Vari-Lite VL6000 BEAM Guide de démarrage rapide

Catégorie
Stroboscopes
Taper
Guide de démarrage rapide

VL6000 Beam Luminaire
QuickStart Guide
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
1 27 April 2017 02.9708.0001
Introduction
About This Guide
This Quickstart Guide is intended for a knowledgeable user to unpack, install, and use the VL6000 Beam Luminaire in a short time period.
For the complete manual in PDF format, please visit our web site at: www.philips.com/entertainmentlighting and click the user manual
download link on the product downloads page. The complete manual provides you all information related to accessories, menu structures,
DMX channel mapping/modes, and care for your new luminaire.
Read this manual in its entirety before operating luminaire. Keep this guide for future reference.
WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or
others.
AVERTISSEMENT: Il est important de lire toutes les instructions de sécurité et d'installation d'accompagnement pour éviter d'endommager le produit
et les risques de blessures à vous-même ou les autres.
Notes:
For complete product description, features, and specifications, refer to product datasheet on the Vari-Lite web site
at www.philips.com/entertainmentlighting.
For power requirements, refer to “Current vs. Voltage” on page 14.
VL6000 Beam Luminaires accept glass gobos only. Use of metal gobos will void the luminaire’s warranty.
Additional Documentation
For more information on installing DMX512 control systems, the following publication is available for purchase from the United States
Institute for Theatre Technology (USITT), “Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition” (ISBN:
9780955703522). USITT Contact Information:
USITT
315 South Crouse Avenue, Suite 200
Syracuse, New York 13210-1844 USA
Phone: 800-938-7488 or +1-315-463-6463
Fax: 866-398-7488 or +1-315-463-6525
Web Site: www.usitt.org
Customer Service
Our Goal
At Vari-Lite, we are committed to providing you the highest quality in customer service. Our comprehensive resources are available to help
your business succeed and ensure you get the full benefit of being a Vari-Lite customer. Whether your needs are telephone troubleshooting
assistance, product training or technical service, our full-time staff of experienced professionals are on-hand to provide support.
How to Reach Us
For assistance in your area, call the dealer from which your product was purchased.
or Contact an Authorized Service Center
or Contact the Vari-Lite Customer Service Department, 7am - 6pm CST Monday through Friday, at the following:
phone:1-877-VARI-LITE (1-877-827-4548) or +1-214-647-7880
Note: Performing maintenance procedures may void the product warranty. Refer to the Vari-Lite Limited Warranty card included in the
product shipping package for more information. For all service and maintenance issues, please contact your local Authorized
VARILITE Dealer or Service Center.
Additional Resources
For additional resources and documentation on this product, please visit our website at www.philips.com/entertainmentlighting and follow
the Support link.
Document Number: 02.9708.0001
Version as of: 27 April 2017
VL6000 Beam Luminaire QuickStart Guide
©2017 Vari-Lite. All rights reserved.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 2
Compliance & Safety Notices
Compliance
SAFETY Standards
We, Vari-Lite, 10911 Petal Street, Dallas, Texas 75238 declare under our responsibility for the products contained herein are in
conformity with the essential requirements of the following European Directives and Safety standards for United States and Canada.
EN 60589-2-17:1989+A2:1991 used in conjunction with 60598-1:2008/A11:2009
UL 1573 Issue: 2003/05/29 Ed: 4 Rev: 2016/12/22
CSA C22.2#166:2015 Ed.2
EMC Standards
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-
Lite system, service, and safety guidelines, may cause harmful interference to radio communications.
FCC 47CFR 15:2016
CENELEC EN 55015:2006/12/01
CES-005:2007/02/01
Safety Notice
It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation
before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product.
Safety symbols used throughout this manual are as follows:
GENERAL INFORMATION PERTAINING TO PROTECTION AGAINST ELECTRICAL SHOCK, FIRE, EXPOSURE TO EXCESSIVE
UV RADIATION, AND INJURY TO PERSONS CAN BE FOUND BELOW.
WARNING:
INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST FIRE
1. VARILITE luminaires have been designed for use with specific lamp types. The VL6000 Beam Luminaire requires a certain type of
lamp (see “Replacement Items/Accessories” on page 8 for all lamp types). Installing another type or unapproved lamp may be
hazardous.
2. Luminaires may be mounted on any type of surface as long as mounting instructions are followed. See instructions detailed in this
manual.
3. Note distance requirement from combustible materials or illuminated objects for VARILITE luminaires.
WARNING:
INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST ELECTRICAL SHOCK
1. VARILITE luminaires are designed for dry locations only. Exposure to rain or moisture may damage luminaire.
2. Disconnect power before servicing any VARILITE equipment.
3. Servicing to be performed by qualified personnel only.
CAUTION advising of potential damage to product.
WARNING advising of potential injury or death to persons.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
3 27 April 2017 02.9708.0001
WARNING:
INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO
UV RADIATION
1. Many VARILITE luminaires use a lamp that produces UV radiation. DO NOT look directly at lamp.
2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become
visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches. Replace any cracked or
protective shields.
WARNING:
INSTRUCTIONS FOR PROTECTION AGAINST INJURY TO PERSONS
1. Exterior surfaces of the luminaire will be hot during operation. Use appropriate safety equipment (gloves, eye protection, etc.) when
handling and adjusting hot equipment and components.
2. Luminaires will have a hot lamp when operating. Disconnect power and allow lamp to cool before replacing.
3. Arc lamps emit ultraviolet radiation which can cause serious skin burn and eye inflammation. Additionally, arc lamps operate under
high pressure at very high temperatures. Should the lamp break, there can exist a danger of personal injury and/or fire from broken lamp
particles being discharged.
4. Wear eye protection when relamping.
5. Appropriate safety equipment (gloves, eye protection) should be used when handling damaged lamps.
6. If lamp is touched with bare hands, clean lamp with denatured alcohol and wipe with lint-free cloth before installing or powering up the
luminaire.
7. The lamp shall be changed if it has become damaged or thermally deformed.
WARNING:
RF INTERFERENCE
This is a Class A product. In a domestic environment this product may cause radio interference, in which case, the user may be required to
take adequate measures.
Notes de sécurité
Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les
renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les
avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
Les symboles de sécurité utilisés dans ce guide sont les suivants :
CETTE SECTION CONTIENT DES INFORMATIONS GÉNÉRALES POUR SE PROTÉGER CONTRE LES DÉCHARGES
ÉLECTRIQUES, LES INCENDIES, L’EXPOSITION EXCESSIVE AUX RAYONS UV ET TOUT AUTRE ACCIDENT POUVANT
ENTRAÎNER DES BLESSURES.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE LES INCENDIES
1. Les luminaires VARILITE ont été conçus pour être utilisés uniquement avec certaines type de lampes. Vérifier le type de lampe avant
de remplacer les lampes. L’installation d’un autre type de lampe peut poser un danger.
2. Les luminaires peuvent être fixés sur tout type de surface tant que les directives de montage sont respectées. Voir les explications
détaillées dans ce guide.
3. Vérifier la distance à respecter entre les matériaux combustibles ou les objets illuminés et les luminaires VARILITE.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE LES DÉCHARGES ÉLECTRIQUES
1. Les luminaires VARILITE sont conçus pour une utilisation au sec uniquement. Une exposition à la pluie et à l’humidité risque
d’endommager le luminaire.
ATTENTION Ce symbole annonce que l’appareil risque d’être endommagé.
AVERTISSEMENT Ce symbole annonce qu’il y a risque d’accident grave ou même fatal.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 4
2. Débrancher l’appareil avant de procéder à la révision de tout matériel VARILITE.
3. Les révisions doivent être effectuées uniquement par des personnes qualifiées.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAY-
ONS UV
1. Plusieurs luminaires VARILITE utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe.
2. L’utilisation des luminaires sans lentille ou blindage pose des risques. Tous blindages, lentilles ou écrans ultraviolet visiblement
endommagés au point que leur efficacité en est affectée doivent être remplacés, par exemple s’il y a des fissures ou de profondes
rayures.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE LES ACCIDENTS POUVANT ENTRAÎNER
DES BLESSURES
1. Les surfaces externes du luminaire deviennent brûlantes quand l’appareil est en marche. Pour manœuvrer ou ajuster des appareils
brûlants et leurs composants, se protéger suffisamment (gants, protection pour les yeux, etc.).
2. La lampe du luminaire est brûlante lorqu’il est en marche. Débrancher le courant et attendre que la lampe ait refroidi avant de la
remplacer.
3. Les lampes à arc émettent des rayons ultraviolets pouvant causer de graves brûlures sur la peau et une inflammation des yeux. De plus,
les lampes à arc fonctionnent sous haute tension à de très hautes températures. Si la lampe se casse, les particules de la lampe cassée
peuvent causer blessures et/ou incendie en s’éparpillant.
4. Se protéger les yeux pour remplacer la lampe.
5. Utiliser des appareils de protection appropriés (gants, protection des yeux) pour manier des lampes endommagées.
6. Si la lampe a été touchée avec des mains nues, la nettoyer avec de l’alcool dénaturé et l’essuyer avec un chiffon non-pelucheux avant
d’installer ou de brancher le luminaire.
7. Si la lampe a été endommagée ou a reçu une déformation thermique, elle doit être remplacée.
AVERTISSEMENT:
INTERFÉRENCE RF
Cet appareil est de Classe A. Dans un environnement domestique, cet appareil peut causer des interférences radio, et si c’est le cas,
l’utilisateur peut avoir à prendre des mesures adéquates.
Other
Operational Temperature / Température de fonctionnement
The VL6000 Beam Luminaire has one operational mode. Refer to Table 1-1, “VL6000 Beam Luminaire Environmental
Operational Temperatures” for information on environment temperature ranges associated with this mode.
Le VL6000 Beam Luminaire a un mode opérationnel. Reportez-vous à Table 1-1, “VL6000 Beam Luminaire Environmental
Operational Temperatures” pour des informations sur les plages de température environnementales associées à ce mode.
Table 1-1: VL6000 Beam Luminaire Environmental Operational Temperatures
Battery Information / Informations sur la batterie
This unit has a battery. Warning: Caution risk of explosion if battery is replaced by an
incorrect type. Dispose of used batteries according to the instructions.
Cet appareil dispose d'une batterie. Avertissement: Attention risque d'explosion si la
batterie de remplacement par un type incorrect. Jetez les piles usageesselon les
instructions.
Minimum to Maximum Environmental Temperature
CF
-20
o
to 50
o
-4
o
to 122
o
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
5 27 April 2017 02.9708.0001
About The VL6000 Beam Luminaire
Included Items
The following illustration shows all items included with the luminaire:
Figure 1: VL6000 Beam Luminaire Included Items
Replacement Items/Accessories
The following optional and/or replacement items can be ordered directly from your Authorized VARILITE Dealer. When ordering, please
order by the Vari-Lite part number.
Note: For approved lamp types, see the latest version of Philips Entertainment Lighting technical notice TN-248 in the product
downloads section on the Vari-Lite web site, www.philips.com/entertainmentlighting.
Note: Please check with Authorized Vari*Lite Dealer for availability on accessories.
Vari-Lite Part No. Accessory
PCT1BE
AC Input Cable,
Neutrik® powerCON® True1 with Bare End (no connector), 1 Meter
PC1GTL208
AC Input Cable,
Neutrik® powerCON® True1 with Twist Lock (Male), 250V, 1 Meter
PCT1GP
AC Input Cable,
Neutrik® powerCON® True1 with Stage Pin (Male), 1 Meter
PEGASUS Luminaire Programming Software
22.9620.0194 Safety Cable Assembly
25.9661.0057 DMX Termination Connector Assembly
55.6840.0001 Truss Hook, Mega-Clamp, Round and Square
55.6841.0001 Truss Hook, Mega-Claw for 2” Round Tube
71.9708.1500 1500W Lamp, Philips MSR Gold 1500 FastFit*
Neutrik® powerCON TRUE1
AC Input Connector
1500W MSR Gold
Warranty Card
Product
Registration
Product Support
Sheet
QuickStart Guide
Truss Hook Brackets
(truss hooks sold separately)
Included Items
FastFit Lamp
(this document)
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 6
Connecting Power and Data
Connecting Power
The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. Current required depends on the AC supply voltage
and product model. Refer to “Current vs. Voltage” on page 7 for all models covered in this manual.
Note: The mating Neutrik® powerCON® True1 connector is supplied; however, you will need to purchase or construct a cable appropriate
for your application. Available power input cables is found in “Replacement Items/Accessories” on page 8.
Figure 2: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different connector. If required, install a new connector meeting
your requirements using the following wire color code reference:
WARNING: DO NOT connect to three-phase service in countries with 240 volt power. AVERTISSEMENT: NE PAS se connecter au
service en trois phases dans les pays avec puissance de 240 volts.
For single-phase power at 240 volts RMS:
For three-phase power at 200 volts RMS:
WARNING: It is not recommended to power any VARILITE luminaire from a dimmer - even in 'NONDIM' mode. Dimmer and non-dim
modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time, but will
eventually result in power problems, luminaire mis-operation and/or failure and may void the luminaire’s warranty. AVERTISSEMENT: Il
n'est pas recommandé pour alimenter un luminaire VARILITE d'un gradateur - même en mode 'NONDIM’. Modules de gradation et non
sombres ne sont pas des sources appropriées de pouvoir parce que leur production modifie la forme d'onde AC. Cela peut fonctionner
pendant une courte période, mais finira par entraîner des problèmes d'alimentation, luminaires mauvais fonctionnement et / ou l'échec et peut
annuler la garantie de l'appareil.
Wire* Connection
Green/Yellow AC Ground
Blue AC Neutral
Brown AC Line
* International (Harmonized) Standard
Connection Pin
AC Neutral X
AC Line Y
Ground (Earth) G
Connection Pin
Phase 1 X
Phase 2 Y
Ground (Earth) G
AC Power Input
3-Pole Neutrik® powerCON TRUE1 for AC Input Power
Neutrik® powerCON TRUE1
AC Input Connector
X
Y
G
X
Y
G
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
7 27 April 2017 02.9708.0001
Current vs. Voltage
Table 1-2, VL6000 Beam Luminaire - Current vs. Voltage (1500W Lamp) provides the luminaire’s current draw at specific voltages.
Total Luminaire Current is calculated with the lamp on and all motors sequencing.
WARNING: It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not
overload circuits. AVERTISSEMENT: Il est de la responsibilité de l'utilisateur de protéger adéquatement la source d'alimentation avec une
taille correcte et le disjoncteur de type et surchargez pas les circuits.
Connecting Data
A maximum of 32 luminaires may be connected in any one DMX data link.
Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data
link path. Consult your console documentation for more information.
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of remaining luminaires in
link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the
same DMX chain may not function properly without termination.)
Figure 3: Data Link
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement.
Table 1-2: VL6000 Beam Luminaire - Current vs. Voltage (1500W Lamp)
AC Voltage @ 60Hz Total Luminaire Current (Motor + Lamp Current)
200V 10.5A
210V 10.1A
220V 9.7A
230V 9.3A
240V 8.9A
VL6000 Beam Luminaire Channel Requirements*
*As set by the luminaire’s menu system.
DMX512 Channels Description Menu Display
23 Channels 16-Bit Mode (default) 16
**DMX terminator required for last fixture on DMX line.
Data In
Termination**
Data Thru
AC In
AC In
AC In
Data Thru
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 8
Installation Procedures
Installing Lamp
In the event the lamp was packed separately during shipment, follow the procedure in this section.
WARNING: Disconnect fixture before relamping. AVERTISSEMENT: Déconnectez le projecteur avant que le changement de lampe.
WARNING: Hot Lamp. Luminaire must remain powered on for 5 minutes after dousing lamp. Do not open for 5 minutes after switching
off. AVERTISSEMENT: Lampe chaude. Le luminaire doit rester en marche pendant 5 minutes après avoir éteindre la lampe. Ne pas ouvrir
pendant 5 minutes après la coupure.
WARNING: Risk of exposure to excessive ultraviolet radiation. Do not operate without complete lamp enclosure in place or when lens is
damaged. AVERTISSEMENT: Risque d’exposition aux rayonnements ultraviolets excessifs. Ne pas faire fonctionner sans le boîtier
complet de lampe mis en place ou lorsque l’objectif est endommagé.
Note: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the
lamp to explode or reduce lamp life. If touched, use isopropyl alcohol and cotton cloth to thoroughly clean glass portion of lamp.
To install lamp:
Step 1. Ensure power is completely removed from luminaire.
Step 2. Remove lamp from shipping box.
Step 3. Set the luminaire head horizontally.
Step 4. Engage tilt lock to secure luminaire head in position.
Step 5. At back of luminaire, using #2 Phillips screwdriver, remove lamp socket cover by loosening the two quarter-turn captive
screws. Note: lamp socket cover is connected with a safety tether.
Figure 4: Lamp Socket Cover Removal
Lamp Socket Cover*
Quarter-Turn Screws
Lamp
Lamp Socket
Note: *lamp socket cover is connected with a safety tether
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
9 27 April 2017 02.9708.0001
Step 6. As shown in Figure 5, align lamp tabs with lamp socket.
Figure 5: Lamp Installation
Step 7. Install lamp fully into lamp socket, taking care not to touch lamp glass.
Step 8. Turn lamp clockwise to seat lamp into socket. Lamp base should be aligned as illustrated in Figure 6.
Figure 6: Installed Lamp
Step 9. Reinstall lamp socket cover. Make sure safety tether is completely encapsulated within lamp socket cover.
Step 10. Disengage tilt lock to allow luminaire head to move freely.
Step 11. Align lamp as described in “Align Lamp For Maximum Beam Irradiance” on page 10.
Lamp Socket Cover
Lamp*
Align tabs of lamp with
socket when installing*
*Note tabs on socket assembly. Align corresponding
tabs on lamp to tabs on socket as indicated.
Narrow Tab
Wide Tab
Note alignment of fully seated lamp
Lamp
Caution: Ensure lamp is
completely seated before
reinstalling lamp socket cover.
Attention: Assurer la lampe est
bien en place avant de réinstaller
couvercle de la prise de la lampe.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 10
Align Lamp For Maximum Beam Irradiance
After a new lamp is installed in the luminaire, it will be necessary to align the lamp to optimize the beam.
WARNING: Back of luminaire and alignment screws will be HOT during lamp operation. Wear gloves and/or use tools to prevent burns.
AVERTISSEMENT: Retour de luminaires et d'alignement vis sera chaud pendant le fonctionnement de la lampe. Porter des gants et / ou
utiliser des outils pour éviter les brûlures.
To align lamp:
Step 1. Set intensity to 100%.
Step 2. Position beam on a white wall at a distance of 10 to 20 feet.
Step 3. Using console or internal luminaire menu controls, focus to a hard edge. Be sure that beam-size iris is completely opened.
Step 4. Using three alignment screws (as indicated with Red Arrows in Figure 7) adjust hot spot to center of beam.
Step 5. Check color uniformity as follows:
a. Position 60% magenta filter (Wheel 1) in Beam.
b. Verify that beam color is uniform (if lamp is misaligned, color will be concentrated to one side of beam). If color is not
uniform, readjust lamp using lamp alignment screws until color is uniform across entire beam field.
Figure 7: Lamp Alignment Screws
Rear of Luminaire
Lamp (Beam)
Alignment Screws*
*Lamp Socket Cover removed
for clarity. It is not necessary to
remove Lamp Socket Cover to
align lamp.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
11 27 April 2017 02.9708.0001
CAUTION: To prevent overheating, maintain a distance of 8.0mm between lamp and rear aluminum housing as illustrated in Figure 8.
ATTENTION: Pour éviter une surchauffe maintenir une distance de 8.0mm entre le lampe et le couverture arriére comme illustré dans
Figure 8.
Figure 8: Lamp Adjustment
Floor Mounting the Luminaire
All luminaires included in this manual are designed to sit directly on its base in a floor installation application. When used in this type of
application, be sure to leave enough space around the luminaire to allow proper, uninterrupted airflow for cooling and movement.
8.0mm
SECTION SIDE-SIDE
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 12
Hanging the Luminaire
The VL6000 Beam Luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this
moving luminaire. Two mounting truss hooks or other mounting hardware are required. Many compatible truss hooks are available from
different manufacturers for your particular needs.
A minimum of two hooks per luminaire is required. If mounting method does not use truss hooks, two attachment points, per luminaire, are
required.
Install mounting hardware and brackets:
Step 1. Install truss hooks on two provided truss hook brackets as
required as shown in Figure 9.
Note: Various types of truss hooks can be used. The Mega Claw truss hook
(as shown in the example above) as well as many other standard hooks, can
be ordered separately.
Step 2. Determine required configuration of bracket installation.
Brackets may be installed in many different orientations as
shown in Figure 10.
Step 3. While pulling up on locking mechanism release, fit keyed
holes onto raised mounting buttons at bottom of enclosure.
Slide forward and release locking mechanism to lock in
place. Ensure brackets are locked securely.
WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the luminaire. AVERTISSEMENT:
Assurez-vous que le mécanisme de support de verrouillage est complètement inséré après le support est installé sur l'appareil.
Figure 10: Installing Brackets on Luminaire Enclosure
Mount Bracket
Mega Claw Truss Hook
(not provided)
Truss Hook Hardware
(not provided)
Example Truss
Hook Installation
Figure 9: Truss Hook Installation
Press up to
Locked
install or release
Locking
Mechanism
Example Truss Hook and Mounting Hardware (not included, sold separately)
Mount
Bracket
Locking
Mechanism
Raised Mounting Buttons (8 each)
Keyed Hole
Mount Bracket*
Fit bracket’s keyed hole and locking mechanism
over raised mounting buttons and slide forward
to lock.
Brackets
Bracket
Orientation
Example Bracket
Orientations
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
13 27 April 2017 02.9708.0001
Installing in Truss:
Step 1. Using two people, lift luminaire into mounting position.
Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and
that luminaire is fully supported.
Step 3. Attach safety cable (as required) as follows (refer to Figure 11):
a. Loop safety cable at least once around safety cable anchor point rod.
b. Loop safety cable at least once around truss/pipe and secure around pipe.
Figure 11: Safety Cable Installation / Luminaire Hanging
Step 4. Make sure tilt and pan locks are disengaged so luminaire moves freely.
Step 5. Connect power and data cables according to procedure given in “Connecting Data” on page 7.
When hanging the luminaire in a side hang position, orient the enclosure as shown in Figure 12. Natural convection and the designed
direction of the inlet and exhaust cooling fans dictate that the inlet should be closest to the floor and the exhaust should be towards the
23.8”
(60.5 cm)
23.8”
(60.5 cm)
24.5”
(62.2 cm)
25.9”
(65.9 cm)
NOTE: The safety cable anchor point is tested and is in compliance
of the following safety standards:
- IEC / EN 60598-2-17.6.6
- UL1573
Safety Cable Anchor Point
(see note)
Note, truss hooks shown are sold separately. Truss and pipe by others.
Safety Cable Anchor Point
Safety Cable: Recommended for hanging installations. May be required by local codes. Safety cable is sold
separately.
Câble de sécurité: Recommandé pour les installations pendaison. Peut être exigé par les codes locaux.
Câble de sécurité est vendu séparément.
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 14
ceiling. This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next to it when the luminaires are
side-by-side.
Figure 12: Side Hang Orientation
If the luminaires are stacked on top of one another in a side hang, a 45° enclosure orientation with the fan inlet closest to the floor is
preferred. Refer to Figure 13.
These two orientations in a side hang have the extra benefit of a stiffer pan interface in the luminaire.
Figure 13: Dual Fixture Side Hang Orientation
REAR VIEW
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
15 27 April 2017 02.9708.0001
Menu Operation
LCD Display and Menu System
The VL6000 Beam Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings:
Address – to set the DMX address
Configure – various parameter settings, set luminaire ID
Fixture – fixture status, recalibrate, reboot, software version, view fixtures hours, etc.
DMX – change the map, set address, invert pan/tilt
Service – password protected factory service menu
Manual – manual control of parameters
Test – test functions of parameters
The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple luminaires in a system, any
settings or changes would need to be made at each LCD Menu as desired.
Menu Controls
The menu system is controlled by an OK (Enter), ESC (Escape), and four Arrow () buttons. These buttons function are shown in
Figure 14.
Figure 14: Menu Control
LCD Display and Menu System Operation
The LCD Display Menu system consists of several categories. Use the Menu Buttons to access and make changes to the menu items. When
the desired menu item is reached, press the desired Menu Button to display the menu options and to navigate and configure the menu options
as required.
To navigate and access menu settings/selections:
Step 1. Make sure unit is powered and turned on.
Step 2. Press [ESC] to access menu categories.
Step 3. Use four Arrow () buttons to navigate through the various options and settings.
Step 4. Once menu item is reached, press OK [Enter] to access the menu item parameters.
Step 5. Make changes to parameters as desired.
Step 6. Press OK [Enter] button to accept changes.
ESC
OK
LCD Display
OK (Enter) Button
To Select or Change a
Setting or Data Value
Escape (ESC)
Used to Access Main Menu Parameters,
Exit, or Return to Previous Menu Item
Arrow Keys (Up/Down/Left/Right)
Menu Navigation / Data Selection
Displays all Data and
LCD Menu Proximity Sensor
Automatically enables the menu display (turn on
the backlight) as you reach for the front panel.
Luminaire Settings
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 16
DMX Address
To set, edit, and save a DMX address:
Step 1. Press [ESC].
Step 2. Press [Up] / [Down] arrows until Address (DMX Address) appears. Press OK [Enter].
Step 3. Use [Left] and [Right] arrow buttons to scroll through all digits.
Step 4. Once at desired digit, use [Up] and [Down] arrows to change highlighted digit.
Step 5. Once digit is set, use [Left] and [Right] arrow buttons to set other digits in DMX address.
Step 6. Once all digits are set in DMX address, press OK [Enter] to set.
Step 7. DMX will display and is saved.
Other LCD Display Features
LCD Menu Battery Operation
The LCD menu system utilizes a battery powered system for operation when the luminaire is not connected to power. The primary purpose of
this mode is to allow basic setup and configuration of the luminaire.
To enable the battery operation of the menu system:
Step 1. Press and hold [ESC] and [OK] for two seconds.
Step 2. Once enabled, the menu will function as normal with only the following sub-menu sections active:
Address
• Configure
• Setup
• DMX
• Fixture
Note: Any commands that require full power (calibrate, lamp strike, etc.) will be ignored while the menu system is in battery operation
mode.
Step 3. To exit battery mode, press and hold [ESC] and [OK] for two seconds. Note, luminaire will automatically exit this mode after
one minute of inactivity.
Status Bar
The Status Bar (as illustrated in Figure 15) is present at all times and displays luminaire
operational information of the luminaire. The Status Bar contains the following
information:
LAMP – indicates current lamp state - ON or OFF.
SHDN – indicates shutdown time in hours. NO indicates no shutdown time.
ERRORS – Displays a number indicating the total amount of current errors; can
cycle through short text descriptions of each error. Example: “Pan” or “Gobo1”.
When errors are present, messages will appear in red text. When no errors are
present, NO will display.
ADDR – Displays the current DMX address for the fixture. NOTE, when the
fixture does not detect a DMX input signal, the DMX address text will display in
red text.
LCD Menu Proximity Sensor
The LCD menu system uses a proximity sensor to automatically enable the menu display (turn on the backlight) as you reach for the front
panel. If the display is off, it will turn on when your hand is within a few inches of the display. Note, when the luminaire is not connected to
power and the LCD menu is operating on battery, this proximity sensor is disabled.
Figure 15: LCD Display Status Bar
OFF
LAMP
NO
ERRORS
NO
SHDN
001
ADDR
VL6000B Luminaire
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
17 27 April 2017 02.9708.0001
Quick Reference DMX Map
The summary list for the 16-Bit Mode DMX map is as indicated below.
16-Bit VL6000 Beam Luminaire DMX Channel Summary Listing
DMX
Channel Description
DMX
Channel Description
1 Intensity 13 Color Wheel 3
2, 3 Pan 14 Color Wheel 3 Control
4, 5 Tilt 15 Gobo Wheel 1
6 Edge 16, 17 Gobo 1 Rot/Index
7 Color Wheels Presets 18 Gobo Wheel 1 Control
8 Color Transition 19 Iris
9 Color Wheel 1 20 Frost
10 Color Wheel 1 Control 21 Strobe Speed
11 Color Wheel 2 22 Strobe Control
12 Color Wheel 2 Control 23 Luminaire Control
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
02.9708.0001 27 April 2017 18
Notes
VARILITE - VL6000 BEAM LUMINAIRE QUICKSTART GUIDE
19 27 April 2017 02.9708.0001
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Vari-Lite VL6000 BEAM Guide de démarrage rapide

Catégorie
Stroboscopes
Taper
Guide de démarrage rapide

dans d''autres langues