Braun BD 3005 Manuel utilisateur

Catégorie
Épilation légère
Taper
Manuel utilisateur
www.braun.com
BD 3001
BD 3005
BD 3006
Silk
expert 3
Type 6030
6030
91603863/I-18
91603863_BD3001_3006_AP-ANZ_HK_S1.indd 191603863_BD3001_3006_AP-ANZ_HK_S1.indd 1 18.01.18 13:0118.01.18 13:01
Stapled booklet, 148 x 210 mm, 38 pages (incl. 6 pages cover),
Cover 4/4c, Content 2/2c = PANTONE Medium Purple U + black
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 1 of 38
English 4
Français 14
29
30
Braun GmbH
Frankfurter Straße 145
61476 Kronberg/Germany
www.braun.com
www.service.braun.com
UK/FR/Arab/HK
Braun Infolines
UK 0800 783 7010
IE 1 800 509 448
FR 0 800 944 802
(service & appel gratuits)
HK 2926 2300
(Jebsen Consumer Service Centre)
91603863_BD3001_3006_AP-ANZ_HK_S2.indd 291603863_BD3001_3006_AP-ANZ_HK_S2.indd 2 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 2 of 38
7
8
7a
I II III IV V VI
Skin
Tone
Hair
Colour
Skin tone & Body hair type chart:
==
5
3
2
6
1
4
9
10
suitable / approprié /
ﻢﺋﻼﻣ
/
not suitable / non approprié /
ﻢﺋﻼﻣ ﺮﻴﻏ /
ӧ晒አ
晒አ
91603863_BD3001_3006_AP-ANZ_HK_S3.indd 391603863_BD3001_3006_AP-ANZ_HK_S3.indd 3 18.01.18 13:0018.01.18 13:00
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 3 of 38
4
English
Our products are designed to meet the highest standards of quality, functionality and design.
Using professional light technology, Braun Silk·expert Intense Pulsed Light (IPL) allows you to permanently
remove unwanted, visible hair comfortably at home. Before using the device, please read the use instructions
carefully, including all contraindications, warnings and safety information, and keep them for future reference.
This device has been designed to effect long-term hair growth reduction after a certain period of
treatment. Ideal body areas for use include:
Women: Legs, arms, underarms, bikini area and face (below cheek bones)
CAUTION: Do not use the device near the eyes and along the forehead.
Men: Shoulders and below (chest, back, arms, stomach, legs)
CAUTION: Do not use on the face, neck or genital area.
Usage on male beards or facial hair may lead to permanent or uneven results which may
produce changes in facial characteristics that may not be desirable.
Braun Silk·expert is not suitable for everyone. It is most effective on light to medium skin tones and dark hair
colors. Please, refer to the skin tone and hair color chart on page 3 to see if the device is suitable for you.
Description
1 Treatment window
2 SensoAdapt™ skin tone sensors
3 LED Power bars
4 Gentle mode button and indicator
5 Treatment button
6 Socket
7 Power supply with pin release button (7a)
8 Pin insert
9 Treatment window reflector
10 Glass filter
How does it work?
Braun Silk·expert works beneath the skin surface by targeting the melanin in the hair follicle, helping to
break the cycle of hair re-growth. With continued, periodic use, the light energy helps prevent unwanted
hair from reaching the skin surface.
The intelligent SensoAdapt™ skin sensors (2) continuously read your skin tone before every flash,
automatically adapting the light intensity for best efficacy and safety. This allows treatment of appropriate
skin tones, but prevents treatment if your skin tone is too dark.
CONTRAINDICATIONS
DO NOT USE the device …
if your skin is darker than skin tone V shown on the skin tone chart on page 3.
Since dark skin absorbs more light energy, treating very dark skin may cause
discomfort/pain and adverse effects (e.g., burns, blisters, discoloration or
scarring) and injure your skin.
if you are pregnant, lactating, or under the age of 18 as this device has not been
tested with these individuals.
if you have a history of skin cancer or precancerous lesions (e.g., nevi or a large
number of moles).
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 491603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 4 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 4 of 38
5
If your skin has been artificially or naturally tanned recently. Your skin may be
extra sensitive following sun exposure and particularly susceptible to side effects
of IPL treatment (e.g. burn, blister, discolour or scar to your skin). Also, avoid
unprotected exposure to direct sunlight after your IPL treatment. Your skin may
be extra sensitive and particularly susceptible to sunburn.
Certain conditions can also prohibit the use of this device.
DO NOT USE the device if any of the following applies:
You have a chronic medical condition.
You have a chronic skin disease (e.g. psoriasis or vitiligo) or damaged skin (e.g.
sunburn, cuts, open wounds or active infections) in the areas you wish to treat.
You have varicose veins in the area you wish to treat.
You have a known sensitivity to sunlight (photosensitivity) or are taking
medication that may make the skin more sensitive (e.g. Retin A, Accutane and/or
other topical retinoids).
You have had a skin peel treatment on the area you wish to treat.
You have any of the above, this device may injure your skin or make existing
conditions worse. You may experience side effects such as burns, blisters and
skin color changes (hyper- or hypo-pigmentation) or scarring.
If you are unsure whether this device is safe for you to use, please consult your
physician or dermatologist.
If you take any kind of medication regularly and over a long period of time, please
consult your physician for any potential impact on skin sensitivity to light.
WARNINGS
DO NOT USE on …
scalp, eyebrows or anywhere near or around the eyes. Use in these areas may
permanently damage your eyes.
red, very blonde, grey or white hair. The device is not effective on these hair
colors.
nipples, genitals or around the anus. These areas may have a darker skin color
and/or greater hair density and using the device in these areas may cause
discomfort/pain or injure your skin.
dark brown or black spots such as freckles, birthmarks, moles or warts in the
treatment area.
a tattoo or permanent makeup in the treatment area.
beard / facial hair for men.
DO NOT look directly into the glass filter (10) or attempt to activate the device
toward the eyes. To protect the safety of your eyes and those of individuals nearby,
the device will only activate when both skin tone sensors are placed against the
skin. If at any time the device activates when both sensors are NOT in contact with
the skin, STOP use immediately and contact your retailer.
DO NOT USE more than once a week on the same area. This will not speed up the
results and may increase the chances of injury to your skin.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 591603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 5 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 5 of 38
6
PRECAUTIONS
The device is intended for a single user.
It is not intended for use by people under 18 years old.
People with reduced physical, sensory or mental capabilities or lack of experience
and knowledge, may use the device if they have been given supervision or instruction
concerning the safe use of the device and understand the hazards involved.
Children should be supervised to ensure that they do not play with the device.
Always keep the device out of children’s reach.
ELECTRICAL AND FIRE SAFETY
The device contains fragile parts and has to be handled with care. Regularly check
the device and cords for visible signs of damage. In case of damage or cracks, stop
using the device. Electric shock may result from using a damaged device. In case
of defects, have the device checked and repaired by an authorized service center.
Unqualified repair work can lead to extreme hazards for the user. Always unplug the
device after use.
DANGER
Never attempt to repair and open the device, as this may expose you to dangerous
electrical components and to pulsed light energy, either of which may cause
serious bodily damage and/or permanent eye injury.
WARNING
To prevent any damage or risk of electric shock or fire hazard, operate this device
only with the power supply (7) (type 6037) provided.
DO NOT use in or near water and wet surfaces such as bathtubs, showers,
basins or other vessels that may contain water. If the device becomes wet,
it should not be used. Electric shock may result from using a wet device.
DO NOT use if the device is damaged (e.g. cracked housing, cord damage etc).
Internal parts contain electric charges that are hazardous.
DO NOT use if the glass filter (10) is cracked or missing. Regularly inspect the
glass filter for damage.
DO NOT touch the glass filter during or directly after use since it will get hot.
DO NOT use petroleum-based or flammable cleaning agents (alcohol, acetones)
on the device as these pose a fire risk.
DO NOT use abrasive cleaning agents. These may damage the device or scratch
the glass filter.
DO NOT attempt to use this device other than for removing unwanted hair.
DO NOT activate the device onto any surface other than skin.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 691603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 6 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 6 of 38
7
DO NOT activate the device if the treatment window (1) is not placed in full contact
with the skin.
DO NOT block the cooling vents. The device may overheat and pose an electric
shock risk or fire hazard.
HOW TO USE
Preparing the treatment area
Remove any visible hair on the skin before using the device. You may use your preferred hair removal
method. Clean the treatment area and pat it dry.
To power on the device:
First assemble the power supply (7) by clicking in an appropriate pin insert (8). (The power supply is
provided with a release button (7a) for removing the pin insert.) Plug the power supply (7) into the socket
(6) and connect it to an electrical outlet. The LED power bars (3) will light up once and, a fan starts
running. This means the device is in READY mode. During operation, the device will heat up slightly.
Automatic skin tone reading
When both skin tone sensors (2) have skin contact, the device reads your skin tone and selects the
appropriate light intensity which is indicated by white LEDs on the Power bars (3). These confirm that the
device is ready to flash.
light skin tone U high light intensity
dark skin tone U low light intensity
no LEDs
no skin contact U device cannot be activated
red LED
invalid skin tone U device cannot be activated
Patch Test
Before your first treatment, we recommend you test your skin for reaction to Braun Silk·expert on a small
area of skin of the body part you plan to treat (about 2 x 3 cm in size; equivalent to the size of two flashes,
side by side).
Perform a patch test as described BELOW in chapter «TREATMENT MODES», section «Precision mode».
Wait 48 hours to examine the test area. If the skin appears normal, begin your first treatment. If a skin
reaction develops, discontinue using the device and consult your physician. Do not treat the patch tested
area for at least one week after the test.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 791603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 7 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 7 of 38
8
TREATMENT MODES
Depending on the area you wish to treat you can choose between Gliding mode and Precision mode:
The gliding mode enables fast and efficient treatments and is recommended for large skin surface areas
(e.g. legs, arms, chest and back) while the precision mode is recommended for treating sensitive or small,
hard-to reach areas such as knees, shins, ankles, bikini line or underarm and face for females.
The area to be treated has to be hair-free, clean and dry. Before pressing the treatment button, look away
from the device to avoid the bright light.
Gliding mode Precision mode
1. Place the treatment window (1) firmly on your skin, ensuring both skin sensors (2) have skin contact.
Power bars (3) show white LEDs.
2. Press and hold the treatment button (5). The
device will begin to flash.
2. Press and instantly release the treatment button
(5). The device will emit a flash.
3. Move the device slowly and continuously from
the bottom to the top of the treatment area.
Make sure to always keep full skin contact so
that the device flashes continuously.
3. Lift off the device and place it onto the next
adjacent spot to be treated. Again, wait for the
power bars to show white LEDs. Then press and
release the treatment button.
Once you have completed your first gliding stroke,
lift the device off the treatment area. Repeat steps
1 to 3 to treat the next adjacent area in a parallel
stroke.
Continue treatment spot by spot until you have
completed the entire area you wish to treat.
Make sure to avoid missed areas by placing the treatment window directly next to the previously treated
spot without leaving any space between treated areas.
If you feel intense pain, stop treatment immediately and consult your physician before using the device again.
Gentle mode
For sensitive areas (or first time users) you may set the device to Gentle mode by pressing the Gentle
mode button (4). The Gentle mode indicator will illuminate to indicate it is activated. To de-activate Gentle
mode, simply press the button (4) again. The Gentle mode indicator will go off and the device will return to
its standard settings.
Gentle Mode reduces the light intensity. More treatments may be required to see the desired effects.
The Gentle Mode is also recommended when doing the monthly maintenance treatments.
Standby mode
After 10 minutes of inactivity, the device will revert to standby mode (which will be indicated by one blinking
light on the power indicator bars). To return to READY mode, press any key or remove/replace the power cord.
Sleep mode
If the device is not operated (no button push) for 60 minutes, it will enter sleep mode (low power state).
The Power bar LEDs are off. To return to READY mode, press any key or remove/replace the mains cord.
On wake-up the device will follow the standard Power on procedure (power bars will light up completely
once).
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 891603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 8 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 8 of 38
9
Facial treatment (female usage only)
Before Treatment
Ensure you have done a patch test before treating the face (see chapter «Patch Test»).
Remove any visible hair and cosmetics, lotions and creams from the area you wish to treat.
You may choose to use a mirror to help position the treatment window on the face.
Treating the face, cheek and jaw (use the «Precision mode»)
Place the treatment window on your skin. Wait for the power bars to show white LEDs. Before pressing the
treatment button, close your eyes or look away to avoid the bright light. Avoid treating the same area twice
as this may increase the chance of producing adverse reactions.
Upper lip area
Avoid contact with the lips and the nostrils. The central area below the nostrils is often sensitive.
Do not use on permanent / semi-permanent lip liner on the lip margin.
TIP: You can press your lips together to ensure that the light does not activate on the upper lip itself.
Neck and chin
Hair growth under the chin can be denser and coarser. This can sometimes lead to slight skin reddening
following a treatment. This redness is temporary and should completely disappear after 24 hours.
NOTE:
If redness or a burning sensation occurs and lasts for several minutes, apply a cool cloth/pad to soothe
the area.
If any pigment changes in the skin, e.g., lightening or darkening, are observed, stop using the device.
Seek medical advice to determine the cause which may be due to an underlying medical condition.
TREATMENT PLAN
Start-up phase one treatment per week (4-12 times)
Maintenance treatment continue treating to your needs, e.g. once a month.
The typical hair growth cycle varies between individuals and could take up to 16 months depending on
body area (underarm, lower leg, bikini area). Since only hairs in their growing phase are susceptible to
treatment with light, it is important to do multiple treatments to achieve continuously smooth skin. For this
reason, we recommend a start-up phase with one treatment per week over a period of 4 -12 weeks
In case you no longer see hair growing, you do not need to complete the full 12 weekly treatments. You can
switch to the maintenance treatments.
AFTER TREATMENT
Once you have completed your treatment, unplug the power supply from the electrical outlet to turn off the
device.
Do not touch or clean the glass filter (10) for at least 5 minutes after use to allow it to cool down.
After treatment, we recommend using sunscreen SPF 15 whenever treated areas may be exposed to the
sun. We recommend avoiding exposure to artificial light sources, such as tanning booths or solariums.
Avoid any activity or skin products that may irritate your skin for 24 hours after treatment. This includes
using hot tubs or saunas, wearing tight-fitting clothing, using bleaching creams, perfumed products or
peeling products. The above may cause irritation, such as itching and redness, in the treated areas.
MAINTENANCE AND STORAGE
After use, wipe down the device and especially the treatment window with a dry, lint-free cloth. Do not
rinse or immerse the device in water or any other liquid.
To ensure maximum performance, it is important to keep the treatment window reflector (9) free from
dirt, hair or other debris. To aid in the cleaning of this part, the front section is removable. Once
removed, it can be cleaned with a slightly damp cloth. Always ensure the front section is completely dry
before re-fitting it.
Store the device in a cool, dry place. Make sure the treatment window and skin sensors are protected
from damage.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 991603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 9 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 9 of 38
10
POSSIBLE SIDE EFFECTS
Some people will experience slight discomfort (e.g. heat or redness of the skin) when using the device –
this is normal. You may feel heat and tingling when activating the flash, followed by redness in the skin.
This type of reaction usually disappears within 24 hours. Adverse reactions are usually immediate or
appear within 24 hours. In rare cases, they may take up to 72 hours to appear. If you experience abnormal
skin reactions please contact your physician.
Side effect How to assess and react
Warm feeling or tingling sensations during
treatment which typically disappear after a few
seconds to a minute and decrease with continued
use.
This is expected and normal for all IPL treatments.
You can keep on using the device as instructed.
Discomfort or pain is intense during treatment or
persists after a treatment.
Stop using the device and consult your physician
before using it again.
Skin redness during or after treatment which
disappears within minutes to several hours.
This is expected and normal for all IPL treatments.
You can keep on using the device as instructed
once skin redness has disappeared.
Skin redness which does not go away within
24 - 48 hours after treatment.
Stop using the device and consult your physician
before using it again.
In very rare cases:
Swelling and redness around the hair follicle that
disappears within two or three days.
You can keep on using the device as instructed
once swelling and redness around the hair follicle
has disappeared.
Swelling and redness around the hair follicle that
does not disappear within two to three days.
Stop using the device and consult your physician
before using it again.
Temporary changes in skin color (lightening or
darkening).
If your skin color changes, stop using the device
and consult your physician.
Increase in hair growth in areas of treatment (more
likely to be seen with subjects of Mediterranean
descent).
If this increase persists over several treatments,
stop using the device and consult your physician.
TROUBLE SHOOTING
The following troubleshooting guide may help you solving initial problems you may experience with this
device.
Problem Solution
Power bars do not light up when treatment window
is placed on the skin.
Make sure the device is connected to an electrical
outlet and in Ready mode.
Ensure both skin tone sensors are in full contact
with the skin. If needed, move the device in a way
that both skin tone sensors get skin contact.
The device doesn’t work on small areas. Both skin tone sensors must be in contact with the
skin. If the area to be treated is too small or
curved, no valid skin tone can be read and the
device cannot be activated. Reposition the device
to ensure both sensors make contact with the skin.
On the power bar, only the first LED illuminates
red.
Invalid skin tone reading. Your skin is either too
light or too dark. For safety reasons, the device
cannot be activated.
First LED on power bars flashes white. The device has gone into STANDBY mode.
To reactivate, press any key.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1091603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 10 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 10 of 38
11
First LED on power bars flashes red. Removable treatment window reflector (9) has
been taken off. Replace it.
The power bars show an unfamiliar pattern of one
red LED shining along with individual white LEDs.
Device error. Device will not operate.
Remove and replace the power supply connection.
If error persists, contact a Braun Service Centre
for repair.
All white LEDs flash. End of product lifetime. Maximum number of
flashes (250.000) has been reached.
The device is broken, cracked or appears
defective.
DO NOT USE if the device or the power supply is
damaged. If you are in any doubt about the safety
or suspect it is damaged in any way, you must not
use it.
Disposal
The product contains recyclable electronic waste. To protect the environment, do not dispose of it
in the household waste, but take it to appropriate local collection points.
Subject to change without notice
Guarantee
We grant a 2 year guarantee on the product commencing on the date of purchase. Within the guarantee
period we will eliminate any defects in the appliance resulting from faults in materials or workmanship, free
of charge either by repairing or replacing the complete appliance at our discretion.
This guarantee extends to every country where this appliance is supplied by Braun or its appointed
distributor.
This guarantee does not cover: damage due to improper use, normal wear or use as well as defects that
have a negligible effect on the value or operation of the appliance. The guarantee becomes void if repairs
are undertaken by unauthorized persons and if original Braun parts are not used.
To obtain service within the guarantee period, hand in or send the complete appliance with your sales
receipt to an authorised Braun Customer Service Centre (address information available online at
www.service.braun.com).
For UK only:
This guarantee in no way affects your rights under statutory law.
For Australia & New Zealand only:
Warranty
In Australia, our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
The benefits given by this warranty are in addition to other rights and remedies of the consumer
law.
For warranty claims please contact:
Procter & Gamble Australia Pty Ltd
Level 4, 1 Innovation Road
Macquarie Park, NSW 2113
Telephone (AU): 1 800 641 820
Telephone (NZ): 0 800 108 909
Email (AU and NZ): Visit link https://pgconsumersupport.secure.force.com/ContactUs/emailus
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1191603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 11 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 11 of 38
12
Our Warranty
This appliance is also covered by a 24 Month Replacement Warranty commencing on the date of purchase
(Our Warranty).
Our Warranty applies in all States and Territories of Australia and in New Zealand and is in
addition to any mandatory statutory obligations imposed on Procter & Gamble Australia Pty. Ltd.,
its distributors and its manufacturer. Our Warranty does not purport to exclude, restrict or modify
any such mandatory statutory obligations.
Our Warranty only covers defects in the appliance resulting from faults in workmanship or materials.
Therefore, if your appliance becomes faulty as a result of faults in workmanship or materials, it will be
exchanged by your retailer, on presentation of proof of purchase.
Our Warranty only applies to domestic or household use of this appliance and the warranty will only apply if
the correct operating instructions included with this product have been followed. For any appliance
replaced under this warranty, Our Warranty ends on the expiry of the warranty period that applied to the
original appliance.
Our Warranty does not cover:
A. Damage arising from improper use or operation on incorrect voltages.
B. Breakages to shaver foils, glass jars, etc.
C. Normal wear due to moving parts.
D. Repairs undertaken by unauthorised service personnel or use of non genuine parts.
E. Appliances that are outside the warranty period or are not faulty.
This appliance is not intended for use by young children or infirm persons without supervision. Young
children should be supervised to ensure that they do not play with the appliance.
If the appliance is powered by a cord extension set or electrical portable outlet device these should be
positioned so they are not subject to splashing or ingress of moisture.
To the extent permitted by the laws of the Commonwealth of Australia and New Zealand and applicable
laws of a State or Territory of Australia, and without affecting any mandatory statutory obligations imposed
by law, Our Warranty is given in exchange for any other rights you may have against Procter & Gamble
Australia Pty. Ltd. or its distributors or manufacturer, whether at law, in tort (including negligence), in equity
or under statute.
Please retain proof of purchase of this appliance. If you have any questions in relation to Our Warranty,
please call our Consumer Service line (see below for numbers).
If you intend to make a claim please telephone our Customer Service line on the numbers set out below to
obtain information about your claim and any costs associated with claiming under Our Warranty. You will
bear the cost of returning your product to us.
Repairs and service
If you are sending your appliance for repair under Our Warranty, please pack the appliance adequately and
send it to your nearest Service Agent, at your expense. For service or replacement parts refer to the
authorised Service Agents listed overleaf. Local Service Agents may change from time to time – in that
event please contact the Consumer Service free call number below for updated local service agent details.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1291603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 12 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 12 of 38
13
Australian & New Zealand Service Agents
VICTORIA & TASMANIA
Statewide Services Pty Ltd trading
as J A Appliances
17-19 Hossack Avenue
Coburg North, VIC 3058
Tel. (03) 8371 9100
Fax. (03) 9355 8644
QUEENSLAND
Walters Import trading as Brisbane Appliance Service Centre
449 Beaudesert Road
Moorooka QLD 4105
Tel. (07) 3277 0360
Fax. (07) 3274 2909
WESTERN AUSTRALIA
Mark 1 Appliances
Unit 1, 46 Abernethy Road
Belmont, WA 6104
Tel. (08) 9475 0911
Fax. (08) 9475 0922
NEW SOUTH WALES & ACT
Faulder Appliance Services Pty Ltd
Shop 4,
9 Evans Road,
Rooty Hill, NSW 2766
Tel. (02) 9625 3064
Fax. (02) 9625 3037
SOUTH AUSTRALIA & NT
Adelaide Service Centre
Shop B2,
Parkholme Shopping Centre
319 Oaklands Road, Parkholme
Adelaide, SA 5043
Tel. (08) 8357 5800
Fax. (08) 8357 5833
NEW ZEALAND
Key Service Ltd
7D Echelon Place East Tamaki
Manukau City
Auckland
New Zealand
(PO Box 38569, Howick, Auckland,
New Zealand)
Tel. (09) 916 0960
Fax. (09) 916 0970
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1391603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 13 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 13 of 38
14
Français
Nos produits sont conçus pour répondre aux plus hautes normes de qualité, de fonctionnalité et de
design. En utilisant une technologie lumineuse professionnelle, Braun Silk·expert à lumière pulsée intense
(IPL) vous permet d’épiler de façon permanente les poils visibles et indésirables, sans avoir besoin de
sortir de chez vous. Avant d’utiliser l’appareil, veuillez lire attentivement les instructions, notamment les
contre-indications, les avertissements et les informations relatives à la sécurité. Conservez-les pour un
usage ultérieur.
Cet appareil a été conçu afin de diminuer, après une certaine période de traitement, la repousse des poils
à long terme. Les parties du corps à privilégier pour l’utilisation de cet appareil comprennent :
Femmes : Jambes, bras, aisselles, bikini et visage (en dessous des pommettes)
ATTENTION : Ne pas utiliser l’appareil au niveau des yeux et du front.
Hommes : Épaules, torse, dos, bras, ventre et jambes
ATTENTION : Ne pas utiliser sur le visage, le cou et les parties génitales.
Utiliser cet appareil pour vous raser ou pour l’épilation des poils du visage peut être à
l’origine de modifications indésirables des caractéristiques faciales.
Silk·expert de Braun ne convient pas à tout le monde. Il est très efficace sur des teints clairs et légèrement
foncés et chez les personnes ayant des cheveux foncés. Veuillez vous référer au tableau des types de
teints et de couleurs des cheveux sur page 3 afin de déterminer si l’appareil vous conviendra.
Description
1 Fenêtre de traitement
2 Capteurs de teint SensoAdapt™
3 Barres LED
4 Bouton et indicateur Mode doux
5 Bouton traitement
6 Prise d’alimentation
7 Alimentation électrique avec bouton d’éjection (7a)
8 Broche
9 Réflecteur fenêtre de traitement
10 Filtre en verre
Comment ça marche ?
Silk·expert de Braun agit sous la surface de la peau en ciblant la mélanine contenue au niveau du follicule
pileux et permet d’interrompre le cycle de repousse des poils. Avec une utilisation continue et régulière,
l’énergie de la lumière empêche les poils indésirables d’atteindre la surface de la peau.
Les capteurs de teint SensoAdapt™ (2) intelligents détectent avant chaque flash la couleur de votre teint
et adaptent automatiquement l’intensité lumineuse nécessaire pour une plus grande efficacité en toute
sécurité. Ceci permet de traiter les teints appropriés. Cependant, si votre teint est trop foncé, l’appareil ne
fonctionnera pas.
CONTRE-INDICATIONS
NE PAS UTILISER l’appareil ...
si votre peau est plus foncée que le teint V présenté sur le tableau des teints
page 3. Étant donné qu’une peau foncée absorbe davantage d’énergie
lumineuse, traiter une peau très foncée peut causer douleurs et sensations
désagréables, être à l’origine d’effets indésirables (par ex., brûlures, cloques,
décoloration ou cicatrices) et endommager la peau.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1491603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 14 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 14 of 38
15
si vous êtes enceinte, si vous allaitez ou si vous avez moins de 18 ans car
l’appareil n’a pas été testé sur ce type de personnes.
si vous avez des antécédents de cancer cutané ou de lésions précancéreuses
(par ex., naevi ou nombreux grains de beauté).
si vous avez récemment bronzé (bronzage naturel ou artificiel). Une exposition
au soleil a tendance à davantage sensibiliser votre peau et cette dernière sera
particulièrement sujet aux effets indésirables du traitement à lumière pulsée
intense (IPL) (brûlure, cloque, décoloration ou cicatrice). Après un traitement à
lumière pulsée intense (IPL), évitez également une exposition au soleil directe et
non protégée. Votre peau peut être extrêmement sensible et particulièrement
sujette aux brûlures.
Certaines conditions empêchent également l’utilisation de cet appareil.
NE PAS UTILISER cet appareil si les conditions suivantes existent :
Vous avez une condition médicale chronique.
Vous avez une maladie cutanée chronique (psoriasis, vitiligo, etc.) ou une peau
endommagée (coups de soleil, coupures, blessures ouvertes ou infections) au
niveau des zones que vous souhaitez traiter.
Vous avez des varices au niveau des zones que vous souhaitez traiter.
Vous avez une sensibilité connue à la lumière du soleil (photosensibilité) ou vous
prenez des médicaments qui sensibilisent davantage votre peau (Retin-A,
Accutane et/ou autres rétinoïdes topiques).
Vous avez subi un traitement abrasif (peeling) sur la zone que vous souhaitez traiter.
Si vous avez l’une des conditions ci-dessus, l’appareil peut endommager votre
peau ou empirer des conditions existantes. Vous pouvez présenter les effets
indésirables suivants : brûlures, cloques ou modifications de la couleur de la
peau (hyper- ou hypo-pigmentation) ou cicatrices.
Si vous n’êtes pas certain(e) de pouvoir utiliser cet appareil en toute sécurité,
veuillez consulter votre médecin ou dermatologue.
Si vous suivez régulièrement un traitement médical depuis longtemps, veuillez
consulter votre médecin afin de déterminer tout impact potentiel ou toute
sensibilité cutanée à la lumière.
AVERTISSEMENTS
NE PAS UTILISER sur ...
le cuir chevelu, les sourcils ou autour des yeux. Utiliser cet appareil sur ces zones
peut être à l’origine de lésions oculaires permanentes.
des poils roux, très blonds, gris ou blancs. L’appareil n’est pas efficace sur ces
couleurs de poils.
les mamelons, les parties génitales ou autour de l’anus. Au niveau de ces zones,
la peau peut avoir une coloration plus foncée et/ou une densité pilaire plus
importante. Utiliser l’appareil sur ces zones peut causer douleurs et sensations
désagréables ou encore endommager votre peau.
des taches noires ou foncées comme les taches de naissance, grains de beauté
ou verrues sur la zone à traiter.
un tatouage ou maquillage permanent sur la zone à traiter.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1591603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 15 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 15 of 38
16
Barbe/Pilosité faciale chez les hommes
NE PAS diriger votre regard sur le filtre en verre (10) ou tenter d’activer l’appareil
dans la direction des yeux. Pour protéger vos yeux et les yeux de ceux qui se
trouvent à proximité, l’appareil ne s’activera que lorsque les capteurs de teint
seront placés contre la peau. Si, à tout moment, l’appareil s’active alors que les
deux capteurs ne sont PAS en contact avec la peau, ARRÊTEZ immédiatement
l’appareil et contactez votre revendeur.
NE PAS UTILISER plus d’une fois par semaine sur la même zone. Ceci n’accélèrera
pas les résultats et peut augmenter les risques de blessures.
PRÉCAUTIONS
L’appareil ne peut être utilisé que par une seule personne.
L’appareil ne doit pas être utilisé par les personnes âgées de moins de 18 ans.
Cet appareil peut être utilisé par des personnes dont les capacités physiques,
sensorielles ou mentales sont réduites, si elles ont pu bénéficier d’une
surveillance ou d’instructions préalables concernant l’utilisation de l’appareil en
toute sécurité et si elles comprennent les dangers encourus.
Les enfants doivent être surveillés pour s’assurer qu’ils ne jouent pas avec
l’appareil. Tenir cet appareil hors de portée des enfants.
SÉCURITÉ DES INSTALLATIONS ÉLECTRIQUES ET ANTI-FEU
L‘appareil contient des pièces fragiles et doit être manipulé avec précaution.
Veuillez régulièrement vérifier l’appareil et les câbles et vous assurer qu’il n’existe
pas de signes d’endommagement visibles. En cas d’endommagement ou de
fissures, cessez d’utiliser l’appareil. Des chocs électriques sont susceptibles de se
produire si vous utilisez un appareil endommagé. En cas de défauts, faites vérifier
l’appareil et, le cas échéant, faites-le réparer dans un centre de service autorisé.
Une réparation effectuée par une personne non qualifiée peut être extrêmement
dangereuse pour l’utilisateur. Veuillez toujours débrancher l’appareil après utilisation.
DANGER Ne tentez jamais de réparer ni d’ouvrir l’appareil car ceci peut vous exposer
à des composants électriques dangereux et à l’énergie de lumière pulsée, pouvant
causer d’importantes blessures physiques et/ou des lésions oculaires permanentes.
ATTENTION Pour éviter tout endommagement, risque de choc électrique ou
danger au moment de l’épilation, utilisez l’appareil uniquement avec l’alimentation
électrique (7) fournie ( type 6037).
NE PAS utiliser dans l’eau ou à proximité d’eau et de surfaces humides
comme les baignoires, douches, lavabos ou autres récipients pouvant
contenir de l’eau. Ne jamais utiliser un appareil mouillé. Des chocs
électriques sont susceptibles de se produire si vous utilisez un appareil humide.
NE PAS utiliser si l’appareil est endommagé (boîtier fissuré, câble endommagé,
etc.) L’intérieur contient des composants électriques dangereux.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1691603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 16 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 16 of 38
17
NE PAS utiliser si le filtre en verre (10) est fissuré ou manquant. Inspectez
régulièrement le filtre en verre et vérifiez qu’il n’est pas endommagé.
NE PAS toucher le filtre en verre lors de l’utilisation ou immédiatement après car il
sera chaud.
NE PAS utiliser de nettoyants inflammables (alcool, acétone) ou dérivés du pétrole
sur l’appareil car ils peuvent présenter un risque d’incendie.
NE PAS utiliser de nettoyants abrasifs. Ils peuvent endommager l’appareil ou
érafler le filtre de verre.
NE PAS tenter d’utiliser l’appareil pour d’autres raisons que l’épilation.
NE PAS activer l’appareil sur une surface autre que la peau.
NE PAS activer l’appareil si la fenêtre de traitement (1) n’est pas entièrement
placée au contact de la peau.
NE PAS bloquer les voies d’aération. L’appareil peut surchauffer et présenter un
risque de choc électrique ou d’incendie.
CONSEILS D’UTILISATION
Préparation de la zone à traiter
Épilez les poils visibles avant d’utiliser l’appareil. Utilisez votre méthode d’épilation privilégiée. Lavez la
zone à traiter et séchez-la soigneusement.
Pour l’alimentation de l’appareil :
Assemblez tout d’abord l’alimentation électrique (7) avec une broche appropriée (8). (L’alimentation est
dotée d’un bouton d’éjection (7a) pour retirer la broche.) Connectez l’alimentation électrique (7) à la prise
d’alimentation (6) avant de la brancher à une prise électrique. Les barres LED (3) s’allumeront
immédiatement et un ventilateur commencera à fonctionner. Ceci signifie que l’appareil est en mode PRÊT.
Lors du fonctionnement, l’appareil chauffera légèrement.
Lecture automatique du teint
Quand les deux capteurs de teint (2) sont en contact avec la peau, l’appareil lit le teint et sélectionne
l’intensité lumineuse appropriée indiquée par des LED de couleur blanche au niveau des barres LED (3).
Celles-ci indiquent que l’appareil est prêt à flasher.
teint clair U intensité lumineuse élevée
teint foncé U intensité lumineuse faible
pas de lumière
pas de contact avec la peau U l’appareil ne peut pas être
activé
lumière rouge
teint non valide U l’appareil ne peut pas être activé
Test épicutané
Avant d’utiliser l’appareil pour la première fois, nous vous recommandons de tester une petite partie de
votre peau et de vous assurer que Braun Silk·expert ne produit aucune réaction sur la partie du corps à
traiter (environ 2 x 3 cm de peau ; équivalent à la taille de deux flashes, côte à côte).
Effectuez le test tel que décrit ci-dessous dans le chapitre « MODES DE TRAITEMENT », section « Mode
précision ». Attendez 48 heures puis examinez la zone de test. Si la peau semble normale, vous pouvez
alors effectuer votre premier traitement. Si la peau présente une quelconque réaction cutanée, n’utilisez
pas l’appareil et consultez votre médecin. N’effectuez aucun traitement sur la zone de test pendant au
moins une semaine après le test.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1791603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 17 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 17 of 38
18
MODES DE TRAITEMENT
En fonction de la zone que vous souhaitez traiter, vous pouvez choisir entre Mode Glisse et Mode Précision :
Le Mode Glisse permet des traitements rapides et efficaces et nous le recommandons pour les zones de
peau importantes (comme les jambes, les bras, le torse et le dos). Le Mode Précision, quant à lui, est
recommandé pour les zones sensibles ou de petite taille, les zones difficiles à atteindre comme les
genoux, les tibias, les chevilles, la ligne du bikini ou les aisselles ainsi que le visage pour les femmes.
La zone à traiter doit être parfaitement épilée, propre et sèche. Avant d’appuyer sur le bouton traitement,
éloignez vos yeux de l’appareil afin d’éviter tout contact avec la lumière.
Mode Glisse Mode Précision
1. Placez fermement la fenêtre de traitement (1) sur la peau et assurez-vous que les capteurs (2) sont
en contact avec la peau. Les barres LED (3) affichent une lumière blanche.
2. Enfoncez et maintenez le bouton traitement (5).
L’appareil commence à flasher.
2. Enfoncez et relâchez immédiatement le bouton
traitement (5). L’appareil émettra un flash.
3. Déplacez l’appareil lentement et en continu de
bas en haut de la zone à traiter. Assurez-vous
de toujours maintenir le contact avec la peau
pour que l’appareil flashe de manière continue.
3. Relevez l’appareil et placez-le sur la zone à
traiter suivante. Attendez que les barres LED
émettent une lumière blanche. Enfoncez alors
et relâchez immédiatement le bouton
traitement.
Une fois le premier mouvement terminé, soulevez
l’appareil de la zone de traitement. Répétez les
étapes 1 à 3 pour traiter la zone adjacente suivante
dans un mouvement parallèle.
Continuez ainsi jusqu’à ce que toute la zone que
vous souhaitiez traiter soit terminée.
Pour ne manquer aucune zone, placez la fenêtre de traitement directement à côté de l’endroit traité au
préalable sans laisser d’espace entre les zones traitées.
Si vous ressentez une douleur intense, arrêtez immédiatement le traitement et consultez votre médecin
avant d’utiliser à nouveau l’appareil.
Mode doux
Pour les zones sensibles (ou lors d’une première utilisation de l’appareil), vous pouvez régler l’appareil sur
Mode doux en appuyant sur le bouton Mode doux (4). L’indicateur Mode doux s’allumera pour indiquer
qu’il est activé. Pour désactiver le Mode doux, il suffit d’appuyer de nouveau sur le bouton (4). L’indicateur
Mode doux s’éteint et l’appareil repasse aux réglages standards.
Le Mode doux réduit l’intensité de la lumière. Des traitements supplémentaires peuvent être nécessaires
pour obtenir les effets désirés. Le Mode doux est également recommandé pour les traitements d’entretien
mensuels.
Mode attente
Après 10 minutes d’inactivité, l’appareil repasse au mode attente (indiqué par une lumière clignotante sur
les barres LED). Pour repasser au mode PRÊT, appuyez sur n’importe quel bouton ou retirez/replacez le
câble d’alimentation.
Mode veille
Si l’appareil n’est pas utilisé (aucun bouton n’est activé) pendant 60 minutes, il entrera en mode veille
(faible alimentation). Les barres LED sont éteintes. Pour repasser au mode PRÊT, appuyez sur n’importe
quel bouton ou retirez/replacez le câble secteur. Une fois réactivé, l’appareil suivra la procédure standard
pour « s’allumer » (les barres LED s’allumeront immédiatement et complètement).
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1891603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 18 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 18 of 38
19
Traitement du visage (pour les femmes uniquement)
Avant le traitement
Assurez-vous d’effectuer un test épicutané avant de traiter le visage (voir chapitre « Test épicutané »).
Épilez les poils visibles et éliminez tout maquillage, lotion et crème de la zone à traiter.
Vous pouvez utiliser un miroir pour vous aider à positionner la fenêtre de traitement sur le visage.
Traitement visage, joues et mâchoires (utiliser le mode Précision)
Placez la fenêtre de traitement sur votre peau. Attendez que les barres LED émettent une lumière blanche.
Avant d’appuyer sur le bouton traitement, fermez les yeux ou éloignez vos yeux de l’appareil afin d’éviter
tout contact avec la lumière. Évitez de traiter la même zone deux fois car cela peut augmenter les risques
d’effets indésirables.
Zone de la lèvre supérieure
Évitez tout contact avec les lèvres et les narines. La zone centrale en dessous des narines est souvent
très sensible.
Ne pas utiliser sur un maquillage permanent/semi-permanent sur la bordure des lèvres.
CONSEIL : Vous pouvez maintenir vos lèvres scellées pour vous assurer que la lumière ne s’active pas
sur la lèvre supérieure elle-même.
Cou et menton
Les poils qui poussent sous le menton ont tendance à être plus denses et plus rudes. Le traitement peut
alors causer des rougeurs sur les peaux claires. Ces rougeurs sont temporaires et devraient entièrement
disparaître au bout de 24 heures.
NOTE :
Si une rougeur ou une sensation de brûlure se produit et persiste pendant quelques minutes, appliquez
un linge frais pour soulager la zone.
Si des changements dans la pigmentation de la peau (si la peau devient plus claire ou plus foncée) sont
observés, cessez d’utiliser l’appareil. Demandez conseil à votre médecin afin de déterminer s’il existe
une condition médicale sous-jacente.
PLAN DE TRAITEMENT
Phase de démarrage un traitement par semaine (4 à 12 fois)
Traitement d’entretien Continuez à traiter selon vos besoins, par ex. une fois par mois
Le cycle typique de repousse du poil varie d’un individu à l’autre et peut prendre de mois en fonction de la
partie du corps (aisselles, mollets, bikini). Étant donné que seuls les poils dans leur phase de repousse
sont susceptibles de répondre au traitement par lumière, il est important de multiplier les traitements pour
obtenir une peau complètement lisse. Pour cette raison, nous recommandons une phase de démarrage
avec un traitement par semaine pendant une période de 4 à 12 semaines.
Si la repousse des poils ne se produit plus, il n’est pas nécessaire de terminer les 12 traitements
hebdomadaires. Vous pouvez passer au traitement d’entretien.
APRÈS LE TRAITEMENT
Une fois le traitement terminé, débranchez le câble secteur de la prise électrique pour éteindre l’appareil.
Ne pas toucher ou nettoyer le filtre en verre (10) pendant au moins 5 minutes après utilisation afin qu’il
refroidisse.
Après le traitement, nous vous recommandons d’utiliser une protection solaire FPS 15 quand les zones
sont susceptibles d’être exposées au soleil. Nous vous recommandons d’éviter une exposition à des
sources de lumière artificielle comme les cabines de bronzage et les solariums.
Dans les 24 heures qui suivent le traitement, évitez toute activité ou tous produits pour la peau qui
pourraient l’irriter. Ceci inclut les spas ou les saunas, le port de vêtements serrés, l’utilisation de crèmes
blanchissantes, de produits parfumés ou de produits d’abrasion superficielle. Ils peuvent être à l’origine
d’irritations, de démangeaisons et de rougeurs au niveau des zones traitées.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 1991603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 19 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 19 of 38
20
ENTRETIEN ET STOCKAGE
Après utilisation, essuyez l’appareil en insistant particulièrement sur la fenêtre de traitement avec un
linge sec et non pelucheux. Ne pas rincer ou plonger l’appareil dans de l’eau ou dans tout autre liquide.
Pour garantir une performance maximum, il est important d’éviter le contact du réflecteur de la fenêtre
de traitement (9) avec la poussière, les cheveux ou autres débris. Afin de bien nettoyer cette zone, il est
possible de retirer la partie avant. Une fois retirée, elle peut être nettoyée avec un linge légèrement
humide. Assurez-vous de toujours bien sécher cette partie avant de la replacer.
Gardez l’appareil dans un endroit sec et frais. Assurez-vous que la fenêtre de traitement et les capteurs
de teints sont bien protégés.
EFFETS INDÉSIRABLES POSSIBLES
Certaines personnes feront l’expérience de légers désagréments (chaleur ou rougeurs de la peau) lors
de l’utilisation de l’appareil. Ceci est tout à fait normal. Il est possible de ressentir de la chaleur et des
fourmillements quand vous activez le flash, ce qui sera suivi par des rougeurs cutanées. Ce type de réaction
disparaît habituellement dans les 24 heures. Les réactions indésirables apparaissent généralement
immédiatement ou dans les 24 heures. Dans de rares cas, elles peuvent se manifester au bout de 72 heures.
Si vous faites l’expérience de réactions cutanées anormales, veuillez contacter votre médecin.
Effet indésirable De quoi s’agit-il et comment réagir
Sensations de chaleur et fourmillement pendant
le traitement qui disparaissent généralement au
bout de quelques secondes ou d’une minute et
diminuent au fur et à mesure de l’utilisation.
Ceci est normal dans tous les traitements à lumière
pulsée intense (IPL). Vous pouvez continuer à utiliser
l’appareil selon les instructions.
L’inconfort ou la douleur est intense lors du
traitement ou persiste après le traitement.
Cessez d’utiliser l’appareil et consultez votre
médecin avant de continuer à utiliser l’appareil.
Rougeurs cutanées pendant ou après le
traitement qui disparaissent au bout de quelques
minutes ou de plusieurs heures.
Ceci est normal dans tous les traitements à lumière
pulsée intense (IPL). Vous pouvez continuer à utiliser
l’appareil selon les instructions une fois que les
rougeurs ont disparu.
Rougeurs cutanées qui ne disparaissent pas
dans les 24 - 48 heures après le traitement.
Cessez d’utiliser l’appareil et consultez votre
médecin avant de continuer à utiliser l’appareil.
Très rarement :
Rougeurs et gonflements autour du follicule
pileux qui disparaissent dans les deux ou trois
jours.
Vous pouvez continuer à utiliser l’appareil selon les
instructions quand les rougeurs et gonflements
autour du follicule pileux ont disparu.
Rougeurs et gonflements autour du follicule
pileux qui ne disparaissent pas dans les deux
ou trois jours.
Cessez d’utiliser l’appareil et consultez votre
médecin avant de continuer à utiliser l’appareil.
Changements temporaires de la couleur de la
peau (plus claire ou plus foncée).
Si la couleur de la peau change, cessez d’utiliser
l’appareil et consultez votre médecin.
Augmentation de la repousse du poil au niveau des
zones de traitement (se produisant le plus souvent
chez les sujets d’origine méditerranéenne).
Si cette augmentation persiste malgré plusieurs
traitements, cessez d’utiliser l’appareil et consultez
votre médecin.
RÉSOLUTION DES PROBLÈMES
Le guide de résolution des problèmes suivant vous aidera à résoudre les problèmes qui peuvent surgir lors
de l’utilisation de cet appareil.
Problème Solution
Les barres LED ne s’allument pas quand la
fenêtre de traitement est placée sur la peau.
Assurez-vous que l’appareil est branché à la prise
électrique et en mode Prêt. Assurez-vous que les
capteurs de teint sont bien en contact avec la peau.
Si nécessaire, déplacez l’appareil de façon à ce que les
deux capteurs de teint soient en contact avec la peau.
91603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 2091603863_BD3001_3006_AP-ANZ_HK_S4-38.indd 20 18.01.18 13:0118.01.18 13:01
CSS APPROVED Effective Date 22Jan2018 GMT - Printed 29Mar2018 Page 20 of 38
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Braun BD 3005 Manuel utilisateur

Catégorie
Épilation légère
Taper
Manuel utilisateur

dans d''autres langues