Red Sea ReefATO+
16
strengths that are available to the controller from its current location.
Select your preferred network and wait a few moments while the
controller connects to it. The indicator LED will now be a solid red. Follow
the instructions on the app for initial settings.
If you have set the aquarium to Offline, select the “Direct Mode” option
at the top of the screen to skip the network connection. The indicator LED
will continue to blink as the controller Wi-Fi remains in AP mode.
Follow the instructions in the app for connecting the controller to the
ReefBeat App and cloud.
If you already have the pump, sensor and leak detector connected to the
Controller follow the instructions in the App for setting them up.
Setting up the ReefATO+
ATO Auto-Fill
When setting up the system the App will ask for the length of tube used
to connect the pump to the tube holder and the height from the bottom
of the pump to outlet of the tube holder. These values can be modified
later from: Homepage > ATO Settings > more settings, the length cannot
be smaller than the height. These values are used to automatically set
the appropriate pump speed for your installation and estimate the flow
rate that will be used in the top-off log and reservoir volume monitor.
The flow rate is only an approximation, if you want a more accurate
record you can measure the actual flow rate for your system and
update the App: Homepage > ATO Settings > more settings > Flow rate
adjustment.
Each ATO level/temperature sensor has a 3-digit temperature calibration
code (between 400 & 600) that needs to be entered to the App. The
code can be found on a label attached to the sensor cable.
By default, the Auto-fill operation of the system is switched off to allow
you to ensure that the sensor is properly in place and that there is water
in the reservoir before it is activated.
When you are ready, toggle the Auto-fill - ON.
ATO Reservoir Volume Monitor
The “Reservoir Volume Monitor” automatically deducts the amount of
water used for each fill from the last updated reservoir volume that you
entered. The ReefBeat will present the current volume in the reservoir
and will let you know 24 hours before it is due to run out. Whenever
you refill the reservoir, you will need to enter the new volume, so if
you do not plan on maintaining this feature it is best not to enable it.
The Monitor is only an approximate indication and has no effect on the
operation of the auto-fill. The controller detects when the reservoir has
actually run out of water by monitoring pump performance and will
switch off the auto-fill until you refill the reservoir and “resume” it.
ATO Quick Action Return Delay
The ReefATO+ can be connected to the ReefBeat Maintenance/
Emergency Quick-Action buttons. All devices that are configured for
these Quick-Actions will immediately shut down when they are enabled
and will resume immediately when they are switched off.
To delay the restart of the Auto-fill, set the Return Delay to the desired
number of minutes required for all other equipment to restart and water
levels in the sump to return to normal. Use this setting, for example, if
you want to check the water level in the sump after a water change to
allow the option to add some more salt water instead of having the ATO
automatically add RO water.