Tascam SERIES 8p Dyna Le manuel du propriétaire

Catégorie
Équipement musical supplémentaire
Taper
Le manuel du propriétaire
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
日本語
OWNER'S MANUAL
MODE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSANLEITUNG
MANUALE DI ISTRUZIONI
取扱説明書
D01359100D
SERIES 8p Dyna
MICROPHONE PREAMP
2 TASCAM SERIES 8p Dyna
• TASCAMisaregisteredtrademarkofTEACCorporation.
• Othercompanynames,productnamesandlogosinthis
documentarethetrademarksorregisteredtrademarksof
theirrespectiveowners.
TASCAM SERIES 8p Dyna 3
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
For U.S.A.
Supplier’s Declaration of Conformity
Model Number: SERIES 8p Dyna
Trade Name: TASCAM
Responsible party: TEAC AMERICA, INC.
Address: 10410 Pioneer Blvd., Unit #1, Santa Fe Springs,
California 90670, U.S.A
Telephone number: 1-323-726-0303
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may
cause undesired operation.
INFORMATION TO THE USER
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures.
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and
receiver.
c) Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician
for help.
CAUTION
Changes or modifications to this equipment not expressly
approved by TEAC CORPORATION for compliance could void
the users authority to operate this equipment.
For Canada
THIS CLASS B DIGITAL APPARATUS COMPLIES WITH CANADIAN
ICES-003.
CET APPAREIL NUMERIQUE DE LA CLASSE B EST CONFORME A
LA NORME NMB-003 DU CANADA.
This product complies with the European
Directives request and the other Commission
Regulations.
This product complies with applicable UK
regulations.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance
with the manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers)
that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
• The apparatus draws nominal non-operating power from the
AC outlet with its POWER or STANDBY/ON switch not in the
ON position.
• The mains plug is used as the disconnect device, the
disconnect device shall remain readily operable.
• Caution should be taken when using earphones or
headphones with the product because excessive sound
pressure (volume) from earphones or headphones can cause
hearing loss.
• If you are experiencing problems with this product, contact
TEAC for a service referral. Do not use the product until it has
been repaired.
OWNER’S MANUAL
4 TASCAM SERIES 8p Dyna
CAUTION
• Do not expose this apparatus to drips or splashes.
• Do not place any objects filled with liquids, such as vases,
on the apparatus.
• Do not install this apparatus in a confined space such as a
book case or similar unit.
• The apparatus should be located close enough to the AC
outlet so that you can easily grasp the power cord plug at
any time.
• If the product uses batteries (including a battery pack
or installed batteries), they should not be exposed to
sunshine, fire or excessive heat.
• CAUTION for products that use replaceable lithium
batteries: there is danger of explosion if a battery is
replaced with an incorrect type of battery. Replace only
with the same or equivalent type.
• Installed battery subjected to extremely low air pressure
may result in an explosion or the leakage of flammable
liquid or gas.
For European Customers
Disposal of electrical and electronic equipment
(a) All electrical and electronic equipment should be disposed
of separately from the municipal waste stream via
collection facilities designated by the government or local
authorities.
(b) By disposing of electrical and electronic equipment
correctly, you will help save valuable resources and
prevent any potential negative effects on human health
and the environment.
(c) Improper disposal of waste electrical and electronic
equipment can have serious effects on the environment
and human health because of the presence of hazardous
substances in the equipment.
(d) The Waste Electrical and Electronic Equipment
(WEEE) symbol, which shows a wheeled bin that
has been crossed out, indicates that electrical
and electronic equipment must be collected and
disposed of separately from household waste.
(e) Return and collection systems are available to end users.
For more detailed information about the disposal of old
electrical and electronic equipment, please contact your
city office, waste disposal service or the shop where you
purchased the equipment.
RACK-MOUNTING THE UNIT
Use the supplied rackmount screw kit to mount the unit in a
standard 19-inch rack, as shown below.
Remove the feet of the unit before mounting.
ATTENTION
i Leave 1U of space above the unit for ventilation.
i Allow at least 10 cm (4 in) at the rear of the unit for
ventilation.
CAUTION
• DO NOT REMOVE THE EXTERNAL CASES OR CABINETS TO
EXPOSE THE ELECTRONICS. NO USER SERVICEABLE PARTS
ARE INSIDE.
• IF YOU ARE EXPERIENCING PROBLEMS WITH THIS PRODUCT,
CONTACT THE STORE WHERE YOU PURCHASED THE UNIT FOR
A SERVICE REFERRAL. DO NOT USE THE PRODUCT UNTIL IT
HAS BEEN REPAIRED.
• USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF
PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY
RESULT IN HAZARDOUS RADIATION EXPOSURE
The nameplate is located on the bottom of the unit as shown
below.
Front side
Nameplate
TASCAM SERIES 8p Dyna 5
Contents
IMPORTANT SAFETY INSTRUCTIONS ..................................... 3
Introduction ............................................................................. 5
Features .................................................................................... 5
Included items ......................................................................... 6
Conventions used in this manual ........................................... 6
About TASCAM customer support service ............................. 6
Precautions for placement and use ........................................ 6
Beware of condensation ......................................................... 6
Cleaning the unit ..................................................................... 6
Product registration ................................................................ 6
Using the TEAC Global Site ..................................................... 6
Names and functions of parts ................................................ 7
Front panel ................................................................................................. 7
Rear panel ...................................................................................................9
Connecting the power ...........................................................10
Changing the outlet plug .................................................................. 10
Connecting other equipment ............................................... 11
Audio connections ............................................................................... 11
Switching the sample clock ..................................................12
Synchronizing with digital devices ...................................... 13
Making connections to use an OPTICAL OUT (S/MUX) of this
unit as the clock master ...................................................................... 13
Making connections to use the word clock of this unit as the
clock master ............................................................................................ 14
Making connections to use the word clock of a connected
unit as the clock master ...................................................................... 15
Connecting two of these units to synchronize them .............. 16
Specifications .........................................................................17
Ratings ...................................................................................................... 17
Analog audio input ratings ............................................................... 17
Analog outputs ...................................................................................... 17
Digital audio output ratings ............................................................. 17
Control input/output ........................................................................... 17
Audio performance .............................................................................. 18
General ..................................................................................................... 18
Dimensional drawings ........................................................................ 18
Introduction
Thank you very much for purchasing a TASCAM SERIES 8p Dyna
MICROPHONE PREAMP.
Before connecting and using this unit, please take time to
read this manual thoroughly to ensure you understand how to
properly set it up and connect it, as well as how to use its many
useful and convenient functions. After you have finished reading
this manual, please keep it in a safe place for future reference.
You can also download this Owners Manual from the TEAC
Global Site (https://teac-global.com/).
Features
pTASCAM HDIA mic preamps use instrumentation amplifiers
and have outstanding specifications, enabling them to
provide clear natural sound with super-low noise
pSupport for high-resolution recording formats up to
24-bit/192kHz
p8 balanced combo XLR/TRS combo input jacks
pChannel 1–2 instrument (INST) inputs on the front for guitars,
basses and other instruments with high-impedance output
p+48V phantom power can be provided to each input channel
independently
pEach input channel has its own single-knob analog
compressor that includes true bypass
pAnalog overload, compressor and digital indicators as well as
level meters on the front panel
p2 S/MUX optical ports can output all 8 usable inputs even
when 96kHz sampling is used
o 8 outputs at 44.1/48 kHz
o 8 outputs at 88.2/96 kHz
o 4 outputs at 176.4/192 kHz
p25P D-Sub and 8 TRS analog balanced outputs support a
variety of connections with other equipment
pIN/OUT BNC connectors (with IN/OUT/THRU switch) for
flexible audio clock connections
pAC adapter (PS-P1230) included with 3 alternate plugs
6 TASCAM SERIES 8p Dyna
Included items
This product includes the following items.
Take care when opening the package to avoid damaging the
items. Keep the box and packing materials for transportation in
the future.
Please contact the store where you purchased this unit if any
of these items are missing or have been damaged during
transportation.
pMain unit ................................................................................................x 1
pAC adapter (PS-P1230) (with 3 alternate plugs) ....................... x 1
pRackmount screw kit .......................................................................... x 1
pOwners Manual (this document) including warranty ...........x 1
pTASCAM ID registration guide ........................................................x 1
ATTENTION
Always use the included AC adapter (PS-P1230) when using
this unit. Never use the included AC adapter with any other
device. Doing so could cause damage, fire or electric shock.
NOTE
The included AC adapter (PS-P1230) is shipped with alternate
outlet plugs. Please see “Changing the outlet plug” on page
10.
Conventions used in this manual
As necessary, additional information is provided under TIP, NOTE
and CAUTION headings.
TIP
These are tips about how to use the unit.
NOTE
These provide additional explanations and describe special
cases.
ATTENTION
Failure to follow these instructions could result in damage to
equipment or lost data, for example.
VCAUTION
Failure to follow these instructions could result in injury.
About TASCAM customer support
service
TASCAM products are supported and warrantied only in their
country/region of purchase.
To receive support after purchase, on the TASCAM Distributors
list page of the TEAC Global Site (https:// teac-global.com/), search
for the local company or representative for the region where
you purchased the product and contact that organization.
When making inquiries, the address (URL) of the shop or
web shop where it was purchased and the purchase date are
required. Moreover, the warranty card and proof of purchase
might also be necessary.
Precautions for placement and use
pThe operating temperature range of this unit is 0–40 °C.
pDo not install this unit in the following types of locations.
Doing so could make the sound quality worse or cause
malfunction.
Places with significant vibrations
Next to a window or in another location exposed to direct
sunlight
Near heaters or other extremely hot places
Extremely cold places
Very humid or poorly ventilated places
Very dusty places
pTo enable good heat dissipation, do not place anything on
top of the unit.
pDo not place this unit on top of a power amplifier or other
device that generates heat.
Beware of condensation
Condensation could occur if the unit is moved from a cold place
to a warm place, it is used immediately after a cold room has
been heated or it is otherwise exposed to a sudden temperature
change.
To prevent this, or if this occurs, let the unit sit for one or two
hours at the new room temperature before using it.
Cleaning the unit
Use a dry soft cloth to wipe the unit clean. Do not wipe
with chemical cleaning cloths, thinner, alcohol or other
chemical agents. Doing so could damage the surface or cause
discoloration.
Using the TEAC Global Site
You can download updates for this unit from the TEAC Global
Site:
https://teac-global.com/
In the TASCAM Downloads section, select the desired language
to open the Downloads website page for that language.
TASCAM SERIES 8p Dyna 7
Names and functions of parts
Front panel
1 switch
Press to turn the unit on and to put it into standby.
2 1-2 input jacks
These analog inputs are XLR/TRS combo jacks.
They can support high impedance input, including direct
guitar input.
oXLR (1: GND, 2: HOT, 3: COLD)
oTRS (Tip: HOT, Ring: COLD, Sleeve: GND)
Use the input switches (6) to select balanced line (MIC/LINE)
or high-impedance (INST) input for the TRS jacks.
When directly connecting a guitar, bass or other high-
impedance output, set the input switch (6) to INST.
Use the GAIN knobs (1–2) to set input gains.
3 GAIN knobs
Use GAIN knobs 1–8 to adjust the input gain of each channel
independently.
4 +48V indicators
These indicators light when their input switches (6) are set
to +48V.
5 Level meter area
This shows input signal levels.
6 Input switches
Set according to the input sources of input jacks 1–2.
INST: Select when directly connecting a guitar, bass or
other high-impedance instrument. This makes it an
unbalanced input for high impedance.
MIC/LINE: Select when connecting a balanced-output mic or
line-level-output device.
+48V: This provides +48V phantom power to the 1-2 XLR
input jacks.
ATTENTION
i Do not connect or disconnect mics when these switches are
set to +48V.
i Do not supply phantom power to an unbalanced dynamic
mic.
i Supplying phantom power to some ribbon mics will break
them. If you are unsure, do not supply phantom power to a
ribbon mic.
7 COMP knobs
Use these knobs to adjust the threshold levels, which are the
levels when compression begins to be applied to the signals
input to each channel.
8 +48V switch/indicator
Use these switches to supply +48V phantom power to the
MIC/LINE INPUT 3-8 jacks on the back of the unit.
Phantom power can be set for each input channel
independently.
When the +48V switch is on, it lights and provides +48V
phantom power to the XLR connector of the input jack.
ATTENTION
i Do not connect or disconnect mics when a switch is on.
i Do not supply phantom power to an unbalanced dynamic
mic.
i Supplying phantom power to some ribbon mics could break
them. If you are unsure, do not supply phantom power to a
ribbon mic.
9 Sample clock switch
Set the sample clock source to the unit’s internal clock, and
set the sampling frequency. (see “Switching the sample clock”
on page 12)
The sample clock indicators (e) light according to the
currently active sampling frequency being used by the unit
8 TASCAM SERIES 8p Dyna
Level meter area details
0 OL indicators
These light when input signals reach 3 dB below the
maximum input level.
Check if they are lighting and adjust the input gain.
q COMP indicators
These indicators light dimly when compressors are enabled.
They light brightly when compressors are activated by input
signals exceeding their threshold values.
w Level meters
This shows input signal levels after input gain adjustments.
e Sample clock indicators
These indicators light according to the sampling frequency
currently used by the unit.
When the EXT indicator is lit, the unit is using external clock.
When in sample clock source set up mode, the selected
sample clock source will blink repeatedly at short intervals.
(see “Switching the sample clock” on page 12)
NOTE
i When operating using external clock, the EXT indicator
will blink when external clock is not being input. When this
happens, the unit will automatically switch to internal clock.
i When the EXT indicator is blinking (when the unit has
automatically switched to internal clock because external
clock is not being input even though set to use external
clock), that clock frequency will also start blinking if external
clock is input again.
TASCAM SERIES 8p Dyna 9
Rear panel
r OPTICAL OUT (S/MUX) connectors
These connectors output multichannel digital audio in
optical format.
44.1, 48, 88.2, 96, 176.4 and 192 kHz sampling frequencies are
supported.
88.2/96 kHz is supported by S/MUX2, and 176.4/192 kHz is
supported by S/MUX4.
As shown below, the outputs of these two connectors
depend on the sampling frequency.
Sampling frequencies A B
44.1/48 kHz Channels 1-8 Channels 1-8
88.2/96 kHz Channels 1-4 Channels 5-8
176.4/192 kHz Channels 1-2 Channels 3-4
NOTE
S/PDIF format will not be output.
t WORD IN/OUT connectors
These BNC connectors are for the input and output of word
clock signals.
Word clock signals of 44.1, 48, 88.2, 96, 176.4 and 192 kHz can
be input and output.
ATTENTION
If a digital system has multiple word clock masters, serious
problems, including damage to equipment, could occur.
y 75Ω ON/OFF/THRU/WORD OUT switch
Use this switch to make the following settings.
i Whether or not the WORD IN connector has 75Ω
termination
i WORD output THRU/OUT setting (OUT is for WORD only)
u ANALOG OUT connector
This is a 25-pin D-Sub balanced analog output connector.
The nominal output level is +4 dBu.
Use an analog output D-Sub multi-cable to connect this to an
external balanced analog input device and transmit signals
for channels 1–8.
The pin assignments* of the ANALOG OUT connector are as
shown below.
* Pin assignments adhere to the TASCAM DB-25 Pinout
Standard (AES59-2012)
1
14
25
13
24 23 22 21 20 19 18 17 16 15
12 11 10 98765432
ch 1 ch 2 ch 3 ch 4 ch 5 ch 6 ch 7 ch 8
ANALOG OUT
G: GND, C: COLD, H: HOT
ATTENTION
If devices are connected to the LINE OUTPUT jacks at the
same time but are not turned on, the quality of the output
from the ANALOG OUT connector could be degraded.
i LINE OUT (BALANCED) 1-8 jacks
These standard TRS jacks are balanced analog line outputs.
The nominal output level is +4 dBu.
(Tip: HOT, Ring: COLD, Sleeve: GND)
ATTENTION
If a device is connected to the ANALOG OUT connector at
the same time but is not turned on, the quality of the output
from the LINE OUT jacks could be degraded.
o MIC/LINE INPUT 3-8 jacks
These analog inputs are XLR/TRS combo jacks.
These jacks support line input from audio equipment and
keyboards, for example.
oXLR (1: GND, 2: HOT, 3: COLD)
oTRS (Tip: HOT, Ring: COLD, Sleeve: GND)
Use the GAIN knobs (3-8) on the front of the unit to set input
gains.
NOTE
When phantom power is on, +48V phantom power is
supplied to XLR connectors. No power is supplied to the TRS
connectors.
p DC IN 12V connector
Connect the included AC adapter (PS-P1230) here.
a SIGNAL GND connector
This is a ground connector for audio signals.
ATTENTION
This connector is not a power supply grounding connection.
s Cord holder
Hook the cord of the included PS-P1230 AC adapter here to
prevent accidental disconnection
10 TASCAM SERIES 8p Dyna
Connecting the power
Use the included AC adapter (PS-P1230) to connect a power
supply to the unit as shown below.
Power outlet
DC plug
PS-P1230 (included)
In order to prevent the cord from becoming disconnected
during use, wrap it around the cord holder when connecting it.
ATTENTION
Always use the AC adapter (PS-P1230) that was shipped
with the unit. Using a different AC adapter could cause
malfunction, overheating, fire or other problems.
NOTE
The AC adapter for the unit includes 3 types of outlet plugs.
Attach the type of plug that matches the power outlet that
you are using. (see “Changing the outlet plug” on page 10)
Changing the outlet plug
NOTE
When purchased new, the included PS-P1230 AC adapter for
the unit has an outlet plug (A) already attached.
Follow the procedures below to attach and use a different
outlet plug (B - D) if necessary.
1. Fold the outlet plug (A) on the PS-P1230 AC adapter in the
direction of the arrow.
2. Select the plug that matches the AC outlet from the 3 other
types included (B, C or D).
3. Attach the outlet plug to the AC adapter.
This completes changing the outlet plug.
After changing the outlet plug, confirm that it is not loose or
crooked and that everything is normal before plugging it into an
outlet.
ATTENTION
Do not use the adapter if there is anything abnormal about
the plug after changing it. Use when the plug is abnormal
could cause fire or electric shock. Contact the retailer where
you purchased the unit or a TASCAM customer support
service to request repair.
TASCAM SERIES 8p Dyna 11
Connecting other equipment
These are examples of SERIES 8p Dyna connections.
Precautions before making connections
pCarefully read the operation manuals of the devices to be
connected and then connect them correctly.
pBefore making connections, turn this unit and all equipment
to be connected off (standby).
pIf possible, install all connected devices so that they are
powered from the same AC power supply line. When using
a power strip or similar device, be sure to use one that has a
thick cable with high current capacity in order to minimize
voltage fluctuations in the AC power supply.
Mic Guitar
Audio interface with S/MUX
TASCAM ML-16D
TASCAM Model 24
Mic
Examples of connections with a SERIES 8p Dyna
Audio connections
Analog audio signals input into this device from mics, guitars,
keyboards and other audio equipment can be output to
connected devices as analog output from the 25-pin D-Sub and
TRS balanced outputs as well as converted into digital signals
and transmitted from the S/MUX connectors. In addition, by
connecting speakers (through an amplifier) to this unit, you can
monitor audio signals that are input to this unit.
VCAUTION
Before connecting audio equipment, set the GAIN and COMP
knobs to their lowest values. Failure to do so could cause
sudden loud noises from monitoring equipment, and this
could damage the equipment or harm hearing.
ATTENTION
When connecting devices to both the ANALOG OUT
connector and LINE OUTPUT jacks, turn on the devices
connected to both connector types when using this unit. If
devices connected to only one type of connector are turned
on, the quality of the analog output could be degraded.
Connecting microphones
Dynamic mics
Connect these to the 1-2 input jacks on the front or the
MIC/LINE INPUT 3-8 jacks on the back of the unit.
Condenser mics
When using a condenser mic that requires phantom
power, connect it to the 1-2 input jacks on the front or the
MIC/LINE INPUT 3-8 jacks on the back of the unit.
Set the input switch to +48V when connecting them to
the 1-2 input jacks on the front of the unit. When an input
switch is set to +48V, its +48V indicator on the front of the
unit lights.
When connecting them to the MIC/LINE INPUT 3-8 input
jacks on the back of the unit, turn their +48V switches on.
The +48V switches light when they are on.
VCAUTION
Set the GAIN and COMP knobs to their minimum values before
changing input switch or +48V switch settings. Failure to do so
could cause sudden loud noises from monitoring equipment,
and this could damage equipment or harm hearing.
ATTENTION
i Input switches can be set for each channel separately. Do not
set the switch to +48V when connecting a mic that does not
require phantom power.
i Do not connect or disconnect mics when the switch is set to
+48V. Doing so could cause a loud noise and might damage
this unit and connected equipment.
i Set the switch to +48V only when using a condenser
microphone that requires phantom power. Setting the
switch to +48V when a dynamic mic or other device that
does not require it is connected could damage this unit and
connected equipment.
i +48V switches can be set for each channel separately. Do not
turn a +48V switch on when connecting a mic that does not
require phantom power.
i Do not connect or disconnect mics when a +48V switch is on.
Doing so could cause a loud noise and might damage this
unit and connected equipment.
i Turn a +48V switch on only when using a condenser mic
that requires phantom power. Turning a +48V switch on
when a dynamic mic or other mic that does not require
it is connected could damage this unit and connected
equipment.
i Supplying phantom power to some ribbon mics could break
them. If you are unsure, do not supply phantom power to a
ribbon mic.
12 TASCAM SERIES 8p Dyna
Connecting guitars and basses
When connecting a guitar, bass guitar or other high-impedance
output directly to this unit, use input jack 1 or 2 on the front of
the unit and set its input switch to INST.
NOTE
When connecting an instrument with active output or when
the sound passes through an effects unit, for example, set the
input switch to MIC/LINE
Connecting electronic devices and other
audio equipment
When connecting an electronic instrument or other audio
equipment, for example, to this unit, use a 1-2 jack on the front
of the unit and set its input switch to MIC/LINE.
Connecting analog record players
The output of an analog record player cannot be connected
directly to this unit. To connect an analog record player to this
unit, a phono amp and equalizer (or an audio amplifier that has
phono input jacks) must be connected between them.
Connecting digital equipment
Connect an OPTICAL OUT (S/MUX) connector on this unit to an
S/MUX input connector on a digital device.
Switching the sample clock
Set the sample clock source to the unit’s internal clock, and set
the sampling frequency.
The sample clock source can also be set to an external clock
(WORD IN).
1. Press and hold the sample clock switch to put the unit into
sample clock setup mode.
The selected sample clock source will blink repeatedly at
short intervals.
2. Press the sample clock switch to change the sample clock
source.
44.1k
48k
88.2
k
96k
176.4k
192k
EX
T
3. After selecting the sample clock source, press and hold the
sample clock switch to confirm the setting.
NOTE
i This setting is retained even when the unit is turned off.
i When the EXT indicator is blinking and a valid word clock
signal is being input through the WORD IN connector, the
corresponding sample clock indicator will blink.
TASCAM SERIES 8p Dyna 13
Synchronizing with digital devices
Using an OPTICAL OUT (S/MUX) of this unit
as the clock source master
The signal output from an OPTICAL OUT (S/MUX) connector of
this unit can be used as the master clock to synchronize with
connected devices.
Use the sample clock switch (9) to set the sample clock, causing
the corresponding indicator (e) to light. (see “Switching the
sample clock” on page 12)
Using the word clock of this unit as the clock
master
The signal output from the WORD OUT connector of this unit
can be used as the master clock to synchronize connected
devices.
Set the connected device to accept external clock input.
Using the word clock of an external device as
the master clock
The signal input through the WORD IN connector of this unit
can be used as the master clock to synchronize with connected
devices.
Use the sample clock switch (9) to set the source to EXT. (see
“Switching the sample clock” on page 12)
Making connections to use an OPTICAL OUT
(S/MUX) of this unit as the clock master
This connection method is also suitable for other audio
interfaces with OPTICAL IN connectors.
44.1/48kHz sampling frequency connection
examples
TASCAM SERIES 8p Dyna
TASCAM SERIES 102i
Connecting this unit with a SERIES 102i
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Connecting this unit with a SERIES 208i
Cable connections
o Use an optical cable to connect an OPTICAL OUT (S/
MUX) connector of this unit to an OPTICAL IN (S/MUX)
connector of a TASCAM SERIES 102i/208i. Use one optical
cable to connect to either the A or B connector.
Setting the sample clock source
o Use the sample clock switch to set the clock source of this
unit. (see “Switching the sample clock” on page 12)
o To set the clock source of the TASCAM SERIES 102i/208i,
set the Settings Panel INFORMATION screen Sample Clock
Source item to “OPTICAL A or “OPTICAL B” (SERIES 208i
only).
When the sample frequency is 88.2/96kHz (S/
MUX2) or 176.4/192kHz (S/MUX4)
TASCAM SERIES 8p Dyna
TASCAM SERIES 208i
Cable connections
o Use 2 optical cables to connect the OPTICAL OUT (S/
MUX) connectors of this unit to the OPTICAL IN (S/MUX)
connectors of a TASCAM SERIES 208i.
Setting the sample clock source
o Use the sample clock switch to set the clock source of this
unit. (see “Switching the sample clock” on page 12)
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “OPTICAL A or “OPTICAL B”.
14 TASCAM SERIES 8p Dyna
Making connections to use the word
clock of this unit as the clock master
This connection method also applies to other audio interfaces
with WORD IN connectors.
Connection example when using the word
clock of this unit as the clock master at a
44.1/48kHz sampling frequency
TASCAM SERIES 8p Dyna
TASCAM SERIES 208i
Cable connections
o Use one optical cable to connect either the A or B
OPTICAL OUT (S/MUX) connector of this unit to the A or B
OPTICAL IN (S/MUX) connector of a TASCAM SERIES 208i.
o Use a BNC cable to connect the WORD OUT connector of
this unit to the WORD IN connector of a TASCAM SERIES
208i.
Setting the switch
o Set the TASCAM SERIES 208i 75Ω ON/OFF switch to ON.
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to WORD OUT.
Setting the sample clock source
o Use the sample clock switch to set the clock source of this
unit. (see “Switching the sample clock” on page 12)
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “WORD.
Connection example when using the word
clock of this unit as the clock master at
88.2/96kHz (S/MUX2) or 176.4/192kHz (S/
MUX4) sampling frequencies
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Cable connections
o Use 2 optical cables to connect the OPTICAL OUT (S/
MUX) connectors of this unit to the OPTICAL IN (S/MUX)
connectors of a TASCAM SERIES 208i.
o Use a BNC cable to connect the WORD OUT connector of
this unit to the WORD IN connector of a TASCAM SERIES
208i.
Setting the switch
o Set the TASCAM SERIES 208i 75Ω ON/OFF switch to ON.
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to WORD OUT.
Setting the sample clock source
o Use the sample clock switch to set the clock source of this
unit. (see “Switching the sample clock” on page 12)
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “WORD.
TASCAM SERIES 8p Dyna 15
Making connections to use the word
clock of a connected unit as the clock
master
These connection settings also apply to other audio interfaces
with WORD OUT connectors.
Connection example when using the word
clock of a connected device as the clock
master at a 44.1/48kHz sampling frequency
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Cable connections
o Use one optical cable to connect either the A or B
OPTICAL IN (S/MUX) connector of a TASCAM SERIES 208i
to the A or B OPTICAL OUT (S/MUX) connector of this unit.
o Use a BNC cable to connect the WORD OUT connector of
a TASCAM SERIES 208i to the WORD IN connector of this
unit.
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to ON.
Setting the sample clock source
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “INTERNAL.
o Use the sample clock switch to set the clock source of this
unit to EXT. (see “Switching the sample clock” on page
12)
Connection example when using the
word clock of a connected device as the
clock master at 88.2/96kHz (S/MUX2)
or 176.4/192kHz (S/MUX4) sampling
frequencies
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna
Cable connections
o Use 2 optical cables to connect the OPTICAL IN (S/MUX)
connectors of a TASCAM SERIES 208i to the OPTICAL OUT
(S/MUX) connectors of this unit.
o Use a BNC cable to connect the WORD OUT connector of
a TASCAM SERIES 208i to the WORD IN connector of this
unit.
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on this unit
to ON.
Setting the sample clock source
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “INTERNAL.
o Use the sample clock switch to set the clock source of this
unit- to EXT. (see “Switching the sample clock on page
12)
16 TASCAM SERIES 8p Dyna
Connecting two of these units to
synchronize them
Increasing the number of input channels to 16 is possible by
connecting two of these units and synchronizing their clocks.
Connection example when using the word
clock of this unit as the clock master
TASCAM SERIES 8p Dyna unit 1
TASCAM SERIES 8p Dyna unit 2
TASCAM SERIES 208i
Cable connections
o Use optical cables to connect OPTICAL OUT (S/MUX)
connectors of two of these units to the OPTICAL IN (S/
MUX) connectors of a TASCAM SERIES 208i.
o Use a BNC cable to connect the WORD OUT connector of
the first of these units (TASCAM SERIES 8p Dyna unit 1)
to the WORD IN connector of the second unit (TASCAM
SERIES 8p Dyna unit 2).
o Use a BNC cable to connect the WORD OUT connector of
the second of these units (TASCAM SERIES 8p Dyna unit 2)
to the WORD IN connector of a TASCAM SERIES 208i.
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on the
second unit (TASCAM SERIES 8p Dyna unit 2) to THRU.
o Set the TASCAM SERIES 208i 75Ω ON/OFF switch to ON.
Setting the sample clock source
o Use the sample clock switch to set the clock source of the
first of these units (SERIES 8p Dyna unit 1). (see “Switching
the sample clock” on page 12)
o Use the sample clock switch to set the clock source of the
second unit (slave unit) to EXT. (see “Switching the sample
clock” on page 12)
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “WORD.
Connection example when using the word
clock of a TASCAM SERIES 208i unit as the
clock master
TASCAM SERIES 208i
TASCAM SERIES 8p Dyna unit 1
TASCAM SERIES 8p Dyna unit 2
Cable connections
o Use optical cables to connect OPTICAL OUT (S/MUX)
connectors of two of these units to the OPTICAL IN (S/
MUX) connectors of a TASCAM SERIES 208i.
o Use a BNC cable to connect the WORD OUT connector of a
TASCAM SERIES 208i to the WORD IN connector of the first
unit (TASCAM SERIES 8p Dyna unit 1).
o Use a BNC cable to connect the WORD OUT connector of
the first of these units (TASCAM SERIES 8p Dyna unit 1)
to the WORD IN connector of the second unit (TASCAM
SERIES 8p Dyna unit 2).
Setting the switch
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on the first
unit (TASCAM SERIES 8p Dyna unit 1) to THRU.
o Set the 75Ω ON/OFF/THRU/WORD OUT switch on the
second unit (TASCAM SERIES 8p Dyna unit 2) to ON.
Setting the sample clock source
o Use the sample clock switches to set the clock sources on
these two units to EXT. (see “Switching the sample clock”
on page 12)
o To set the clock source of the TASCAM SERIES 208i, set the
Settings Panel INFORMATION screen Sample Clock Source
item to “INTERNAL.
TASCAM SERIES 8p Dyna 17
Specifications
Ratings
Sampling frequencies
44.1, 48, 88.2, 96, 176.4, 192 kHz
Quantization bit depth
24-bit
Input channels
8 channels
Analog output channels
8 channels
OPTICAL OUT (S/MUX) output channels
8 channels S/MUX (44.1/48kHz)
A: Channels 1-8
B: Channels 1-8
8 channels S/MUX2 (88.2/96kHz)
A: Channels 1-4
B: Channels 5-8
4 channels S/MUX4 (176.4/192kHz)
A: Channels 1-2
B: Channels 3-4
Analog audio input ratings
Mic inputs (balanced)
Front panel 1–2 input jacks
(when the input switch is set to MIC/LINE)
Rear panel MIC/LINE INPUT 3-8 jacks
Connector : XLR-3-31 equivalent (1: GND, 2: HOT, 3: COLD)
Input impedance: 2.2 kΩ
Rated input level:
-58 dBu (0.001 Vrms, GAIN knob at maximum)
-6 dBu (0.388 Vrms, GAIN knob at minimum)
Maximum input level: +10 dBu (2.45 Vrms)
Gain range: 52 dB
Instrument inputs (unbalanced)
Front panel 1–2 input jacks
(when the input switch is set to INST)
Connectors: 6.3mm (1/4”) standard TS jacks
(Tip: HOT, Sleeve: GND)
Input impedance: 900 kΩ or higher
Rated input level:
-58 dBV (0.0012 Vrms, GAIN knob at maximum)
-6 dBV (0.501 Vrms, GAIN knob at minimum)
Maximum input level: +10 dBV (3.162 Vrms)
Gain range: 52 dB
Line inputs (balanced)
Front panel 1–2 input jacks
(when the input switch is set to MIC/LINE)
Rear panel MIC/LINE INPUT 3-8 jacks
Connectors: 6.3mm (1/4”) standard TRS jacks
(Tip: HOT, Ring: COLD, Sleeve: GND)
Input impedance: 10 kΩ
Rated input level:
-48 dBu (0.0003 Vrms, GAIN knob at maximum)
+4 dBu (1.228 Vrms, GAIN knob at minimum)
Maximum input level: +24 dBu (12.282 Vrms)
Gain range: 52 dB
Compressor
3:1 ratio
30dB threshold range
Analog outputs
Analog output (balanced, ANALOG OUT)
Connector: D-sub 25-pin
Locking screws: No. 4-40 UNC (inch type)
Nominal output level: +4 dBu (1.228 Vrms)
Maximum output level: +20 dBu (7.75 Vrms)
Output impedance: 200 Ω or lower
Applicable load impedance: 2 kΩ or higher
Line outputs (balanced, LINE OUTPUT 1-8)
Connectors: 6.3mm (1/4”) standard TRS jacks
(Tip: HOT, Ring: COLD, Sleeve: GND)
Output impedance: 200 Ω or lower
Nominal output level: +4 dBu (1.228 Vrms)
Maximum output level: +20 dBu (7.75 Vrms)
Digital audio output ratings
OPTICAL OUT (S/MUX)
Connectors: OPTICAL (JEITA RC-5720C)
Signal format: Multi-channel optical format
(supports S/MUX2 and S/MUX4 when 88.2, 96, 176.4 or
192 kHz)
Control input/output
WORD IN connector
Connector: BNC
Input voltage: 2.0 Vpp - 5.0 Vpp
Input impedance: 75 Ω ±10%
Permitted frequency deviation during external
synchronization: ±100 ppm
Terminal on/off switch
WORD OUT connector
Connector: BNC
Output voltage: 2.0Vpp (into 75 Ω)
Output impedance: 75 Ω ±10 %
Sampling frequencies: 44.1, 48, 88.2, 96, 176.4 and 192 kHz
OUT/THRU switch
18 TASCAM SERIES 8p Dyna
Audio performance
Mic amp EIN (equivalent input noise)
-127 dBu or lower
Analog input and output
Frequency response
MIC/LINE w LINE OUT
20 Hz - 40 kHz: ±0.5 dB (JEITA), 40 kHz - 80 kHz: ±5 dB
(JEITA)
S/N ratio
116 dB
(MIC/LINE/INST to LINE OUT, GAIN knob at minimum,
JEITA)
Distortion
0.0007%
(MIC/LINE to LINE OUT, 1kHz sine wave, maximum input
level, GAIN knob at minimum)
0.0009%
(INST to LINE OUT, 1kHz sine wave, maximum input level,
GAIN knob at minimum)
Crosstalk
119 dB
(MIC to LINE OUT, 1kHz sine wave, GAIN knob at
minimum)
Analog input to digital output (S/MUX)
Frequency response
MIC/LINE (analog) to digital output (S/MUX)
At 44.1/48 kHz and 20 Hz - 20 kHz: ±0.5 dB (JEITA)
At 88.2/96 kHz and 20 Hz - 40kHz: ±0.5 dB (JEITA)
At 176.4/192 kHz and 20 Hz - 80 kHz: ±5 dB (JEITA)
S/N ratio
113 dB (44.1/48 kHz)
113 dB (88.2/96 kHz)
111 dB (176.4/192 kHz)
(MIC/LINE/INST to digital output (S/MUX), GAIN knob at
minimum, JEITA)
Distortion
0.001%
(MIC/LINE/INST to digital output (S/MUX), 1kHz sine wave,
maximum input level, GAIN knob at minimum)
Crosstalk
114 dB
(MIC (analog) to digital output (S/MUX), 1kHz sine wave,
GAIN knob at minimum)
General
Power
DC12V AC adapter (PS-P1230)
Power consumption
16 W
Dimensions
482 × 44.8 × 228.8mm (W x H x D, including protrusions)
Weight
2.6 kg
Operating temperature range
0–40 °C (32–104 °F)
Dimensional drawings
465mm
482.0mm 44mm
0.8mm
31.8mm 18.3mm 198.5mm
12.0mm
pIllustrations in this manual might differ in part from the
actual product.
pSpecifications and external appearance might be changed
without notification to improve the product.
TASCAM SERIES 8p Dyna 19
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT: POUR PRÉVENIR LES RISQUES
D'INCENDIE ET D'ÉLECTROCUTION, N'EXPOSEZ PAS CET
APPAREIL À LA PLUIE NI À L'HUMIDITÉ.
Pour le Canada
THIS CLASS B DIGITAL APPARATUS COMPLIES WITH CANADIAN
ICES-003.
CET APPAREIL NUMÉRIQUE DE LA CLASSE B EST CONFORME À
LA NORME NMB-003 DU CANADA.
Ce produit est conforme aux impératifs des
directives européennes et autres règlements de la
Commission.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Tenez compte de tous les avertissements.
4. Suivez toutes les instructions.
5. N’utilisez pas cet appareil avec de l’eau à proximité.
6. Nettoyez-le uniquement avec un chiffon sec.
7. Ne bloquez aucune ouverture de ventilation. Installez-le
conformément aux instructions du fabricant.
8. Ne l’installez pas près de sources de chaleur telles que
des radiateurs, bouches de chauffage, poêles ou autres
appareils (y compris des amplificateurs) dégageant de la
chaleur.
9. Ne neutralisez pas la fonction de sécurité de la fiche
polarisée ou de terre. Une fiche polarisée a deux broches,
l’une plus large que l’autre. Une fiche de terre a deux
broches identiques et une troisième broche pour la mise à
la terre. La broche plus large ou la troisième broche servent
à votre sécurité. Si la fiche fournie n’entre pas dans votre
prise, consultez un électricien pour le remplacement de la
prise obsolète.
10. Évitez de marcher sur le cordon d’alimentation et de
le pincer, en particulier au niveau des fiches, des prises
secteur, et du point de sortie de l’appareil.
11. N’utilisez que des fixations/accessoires spécifiés par le
fabricant.
12. Utilisez-le uniquement avec le chariot, socle, trépied,
support ou table spécifié par le fabricant ou vendu avec
l’appareil. Si un chariot est utilisé, faites attention à ne pas
être blessé par un renversement lors du déplacement de
l’ensemble chariot/appareil.
13. Débranchez cet appareil en cas d’orage ou de non
utilisation prolongée.
14. Confiez toute réparation à des techniciens de maintenance
qualifiés. Une réparation est nécessaire si l’appareil a été
endommagé d’une quelconque façon, par exemple si le
cordon ou la fiche d’alimentation est endommagé, si du
liquide a été renversé sur l’appareil ou si des objets sont
tombés dedans, si l’appareil a été exposé à la pluie ou à
l’humidité, s’il ne fonctionne pas normalement, ou s’il est
tombé.
• L’appareil tire un courant nominal de veille de la prise secteur
quand son interrupteur POWER ou STANDBY/ON nest pas en
position ON.
• La fiche secteur est utilisée comme dispositif de déconnexion
et doit donc toujours rester disponible.
• Des précautions doivent être prises en cas d’utilisation
d’écouteurs ou d’un casque avec le produit car une pression
acoustique excessive (volume trop fort) dans les écouteurs
ou dans le casque peut causer une perte auditive.
• Si vous rencontrez des problèmes avec ce produit, contactez
TEAC pour une assistance technique. N’utilisez pas le produit
tant qu’il n’a pas été réparé.
MODE D'EMPLOI
20 TASCAM SERIES 8p Dyna
ATTENTION
• N'exposez pas cet appareil aux gouttes ni aux
éclaboussures.
• Ne placez pas d'objet rempli de liquide sur l'appareil,
comme par exemple un vase.
• N’installez pas cet appareil dans un espace confiné comme
une bibliothèque ou un meuble similaire.
• L’appareil doit être placé suffisamment près de la prise de
courant pour que vous puissiez à tout moment attraper
facilement la fiche du cordon d'alimentation.
• Si le produit utilise des piles/batteries (y compris un pack
de batteries ou des batteries fixes), elles ne doivent pas être
exposées au soleil, au feu ou à une chaleur excessive.
• PRÉCAUTION pour les produits qui utilisent des batteries
remplaçables au lithium: remplacer une batterie par
un modèle incorrect entraîne un risque d'explosion.
Remplacez-les uniquement par un type identique ou
équivalent.
• Exposer la batterie installée à une pression atmosphérique
extrêmement faible peut entraîner une explosion ou la fuite
d’un liquide ou d’un gaz inflammable.
Pour les consommateurs européens
Mise au rebut des équipements électriques et
électroniques
(a) Tous les équipements électriques et électroniques doivent
être traités séparément de la collecte municipale d'ordures
ménagères dans des points de collecte désignés par le
gouvernement ou les autorités locales.
(b) En vous débarrassant correctement des équipements
électriques et électroniques, vous contribuerez à la
sauvegarde de précieuses ressources et à la prévention
de potentiels effets négatifs sur la santé humaine et
l'environnement.
(c) Le traitement incorrect des déchets d'équipements
électriques et électroniques peut avoir des effets graves
sur l'environnement et la santé humaine en raison
de la présence de substances dangereuses dans les
équipements.
(d) Le symbole de déchets d'équipements électriques
et électroniques (DEEE), qui représente une
poubelle sur roues barrée d'une croix, indique
que l'équipement électrique et électronique doit
être collecté et traité séparément des déchets
ménagers.
(e) Des systèmes de retour et de collecte sont disponibles
pour l'utilisateur final. Pour des informations plus détaillées
sur la mise au rebut des vieux équipements électriques et
électroniques, veuillez contacter votre mairie, le service
d'ordures ménagères ou le magasin dans lequel vous avez
acquis l'équipement.
MONTAGE EN RACK DE L’UNITÉ
Utilisez le kit de vis pour montage en rack pour installer l’unité
dans un rack 19” standard, comme représenté ci-dessous.
Retirez les pieds de l’unité avant le montage.
ATTENTION
i Laissez 1U d’espace au-dessus de l’unité pour la ventilation.
i Laissez au moins 10 cm à l’arrière de l’unité pour la
ventilation.
ATTENTION
• N’EXPOSEZ PAS L’ÉLECTRONIQUE EN OUVRANT LE BOÎTIER
OU SES CAPOTS. AUCUNE PIÈCE INTERNE N’EST RÉPARABLE
PAR L’UTILISATEUR.
• SI VOUS RENCONTREZ DES PROBLÈMES AVEC CE PRODUIT,
CONTACTEZ LE MAGASIN DANS LEQUEL VOUS LAVEZ
ACHETÉ POUR UNE ASSISTANCE TECHNIQUE. N’UTILISEZ PAS
LE PRODUIT TANT QU’IL N’A PAS ÉTÉ RÉPARÉ.
• L’UTILISATION DE COMMANDES, DE RÉGLAGES OU LE SUIVI
DE PROCÉDURES AUTRES QUE CE QUI EST DÉCRIT DANS
CE DOCUMENT PEUT PROVOQUER UNE EXPOSITION À UN
RAYONNEMENT DANGEREUX.
La plaque signalétique se trouve sous l’unité comme indiqué
ci-dessous.
Face avant
Plaque signalétique
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Tascam SERIES 8p Dyna Le manuel du propriétaire

Catégorie
Équipement musical supplémentaire
Taper
Le manuel du propriétaire