-9/16”
1-3/4”
1-1/16”
11-9/16”
6”
**7-7/8”
or
***10-3/8”
**9-1/2”
or
***14-3/16”
2-3/4”
**7-7/8”
or
***9-15/16”
R 9/16”
**7-7/8”
or
***10-3/8”
**1-15/16”
or
***4-5/16”
11-9/16”
10-3/4”
*3-3/16”
**7-7/8“
***10-3/8”
*9-7/8”
**9-1/2”
***14-3/16”
**7-7/8”
or
***9-15/16”
* Single Blower Rect. Ducting Dimension
** Single Blower Round Ducting Dimension
*** Dual Blower Dimension
1-11/16”
29-7/8” (30”)
35-7/8” (36”)
41-7/8“ (42”)
47-7/8” (48”)
53-7/8” (54”)
C/L
C/L
Back View
Mounting Dimensions
16-7/8”
16-1/8”
13-5/8”
1-11/16”
3-5/16”
21-1/4”
27-3/8” (36“ & 42”), 35-1/4” (48” & 54”)
5-5/16”
16
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
17
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting the Hood
FIG. B
C/L
C/L
A
B
16-7/8
min
24”
4”
wood board
At least two installers are required due to the
weight and size of the hood.
CAUTION
1. Select preferred ducting application (vertical or
horizontal) and prepare hood. Refer to page 11
for single blower horizontal ducting, page 13 for
dual blower vertical ducting or page 14 for dual
blower horizontal ducting.
2. Plum and mark center line on wall.
3. Choose desired height above cooking surface
(24” min). Level and mark hood bottom, line A
(FIG. B)
4. Level and mark top of wood board, line B (FIG.
B) 16-7/8” from line A.
5. Mark center line of wood board. Center and
align top of board with line B. Secure wood
board to studs using (4) #6 wood screws. Wood
Board Dimensions: (W x D x H)
AK7500CS - 27” x 1/2” x 4”
AK7536CS - 33” x 1/2” x 4”
AK7542CS - 39” x 1/2” x 4”
AK7548CS - 45” x 1/2” x 4”
AK7554CS - 51” x 1/2” x 4”
6. Prepare duct pipe and duct cut outs in upper
cabinet if needed or wall If horizontally ducting
hood. Refer to hood specifications on page 15
for dimensions.
18
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Installation Instructions
Mounting the Hood
7. Prepare electrical wiring and electrical cut outs in upper cabinet if needed or wall if horizontal
electrical hook up is required. Refer to hood specifications on page 15 for dimensions.
8. Mount hood onto wood board and secure using (4) #6 wood screws.
9. Further secure hood onto wall through lower body screw holes by (2) #6 wood screws. See
dimensions in FIG. C.
10. Install electrical.
11. Install duct work and seal with certified aluminum duct tape.
12. Power up hood and check for leaks around duct tape.
13. Install bae filters.
FIG. C
16-7/8”
16-1/8”
13-5/8”
1-11/16”
3-5/16”
21-1/4”
27-3/8” (36“ & 42”), 35-1/4” (48” & 54”)
5-5/16”
19
Tempest II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Horizontal Ducting Conversion
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round
vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following
the instructions below.
C
B
1. Disconnect blower plug.
2. Remove (4) screws from interior
of hood body attaching single
blower plate to top of hood body.
Remove single blower and single
blower plate.
3. Knock out rear plate B for rear
rectangular rear ducting or plate
C for 8 inch round rear ducting.
20
Tempest II Use, Care, and Installation Guide
TEMPEST II
UNDERCABINET
PRO
Installation Instructions
Horizontal Ducting Conversion
4. Remove (4) screws attaching
blower to blower plate. Turn
blower 180 degrees and reattach
to blower plate.
5. Position single blower with single
blower plate as shown. Be sure to
tuck back of single blower plate
into tabs at back of hood. Secure
single blower plate to back of
hood using (4) screws removed
from step 2.
6. Attach 8” round duct collar or
3-1/4” x 10” rectangular duct
collar to back of hood body using
(4) M3.5 x 8 screws.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Zephyr AK7500CS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

dans d''autres langues