Dometic MASTERFLUSH MF7100, MF7200 Le manuel du propriétaire

Catégorie
Articles sanitaires
Taper
Le manuel du propriétaire
MF7100, MF7200
Macerator Toilet
Installation Manual . . . . . . . . . . . . . . . . . . . 4
Zerhackertoilette
Montageanleitung . . . . . . . . . . . . . . . . . . 14
WC dilacérateur
Instructions de montage . . . . . . . . . . . . . 25
Inodoro triturador
Instrucciones de montaje. . . . . . . . . . . . . 36
WC con maceratore
Indicazioni di montaggio. . . . . . . . . . . . . 47
Versnijdingstoilet
Montagehandleiding . . . . . . . . . . . . . . . . 58
Findelingstoilet
Monteringsvejledning . . . . . . . . . . . . . . . 68
Maceratortoalett
Monteringsanvisning . . . . . . . . . . . . . . . . 78
Macerator-toalett
Monteringsanvisning . . . . . . . . . . . . . . . . 88
Silppuripumppu-wc
Asennusohje . . . . . . . . . . . . . . . . . . . . . . . 98
Sanita de trituração
Instruções de montagem. . . . . . . . . . . . 108
Унитаз с мацератором
Инструкция по монтажу . . . . . . . . . . . . 119
Toaleta z rozdrabniaczem
Instrukcja montażu . . . . . . . . . . . . . . . . . 129
Macerátorová toaleta
Návod na montáž . . . . . . . . . . . . . . . . . . 140
Toaleta s maceračním čerpadlem
Návod k montáži . . . . . . . . . . . . . . . . . . 140
Darálós vécé
Szerelési útmutató . . . . . . . . . . . . . . . . . 160
EN
DE
FR
ES
IT
NL
DA
SV
NO
FI
PT
RU
PL
SK
CS
HU
SANITATION
MASTERFLUSH
04_title_I_16s_Invoice.fm Seite 1 Montag, 15. August 2016 7:37 19
04_title_I_16s_Invoice.fm Seite 2 Montag, 15. August 2016 7:37 19
2
1
2
345 6 7
3
Dometic MasterFlush
A
D
E
C
A
B
1
A
B
C
D
E
G
F
3
4
B1-B2
4
2.1 Warnings – marine applications
The following statements must be read and understood before installing, servicing and/or
operating this product on a boat. Modifi cation of this product may result in property damage.
Dometic recommends that a quali ed marine technician or electrician install or service this product.
Equipment damage, injury to personnel or death could result from improper installation. DOMETIC
ACCEPTS NO RESPONSIBILITY OR LIABILITY FOR DAMAGE TO EQUIPMENT, OR INJURY OR
DEATH TO PERSONNEL THAT MAY RESULT FROM IMPROPER INSTALLATION, SERVICE OR
OPERATION OF THIS PRODUCT.
Dometic MasterFlush Notes on using the manual
1 Notes on using the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 – 5
3 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Speci cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 – 7
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 – 13
6 Customer service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1 Notes on using the manual
Note
Supplementary information for operating the device.
g.
1
A, page 2 : This refers to an element in an illustration. In this example, item A in
gure 1 on page 2.
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and
impair the function of the device.
Caution! Hazard of Flooding
If the toilet is connected to ANY through-the-hull  ttings, properly installed seacocks MUST
be installed in all piping connected to through-the-hull  ttings. Seacocks MUST be easily
accessible to all users of the toilet or secondary valves  tted in hoses where they are easily
accessible. All valves MUST be full bore valves and of marine quality. Screw-to-close gate
valves are not recommended. Failure to do so can result in  ooding which can cause loss
of property and life.
EN
Table of contents
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
Faulty assembly or connection
Damage to the unit from mechanical in uences, misuse or abuse
Alterations to the unit without express written permission from the manufacturer
Use for purposes other than those described in the operating manual
Make sure to follow any governing codes or standards that apply to your installation.
5
General safety instructions
Caution! Hazard of Flooding
If toilet uses sea water for  ushing at ANY time, a sea water pump controlled by an auto-
matically operating demand switch MUST NOT be installed. If the onboard water valve or
any plumbing connections were to leak, the automatically operated pump would start and
could  ood the boat. Failure to comply can cause loss of property and life.
Caution! Hazard of Flooding
Before beginning any work on this product, be sure that all electrical power to the unit has
been turned off and that seacocks are in the CLOSED or OFF position. Failure to do so can
result in  ooding which can cause loss of property and life.
Caution!
Do not connect sea water  ush toilet (models 7160, 7180) to an onboard potable water
system. Failure to comply could result in contamination of the potable water supply.
Caution! Hazard of Flooding
Do not connect sea water  ush toilet (models 7160, 7260) to an onboard pressurized water
system. Failure to comply can result in  ooding which can cause loss of property and life.
Caution! Hazard of Shock or Fire
Always use recommended fuse, circuit breaker and wire size. Failure to do so can result in
re that can cause the loss of property and life.
Caution!
Over lling the holding tank can create serious damage to the sanitation system, such
as rupturing the holding tank and releasing tank contents into the bilge. To prevent this
possibility, Dometic recommends using a “full” tank shut-down relay from the “full” signal
generated by an optional Dometic DTM01C tank monitor or DTM04 four-level tank monitor
system.
Caution! Hazard of Flooding
If toilet rim is ever less than 8 in. (20 cm) above the highest possible waterline at ANY time
(during any conditions of heel, load or trim) and is connected to ANY through-the-hull
ttings, properly positioned ventilated (vented) loops MUST be installed in intake* or dis-
charge piping to prevent potential back siphonage of sea water into the boat. Vented loops
must be equipped with integral check valve that permits air into line to prevent siphoning.
Failure to do so can result in  ooding which can cause loss of property and life.
* if connected to sea water
Caution! Hazard of Flooding
If toilet is connected to ANY through-the-hull  ttings, ALL  exible hoses must be of marine
sanitation quality and must be secured to ANY  ttings (such as those at seacock, vented
loop or toilet) with two stainless steel, worm-drive hose band clamps at each connection.
Connections MUST be checked frequently for integrity. Failure to comply can result in
ooding which can cause loss of property and life
.
Dometic MasterFlush
6
Components
Caution!
Discharge of sewage directly overboard is illegal in some areas. Please check all local laws
before operating an overboard discharge sanitation system.
3 Components
Carton contents ( g.
1
)
Toilet components ( g.
2
)
Ref. Description
A Macerator toilet
B1 DFS-2F  ush switch (standard -
freshwater  ush toilet)
B2 DFS-1F  ush switch (standard -
sea water  ush toilet)
C 1.5 in. (38 mm) discharge  tting
D Floor mounting hardware kit
E Water supply hose kit
NS Parts list, installation and operation
instructions, quick-start guide
Ref. Description
1 Rim  ush check valve (freshwater
toilet) or adapter (sea water model)
2 Water supply hose
3 Macerator pump
(under plastic cover)
4 Electric water valve
5 Product ID label location
6 Stainless steel compression band
7 Discharge  tting
Refer to complete parts list (packed separately)
for additional information.
4 Specifi cations
4.1 Dimensions ( g.
3
)
Ref. Dimension
A 13.25 in. / 337 mm
B 14.5 in. / 368 mm
C 18.75 in. / 476 mm
D 12.25 in. / 311 mm - seat height
E 13.75 in. / 349 mm
F 10 in. / 254 mm
G 26.25 in. / 667 mm - seat lid up
Ref. Dimension
A 14.75 in. / 375 mm
B 15 in. / 381 mm
C 19 in. / 483 mm
D 13.75 in. / 349 mm - seat height
E 13.75 in. / 349 mm
F 10 in. / 254 mm
G 28.75 in. / 730 mm - seat lid up
Toilet models 7220, 7260
(compact marine bowl)
Toilet models 7120, 7160
(standard bowl)
All dimensions may vary 0.375 in. (10 mm)
Dometic MasterFlush
7
Specifications
Dometic fl ush switch panel
( g.
4
)
Ref. Dimension
A 3.25 in. / 83 mm
B 1.625 in. / 41 mm
4.3 Minimum System Requirements
4.2 Materials
Toilet: vitreous ceramic
Toilet base: polypropylene
Dometic fl ush switch panel: polystyrene (DFS-1F or DFS-2F);
or powder-coated aluminum (DFST)
Electrical
Power draw 20 amps/12 V DC; 10 amps/24 V DC
Circuit breaker 25 amps/12 V DC; 15 amps/24 V DC
Wiring
12 ga. (up to 25 ft./7.6 m total circuit)
Consult ABYC guidelines for additional information.
Water
Supply
Fitting size
Supply hose ID
0.5 in. NPT – fresh water  ush toilet
0.75 in./19 mm ID – sea water  ush toilet
Flow rate 2.0 gpm/7.6 lpm minimum – fresh water  ush
Discharge
Inside diameter 1.5 in./38 mm or 1 in./25 mm
Horizontal run* 40 ft./12.2 m maximum
Vertical run* 4 ft./1.2 m maximum
* Horizontal and vertical run distances are not cumulative. Check for adequate discharge  ow
if installation nears one of these limits.
Speci cations are subject to change without notice.
Dometic MasterFlush
8
0.75 in./
19 mm
SEACOCK
1 in./ 25 mm
or 1.5 in./38 mm
SEACOCK
0.75 in./
19 mm
SEACOCK
1 in./ 25 mm
or 1.5 in./38 mm
SEACOCK
MAKE LOOP
12 in./305 mm
ABOVE FLOOR
MACERATOR
TOILET
Installation
5 Installation
5.1 Above water line system layouts
Note
Determine whether the water supply to the toilet will be fresh water or sea water, above or below the
vessel’s water line, and then follow the appropriate instructions for the installation.
5
6
VENT
FITTING
0.75 in./ 19 mm ID
SEA WATER LINE
0.75 in./ 19 mm ID
SEA WATER LINE
0.5 in./
13 mm ID
FRESH
WATER
LINE
0.5 in./
13 mm ID
FRESH
WATER
LINE
FROM
FRESH
WATER
SUPPLY
FROM
FRESH
WATER
SUPPLY
CHECK VALVE is needed
to ensure sea water pump
stays primed between uses
CHECK VALVE is needed
to ensure sea water pump
stays primed between uses
Add vented loop here
if holding tank is
below water line.*
1 in./ 25 mm
or 1.5 in./38 mm ID
SANITATION HOSE
VENT
FILTER
HOLDING TANK
(cut-away view)
DISCHARGE
PUMP
DECK
DISCHARGE
WATER LINE
WATER LINE
Toilet with direct overboard
discharge
Toilet with
holding tank
discharge
Caution! Hazard of Flooding
All vented loops should be installed a minimum of 8 in./20 cm above water line at full heel.
*
Dometic MasterFlush
9
HOLDING
TANK
(cut-away
view)
1 in./25 mm or
1.5 in./38 mm ID
SANITATION HOSE
0.75 in./
19 mm
SEACOCK
1 in./ 25 mm
or 1.5 in./38 mm
SEACOCK
FROM
FRESH WATER SUPPLY
FROM
FRESH WATER SUPPLY
0.75 in./
19 mm
SEACOCK
1 in./ 25 mm
or 1.5 in./38 mm
SEACOCK
MACERATOR
TOILET
MACERATOR
TOILET
Installation
5.2 Below water line system layouts
7
8
VENT
FITTING
0.75 in./ 19 mm ID
SEA WATER LINE
0.75 in./ 19 mm ID
SEA WATER LINE
0.75 in./ 19 mm ID
VENTED LOOP *
0.75 in./ 19 mm ID
VENTED LOOP *
0.5 in./ 13 mm ID
FRESH WATER LINE
0.5 in./ 13 mm ID
FRESH WATER LINE
Add vented loop here
if holding tank is
below water line.*
1 in./25 mm or
1.5 in./38 mm ID
VENTED LOOP *
1 in./25 mm or
1.5 in./38 mm ID
VENTED LOOP *
VENT
FILTER
DISCHARGE
PUMP
DECK
DISCHARGE
Toilet with direct overboard
discharge
Toilet with
holding tank
discharge
Caution! Hazard of Flooding
All vented loops should be installed a minimum of 8 in./20 cm above water line at full heel.
*
1 in./ 25 mm
or 1.5 in./38 mm ID
SANITATION HOSE
WATER LINE
WATER LINE
Dometic MasterFlush
10
5.3 Inlet plumbing requirements
For sea water fl ush models:
1. Seacock and inlet water line (not supplied with toilet):
a. 3/4 in. (19 mm) full- ow seacock and 3/4 in. (19 mm) ID  exible hose. Follow seacock
manufacturer’s installation instructions.
b. Make sure inlet seacock is below sea water line at all times, during all conditions of full heel.
c. Make sure all inlet hose connections have no sharp bends or restrictions.
d. Use two stainless steel hose clamps at each connection.
e. Provide hose support every 3 ft. (0.9 m) along inlet hose run to limit movement.
f. Keep hose runs as short as possible. Eliminate sags or low spots that may hinder  ow.
2. Water inlet strainer (not supplied with toilet)
a. 100-mesh strainer is recommended between inlet seacock and sea water  ush toilet.
3. Inlet check valve for above-waterline installations (not supplied with toilet):
a. A check valve should be installed in inlet supply line to assure toilet’s sea water pump stays
primed between ushes.
b. Check valve should be located as close as possible to the inlet seacock (
5
,
6
).
4. Vented loop (not supplied with toilet):
a. If the toilet rim will ever be less than 8 in. (20 cm) above the highest possible waterline at any
point of heel, trim or load, then a 3/4 in. (19 mm) vented loop must be installed in the inlet
hose between the inlet seacock and the toilet (
7
,
8
).
b. Vented loop must be positioned a minimum of 8 in. (20 cm) above highest possible waterline
during all conditions of heel, trim or load.
Warning!
Do not connect sea water fl ush toilet inlet line to a pressurized freshwater system.
This will result in a continuously running freshwater pump, which can possibly over ow
the toilet bowl,  ood the boat, and cause potential loss of property or life.
Warning!
Do not connect sea water fl ush toilet inlet line to an onboard potable water system
in any way. This can cause contamination of the potable water system. If fresh water
is desired, purchase the freshwater- ush version of the toilet, or provide a separate
freshwater tank that supplies water only to the toilet.
For freshwater fl ush models:
1. Inlet water line (not supplied with toilet):
a. 0.5 in. (13 mm) ID  exible hose with 1/2 in. NPT  tting connects to toilet water valve.
2. Shut-off valve in inlet line (not supplied with toilet):
a. For toilet cleaning and maintenance.
Installation
Dometic MasterFlush
11
Installation
5.4 Outlet plumbing requirements
For sea water fl ush models:
1. Seacock and outlet sanitation hose (not supplied):
a. 1 in. (25 mm) or 1.5 in. (38 mm) full- ow seacock and  exible
hose to route waste to a holding tank with discharge pump,
or route directly overboard. Follow seacock manufacturer’s
instructions.
b. Make sure waste outlet seacock is both aft and higher than
the water inlet seacock.
c Outlet plumbing should have no sharp bends or restrictions.
d. Use two stainless steel hose clamps at each connection.
e. Provide support along entire hose run to limit movement and
side-loading on connections.
f. Keep hose runs as short as possible. Eliminate sags or low
spots that may hinder  ow.
2. Discharge hose loop near toilet (not supplied with toilet):
a. To retain water in toilet bowl, make a 12 in. (30 cm) high loop
in discharge line as near to toilet as possible
( gs.
5
,
6
).
3. Vented loop (not supplied with toilet):
a. Refer to toilet system layout  gures
6
and
7
8
for
recommended locations of discharge vented loops connect-
ed to system components that are below the water line or
may be less than 8 in. (20 cm) above highest possible water
line at full heel.
b. Vented loops must be positioned a minimum of 8 in. (20 cm)
above highest possible water line at full heel.
5.5 Toilet and fl ush switch installation
1. Carefully unpack toilet, water supply hose, discharge  tting
and hardware ( g.
1
).
2. Place toilet in desired location on  oor. If necessary, rotate
toilet so that macerator pump housing ( g.
2
3) does not
interfere with walls, or so that it will better accommodate the
intended plumbing layout. Con rm adequate clearance is
available for plumbing connections, and also the seat and lid
in raised position. Mark  oor where toilet will be installed.
3. (Optional) If macerator pump and base must be positioned at
an angle so that toilet bowl does not face in correct direction,
the upper bowl can be rotated to the proper position:
a. Loosen compression band (
9
) just enough to slip down
past lower plastic clamp, and remove upper and lower
plastic clamps (
10
).
b. Lift bowl. Make sure notch in black rubber gasket sits around shallow pin on toilet base and
remains centered between bowl and base (
11
). Rotate bowl to desired position, then set it
down on gasket.
c. Re-position plastic clamps and compression band between upper bowl and base. Join
clamps together at front of toilet bowl (there will be a space between the clamps behind the
bowl). With compression band screw positioned on a clamp (not in gap between clamps)
(
9
), tighten compression band to 65 in.-lbs.
9
12
13
10
11
Dometic MasterFlush
12
Installation
4. Connect water supply hose between check valve or adapter
( g.
2
1) and water valve (freshwater  ush model) or water
pump (sea water  ush model) on base.
a. Cut supply hose to length that will not kink when connected.
b. Remove plastic cover ( g.
2
3) from pump.
c. With hose clamp, attach hose to water valve (freshwater
model) or pump (sea water model) barbed  tting (
12
).
d. Place loose end of supply hose up through hole of plastic
cover. Lower and  t cover to macerator pump.
e. Connect water supply hose to rim  ush check valve with
hose clamp (
13
).
5. Plan electrical, water supply and discharge plumbing accord-
ing to appropriate toilet system layout (see pages 8 – 9). Cre-
ate access holes for plumbing and electrical supplies to toilet.
6. Place toilet in  nal location, and fasten it to  oor with hex
head fasteners and washers at sides and rear of base (
14
).
7. Plan ush switch location so that electrical connections and
wires cannot get wet.
8. Use switch template (packed separately) to mark location of
fasteners and switch access hole. Cut out access hole (
15
).
Note
Refer to wiring diagram on reverse side of toilet parts list.
9. WITH ELECTRICAL POWER OFF, route stranded copper
positive wire (gauge per ABYC standards) from circuit break-
er or fuse to switch access hole.* Route red wire from toilet’s
macerator pump to switch access hole. Route wire from
switch access hole to electric water valve at bottom of toilet
(freshwater model). Connect wires according to diagram with
appropriate spade connectors (
15
,
17
).
10. Attach ush switch to wall with screws provided.
11. Connect ground wires from macerator pump and electric
water valve (freshwater models only) to vessel’s electrical
ground wiring according to the wiring diagram. Provide extra
wire at toilet to easily remove from  oor in case of service.
12. Route vessel’s water supply and discharge plumbing to toilet
(refer to toilet system layout  gures on pages 8 – 9).
13. Securely connect all discharge hoses with two stainless steel
hose clamps with screws positioned 180° opposite each
other (
16
). Lubricate  ttings and hoses with silicone grease
to make hose connection easier. For freshwater toilet, con-
nect water supply with 0.5 in. NPT  tting (
17
).
14. For sea water  ush model, open water supply and discharge
seacocks. For freshwater model, turn on water supply.
Check for water leaks at all connections. Turn on electrical
power to toilet, press “Flush” switch and check for leaks. If
leak occurs, tighten connection.
15. Attach plastic covers to  oor mounting fasteners.
* If toilet system includes any DTM series tank monitor system, refer to
Section 5.6.
14
17
15
16
18
Dometic MasterFlush
13
There is a strong, worldwide network to assist
in servicing and maintaining your sanitation
system. For the Authorized Service Center near
you, please call from 8:00 a.m. to 5:00 p.m.
(ET) Monday through Friday.
You may also contact or have your local
dealer contact the Parts Distributor nearest
you for quick response to your replacement
parts needs. They carry a complete inventory
for the Dometic sanitation product line.
Telephone: 1 800-321-9886 U.S.A. and Canada
330-439-5550 International
Fax: 330-496-3097 U.S.A. and Canada
330-439-5567 International
Web site: http://www.Dometic.com
6 Customer service
Installation
5.6 Toilet system with tank monitor and shut-down relay installation
Dometic MasterFlush toilets operate with Dometic DTM tank monitor systems (available separately)
to shut down electrical power to the toilet when the holding tank is full. This prevents over lling the
holding tank. Refer to toilet system wiring diagram on parts list.
1. Route input power wire from “full tank” relay of DTM panel to toilet’s  ush switch location.
2. Follow ush switch installation instructions beginning at Section 5.5, step 10.
DOMETIC CORPORATION
SANITATION DIVISION
13128 SR 226 | PO BOX 38
BIG PRAIRIE, OHIO 44611 USA
www.Dometic.com
© 2014 Dometic Corporation
All rights reserved
600347006 11/13
Caution
Do not operate toilet without water supply turned on. Damage to internal components
may occur.
Dometic MasterFlush
14
2.1 Warnungen – Einsatz auf Booten
Vor Installation, Wartung und Einsatz auf einem Boot müssen die folgenden Anweisungen gelesen
und verstanden werden. Werden Änderungen an diesem Produkt vorgenommen, kann dies zu Sach-
schäden führen.
Dometic emp ehlt, die Installation und Wartung dieses Produkts von einem quali zierten Schiffstechniker
oder Elektriker vornehmen zu lassen. Eine unsachgemäße Installation kann zu Sachschäden, Verletzungen
oder zum Tod führen. DOMETIC ÜBERNIMMT KEINERLEI VERANTWORTUNG ODER HAFTUNG FÜR
SACHSCHÄDEN SOWIE VERLETZUNGEN ODER DEN TOD VON PERSONEN INFOLGE EINER UNSACH-
GEMÄSSEN INSTALLATION, WARTUNG ODER NUTZUNG DIESES PRODUKTS.
Dometic MasterFlush Hinweise zur Benutzung der Anleitung
1 Hinweise zum Verwenden der Anleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Allgemeine Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 – 16
3 Systembauteile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4 Spezi kationen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 – 17
5 Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 – 22
6 Kundendienst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1 Hinweise zum Verwenden der Anleitung
Hinweis
Ergänzende Informationen zur Bedienung des Gerätes.
Abb.
1
A, Seite 2 : Bezeichnet ein Element in einer Abbildung. In diesem Beispiel
Element A in Abbildung 1 auf Seite 2.
Achtung!
Sicherheitshinweis: Nichtbeachtung kann zu Materialschäden führen und die Funktion des
Gerätes beeinträchtigen.
Achtung! Gefahr von Wassereinbrüchen
Wenn die Toilette über IRGENDWELCHE Borddurchlässe angeschlossen ist, müssen in alle
Rohrleitungen, die mit Borddurchlässen verbunden sind, Seeventile eingebaut werden. Die
Seeventile MÜSSEN für alle Benutzer der Toilette leicht zugänglich sein, oder es müssen leicht
zugängliche Zweitventile mit entsprechenden Verbindungsschläuchen installiert werden. Bei
allen Ventilen muss es sich um seewasserfeste Ventile mit voller Bohrung handeln. Schieberven-
tile mit Schraubverschluss werden nicht empfohlen. Andernfalls kann es zu Wassereinbrüchen
kommen, wobei die Gefahr von Unfällen mit Todesfolge oder Sachschäden besteht.
DE
Inhalt
2 Allgemeine Sicherheitshinweise
Der Hersteller übernimmt keine Haftung für Schäden aufgrund von:
Montage- oder Anschlussfehlern
Schäden am Gerät durch mechanische Einwirkung sowie unsachgemäße oder falsche Benutzung
• Modi kationen am Gerät ohne ausdrückliche Genehmigung des Herstellers
Verwendung für andere als die in der Anleitung beschriebenen Zwecke.
Vergewissern Sie sich, dass Sie bei der Montage alle geltenden Vorschriften und Normen befolgen.
15
Grundlegende Sicherheitshinweise
Achtung! Gefahr von Wassereinbrüchen
Wenn JEMALS Seewasser zum Spülen der Toilette verwendet wird, DARF KEINE Seewas-
serpumpe installiert werden, die durch einen automatischen, bei Bedarf aktivierten Schalter
gesteuert wird. Im Fall eines Lecks des an Bord be ndlichen Wasserventils oder einer Leitungs-
verbindung würde die automatisch gesteuerte Pumpe starten und könnte das Boot über uten.
Andernfalls besteht die Gefahr von Unfällen mit Todesfolge oder Sachschäden.
Achtung! Gefahr von Wassereinbrüchen
Stellen Sie vor den Arbeiten an diesem Produkt sicher, dass die Stromversorgung der Toilette
abgeschaltet ist und die Seeventile in der Stellung GESCHLOSSEN bzw. AUS stehen. Andern-
falls kann es zu Wassereinbrüchen kommen, wobei die Gefahr von Unfällen mit Todesfolge oder
Sachschäden besteht.
Achtung!
Schließen Sie keine Toiletten mit Seewasserspülung (Modelle 7160, 7180) an Trinkwassersyste-
me an. Andernfalls kann der Trinkwasservorrat kontaminiert werden.
Achtung! Gefahr von Wassereinbrüchen
Schließen Sie keine Toiletten mit Seewasserspülung (Modelle 7160, 7260) an Wassersysteme
mit Außenborddruck an. Andernfalls kann es zu Wassereinbrüchen kommen, wobei die Gefahr
von Unfällen mit Todesfolge oder Sachschäden besteht.
Achtung! Kurzschluss- und Brandgefahr
Verwenden Sie immer eine Sicherung, einen Schutzschalter und Leitungen der vorgeschriebe-
nen Größe. Andernfalls besteht die Gefahr von Unfällen mit Todesfolge oder Sachschäden.
Achtung!
Das Überfüllen des Schmutzwassertanks kann gravierende Schäden an der Sanitäranlage nach
sich ziehen, wie z.B. einen Bruch des Tanks, wodurch dessen Inhalt in die Bilge  ießen könnte.
Um diese Möglichkeit auszuschließen, emp ehlt Dometic die Verwendung eines Absperrrelais
für den Zustand „Tank voll“, dessen Signal von einer Tanküberwachung DTM01C von Dometic
oder einer vierstu gen Tanküberwachung DTM04 erzeugt wird.
Achtung! Gefahr von Wassereinbrüchen
Wenn sich der Rand der Toilette JEMALS weniger als 20cm (8in) oberhalb der höchstmögli-
chen Wasserlinie be ndet (bei Krängung, Beladung oder Trimmen) und über IRGENDWELCHE
Borddurchlässe angeschlossen ist, MÜSSEN in die Einlass*- oder Auslassleitung ordnungsge-
mäß angebrachte Entlüftungsbögen installiert werden, um einen Rück uss des Seewassers in
das Boot zu verhindern. Entlüftungsbögen müssen mit integrierten Rücklaufventilen versehen
werden, welches Luft in die Leitung lässt, um den Wasserrück uss zu verhindern. Andernfalls
kann es zu Wassereinbrüchen kommen, wobei die Gefahr von Unfällen mit Todesfolge oder
Sachschäden besteht.
* Wenn eine Verbindung zum Seewasser besteht.
Achtung! Gefahr von Wassereinbrüchen
Wenn die Toilette über IRGENDWELCHE Borddurchlässe angeschlossen ist, müssen ALLE
Schläuche seefest und für Sanitäranlagen geeignet und an ALLEN Anschlüssen (z.B. am See-
ventil, am Entlüftungsbogen und an der Toilette) mit zwei Edelstahlschellen mit Schneckenge-
winde befestigt sein. Die Verbindungen MÜSSEN regelmäßig auf ihre Unversehrtheit überprüft
werden. Andernfalls kann es zu Wassereinbrüchen kommen, wobei die Gefahr von Unfällen mit
Todesfolge oder Sachschäden besteht
.
Dometic MasterFlush
16
Komponenten
Achtung!
Die direkte Verklappung von Abwässern ist in manchen Jurisdiktionen untersagt. Bitte
vergewissern Sie sich beim Betrieb einer Sanitäranlage mit Bordauslass, dass Sie alle örtlich
geltenden Gesetze einhalten.
3 Systembauteile
Inhalte des Kartons (Abb.
1
)
Bauteile der Toilette (Abb.
2
, Seite2)
Ref. Beschreibung
A Zerhackertoilette
B1 Spülschalter DFS-2F (Standard–
Toiletten mit Frischwasserspülung)
B2 Spülschalter DFS-2F (Standard–
Toiletten mit Seewasserspülung)
C Entlüftungsverschraubung,
38mm/1,5in
D Montagesatz für die Fußbodenbe-
festigung
E Wasserzuleitungsschlauch, Satz
NS Teileliste, Montage und Betriebsanlei-
tung, Schnellstartanleitung
Ref. Beschreibung
1 Rückschlagventil Randspülung
(Toilette mit Frischwasserspülung)
oder Adapter (Seewasser-Modell)
2 Wasserzuleitungsschlauch
3 Zerhackerpumpe
(unter Kunststoffab-
deckung)
4 Elektrisches Wasserventil
5 Anbringungsort für Aufkleber mit
Produkt-ID
6 Quetschverschraubung aus rostfreiem
Stahl
7 Ab ussanschluss
Weitere Informationen  nden Sie in der vollständi-
gen Stückliste (separat verpackt).
4 Spezifi kationen
4.1 Abmessungen (Abb.
3
)
Ref. Abmessungen
A 337 mm / 13,25 in
B 368 mm / 14,5 in
C 476 mm / 18,75 in
D 311 mm / 12,25 in – Sitzhöhe
E 349 mm / 13,75 in
F 254 mm / 10 in
G 667 mm / 26.25 in –
bei geöffnetem Deckel
Ref. Abmessungen
A 375 mm / 14,75 in
B 381 mm / 15 in
C 483 mm / 19 in
D 349 mm / 13,75 in – Sitzhöhe
E 349 mm / 13,75 in
F 254 mm / 10 in
G 730 mm / 28.75 in –
bei geöffnetem Deckel
Toilettenmodelle 7220, 7260
(Kompakt-Schüssel für den Bootseinbau)
Toilettenmodelle 7120, 7160
(Standard-Schüssel)
Alle Abmessungen können variieren (um +/-10mm / 0,375in).
Dometic MasterFlush
17
Spezi kationen
Spülschalter-Panel von Dometic
(Abb.
4
)
Ref. Abmessungen
A 83 mm / 3,25 in
B 41 mm / 1,625 in
4.3 Mindest-Systemanforderungen
4.2 Material
Toilette: Glaskeramik
Toilettensockel: Polypropylen
Spülschalter-Panel von Dometic: Polystyren (DFS-1F und
DFS-2F) oder pulverbeschichtetes Aluminium (DFST)
Elektrik
Stromaufnahme 20A/12V GS; 10A/24V GS
Schutzschalter 25 A / 12 V GS; 15 A / 24 V GS
Verdrahtung
AWG 12 (max. 7,6m/25ft Gesamtkabellänge im
Stromkreis)
Siehe ABYC-Richtlinien für weitere Informationen.
Wasser-
versor-
gung
Passender
Versorgungsschlauch,
ID
0,5in NPT – Frischwasserspülung
19mm/0,75in ID – Seewasserspülung
Durch uss min. 7,6l/min/2,0gal/min – Frischwasserspülung
Abfl uss
Innendurchmesser min. 38mm/1,5in oder 25mm/1in
Horizontale
Förderdistanz*
max. 12,2 m/40 ft
Vertikale
Förderdistanz*
max. 1,2m/4ft
* Die horizontalen und vertikalen Förderdistanzen sind nicht kumulativ. Stellen Sie einen ausreichenden
Durch uss sicher, falls sich Ihre Montage diesen Grenzwerten nähert.
Änderungen an den Spezi kationen ohne Ankündigung vorbehalten.
Dometic MasterFlush
18
19mm/
0,75in
SEEVENTIL
25mm/1in
oder 38 mm/1,5 in
SEEVENTIL
19mm/0,75in
SEEVENTIL
25mm/1in
oder 38 mm/1,5 in
SEEVENTIL
BOGEN
EINBAUEN,
305mm/12in
ÜBER DECK-
HÖHE
ZERHACKER-
TOILETTE
Montage
5 Montage
5.1 Konstruktionen oberhalb der Wasserlinie
Hinweis
Entscheiden Sie, ob die Toilette mit einer Frischwasser- oder einer Seewasser-Versorgung über oder unter der
Wasserlinie ausgestattet werden soll. Befolgen Sie anschließend die entsprechenden Montageanweisungen.
5
6
ENTLÜFTUNGSVER-
SCHRAUBUNG
0,75 in/19 mm)
Innendurchm.
SEEWASSERLEITUNG
0,75 in/19 mm)
Innendurchm.
SEEWASSERLEITUNG
FRISCHWAS-
SERLEITUNG
0,5in/13mm)
Innendurchm.
FRISCHWAS-
SERLEITUNG
0,5in/13mm)
Innendurchm.
VOM
FRISCHWAS-
SERZULAUF
VOM
FRISCHWAS-
SERZULAUF
RÜCKSCHLAGVENTIL – zur
Sicherstellung der Vorfüllung der
Seewasserpumpe während der
Betriebspausen
RÜCKSCHLAGVENTIL – zur
Sicherstellung der Vorfüllung der
Seewasserpumpe während der
Betriebspausen
Hier Entlüftungsbogen
einbauen, falls sich der
Schmutzwassertank
unterhalb der Wasser-
linie befi ndet.
25mm/1in
oder 38mm/1,5in Innendurchm.
ABWASSERSCHLAUCH
ENTLÜFTUNGS-
FILTER
ABWASSERTANK
(im Schnitt)
AUSLAS-
SPUMPE
DECK-
AUSLASS
WASSERLINIE
WASSERLINIE
Toilette mit direktem Bordauslass
Toilette mit
Auslass in einen
Schmutzwas-
sertank
Achtung! Gefahr von Wassereinbrüchen
Alle Entlüftungsbogen müssen mindestens 20cm/8in oberhalb der bei maximaler Krängung
auftretenden Wasserlinie eingebaut werden.
*
Dometic MasterFlush
19
ABWAS-
SERTANK
(im
Schnitt)
25mm/1in oder 38mm/
1,5in Innendurchm.
ABWASSERSCHLAUCH
19mm/
0,75in
SEEVENTIL
25mm/1in
oder 38 mm/1,5 in
SEEVENTIL
VOM
FRISCHWASSERZULAUF
VOM
FRISCHWASSERZULAUF
19mm/0,75in
SEEVENTIL
25mm/1in
oder 38 mm/1,5 in
SEEVENTIL
ZERHACKER-
TOILETTE
ZERHACKER-
TOILETTE
Montage
5.2 Konstruktionen unterhalb der Wasserlinie
7
8
ENTLÜFTUNGS-
VERSCHRAUBUNG
0,75 in/19 mm)
Innendurchm.
SEEWASSERLEITUNG
0,75 in/19 mm)
Innendurchm.
SEEWASSERLEITUNG
19mm/0,75in Innen-
durchm.
ENTLÜFTUNGSBOGEN *
19mm/0,75in Innen-
durchm.
ENTLÜFTUNGSBOGEN *
0,5in/13mm)
Innendurchm.
FRISCHWASSERLEI-
TUNG
0,5in/13mm Innen-
durchm.
FRISCHWASSERLEI-
TUNG
Hier Entlüftungsbo-
gen einbauen,
falls sich der
Schmutzwassertank
unterhalb der Was-
serlinie befi ndet.
25mm/1in oder 38mm/1,5in
Innendurchm.
ENTLÜFTUNGSBOGEN *
25mm/1in oder 38mm/1,5in
Innendurchm.
ENTLÜFTUNGSBOGEN *
ENTLÜFTUNGS-
FILTER
AUSLAS-
SPUMPE
DECK-
AUSLASS
Toilette mit direktem Bordauslass
Toilette mit
Auslass in einen
Schmutzwasser-
tank
Achtung! Gefahr von Wassereinbrüchen
Alle Entlüftungsbogen müssen mindestens 20cm/8in oberhalb der bei maximaler Krängung
auftretenden Wasserlinie eingebaut werden.
*
25mm/1in oder 38mm/1,5in
Innendurchm.
ABWASSERSCHLAUCH
WASSERLINIE
WASSERLINIE
Dometic MasterFlush
20
5.3 Anforderungen für die Montage der Einlassleitungen
Für Modelle mit Seewasserspülung
1. Seeventil und Einlass-Wasserleitung (nicht im Lieferumfang der Toilette enthalten):
a. Seeventil (ganz zu öffnen), 19mm/0,75in und  exibler Schlauch, 19mm/0,75in. Befolgen Sie die
Montageanleitung des Herstellers des Seeventils.
b. Vergewissern Sie sich, dass das Einlass-Seeventil sich zu jeder Zeit (bei voller Krängung) unterhalb
der Wasserlinie be ndet.
c. Vergewissern Sie sich, dass alle Anschlüsse der Einlassschläuche keine scharfen Biegungen oder
Durch uss-Beeinträchtigungen aufweist.
d. Verwenden Sie bei jeder Verbindung doppelte Schlauchschellen aus Stahl.
e. Stützen Sie den Einlassschlauch alle 0,9m/3ft ab, um übermäßige Bewegungen zu verhindern.
f. Halten Sie die Länge der Schläuche so kurz wie möglich. Vermeiden Sie Durchhängen und niedrig
hängende Abschnitte, die sich negativ auf den Durch uss auswirken können.
2. Filtersieb für Wassereinlass (nicht im Lieferumfang der Toilette enthalten)
a. Es wird empfohlen, zwischen Einlass-Seeventil und Toilette mit Meerwasserspülung ein Filtersieb
mit einer Mesh-Größe von 100 einzubauen.
3. Einlass-Rückschlagventil für Montagen oberhalb der Wasserlinie (nicht im Lieferumfang der Toilette
enthalten)
a. Es wird empfohlen, die Einlassleitung mit einem Rückschlagventil zu versehen, damit die Meerwas-
serpumpe zwischen den Spülgängen vorgefüllt bleibt.
b. Das Rückschlagventil sollte so dicht wie möglich am Einlass-Seeventil eingebaut werden
(
5
,
6
).
4. Entlüftungsbogen (nicht im Lieferumfang der Toilette enthalten)
a. Falls sich der Rand der Toilette jemals weniger als 20cm/8in oberhalb der höchstmöglichen Was-
serlinie (unabhängig von Krängung, Trimm und Last) be ndet, muss der Einlassschlauch zwischen
Einlass-Seeventil und Toilette mit einem Entlüftungsbogen von 19mm/0,75in versehen werden
(
7
,
8
).
b. Der Entlüftungsbogen muss mindestens 20cm/8in oberhalb der höchstmöglichen Wasserlinie
(unabhängig von Krängung, Trimm und Last) eingebaut werden.
Warnung!
Schließen Sie die Einlassleitung einer Toilette mit Meerwasserspülung nicht an ein
druckbeaufschlagtes Frischwassersystem an. Dadurch wird die Frischwasserpumpe kon-
stant in Betrieb gehalten, wodurch die Toilettenschüssel überlaufen kann. Dadurch kann
das Boot ge utet werden – mit potentiellen Personen- oder Sachschäden.
Warnung!
Schließen Sie die Einlassleitung einer Toilette mit Meerwasserspülung nicht an ein
bordeigenes Trinkwassersystem an. Dadurch kann das Trinkwassersystem kontaminiert
werden. Wird eine Spülung mit Frischwasser gewünscht, erwerben Sie bitte die Toiletten-
version mit Frischwasserspülung oder bauen Sie einen separaten Frischwassertank ein,
der ausschließlich der Versorgung der Toilette dient.
Für Modelle mit Frischwasser-Spülung:
1. Einlass-Wasserleitung (nicht im Lieferumfang der Toilette enthalten):
a. Das Wasserventil der Toilette wird mithilfe einer Verschraubung (0,5in NPT) und einen Schlauch
(13mm/0,5inInnendurchmesser) angeschlossen.
2. Absperrventil in der Einlassleitung (nicht im Lieferumfang der Toilette enthalten):
a. Zur Wartung und Reinigung der Toilette.
Montage
Dometic MasterFlush
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172

Dometic MASTERFLUSH MF7100, MF7200 Le manuel du propriétaire

Catégorie
Articles sanitaires
Taper
Le manuel du propriétaire