Regency F2450 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

Ce manuel convient également à

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
920-036a
0219WS026S
MODEL: F2450M
Classic™ Freestanding Woodstove
F2450M
12.10.19
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
Tested by:
www.regency-fire.com
French Manual Download:
Manuel en Français:
2 | F2450M Regency Freestanding Woodstove
Thank-you for purchasing a
REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about
your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
"This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this
setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual. Failure to follow
the manual details can lead to smoke and CO emissions spilling into the home. It is recommended to have monitors in areas that are
expected to generate CO such as heater fueling areas.
"U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using cord wood. Tested
to ASTM E3053. Model Regency F2450M – 2.3g /hr.
"This manual describes the installation and operation of the Regency F2450M wood heater. This heater meets the 2020 U.S. Environmental Protec-
tion Agency’s cord wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates rang-
ing from 14,200 BTU/hr to 53,600 BTU/hr. Efficiency is determined using the B415 method resulting in lower and higher heat values. This heater
generates the best efficiency when operated using well-seasoned wood and installed in the main living areas where the majority of the chimney is
within the building envelope. "This wood heater needs periodic inspection and repair for proper operation.
It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual."
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL, PLASTIC,GARBAGE,
SULPHUR OR OIL MAY DAMAGE THE STOVE.
"This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hard-
woods, as compared to softwoods or to green or freshly cut hardwoods."
DO NOT BURN:
Treated wood
Lawn clippings or yard waste Manure or animal remains
• Coal
Materials containing rubber including tires Saltwater driftwood or other previously salt
water saturated materials
• Garbage
Materials containing plastic Unseasoned wood
• Cardboard
Waste petroleum products , paints or paint thinners or asphalt
products
Paper products, cardboard, plywood or par-
ticle board. The prohibition against burning
these materials does not prohibit the use
of fire starters made from paper, cardboard,
saw dust, wax and similar substances for the
purpose of starting a fire in a wood heater.
• Solvents
Materials containing asbestos
• Colored Paper
Construction or demolition debris
Trash
Railroad ties
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be con-
sulted before installation to determine the need to obtain a permit.
This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or UL-
103HT in the United States of America. or code approved masonry chimney with flue liner.
F2450M is tested and certified to ULC-S627-00 and UL1482-2011 (R2015).
SAVE THESE INSTRUCTIONS
F2450M Regency Freestanding Woodstove | 3
table of contents
Safety Label for F2450M ................................................... 4
Dimensions
Unit Dimensions ................................................................ 5
Outside Air Dimensions ..................................................... 5
Installation
Modular installation options ............................................... 6
Stove Assembly Prior To Installation .................................. 7
Airmate Assembly for F2450M .......................................... 7
Rear Heat Deflector Assembly for F2450M ....................... 7
Side Shield Adjustment ..................................................... 7
Pedestal Assembly Installation .......................................... 8
Logo Installation ................................................................ 8
Bottom Heat Shield and Legs Installation .......................... 8
Room Air - Important ......................................................... 9
Minimum Clearance To Combustible Materials .................. 9
Minimum Alcove Clearance and Clearance
to Combustible Materials ................................................. 10
Floor Protection ............................................................... 10
Step By Step Chimney And Connector Installation ......... 12
Masonry Chimney............................................................ 13
Masonry Fireplace ........................................................... 13
Factory Built Chimney...................................................... 13
Combustible Wall Chimney Connector Pass-throughs .... 14
Mobile Home Installation ................................................. 15
Mobile Home Kit for Canada ........................................... 16
Installing Outside Air from Pedestal Base ....................... 17
Installing Outside Air Using Bottom Heat Shield/Legs ..... 17
Recommended Heights For Woodstove Flue .................. 18
Optional Outside Air Kit .................................................. 19
Brick Installation .............................................................. 20
Wood Handle & Door Assembly ...................................... 21
Flue Baffle & Secondary Air Tube Installation .............22
Fan Installation ...........................................................23
Stainless Steel Smoke Deflector Installation ...............24
Seasoned Firewood .....................................................25
Operation
Operating Instructions .................................................25
Draft Control ................................................................25
First Fire ......................................................................26
Fan Operation ..............................................................27
Ash Disposal ................................................................27
Ash Drawer Operating Guidelines ...............................27
Safety Guidelines and Warnings .................................27
Maintenance
Classic Door Handle Replacement ..............................28
Glass Replacement .....................................................28
Maintenance ................................................................29
Creosote ......................................................................29
Ways to Prevent and Keep Unit Free of Creosote .......29
Door Gasket ................................................................29
Glass Maintenance ......................................................29
Wood Storage ..............................................................29
Secondary Air Tube Removal / Installation ..................30
Annual Maintenance ....................................................30
Vertical Stainless Deflector Replacement....................31
Parts
Main Assembly ............................................................32
Bases ...........................................................................34
Warranty
Warranty ......................................................................36
CAUTION: To avoid burns or wood splinters, when opening/closing the fuel
door or adding wood to the fire, You should always wear appropriate protective
gloves to protect your hands from the heat being emitted from this fireplace.
4 | F2450M Regency Freestanding Woodstove
safety decal
This is a copy of the label that accompanies each
Regency Freestanding Woodstove (F2450M).
We have printed a copy of the contents here
for your review.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
Part #: 920-037a
Size: 6.53" H x 10.8" W (File at 100%)
Color: black on grey except for the items indicated as being printed in red.
Mar. 16/17: Created decal
June 06/18: Updated decal
July16/18: Updated decal w/EPA info
July 19/18: Updated decal
Nov.22/18: Updated Floor protection dim.
Mar 06/19: Updated clearances + standards
Oct 07/19: Updated to mobile homes in Canada and the United States
duplicate serial number
MINIMUM ALCOVE CEILING HEIGHT: 2109 MM / 83" MAXIMUM ALCOVE DEPTH 1219 MM / 48".
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 405 MM / 16"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
C
B
D
A
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH
FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY CLOSED. IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR
TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY
FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND
SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN PART #075-917, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT
IN CANADA: LISTED ULCS 629 CHIMNEY. USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION/INSTRUCTIONS
IN USA: LISTED UL 103 HT CHIMNEY
HAUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2109 MM / 83 PO PROFONDEUR MAXIMALE DE L’ALCÔVE : 1219 MM / 48 PO
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 405 MM / 16 PO.
L’ESPACE SOUS LE POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
À UTILISER AVEC DU BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE. NE PAS OBSTRUER LES OUVERTURES
D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR SEULEMENT LA PORTE DE CHARGEMENT POUR ALIMENTER LE FEU. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER
LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, RISQUE DE SURCHAUFFAGE. INSPECTER
ET NETTOYER FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR. DANS CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDER LES MEUBLES ET
AUTRES MATÉRIAUX COMBUSTIBLES ÉLOIGNÉS DU POÊLE. REMPLACER LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON
COMBUSTIBLES DÉPASSANT SUR LE DESSOUS, LE DEVANT ET LES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR PIÈCE N
o
075-917, ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.
DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT D'EFFECTUER L’ENTRETIEN DU POÊLE. NE PAS INSTALLER LE CORDON ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR.
AU CANADA : CHEMINÉE HOMOLOGUÉE ULCS 629. UTILISER LES PIÈCES DE LA CHEMINÉE TEL QUE SPÉCIFIÉ DANS LES CONSIGNES D’INSTALLATION.
AUX ÉTATS-UNIS : CHEMINÉE HOMOLOGUÉE UL103HT.
512
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
ATTENTION
CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS.
ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES.
LE CONTACT PEUT CAUSER DES BRÛLURES.
LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS
MADE IN CANADA / FABRIQUÉ AU CANADA
MANUFACTURED BY/ FABRIQUÉ PAR :
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION /
APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ
À COMBUSTIBLE SOLIDE, CONVENANT AUSSI
POUR INSTALLATION DANS UNE MAISON MOBILE
FLOOR PROTECTION*
PROTECTION DE PLANCHER*
*
Au Canada, la protection de plancher doit dépasser de 18 po (457 mm)
à l’avant (16 po aux États-Unis) et de 8 po (200 mm) de chaque côté du
poêle et derrière le poêle.
* In Canada, floor protection must extend 18" (457mm) to the front (16"
for USA) and 8" (203mm) to each side and back of the stove.
DO NOT REMOVE THIS LABEL/
NE RETIREZ PAS CETTE ÉTIQUETTE
512
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT FACTORY-BUILT
CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS
CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALLER ET UTILISER SEULEMENT SELON LES CONSIGNES D’INSTALLATION ET D’UTILISATION DU FABRICANT. CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-
INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE MINIMAL DE 150
MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFA-BRIQUÉE HOMOLOGUÉE UL103 HT CONÇUE POUR ÊTRE UTILISÉE AVEC DES COMBUSTIBLES
SOLIDES OU UNE CHEMINÉE EN MAÇONNERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS D'INSTALLATION D'UNE CHEMINÉE TRAVERSANT UN MUR OU UN PLAFOND
EN MATÉRIAUX COMBUSTIBLES. NE PAS FAIRE TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE PAS RACCORDER CE POÊLE
À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
920-037a
MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2450M
TESTED TO: ULC S627-00 / UL 1482-2011 (R2015)
A 1245 mm / 49 in (Canada)
A 1194mm / 47 in (USA)
B 457 mm / 18 in
B 406 mm / 16 in
C 856 mm / 33-11/16 in
D 203 mm / 8 in
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
DATE OF MANUFACTURE
2019 2021 2022 20232020
0219WS026S
WARNING: ONLY USE LISTED REGENCY OPTIONS SUCH AS LEGS, AIRMATE, FAN AS SHOWN IN THE INSTALLATION MANUAL.
CAUTION: BURNING OF MATERIALS OTHER THAN SPECIFIED MAY CAUSE DAMAGE TO THE UNIT.
CAUTION: MOVING PARTS MAY CAUSE INJURY.
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using cord wood.Tested to ASTM E3053. Model Regency
F2450M – 2.3g /hr. This wood heater needs periodic inspection and repair for proper operation. Consult the owner's manual for further information. It is against federal regu-
lations to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual.
Certifié conforme aux normes 2020 du U.S. ENVIRONMENTAL PROTECTION AGENCY en matière d'émission de particules de bois en utilisant le bois de corde. Approuvé
ASTM E3053. Modèle Regency F2450M – 2,3 g /h. Cet appareil de chauffage au bois doit être inspecté périodiquement et réparé pour fonctionner correctement. Consulter
le manuel d’installation pour plus d’information. La réglementation fédérale interdit de faire fonctionner un tel appareil si les consignes d'utilisation contenues dans le présent
manuel ne sont pas respectées.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
DÉGAGEMENTS MINIMAUX PAR RAPPORT AUX MATÉRIAUX COMBUSTIBLES
F2450M WITH AIRMATE SHIELD F2450M WITH REAR DEFLECTOR
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
MEASURE FLUE
FROM HEATER CENTER-LINE
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL A 406 mm / 16 in D 711 mm / 28 in
BACKWALL B 292 mm / 11.5 in E 457 mm / 18 in
CORNER C 203 mm / 8 in F 508 mm / 20 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL A 381 mm / 15 in D 686 mm / 27 in
BACKWALL B 254 mm / 10 in E 419 mm / 16.5 in
CORNER C 152 mm / 6 in F 457 mm / 18 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL A 381 mm / 15 in D 686 mm / 27 in
BACKWALL B 254 mm / 10 in E 419 mm / 16.5 in
CORNER C 152 mm / 6 in F 457 mm / 18 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL A 406 mm / 16 in D 711 mm / 28 in
BACKWALL B 241 mm / 9.5 in E 406 mm / 16 in
CORNER C 203 mm / 8 in F 508 mm / 20 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL A 381 mm / 15 in D 686 mm / 27 in
BACKWALL B 203 mm / 8 in E 368 mm / 14.5 in
CORNER C 152 mm / 6 in F 457 mm / 18 in
SIDEWALL A 381 mm / 15 in D 686 mm / 27 in
BACKWALL B 203 mm / 8 in E 368 mm / 14.5 in
CORNER C 152 mm / 6 in F 457 mm / 18 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL G 380 mm / 15 in I 686 mm / 27 in
BACKWALL H 254 mm / 10 in J 419 mm / 16.5 in
MEASURE FLUE
FROM HEATER CENTER-LINE
SIDEWALL G 380 mm / 15 in I 686 mm / 27 in
BACKWALL H 203 mm / 8 in J 368 mm / 14.5 in
This appliance is approved for mobile home installations in Canada and the USA.
Cet appareil est homologué pour être installé dans une maison mobile au Canada et aux États-Unis.
AVERTISSEMENT : UTILISER SEULEMENT LES OPTIONS HOMOLOGUÉES PAR REGENCY COMME LES PATTES, LE DIFFUSEUR AIRMATE, LE VENTILATEUR COMME ILLUTRÉ DANE LE MANUEL D'INSTALLATION.
ATTENTION :
COMBUSTION DE TOUT MATÉRIAU NON SPÉCIFIÉ PEUT ENDOMMAGER L'APPAREIL.
ATTENTION : LE DÉPLACEMENT DES PIÈCES PEUT ENTRAÎNER DES BLESSURES.
COMBUSTION DE TOUT MATÉRIAU NON SPÉCIFIÉ PEUT ENDOMMAGER L'APPAREIL.
F2450M Regency Freestanding Woodstove | 5
dimensions
Unit Dimensions
Outside Air Dimensions
24"
610mm
32
3
16
"
817mm
34
5
8
"
879mm
27
1
8
"
690mm
24
13
16
"
630mm
6
7
16
"
163mm
33
7
8
"
860mm
31
7
16
"
798mm
7
13
16
"
198mm
21-1/4"
[540mm]
21-1/2"
[546mm]
23-1/8"
[587mm]
(from fuel door opening)
Rear
Front
Rear
4-9/16" (115mm)
6-13/16"(173mm)
Images for OUTSIDE AIR DIMENSIONS
Rear
Front
Rear
4-9/16" (115mm)
6-13/16"(173mm)
Images for OUTSIDE AIR DIMENSIONS
6 | F2450M Regency Freestanding Woodstove
installation
1. Please read this entire manual before you install
and use your new woodstove. Failure to follow
instructions may result in property damage,
bodily injury or even death. Be aware that local
Codes and Regulations may override some
items in this manual. Check with your local
inspector.
2. Select a position for your Regency Stove. Consult
the minimum clearance chart for your model
and set the stove in place. For installation use
listed double wall connector systems only.
3. To insure vertical alignment, suspend a plumb
bob from the ceiling over the exact center of
your stove flue and mark a spot on the ceiling
to indicate the center of the chimney.
4. Check that the area above the ceiling is clear
for cutting. Re-confirm the clearance from the
stove to combustibles to ensure that they are
within the prescribed limits.
5. This woodstove must be connected to a UL
103 HT (ULC S629) listed chimney or a code
approved masonry chimney with a flue liner.
Space heater is to be connected to a factory
built chimney conforming to CAN/ULC-5629
standard for 650C factory built chimneys. The
chimney requirement is 6", refer to appropriate
sections in this manual for specifics.
6. Install chimney according to chimney manu-
facturers instructions. The performance of your
woodstove is governed to a very large part by
the chimney system. Too short a chimney can
cause difficult start-up, dirty glass, back smok-
ing when door is open, and even reduced heat
output.
Too tall a chimney may prompt excessive draft
which can result in very short burn times and
excessive heat output. The use of an inexpensive
flue pipe damper may be helpful in reducing
excessive draft.
CAUTION: The chimney should be the same size
as the 6" flue outlet on the stove. The chimney
must be listed as suitable for use with solid fuels.
For other types of chimneys check with your
local building code officials. Do not confuse a
chimney with a type “B” Venting System used for
gas appliances as suitable for a wood burning
appliance. For Mobile Home installations refer
to that section within this manual.
7. Mark the location of the pedestal base or legs
on the floor, then move the stove aside and
mark the position of the floor protector.
8. The floor protector must be of non-combustible
material and must extend 16" (406mm) (USA
)in front of the door opening and 8" (203mm)
to the sides and rear of the unit. Some areas
may require a larger size floor protector. See
your local inspector. For outside air installation
refer to Mobile Home installation instructions
within this manual.
11. For residential installations 6" (single wall OK)
double wall chimney, the chimney connector
must be at least 24 gauge steel. Do not use
galvanized pipe. For Mobile Home installation
refer to the Mobile Home installation instructions
within this manual.
12. DO NOT CONNECT THIS UNIT TO A CHIM-
NEY SERVING ANOTHER APPLIANCE.
13. A chimney connector cannot pass through an
attic or roof space, closet or similar concealed
space, or a floor, ceiling, wall or partition of
combustible construction. In Canada, if pas-
sage through a wall, or partition of combustible
construction is desired, the installation shall
conform to CAN/CSA-B365, Installation Code
for Solid-Fuel-Burning Appliances and Equip-
ment.
14. Your Regency Woodstove is not to be con-
nected to any air distribution duct.
CAUTION:
Do not alter or makeshift chimney or install.
Install as per Manual.
NOTE: In Canada, floor protection
must extend 18" (450mm)
to the front and 8" (203mm)
to each side and back of the
stove.
WHEN THIS ROOM HEATER IS NOT PROP-
ERLY INSTALLED, A HOUSE FIRE MAY
RESULT. TO REDUCE THE RISK OF FIRE,
FOLLOW THE INSTALLATION INSTRUC-
TIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIRE-
MENTS IN YOUR AREA.
Modular installation options
WARNING: ONLY USE SPECIFIED COMPONENTS.
The following items are required when assembling your Regency Stove. F2450M unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must
use the Airmate instead
Modular Part
See the Minimum Clearance to Combustible Materials chart in the Installation section of this manual
F2450M Airmate OR
Rear Heat Deflector
Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The Airmate pushes heat forward out into the room, the Rear
Heat Deflector deflects the heat upward. Refer to the Installation sections within this manual.
OPTIONS :
Blower/ Fan
Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove
Ash Drawer Kit
Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner (refer to Bottom Shield Ash Drawer Kit, Instal-
lation section)
Outside Air Kit
Allows outside combustion air to enter firebox
Bottom heat shield + legs
Used instead of pedestal
Pedestal
Used instead of heat shield and legs
9. When the floor protection is complete, position
the stove with the flue collar centered under the
installed chimney.
10. In areas with frequent seismic activity, Regency
recommends that your unit is secured to the
floor by using the bolt down holes inside the
pedestal (the same ones used in Mobile Home
installations).
IMPORTANT:
During the first few fires, a white film may de-
velop on the glass front as part of the curing
process. The glass should be cleaned or
the film will bake on and become very difficult
to remove. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.
F2450M Regency Freestanding Woodstove | 7
installation
Side View
Rear Heat Deflector
Screws
Diagram 2
Diagram 3
Stove Assembly
Prior to Installation
The F2450M unit requires the pedestal (or heat
shield and legs) to be attached to the base. The
F2450M stove requires either the Airmate or Rear
Heat Deflector on top of the stove. Clearances to
combustible materials vary depending on whether
the Airmate or rear heat deflector is installed, so
be sure to check the Minimum Clearances, Instal-
lation section.
Rear Heat Deflector
Assembly for F2450M
The rear heat deflector is supplied with the stove
and must be installed unless the optional Airmate
has been selected. It stops the heat radiated from
the flue collar from overheating the rear wall. The
rear heat deflector is installed on top of the rear
heat shield, as shown in Diagram 4.
Side Shield Adjustment
The left and right side shields are lowered for ship-
ping and handling. It allows for a handhold on the
top of the stove. Before placing the stove in its final
position, the side shields must be raised.
Loosen the screws on the rear on the stove (3 per
side), slide the side panel up as far as possible and
then secure by tightening the screws.
Airmate
Rear Heat
Shield
Side Shield
Stove
Diagram 1
Diagram 4
Diagram 5
Airmate Assembly for F2450M
1. The Airmate sits on top of the stove with the slots
in the sides fitting over the curved deflector on
the rear stove top. See diagram 1. Discard the
Rear Heat Deflector that is supplied with the
unit, it is not required if the Airmate is installed.
2. Center the Airmate and push it forward to the
front of the stove. The back of the Airmate should
be level with the back and sides of the rear heat
shield. See Diagrams 2 & 3.
8 | F2450M Regency Freestanding Woodstove
installation
F2450
920-167 12.10.19
Shown with Classic door
1. For easier assembly, tip the stove on its back (onto a soft
surface to prevent scratching) and remove the front cover.
Hint: If you have chosen the Ash Drawer option, remove
the ash dump cover plates before attaching the pedestal
(refer to the Ash drawer Kit Installation section).
2. Important: Remove the blanking plate if:
a) you are not installing outside combustion air or
b) outside air is to be brought in from the rear of the stove
(see below).
3. Using the 4 supplied 5/16" bolts in the under-side of the
stove, insert the bolts loosely onto the threads located at
all 4 corners at the base of the unit. Align the holes in the
corners of the pedestal top with the corresponding bolts
in the base of the stove. Tighten each bolt from inside the
pedestal.
1. Push the Regency logo into
the two holes in the front
bottom left corner of
the pedestal cover
plate.
Note: Any paint touch up should be done prior to placing
logo on pedestal.
2. If not using ash drawer, then the front cover must remain
in place. If using ash drawer, then remove the front cover.
The instructions below apply to the painted cast leg. It will be
easier to attach the legs to the stove if the stove is tipped on its
back (preferably on a soft surface to prevent scratching). Ensure
to be extremely careful when tipping stove.
Important: Prior to installing the bottom heat shield, remove
the 4 inch blanking plate. See below.
This must be removed for combustion air to enter the ap-
pliance.
1. Remove the 4 bolts from underside of the base of the pedestal
and discard. Also remove cover plate and put to the side.
2. Line up the heat shield with the bottom of the unit.
3. Add bre washers and washers.
4. Start threading the bolt and washer (supplied with the bot-
tom shield) for about 1/4 of the way through the leg with the
washers being underneath the legs. Ensure that the legs
are properly aligned with heat shield and tighten the bolts.
5. Level the stove by adjusting the levelling bolts in the bottom
of each leg.
6. Reinstall cover plate if not using ash drawer option.
7. Install logo plate onto heat shield by placing in 2 holes as
shown in diagram.
If you are installing outside combustion air, bend the tabs out 90
degrees. Pipe fresh air into the bottom shield by using a minimum
4" duct pipe with a mesh grill at the outside termination. Attach
the pipe to the 2 tabs with screws.
Fibre
washer
Bottom Shield
Cover
Plate
Tabs
Spacer
Leg
Leveling
Bolt
Washer
Logo
Plate
Bolt
Screw
Blanking Plate
Fibre washer
Pedestal Assembly Installation
Bottom Heat Shield and Legs Installation
Logo Installation
F2450M Regency Freestanding Woodstove | 9
installation
Room Air Important
For installation using room air for combustion,
remove knockout from the pedestal, and/or from
the bottom if using a heat shield.
Mobile home installations require the use of
outside air.
Minimum Clearance To
Combustible Materials
Please read the section below carefully as clearances depend on whether the airmate or the rear
heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from
the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
Minimum ceiling height - 83" (2108mm)
On pedestal units there are two locations where
outside air may be adapted to the unit. If using
the bottom of the pedestal, do not remove knock-
out from the rear of the pedestal. Only remove
rear knockout if outside air will be brought in
from the rear.
On leg units outside air can only be brought in
from the bottom of the heat shield.
Note: Once the knockout is removed
there are two tabs remaining.
Bend both tabs out for ease of
installation when attaching out-
side air.
A
F
F
C
C
B E
D
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.
Residential Installation “C” Vent (Single Wall)
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2450M with Airmate
16" (406mm) 9.5" (241mm) 8" (203mm) 28" (711mm) 16" (406mm) 20" (508mm)
with Rear Deflector
16" (406mm) 11.5" (292mm) 8" (203mm) 28" (711mm) 18" (457mm) 20" (508mm)
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2450M with Airmate
15" (381mm) 8" (203mm) 6" (152mm) 27" (686mm) 14.5" (368mm) 18" (457mm)
with Rear Deflector
15" (381mm) 10" (254mm) 6" (152mm) 27" (686mm) 16.5" (419mm) 18" (457mm)
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2450M with Airmate
15" (381mm) 8" (203mm) 6" (152mm) 27" (686mm) 14.5" (368mm) 18" (457mm)
with Rear Deflector
15" (381mm) 10" (254mm) 6" (152mm) 27" (686mm) 16.5" (419mm) 18" (457mm)
10 | F2450M Regency Freestanding Woodstove
installation
Floor Protection
(Ember Protection only required)
A combustible floor must be protected by a non-combustible material (like tile, concrete board, or
certified to UL-1618 Type 1, or as defined by local codes).
Canada: Beneath the heater and extending to at least 18" on the fuel loading side and at least 8"
on the sides and back.
USA: Beneath the heater and extending to at least 16" beyond the fuel loading side and ash removal
opening and at least 8" on the sides and back and under the chimney connector extending 2"
beyond each side for horizontal applications.
Minimum Overall Depth (Y) of Floor Protector
Reference only when hearth pad is installed to
rear wall at minimum pipe clearances.
Hearth
Depth
Edge of Fuel door
opening to edge of
hearth
Hearth
Width
Edge of Fuel Door Opening
(Both Sides)
Residential Installation ''C'' Vent (Single Wall)
Unit
A B C D
F2450M with Airmate Canada 50-1/2" (1283mm) 18" (457mm) 33-11/16" (856mm) 8" (203mm)
USA 48-1/2" (1232mm) 16" (406mm) 33-11/16" (856mm) 8" (203mm)
F2450M with Rear
Deflector
Canada 52-1/2" (1334mm) 18" (457mm) 33-11/16" (856mm) 8" (203mm)
USA 50-1/2" (1283mm) 16" (406mm) 33-11/16" (856mm) 8" (203mm)
Residential Close Clearance (To be installed with required pipe components)
Unit
A B C D
F2450M with Airmate Canada 48" (1219mm) 18" (457mm) 33-11/16" (856mm) 8" (203mm)
USA 46" (1168mm) 16" (406mm) 33-11/16" (856mm) 8" (203mm)
F2450M with Rear
Deflector
Canada 50" (1270mm) 18" (457mm) 33-11/16" (856mm) 8" (203mm)
USA 48" (1219mm) 16" (406mm) 33-11/16" (856mm) 8" (203mm)
C
B
D
A
D
Minimum Alcove Clearance and Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 83"
Maximum depth of alcove - 48"
G
K
16"
H
J
I
NOTE: This clearance is also required for air space between the appliance and wall/ceiling. Where the
appliance is installed less than 8" from a rear wall, the ember pad only needs to extend to the base of
the wall based on the clearances noted in this manual.
Unit From Unit From Flue Center-Line From Wall
G H I J K
Medium F2450M with Airmate
15" (381mm) 8" (203mm) 27" (686mm) 14.5" (368mm) 54" (1372mm)
with Rear Deflector
15" (381mm) 10" (254mm) 27" (686mm) 16.5" (419mm) 54" (1372mm)
Minimum Overall Depth (Y) of Floor Protector
Edge of Fuel door
opening to edge of
hearth
Edge of Fuel Door
Opening (Both
Sides)
Unit
A
B
C
D
F2450M Canada 49" (1245mm) 18" (457mm) 33 11/16" (856 mm) 8" (203mm)
USA 47" (1194mm) 16" (406mm) 33 11/16" (856 mm) 8" (203mm)
F2450M Regency Freestanding Woodstove | 11
installation
Minimum Overall Depth (Y) of Floor Protector - Corner Hearth
Reference only when hearth pad is installed to rear wall at minimum pipe clearances.
Hearth Depth
F2450M L M N O
Residential Installation ''C'' Vent (Single Wall)
Canada 33-11/16" (856mm) 62-7/8" (1596mm) 52-1/8" (1324mm) 28-5/16" (727mm)
USA 33-11/16" (856mm) 60-7/8" (1545mm) 50-3/4" (1289mm) 26-7/8" (681mm)
Residential Close Clearance (To be installed with required pipe components)
Canada 33-11/16" (856mm) 60-1/16" (1527mm) 50-1/8" (1273mm) 26-5/16" (676mm)
USA 33-11/16" (856mm) 58-1/16" (1475mm) 48-3/4" (1238mm) 24-7/8" (610mm)
M
O
L
N
Z
16"
Y
X
for angled corners
6"
6"
W
W
Floor Protection (Corner Installation)
A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 8" (203mm) from each side and minimum 16"
(406mm)** from the front face of the stove and minimum 6"
(152mm)** (or the rear clearance to combustibles whichever
is smaller) from the rear of the stove.
When installed with horizontal venting, non-combustible floor
protection must beneath the flue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove F2450M 33-11/16" (856 mm)
**NOTE: In Canada, floor protection must extend 18" (450mm) to
the front and 8" (203mm) to back of the stove.
Minimum Overall Depth (Y) of Floor Protector
Unit Residential
"C" Vent
From Edge of Fuel Door
Opening
Y Z W
Medium F2450M
Canada - 49" (1245mm)
USA - 47" (1194mm)
**6" (152mm) 8" (203mm)
12 | F2450M Regency Freestanding Woodstove
installation
*
*
when using single
wall pipe
Minimum
18"
(457mm)
to
centerline
Horizontal Installation
Standard Ceiling Installation
8. To complete your chimney installation, install
the double wall connector pipe from the
stove’s flue collar to the chimney support
device.
9. If you are using a horizontal connector,
the chimney connector should be as high
as possible while still maintaining the 18"
(457mm) minimum distance from the hori-
zontal connector to the ceiling.
NOTE: Residential Close Clearance and
Alcove installations require a listed
double wall connector from the stove
collar to the ceiling level.
The diagrams below illustrate one way to install
your unit into a standard ceiling or with a horizon-
tal connector. Check with your dealer or installer
for information on other options available to you.
Step By Step
Chimney And
Connector
Installation
Note: These are a generic set of chim-
ney installation instructions.
Always follow the manufacturers
own instructions explicitly. Check
the Minimum Recommended Flue
Heights section (Table 1).
1. With your location already established, cut
and frame the roof hole. It is recommended
that no ceiling support member be cut for
chimney and support box installation. If it is
necessary to cut them, the members must
be made structurally sound.
2. Install radiant shield and support from above.
3. Stack the insulated pipe onto your finish
support to a minimum height of 3 feet above
the roof penetration, or 2 feet above any
point within 10 feet measured horizontally.
There must be at least 3 feet of chimney
above the roof level.
Note: Increasing the chimney height
above this minimum level will
sometimes help your unit to
“breathe” better by allowing
a greater draft to be created.
This greater draft can decrease
problems such as, difficult start-
ups, back-smoking when door is
open, and dirty glass. It might be
sufficient to initially try with the
minimum required height, and
then if problems do arise add
additional height at a later date.
4. Slide the roof flashing over your chimney
and seal the flashing to the roof with roofing
compound. Secure the flashing to your roof
with nails or screws.
5. Place the storm collar over the flashing,
sealing the joints with a silicone caulking.
6. Fasten the raincap with spark screens (if
required) to the top of your chimney.
7. For optimum efficiency when installing into a
masonry chimney, size accordingly, i.e. the
6" (152mm) flue diameter is 28.28 sq.in.
This stove may be connected to a lined masonry
chimney or a listed factory built chimney suitable for
use with solid fuels and conforming to ULC629 in
Canada or UL-103HT in the USA. Do not connect
it to a chimney serving another appliance. To do
so will affect the safe operation of both appliances,
and will void the stove warranty. You must comply
with the local authority having jurisdiction and/or
in Canada, CSA installation standard B365-M87.
The chimney connector must be 6" diameter, 24 MSG
Black/Blue steel. Do not use aluminum or galvanized
steel, they cannot properly withstand the extreme
temperatures of a wood fire. The chimney connector
between the stove and the chimney should be as
short and direct as possible.
The chimney connector must be attached to either
an approved masonry chimney or one of the listed
factory built chimneys suitable for use with solid
wood fuel. All joints must be tight and fastened with
sheet metal screws.
WARNING
THE CHIMNEY CONNECTOR IS
TO BE USED ONLY WITHIN THE
ROOM, BETWEEN THE STOVE
AND CEILING/ WALL. NEVER USE
A CHIMNEY CONNECTOR TO PASS
THROUGH AN ATTIC OR ROOF
SPACE, CLOSET OR SIMILAR CON-
CEALED SPACE, OR A FLOOR, OR
CEILING. AN EFFECTIVE VAPOR
BARRIER MUST BE MAINTAINED
AT THE LOCATION WHERE THE
CHIMNEY OR COMPONENT PENE-
TRATES TO THE EXTERIOR OF THE
STRUCTURE. ALWAYS MAINTAIN
THE MINIMUM CLEARANCES TO
COMBUSTIBLES AS REQUIRED
BY THE APPLICABLE BUILDING
CODES.
F2450M Regency Freestanding Woodstove | 13
installation
Factory Built Chimney
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the
ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other
obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629,
Standard for 650
0
C Factory-Built Chimneys.
Masonry
Chimney
Ensure that a masonry chimney meets the mini-
mum standards of the National Fire Protection
Association (NFPA) by having it inspected by
a professional. Make sure there are no cracks,
loose mortar or other signs of deterioration and
blockage. Have the chimney cleaned before the
stove is installed and operated. When connect-
ing the stove through a combustible wall to a
masonry chimney, special methods are needed.
Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.
Masonry
Fireplace
There are listed kits available to connect a stove
to a masonry fireplace. The kit is an adapter
that is installed at the location of the fireplace
damper. The existing damper may have to be
removed to allow installation.
Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.
This unit is designed to use either a 5.5" (140mm)
or 6" (152mm) flue liner only in the confines of
the masonry chimney as shown.
Minimum 18" (457mm)
to centerline
Minimum
18"
(457mm
)
to
centerline
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.
14 | F2450M Regency Freestanding Woodstove
installation
Method A: 12" (304.8 mm) Clearance to Combustible Wall Member:
Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm)
minimum wall thickness clay liner, construct a wall pass-through.
The clay liner must conform to ASTM C315 (Standard Specification
for Clay Fire Linings) or its equivalent. Keep a minimum of 12" (304.8
mm) of brick masonry between the clay liner and wall combustibles.
The clay liner shall run from the brick masonry outer surface to the
inner surface of the chimney flue liner but not past the inner surface.
Firmly grout or cement the clay liner in place to the chimney flue liner.
Method B: 9" (228.6 mm) Clearance to Combustible Wall Member:
Using a 6" (152.4 mm) inside diameter, listed, factory-built Solid-Pak
chimney section with insulation of 1" (25.4 mm) or more, build a wall
pass-through with a minimum 9" (228.6 mm) air space between the
outer wall of the chimney length and wall combustibles. Use sheet metal
supports fastened securely to wall surfaces on all sides, to maintain the
9" (228.6 mm) air space. When fastening supports to chimney length,
do not penetrate the chimney liner (the inside wall of the Solid-Pak
chimney). The inner end of the Solid-Pak chimney section shall be
flush with the inside of the masonry chimney flue, and sealed with a
non-water soluble refractory cement. Use this cement to also seal to
the brick masonry penetration.
Minimum
12 in. (304.8mm)
to combustibles
Masonry chimney
Chimney Flue
Minimum chimney clearance to brick
and combustibles 2 in. (50.8mm)
Minimum clearance
12 in. (304.8mm)
of brick
Chimney
connector
Fire clay
liner
Method C: 6" (152.4 mm) Clearance to Combustible Wall Member:
Starting with a minimum 24 gage (.024" [.61 mm]) 6" (152.4 mm) metal
chimney connector, and a minimum 24 gage ventilated wall thimble
which has two air channels of 1" (25.4 mm) each, construct a wall
pass-through. There shall be a minimum 6" (152.4 mm) separation
area containing fiberglass insulation, from the outer surface of the wall
thimble to wall combustibles. Support the wall thimble, and cover its
opening with a 24-gage minimum sheet metal support. Maintain the
6" (152.4 mm) space. There should also be a support sized to fit and
hold the metal chimney connector. See that the supports are fastened
securely to wall surfaces on all sides. Make sure fasteners used to
secure the metal chimney connector do not penetrate chimney flue liner.
Method D: 2" (50.8 mm) Clearance to Combustible Wall Member:
Start with a solid-pak listed factory built chimney section at least 12"
(304 mm) long, with insulation of 1" (25.4 mm) or more, and an inside
diameter of 6" (2 inches [51 mm] larger than the 6" [152.4 mm] chimney
connector). Use this as a pass-through for a minimum 24-gage single
wall steel chimney connector. Keep solid-pak section concentric with
and spaced 1" (25.4 mm) off the chimney connector by way of sheet
metal support plates at both ends of chimney section. Cover opening
with and support chimney section on both sides with 24 gage minimum
sheet metal supports. See that the supports are fastened securely to
wall surfaces on all sides. Make sure fasteners used to secure the
metal chimney connector do not penetrate chimney flue liner.
Combustible Wall Chimney Connector Pass-throughs
F2450M Regency Freestanding Woodstove | 15
installation
Pedestal
Bolted to
Floor
Outside Air
Mobile Home Installation
Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8, a
supply of fresh air has to be supplied to your unit.
See Optional Outside Air Kit instructions in this
manual.
Place your unit in position and secure it to the floor
using two lag bolts 3/8" (10mm) x 3-1/2" (89mm)
through the two holes inside the pedestal base.
It is important to maintain the structural integrity
of the Mobile Home floor, walls and roof when
installing your unit.
For Mobile Home units installed in the U.S. the unit
must be grounded using a #8 ground wire with
approved termination and star washer.
In addition to standard installation instructions the
following requirements are mandatory for installation
in a mobile home.
1. The stove must be permanently bolted to
the floor of the Mobile Home using the floor
screws provided.
2. The stove must have a permanent outside air
source for combustion.
3. The stove must be electrically grounded to the
steel chassis of the Mobile Home.
4. A listed double-wall connector chimney system,
roof thimble, spark arrestor and roof flashing kit
suitable for use in Mobile Homes must be used.
5. If the chimney exits the Mobile Home at a location
other than through the roof, and exits at a point
7ft. (2130mm) or less above the ground level on
which the Mobile Home is positioned a guard or
method of enclosing the chimney shall be fitted at
the point of exit for a height up to 7ft. (2130mm).
6. The chimney shall be attached directly to the room
heater and shall extend at least 3 ft. (914mm)
above the part of the roof through which it passes.
The top of the chimney should project at least
2ft. (610mm) above the highest elevation of any
part of the Mobile Home within 10 ft. (3048mm)
of the chimney.
7. The chimney system shall comply with Local
Requirements.
8. Any openings in a chimney guard where required
must not permit the entrance of 3/4" (19mm)
diameter rod.
9. CAUTION: THE STRUCTURAL INTEGRITY OF
THE MOBILE HOME ROOF, FLOOR, WALLS
AND CEILING MUST BE MAINTAINED.
10. Check any other local building code as other
local codes may apply.
11. WARNING: DO NOT INSTALL IN A SLEEPING
ROOM OF A MOBILE HOME.
12. Use silicone to create an effective vapour barrier
at the location where the chimney or other com-
ponent penetrates to the exterior of the structure.
CAUTION: At no time use unlabelled
parts, or substitute parts made for another
chimney system.
Install as per chimney manufacturer's
installation instructions.
For Canadian Installations : see Outside Air
Kit - Part # 846-502.
There are further requirements when installing
this unit into a mobile home in Canada only.
WARNING: Operate only with door fully
closed - open feed door to feed fire only.
1. Identify the position of the outside air damper by the orientation of the metal handle that rests outside
the galvanized pipe. The metal handle and the damper disc are in line with each other. This means
that if the metal handle is in a horizontal position, the damper is flat and fully open.
2. Open the damper fully whenever you start a fire. This will allow the outside air to be drawn in the
pedestal base eliminating any potential smoke escaping the stove and entering the room. (Negative
air pressure)
16 | F2450M Regency Freestanding Woodstove
installation
Mobile Home Kit - for Canada
Note: The optional ashdrawer cannot be used when using the Mobile Home Kit.
920-167
28.10.19
F2450
Mobile Home Kit - For Canada
Note: The optional ash drawer cannot be used when using the Mobile Home Kit.
3.
Remove the 4" knock out from the rear pedestal.
4.
Install rear collar to the rear pedestal using 4 screws.
Page 1 of 1 075-500.SLDASM 12/19/2016
Mobile Home Box
Pedestal Stove
Collar
Flex
The Mobile Home kit contains:
1 Bottom metal cover - only used when air is drawn from the floor.
1 Flex
1 Collar
1 Mobile home box
1 Square transition box (used when installing bottom heat shield/
legs)
Screws
5. Attach flex to rear pedestal using supplied screws or the 4" clamp.
6. Bring pedestal base near the base of the firebox and secure flex
to the Mobile Home box.
7. Secure pedestal base and Mobile Home Box to firebox as shown
in diagram 3 using the screws that were previously removed/
loosened in step 1. See pedestal instructions.The Mobile Home
Box and firebox use the same screws.
Diagram 4
8. Install blanking plate to the front of the pedestal with 4 screws.
1.
Lay unit on its back. Remove two front 7/16 bolts. Loosen rear
two 7/16" bolts. See diagram 1.
  
Install rear collar
to the rear pedes-
tal using 4 screws.
Diagram 2
Diagram 3
4 screws
Diagram 5
9. Place unit into position and install the mandatory outside air kit.
See «Mobile Home installation» section in this manual.
Blanking
plate
2.
If using outside air from the rear of the pedestal, follow instruc-
tions noted below. If using outside air from the pedestal base,
follow instructions from step 10 to 16. For bottom heat shield/
legs, follow instructions from step 17 to 22. The Mobile Home Box
is always mounted in between the firebox and pedestal or bottom
heat shield.
Diagram 1
F2450M Regency Freestanding Woodstove | 17
installation
920-167 12.10.19
If installing outside air from pedestal base, do not remove knock
out from rear of pedestal. This must remain in place.
Page 1 of 1 075-500.SLDASM 12/19/2016
Mobile Home Box
Flex
Bottom Metal Cover
Collar
Pedestal Base
10. Secure collar to base of unit with 4 screws.
11. Install bottom metal cover over collar installed in step 10 and
rest cover on pedestal base.
12. Secure flex to collar with supplied screws or the 4" clamp.
13. Bring pedestal base near the base of the firebox and secure flex
to mobile home box with supplied screws.
14. Secure Mobile Home Box and pedestal to the firebox base
using the screws that were previously removed in step 1. See
pedestal instructions.
15. Install blanking plate to the front of the pedestal with 4 screws.
Use picture from step 8.
16. Install the mandatory outside air kit. See «Mobile Home Instal-
lation» section in this manual. Place unit into its final position
to complete install.
Installing Outside Air Using Bottom Heat
Shield/Legs
Page 1 of 1 075-500.SLDASM 12/19/2016
Mobile Home Box
Square Transition Box
Collar
Bottom Heat Shield
Cast legs
Knock out
Blanking plate
17. Remove knock out from the bottom heat shield and bend tabs left
over when the knock out was removed to the side.
18. Secure collar to base of bottom heat shield as shown with 4 screws.
19. Secure transition box on top of round collar installed in step 18
and secure with 3 screws.
20. Install blanking plate if not already installed.
21. Secure Mobile Home Box and bottom heat shield. See bottom
heat shield/leg instructions.
22. Install the mandatory outside air kit. See «Mobile Home Instal-
lation» section in this manual. Place unit into its final position to
complete install.
F2450
Installing Outside Air from Pedestal Base
18 | F2450M Regency Freestanding Woodstove
installation
Recommended Heights For Woodstove Flue
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12' straight.
2) Add the following vertical height to compensate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T" = 3 ft.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea level.
Example: a)
1-1/2 ft. of horizontal run = 3 ft.
one "T" = 3 ft.
Total Addition (at sea level) = 6 ft.
Example: b)
One 90 deg. elbow = 2 ft.
2 ft. of horizontal run = 4 ft.
one "T" = 3 ft.
Total Addition (at sea level) = 9 ft.
Recommended Flue Height
Elevation Example a) Example b)
0' 18' 21'
1000' 18.72' 21.84'
2000' 19.44' 22.68'
5000' 21.60' 25.20'
8000' 23.76' 27.72'
TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
# OF ELBOWS
ELEVATION (FT)
ABOVE SEA LEVEL 0 2 x 15
o
4 x 15
o
2 x 30
o
4 x 30
o
2 x 45
o
4 x 45
o
0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0
1000-2000 12.5 13.5 14.5 15.5 19.0 16.5 21.0
2000-3000 13.0 14.0 15.0 16.0 19.5 17.0 21.5
3000-4000 13.5 14.5 15.5 17.0 20.0 18.0 22.5
4000-5000 14.0 15.0 16.0 17.5 21.0 18.5 23.0
5000-6000 14.5 15.5 17.0 18.0 21.5 19.0 24.0
6000-7000 15.0 16.0 17.5 18.5 22.5 20.0 25.0
7000-8000 15.5 16.5 18.0 19.0 23.0 20.5 25.5
8000-9000 16.0 17.0 18.5 20.0 24.0 21.0 26.5
9000-10000 16.5 17.5 19.0 20.5 24.5 22.0 27.0
NOTE: No more than two offsets (four elbows) allowed. Two 45
o
elbows equal one 90
o
elbow.
WARNING:
DO NOT INSTALL IN SLEEPING
ROOM
CAUTION: The structural integrity of the mobile home
floor, wall and ceiling/roof must be maintained.
Draft is the force which moves air from the appliance
up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local
geography, nearby obstructions and other factors.
Too much draft may cause excessive temperatures
in the appliance and may cause damage. An un-
controllable burn or excessive temperature indicates
excessive draft. Inadequate draft may cause back
puffing into the room and plugging of the chimney.
Inadequate draft will cause the appliance to leak
smoke into the room through appliance and chim-
ney connector joints. Ensure the heater is installed
in areas that are not too close to neighbors or in
valleys that would cause unhealthy air quality or
nuisance conditions.
F2450M Regency Freestanding Woodstove | 19
installation
The Outside Air Kit is an option for Freestanding Stoves. Outside air for combustion can be brought in either through the bottom of the pedestal or
through the rear plate of the pedestal.
For both bottom and rear outside air the Pedestal Cover Plate must be installed. Loosen the 4 screws on the rear of the pedestal and slide the cover
plate over them. Slide the plate to the left to center it and tighten down the 4 screws.
Rear View
Completed Install
Side View
Outside Air Through Pedestal Bottom
Mark the position of your unit as outlined in the "General Information"
and "Clearances to Combustibles" section of the manual. Pipe fresh
air into the pedestal area by using a minimum 4" duct pipe with a
mesh grill at the outside termination.
Outside Air Through Pedestal Rear
Remove the blanking plate from the rear of the pedestal and bend
the two tabs out 90 degrees. Pipe fresh air into the pedestal area
by using a minimum 4" metallic duct pipe with a mesh grill at the
outside termination.
Fasten the pipe to the cover plate using the tabs and 2 screws.
Damper Installation
NOTE: The damper cannot be installed if attaching outside air to the
bottom of the appliance.
Supplied damper allows the combustion air to be closed off when unit
is not in operation.
Install the damper within the round pipe in an easily accessible location.
1. Drill a 5/16" hole in the desired location.
2. Insert damper with threaded section out.
3. Install damper handle and secure with wing nut.
Wing nut
Damper handle
Damper
Optional Outside Air Kit
20 | F2450M Regency Freestanding Woodstove
installation
Brick Installation
Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not
become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the diagram below and place in their correct positions.
Do not use a grate.
NOTE: The "AD" brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed (refer
to the Listed Components for Mobile Home Installation section).
LyTherm sheet
Order of firebrick install:
a) Rear Firebrick
b) Firebox floor - install brick over LyTherm Sheet
c) Right and left side Firebricks
70
AD
70
70
70
74
72
72
76
70) Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9"
72) Brick Partial: 1-1/4" x 2" x 4-1/2"
74) Brick Partial: 1-1/4" x 4-1/2" x 3-1/2"
76) Brick Partial: 1-1/4" x 2" x 9"
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Regency F2450 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues