Philips DDRC420FR Manuel utilisateur

Taper
Manuel utilisateur
DDRC420FR
RJ12
x 2
108 mm (4.25 in)
95 mm (3.74 in)
105 mm (4.13 in)
64 mm (2.52 in)
68 mm (2.68 in)
1 A 45 mm
(1.77 in)
45 mm
(1.77 in)
Relay Controller
Installation Instructions
Instructions d’installation
Installationsanweisungen
Instrucciones de instalación
Istruzioni per l’installazione
Installatie-instructies
インストー ル 手 順
安装指示
90%
IEC Pollution Degree II
Devices must be installed in an
approved enclosure by a qualied
electrician in accordance with all
national and local electrical and
construction codes and regulations.
Les appareils doivent être installés dans un lieu jugé
apte, par un électricien qualié et conformément
aux règles et normes locales et nationales en
matière d’électricité et de construction.
Die Geräte müssen von einem geprüften Elektriker
entsprechend allen nationalen und lokalen Elektro
– und Bauvorschriften in einem zugelassenen
Gehäuse installiert werden.
Los dispositivos se deben instalar en un recinto
aprobado por un electricista cualicado de
acuerdo a todos los reglamentos eléctricos y de
construcción locales y nacionales pertinentes
I dispositivi devono essere installati da un
elettricista qualicato in un luogo approvato, in
conformità a tutti gli standard e le norme nazionali
e locali vigenti in materia di impianti elettrici e
costruzioni edilizie.
Apparaten moeten door een erkende elektricien
worden geïnstalleerd in een goedgekeurde
behuizing in overeenstemming met alle nationale
en lokale elektriciteits – en bouwvoorschriften
en wetgeving.
付け際は、資格の電気技師に依頼
電気建設に関する国び地域法令に
従って、されている筐に取り付けてださい。
根据国家/地区及当地的电气与建筑规范和法规,该设
备必须由有资质的电工安装在经批准的外罩内。
50° C (122° F)
0° C (32° F)
20A 20A 20A 20A
0.62 Nm
5.5 Lb-in
5 mm2
10+ AWG
N
1 2 3 4
LIN IN IN INOUT OUT OUT OUT
CH1 CH2 CH3 CH4
SUPPLY
Not
Connected
ON
OFF
Installation example
Exemple d'installation
Installationsbeispiel
Ejemplo de instalación
Esempio di installazione
Installatievoorbeeld
安装示例
1 / 3
CH-CH 300 V (UL) / 400 V (CE)
20A 20A
NL1 L2
277/480 V
L3
1 2 3 4
ON
OFF
N L
IN IN IN INOUT OUT OUT OUT
CH1 CH2 CH3 CH4
SUPPLY
Not
Connected
3
CH-CH = 277 / 480 V
Installation example
Exemple d'installation
Installationsbeispiel
Ejemplo de instalación
Esempio di installazione
Installatievoorbeeld
安装示例
0.62 Nm
5.5 Lb-in
5 mm2
10+ AWG
1
2 A
2 B
B
68 mm (2.68 in)
oset 8 mm (0.31 in)
Output Ratings/Channel (CH)
General Use
Load Type CH1-CH4
16 A, 277 V
16 FLA (1 HP), 120 V
14.5 FLA (2 1/
2
HP), 240 V
14.1 FLA (3 HP), 277 V
500 A
Incandescent
Standard Ballast
Electronic Ballast
Inrush Current
Motor
CH-CH 300 V (UL) / 400 V (CE)
DDRC420FR 64 A (UL), 80 A (CE)
M
Output Ratings/Group
16 A, 277 V (UL)
20 A, 240 V (CE)
N
1 2 3 4
L
IN IN IN INOUT OUT OUT OUT
CH1
ON
OFF
CH2 CH3 CH4
SUPPLY
Not
Connected
ON
OFF
3
45
6
RS-485 DyNet
GND AUX/UL924
< 20 m
0.4 Nm
3.5 Lb-in
0.3-2.5mm2
22-12 AWG
2 A
SHLD
GND
D+
D-
+12 V
AUX/
UL924
RS-485 DyNet
8
7
100-240 V
0.25 A
NL
CH1 CH2 CH3 CH4
RJ12
RS-485 DyNet/DMX Rx
+12 V
D +
D -
GND
SHLD
AUX/
UL924
IN OUT IN OUT IN OUT IN OUT
µP
12 V 200 mA
SELV/Class 2 (UL)
IEC Overvoltage Category III
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice – This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged
to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the
equipment and receiver. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an
experienced radio/TV technician for help. Any modications not approved by the manufacturer of this device could void the user’s authority to operate this device.
This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B). Cet appareil numerique de la classe B est conforme a la norme NMB-
003 du Canada: CAN ICES-3(B)/NMB-3(B).
Installation of a home and building automation and control system shall comply with IEC 60364 (all parts). The temperature limits and current-carrying capacities
for the communication wires specied in IEC 60364-5-52 shall not be exceeded.
AZZ 377 0922 R21
© 2022 Signify Holding. All rights reserved. Specications are subject to
change without notice. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability
for any action in reliance thereon is disclaimed. Philips and the Philips
Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other
trademarks are owned by Signify Holding or their respective owners.
www.dynalite.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Philips DDRC420FR Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues