Briggs & Stratton 074000-0 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur

Ce manuel convient également à

Model / Modèle / Modelo
074000
Operator’s Manual
Manuel d’utilisation
Manual del Operario
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin d'aller
loin pour trouver de l'aide!
Preguntas? La ayuda es justa un momento lejos!
Call: Helpline
Appelez: Ligne d'assistance
Llame: Línea Directa
1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Manual No. 198853GS
Revision 0 (11/15/2005)
Before using this product, read this
manual and follow all Safety Rules and
Operating Instructions.
WARNING
Antes de utilizar el producto, lea este
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
ADVERTENCIA
Avant d’utiliser ce produit, veuillez lire
le manuel et suivre toutes les directives
relatives à la sécurité et à l’utilisation.
AVERTISSEMENT
2
DESCRIPTION / SAFETY RULES
TABLE OF CONTENTS
Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Espanõl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
EQUIPMENT DESCRIPTION
This manual contains operation and maintenance information
for a single stage air compressor that produces 4.9 CFM at
40 PSI (2.8 bars) and 3.6 CFM at 90 PSI (6.2 bars) using a
120 Volt A.C. electric motor.This high quality system features
a direct drive oil lube pump with cast iron sleeve, an easy
start valve, and a motor overload protection feature with
manual restart.
Every effort has been made to ensure that information in this
manual is accurate and current. However, we reserve the right
to change, alter or otherwise improve the product and this
document at any time without prior notice.
Statement of Use
This air compressor has been manufactured to provide an
adequate volume of compressed air for operating a variety of
light-duty air tools (hand grinders, nailers, ratchets, or
staplers), spraying equipment, and inflators requiring less than
4.9 CFM air flow for operation. Operate this compressor
ONLY in an ambient temperature range from 32
°
to 95
°
F
(0
°
to+35
°
C).This compressor is designed for a maximum of
70% duty per hour at full load.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates a
hazard which, if not avoided, will result in death or serious
injury.WARNING indicates a hazard which, if not avoided,
could result in death or serious injury. CAUTION indicates a
hazard which, if not avoided, might result in minor or
moderate injury. CAUTION, when not used with the safety
alert symbol ( ), indicates a situation that could result in
equipment damage. Follow safety messages to avoid or reduce
the risk of injury or death.
Hazard Symbols and Meanings
Copyright © 2005 Briggs & Stratton Power Products Group, LLC.All
rights reserved. No part of this material may be reproduced or
transmitted in any form by any means without the express written
permission of Briggs & Stratton Power Products Group, LLC.
SAVE THESE INSTRUCTIONS
Fire
Auto-start
Explosion
Compressed Air
InhalationHot Surface
Electrical Shock
Flying Objects
Air Injection
3
SAFETY RULES
Before using this product, read this Operator’s Manual and
follow all Safety Rules and Operating Instructions listed.
Make this manual available to other users of this equipment.
Failure to read and follow instructions in manual
can result in death, bodily injury and / or property
damage.
WARNING
DO NOT use grounding adapters. Inspect cord before each use.
DO NOT operate with protective covers / guards removed or
damaged.
DO NOT operate in wet conditions. Store unit indoors.
Disconnect from power source and drain pressure from tank
when not in use or before servicing.
DO NOT modify the plug provided. If it does not fit the
available outlet, a qualified electrician should install a proper
outlet.
A qualified electrician MUST make repairs to the cord set or
plug.
Contact with compressor or its cord can cause
electric shock or burn.
Improper grounding can result in electrical shock.
Contact with components under protective cover
can cause electric shock or burn.
WARNING
DRAIN TANK after every 4 hours of use or daily by opening
drain fitting(s) and tilting compressor to empty accumulated
water.
DO NOT modify or repair tank in any way.
DO NOT adjust pressure greater than maximum rating of
attachments or inflatables.
DO NOT tamper with or remove ASME Safety Valve. Check
ASME Safety Valve by pulling ring before each use.ASME Safety
Valve has been set to maximum safe rating.
Hidden internal tank corrosion can cause violent
explosion leading to severe injury and / or
property damage.
Exceeding pressure rating of attachments or
inflatables can cause severe injury and / or
property damage.
Tampering with or removing ASME Safety Valve
can cause explosion leading to severe injury
and / or property damage.
WARNING
DO NOT spray flammable or combustible liquids while smoking,
near sparks, open flames, pilot lights, any ignition source, or in
confined areas.
Spray in an open, well ventilated area at least 20 feet
(6.1 meters) away from compressor or other ignition source.
Spraying flammable or combustible liquids can
cause fire or explosion.
Compressor produces sparks during operation,
which can ignite flammable or combustible vapors.
WARNING
SAFETY RULES
4
This procedure is required before the air compressor is put into
service and when the Check Valve or a complete compressor
pump has been replaced.
Serious damage may result if the break-in instructions are
not closely followed.
CAUTION
Damage to equipment resulting from failure to follow this
instruction will void warranty.
Serious damage may result if operating the unit with
insufficient oil. Check oil level daily or with each use.
CAUTION
DO NOT touch compressor or tubing.
Allow compressor to cool before servicing.
Operating air compressor and tubing are HOT
and can cause burns.
WARNING
STAY CLEAR
Disconnect from power source and drain pressure from tank
when not in use or before servicing.
Compressor can start any time when plugged in.
WARNING
DO NOT direct air stream at self or others.
DO NOT attempt to repair air hose(s).
Always wear ANSI Z87.1 approved safety glasses with side
shields.
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
WARNING
DO NOT use compressed air for breathing.
Always use NIOSH respirator approved for your application
when spraying.
Read all instructions with respirator so you are certain it will
provide necessary protection against inhaling harmful vapors.
Compressed air is not breathable and can cause
bodily injury.
Some paints or solvents may be harmful if inhaled
or ingested, causing severe nausea, fainting or
poisoning.
WARNING
5
ASSEMBLY
Carton Contents
Air compressor
Operator’s Manual
Bottle of Compressor Pump Oil
Oil Dipstick
If any parts are missing, call the air compressor helpline at
1-800-743-4115.
Your compressor is ready for use when:
Properly serviced with supplied oil
Connected to a suitable power source
Completed Break-In Procedure
Unpacking
1. Remove accessories and packing from carton.
2. Lift unit out of carton.
Also Recommended for Use:
Safety glasses (ANSI Z87.1 approved safety glasses with
side shields)
Air hose - 25 ft (7.6M), 3/8 inch diameter
Quick connector fitting - Use type I/M quick connect
fittings that attach to 1/4 inch NPT thread
Hearing protection (ANSI S3.19-1974) in noisy
environments
Respirator (NIOSH-approved) in dusty environments
Oil funnel
ASSEMBLY
FEATURES AND CONTROLS
6
Air Compressor Pump: Pump compresses air into tank.
Check Valve: When unit is operating, Check Valve is open,
allowing air to enter tank.At “cut-out” pressure, Check Valve
closes, preventing air from flowing back into pump.Valve is
not serviceable by user.
Data Tag: (not shown) The data tag contains serial number,
model number, and revision number information.
Drain Valve: Valve is located near bottom of air tank and is
used to drain condensation.
Overload Protector: If motor overheats, overload
protector shuts motor off. See MAINTENANCE.
Oil Fill Location: Oil level dipstick indicates pump oil level.
ON - OFF Switch: Pull to ON position to power air
compressor. Push to OFF position to remove power.
Outlet Pressure Gauge: Indicates air pressure at Quick
Connect Fitting.
Pressure Control: Controls air pressure delivered to Quick
Connect Fitting; can be secured with locking ring.
Pressure Release Valve: (not shown) Located on top of
tank adjacent to Quick Connect Fitting, valve automatically
releases air from internal compressor components at “cut-
out” pressure or when unit is shut off.Valve is not serviceable
by user.
Pressure Switch: Automatically starts motor when tank
pressure drops below “cut-in” pressure and stops motor
when pressure rises to “cut-out” pressure.
Quick Connect Fitting: Connect air tools here.
Safety Valve: Valve protects against excessive tank pressure
by ‘popping out’ at its factory setting, thus relieving pressure.
Tank Pressure Gauge: Gauge indicates air pressure within
air tank.
NOTE: See GLOSSARY on page 18 for definitions.
Drain Valve
Air Compressor Pump
Pressure Control
Oil Fill Location
FEATURES AND CONTROLS
Read this Operator’s Manual and safety rules before operating your compressor.
Compare this illustration with your air compressor to familiarize yourself with the location of various controls and
adjustments. Save this manual for future reference.
Overload Protector
Outlet Pressure Gauge
ON - OFF Switch
Pressure Switch
Safety Valve
Check Valve
Tank Pressure Gauge
Air Filter
Quick Connect Fitting
OPERATION
Add Oil
1. Place compressor on a flat, level surface.
2. Remove and discard the shipping cap. Using an oil funnel,
slowly fill pump with oil to notch on dipstick (See
Figure 1).
3. Insert the dipstick. and check oil level. Oil level should be
at the notch in the dipstick. Replace dipstick.
Break-In Procedure
Before first use of this equipment, the system must undergo a
break-in operation, as described in this section.
1. Make sure ON - OFF switch is in OFF position
(see Figure 2).
2. Plug power cord into grounded 120 Volt A.C. outlet (see
Grounding Instructions on page 8).
3. Open Drain Valve (rotate fully counterclockwise) to
prevent air pressure build-up in air tank during break-in
period (see Figure 3).
NOTE:Always drain air tank over a washable surface or in a
suitable container to prevent damaging or staining surfaces.
4. Pull ON - OFF switch to ON position. Compressor will
start.
NOTE: If you hear leaking air, pull quick connect coupler
back until it clicks to reset coupler valve.
5. Run compressor for 15 minutes. Make sure Drain Valve
remains open.
6. After 15 minutes, close Drain Valve (rotate fully
clockwise).Air tank will fill to “cut-out” pressure and
compressor will stop.
NOTE: Check oil level in compressor after break-in.
The compressor has completed the break-in procedure and is
ready for normal use.
7
OPERATION
Figure 2 - Pressure Switch with ON - OFF Switch
This procedure is required before air compressor is put into
service and when Check Valve or a complete Air Compressor
Pump has been replaced.
Serious damage may result if the described break-in
instructions are not closely followed.
CAUTION
CAUTION
Damage to equipment resulting from failure to follow this
instruction will void warranty.
Serious damage may result if operating the unit with
insufficient oil. Check oil level daily or with each use.
Figure 3 - Drain Valve in OPEN Position
ON - OFF Switch
shown in OFF
position
Drain Valve
shown in
OPEN
position
Figure 1 - Oil Fill Information
Drain Plug
Oil Fill
Location
MAXIMUM
Oil Level
PROPER
Oil Level
Inset of
Dipstick
Air Compressor Operating Location
Locate the air compressor in a clean, dry and well-ventilated
area for operation.The air compressor should be placed at
least 12 inches (30 cm) away from walls or other
obstructions that could interfere with airflow.
The Air Compressor Pump and shroud are designed to allow
for proper cooling.The ventilation openings on the
compressor are necessary to maintain proper operating
temperature. DO NOT place rags or containers on or near
these openings. Keep the Air Filter clear of obstructions that
could reduce airflow to the air compressor.
Operate the air compressor with unit located on a flat
surface to ensure that it receives proper lubrication.
If you have any problems with operation of your air
compressor, call air compressor helpline at 1-800-743-4115.
If calling for assistance, please have the model, revision, and
serial number from the data tag available.
Grounding Instructions
1. The cord set and plug supplied with this unit contains a
grounding pin.This plug MUST be used with a grounded
outlet.
2. Make sure power outlet being used has same
configuration as air compressor’s plug (see Figure 4).
DO NOT use a ground adapter.
3. Inspect plug and cord before each use. DO NOT use
compressor if there are signs of damage.
IMPORTANT: If these grounding instructions are not
completely understood, or if in doubt that air compressor is
correctly grounded, have installation checked by a qualified
electrician.
Starting Your Air Compressor
1. Make sure ON - OFF switch is in OFF position.
2. Plug power cord into grounded 120 Volt A.C. outlet
(see Figure 4).
3. Turn PRESSURE CONTROL knob counterclockwise until
knob turns without resistance (see Figure 5).
4. Pull ON - OFF switch to ON position. Compressor will
start.
NOTE: If the motor fails to start, refer to
TROUBLESHOOTING on page 16.
NOTE: If you hear air leaking, pull quick connect coupler
back until it clicks to reset coupler valve.
The air compressor is fully automatic and is controlled by the
pressure switch.The compressor will run until pressure in the
air tank reaches cut-out pressure.The compressor will restart
when pressure in the air tank falls below the cut-in pressure.
See GLOSSARY on page 18 for definitions.
NOTE: Always operate the air compressor in well-ventilated
areas free of gasoline or other flammable/combustible vapors.
If the compressor is being used to spray volatile chemicals
(such as paint), locate the compressor at least 20 feet
(6.1 meters) away from the spray area.
OPERATION
8
Figure 5 - Pressure Control Knob and ON - OFF Switch
Pressure Control Knob
DO NOT use grounding adapters.
Do not modify the plug provided. If it does not fit the
available outlet, a qualified electrician should install a
proper outlet.
A qualified electrician MUST make repairs to the cord set
or plug.
Improper grounding can result in electrical shock.
WARNING
Figure 4 - Correctly Rated 15 AMP Power Duplex Outlet
ON - OFF Switch
9
OPERATION
Stopping Your Air Compressor
1. Push ON - OFF switch to OFF position. Compressor
motor will stop.
2. If finished using compressor, unplug compressor’s power
cord from outlet.
3. Pull Safety Valve ring to release most of tank’s
compressed air. Release valve ring.
4. Open Drain Valve to fully drain air tank.
NOTE:Always drain air tank over a washable surface or in a
suitable container to prevent damaging or staining surfaces.
NOTE: The compressor generates condensation water
(condensate) that accumulates in the air tank. Drain the
condensate every 4 hours or daily.
5. Close Drain Valve.
Extension Cords
NOTE:Avoid use of extension cords.
The air compressor should be located where it can be
directly plugged into a grounded outlet. DO NOT use an
extension cord unless absolutely necessary. Instead, increase
the working reach of the air hose by attaching two or more
air hoses together.
If the use of an extension cord cannot be avoided, use these
guidelines:
Use only a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot outlet that will accept the plug
from the air compressor.
Make sure the cord is in good condition.
When compressor is used outdoors, use only extension
cords marked “Intended for Outdoor Use”.
Follow these length restrictions:
Distance Needed
. . . . . . . . . . . . . . . . . . Recommended Gauge
Less than 25 ft. (7.5 M). . . . . . . . . . . . . . . . . . . . . . . . 12 AWG
25 to 50 ft. (7.5 to 15 M) . . . . . . . . . . . . . . . . . . . . . . 10 AWG
More than 50 ft. (15 M) . . . . . . . . . . . . . . Not Recommended
Compressor Operation
You do not have to use the maximum operating pressure at
all times because the air tool being used often requires less
pressure. Here are general guidelines for setting pressure.
1. With air compressor connected to proper power and
turned ON, attach desired air tool or accessory to quick
connect fitting. Use recommended air hose and quick
connect fitting.
2. Activate air tool and turn Pressure Control knob
clockwise to increase outlet pressure.
3. Observe OUTLET PRESSURE GAUGE and adjust
pressure to recommended setting of accessory tool.
NOTE:You must adjust outlet air pressure while tool is
operating or activated.
4. Use lock ring on Pressure Control to lock in selected
pressure setting by tightening it against Pressure Control
knob.
5. Always operate this unit on a level surface to avoid
lubrication problems.
Overload Protection Reset
This compressor is equipped with an overload protection
feature that protects the motor if it overheats. If the
compressor motor overheats and trips this circuit breaker,
wait 15 minutes for the motor to cool.Then push the
RESET button located on the motor shroud (see Figure 6).
Also see the TROUBLESHOOTING on page 16 for more
information
Observe these safety precautions when operating air
compressor:
OPERATION
10
DO NOT use grounding adapters. Inspect cord before each use.
DO NOT operate with protective covers / guards removed or
damaged.
DO NOT operate in wet conditions. Store indoors.
Disconnect from power source and drain pressure from tank
when not in use or before servicing.
Contact with compressor or its cord can cause
electric shock or burn.
Compressor must be grounded.
WARNING
DO NOT adjust pressure greater than maximum rating of
attachments or inflatables.
Exceeding pressure rating of attachments or
inflatables can cause severe injury and/or property
damage.
WARNING
DO NOT touch compressor or tubing.
Allow compressor to cool before servicing.
Operating air compressor and tubing are HOT
and can cause burns.
WARNING
STAY CLEAR
Disconnect from power source and drain pressure from tank
when not in use or before servicing.
Compressor can start any time when plugged in.
WARNING
DO NOT use compressed air for breathing.
Always use NIOSH respirator approved for your application
when spraying.
Read all instructions with respirator so you are certain it will
provide necessary protection against inhaling harmful vapors.
Compressed air is not breathable and can cause
bodily injury.
Some paints or solvents may be harmful if inhaled
or ingested, causing severe nausea, fainting or
poisoning.
WARNING
DO NOT direct air stream at self or others.
Always wear ANSI Z87.1 approved safety glasses with side
shields.
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
WARNING
Figure 6 - Overload Protection RESET Button
RESET Button
SPECIFICATIONS / MAINTENANCE
11
PRODUCT SPECIFICATIONS
MAINTENANCE
To ensure efficient operation and longer life of the air
compressor, prepare and follow a routine maintenance
schedule.The routine described in this section is intended for
an air compressor used under normal daily working
conditions. If necessary, modify the schedule to suit the
conditions under which you use your compressor.
Modifications will depend upon hours of operation and
working environment. Operating air compressors in
extremely dirty or hostile environments will require more
frequent maintenance checks.
NOTE: See FEATURES AND CONTROLS and OPERATION
for control locations.
Follow the hourly or calendar intervals, whichever occurs
first:
Maintenance
Schedule
Service Intervals
Service Dates
Fill in as you complete
regular service
Maintenance Task Daily Weekly
Every 50 Hours
or Yearly
Every 100 Hours
or Yearly
Inspect Safety Valve X
Inspect Fittings/Valves X
Inspect Oil Level X
Clean Unit X
Inspect and Clean Air
Filter
X
Inspect Pump Oil X*
Inspect Intake and
Exhaust Valves
X**
Inspect Safety Labels X***
* Change oil after first 100 hours of operation, then every 300 hours thereafter
** Return unit to approved repair center annual for inspection and service
*** Inspect annually, replace as necessary
AC Frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Hz
Rated AC Voltage: . . . . . . . . . . . . . . . . . 120 Volts, single phase
Running Horsepower: . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 HP
Pump Type: . . . . . . . . . . . . . . . . . . Oil Lubricated Direct Drive
Lubricant:. . . . . . . . . . . . . . . . . . . . . . . . . SAE 5W50 Synthetic
Oil Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . 7.168 oz. (200ml)
Air Delivery:
At 40 psi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 CFM
At 90 psi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 CFM
Cut-In Pressure Setting: . . . . . . . . . . . . . . . . . 80 psi (5.6 bars)
Cut/Out Pressure Setting: . . . . . . . . . . . . . . 125 PSI (8.7 bars)
Tank capacity: . . . . . . . . . . . . . . . . . . . . . . . . 6 Gallons (22.5 L)
Tank Style: . . . . . . . . . . . . . . . . . . . . . . . . Flat, single (Pancake)
Recommended Air Hose Size: . . . . . . . . . 3/8 inch ID (14mm)
Air Fittings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 inch NPT
Quick Connect Fitting Type: . . . . . . . . . . . . . . . . . . . . . . . . I/M
Operating Temperature Range: . . . 32
°
to 95
°
F (0
°
to+35
°
C)
Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . 60lbs. (27.3 Kg)
Inspect Safety Valve
1. Pull ring on Safety Valve (see Figure 7) and observe that
Safety Valve operates freely.
2. If valve is stuck or does not operate smoothly, it must be
replaced with same type of valve.Take unit to authorized
service facility for repair.
Inspect Quick Connect Fitting and
Tank Drain Valve
1. Push ON - OFF switch to OFF and unplug unit.
2. Disconnect air tool or accessory from unit.
3. Pull ring on Safety Valve to reduce air pressure. Release
Safety Valve ring.
4. Open drain valve (turn fully counterclockwise, see
Figure 3, earlier) and permit accumulated water to be
discharged.Valves should operate smoothly and have full
range of operation.
5. After water has drained, close Drain Valve fully clockwise.
NOTE: If Drain Valve is plugged, pull Safety Valve ring to fully
drain air from tank. Remove, clean and reinstall Drain Valve
using pipe thread sealant.
Inspect / Change Pump Oil
Checking Oil Level
Use these steps to check oil level:
1. Push ON - OFF switch to OFF and unplug unit.
2. Place unit on a flat, level surface.
3. Remove oil dipstick and wipe dipstick with clean cloth.
4. Reinstall dipstick into oil fill opening.
5. Carefully remove dipstick and verify that oil level is at
proper level (see Figure 8).
6. If oil level is too low, add recommended oil to proper
level (see Figure 8). If oil is above MAXIMUM Oil Level,
drain excess oil, as described in next section.
7. Reinstall oil dipstick.
Changing Oil
At recommended oil change interval, follow these steps:
1. Push ON - OFF switch to OFF and unplug unit.
2. Place unit on a flat, level surface.
3. Remove oil dipstick and wipe dipstick with clean cloth.
4. Position a suitable container under drain plug to collect
drain oil.
MAINTENANCE
12
Figure 8 - Oil Fill Information
Drain Plug
Oil Fill
Location
MAXIMUM
Oil Level
PROPER
Oil Level
Inset of
Dipstick
Figure 7 - Safety Valve
DO NOT touch compressor or tubing.
Allow compressor to cool before servicing.
Operating air compressor and tubing are HOT
and can cause burns.
WARNING
DO NOT direct air stream at self or others.
Always wear ANSI Z87.1 approved safety glasses with side
shields.
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
WARNING
Safety Valve Ring
5. Use an adjustable wrench to remove hex head drain plug.
6. Fully drain oil into container. Install drain plug and tighten
using adjustable wrench. Dispose of used oil properly.
7. Using oil funnel, slowly add recommended oil. Check oil
level frequently with dipstick to avoid overfilling
Compressor Pump (see Figure 8).
8. When oil is at proper level, reinstall oil dipstick and wipe
up any spilled oil.
Cleaning Unit
To prolong compressor life, perform these steps weekly. If the
operating environment is particularly dirty, perform daily.
1. Push ON - OFF switch to OFF and unplug unit.
2. Use a soft cloth and a small brush for cleaning
accumulated dirt and debris from the following locations:
Louvers on left end of motor shroud (on opposite
end from Oil Fill Location, see Figure 9)
Cooling fins on top of Air Compressor Pump
Cooling fins on sides of Air Compressor Pump,
especially between sides of pump and shroud
Oil fill and adjacent area on air pump housing
Oil drain on air pump housing
Pressure Control knob, gauges, quick connect fitting,
and Safety Valve
General Maintenance
Keep your air compressor clean and dry by placing it in a
location far away from sources of contamination. Make sure
the unit is kept in a well-ventilated area. Protect hoses,
connectors, quick connects, and accessories from damage.
IMPORTANT: DO NOT use jets of water or flammable
liquids to clean unit.
Inspect / Clean Air Filter
Use the following steps to check and clean the compressor’s
internal air filter.
1. With air tank fully pressurized (ON - OFF switch in
ON position and motor stopped), push ON - OFF
switch to OFF position. Disconnect power cord from
outlet.
2. Use phillips screwdriver to remove screw holding air
filter cover and remove air filter cover (see Figure 10).
3. Remove air filter media.
IMPORTANT: DO NOT operate compressor with air filter
media removed.
MAINTENANCE
13
Figure 10 - Servicing Air Filter
Air Filter Media
Compressor
Filter Housing
Figure 9 - Cooling Fins
Shroud Louvers
Cooling Fins
DO NOT touch compressor or tubing.
Allow compressor to cool before servicing.
Operating air compressor and tubing are HOT
and can cause burns.
WARNING
4. If dirty, use compressed air to dislodge dirt from air filter
media.Also, blow debris out of air filter cover and
compressor filter housing (see Figure 10).
NOTE: DO NOT use liquid solvents to clean filter media.
5. Replace air filter media in compressor filter housing.
6. Position air filter cover over air filter media. Use phillips
screwdriver to secure cover with screw.
NOTE: Replace air filter media if it is extremely dirty.
Inspect Pump Intake and Exhaust
Valves
Once each year, certain internal compressor components
must be inspected. Have a trained service technician perform
this check, to include the air compressor pump intake and
exhaust valves.
Inspect Safety Labels
As often as desired or at least yearly, inspect all labels applied
to the air compressor.All safety labels should be present and
readable. If any safety label is missing or illegible, obtain a
replacement from an authorized service center or call the air
compressor helpline at 1-800-743-4115.
MAINTENANCE
14
DO NOT direct air stream at self or others.
Always wear ANSI Z87.1 approved safety glasses with side
shields.
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
WARNING
STORAGE
15
STORAGE
Before you store your air compressor, make sure you
perform the following:
1. Review MAINTENANCE beginning on page 11 and
perform scheduled maintenance as necessary.
2. Push ON - OFF switch to OFF and unplug unit.
3. Turn pressure control knob counterclockwise until knob
turns freely.
4. Remove air tool or accessory.
5. Pull ring on Safety Valve and drain air from air tank to
reduce air pressure. Release Safety Valve ring.
6. Drain remaining air and water from tank by opening
drain valve fully counterclockwise.
7. Rock unit forward and back to agitate water as it drains
to obtain a more thorough emptying action.
8. After water has been drained, close drain valve fully
clockwise.
9. Protect electrical cord and air hose from damage (such
as being stepped on or driven over).
10. Store air compressor in clean, dry, indoor location.
DO NOT direct air stream at self or others.
Always wear ANSI Z87.1 approved safety glasses with side
shields.
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
WARNING
16
TROUBLESHOOTING
Before You Call
If you have any problems with the operation of your air
compressor, please call the air compressor helpline at
1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number information printed on the
data tag available. (see Figure 11).
TROUBLESHOOTING
MODEL
REV NO
SERIAL NO
Figure 11 - Data Tag Information
Barcode
Barcode
Unit Information
PROBLEM CAUSE CORRECTION
Excessive tank pressure - Safety
Valve pops off.
Pressure Switch does not shut off motor
when compressor reaches “cut-out”
pressure or “cut-off” setting too high.
Move ON - OFF Switch to OFF position.
Contact trained service technician.
Air losses
1. Quick Connect Fitting cracked or
loose.
2. Check Valve seat dirty or damaged.
3. Defective pressure switch release
valve.
4. Defective air tank.
5. Leaking seal.
6. Damaged regulator.
1. Tighten Quick Connect Fittings where
air can be heard escaping. Replace
fittings.
2. Contact trained service technician.
3. Contact trained service technician.
4. Air tank must be replaced. DO NOT
REPAIR TANK.
5. Contact trained service technician.
6. Contact trained service technician.
Knocking noise
Safety Valve dirty or defective.
Operate Safety Valve manually by pulling on
ring. If valve still leaks, have it replaced at an
authorized service center.
17
TROUBLESHOOTING
PROBLEM CAUSE CORRECTION
Compressor is not
supplying enough air to
operate accessories.
1. Prolonged excessive use of air.
2. Compressor is not large enough for air
requirement.
3. Hole in hose.
4. Check Valve restricted or leaks air.
5. Restricted air intake filter.
1. Decrease amount of air used.
2. Check the accessory requirement. If it is
higher than the CFM or pressure supplied by
your air compressor, you need a larger
capacity air compressor.
3. Inspect and replace if required.
4. Contact trained service technician.
5. Clean or replace air intake filter
(see page 13).
Motor will not run.
1. Motor Overload Protector switch has
tripped.
2. Tank pressure exceeds Pressure Switch
“cut-in” pressure.
3. Loose electrical connections.
4. Possible defective motor or starting
capacitor.
5. Pressure Release Valve on Pressure
Switch has not unloaded head pressure.
6. Fuse blown, circuit breaker tripped.
1. Let motor cool for 15 minutes. Press RESET
to reset Overload Protector switch.
2. Motor will start automatically when tank
pressure drops below “cut-in” pressure
setting.
3. Contact trained service technician.
4. Contact trained service technician.
5. Drain pressure by setting ON - OFF Switch
to OFF. If the Pressure Release Valve does
not open, contact trained service technician.
6A. Check fuse box for blown fuse and replace as
necessary. Reset circuit breaker. DO NOT use
a fuse or circuit breaker with higher rating
than that specified for that branch circuit.
B. Check for proper fuse. Use a time delay fuse.
C. Check for low voltage conditions and/or
proper extension cord.
D. Disconnect all other electrical loads from
circuit used by air compressor OR operate
air compressor on dedicated branch circuit.
Contact trained service technician.
18
GLOSSARY
GLOSSARY
Becoming familiar with these terms will help you understand
and operate most air compressors:
Air Delivery A combination of psi and CFM.The air
delivery required by a tool or accessory is stated as
“’number’ (S)CFM at ‘number’ psi”. For example “4.9 CFM at
90 psi”.The combination of these values dictates the required
air compressor capacity.
Air Tank Capacity The volume of air stored in the tank
and available for immediate use.
Alternating Current (AC) - Voltage that increases to a
maximum positive value (+) and falls back to zero and then
continues to a maximum negative value (-) and back to zero.
This cycle is repeated 60 times each second for 60 hertz AC
power.
ASME Certified - Indicates that the pressure vessel (air
tank) and related components are manufactured, tested, and
inspected to the specifications set by the American Society of
Mechanical Engineers.
ASME Safety Valve - A protection device that automatically
releases tank air if the air contained within exceeds a preset
maximum rating.
Cast Iron Sleeve - A thin iron cylinder cast into the
cylinder head, producing a harder surface between the
aluminum cylinder walls and steel piston rings, thus extending
the life of the compressor.
CFM or SCFM (Standard Cubic Feet per Minute). SCFM is
the volume of air, in cubic feet, that the compressor can pump
in one minute at a specific working pressure.The term CFM
is used in this manual.
Circuit Breaker - A thermal switch that opens a circuit if
too much current is passing through it.The air compressor
motor is protected by this resettable device.
Cut-In Pressure As air is taken from the air tank, the tank
air pressure drops.At a certain low level, the Pressure Switch
senses this low pressure and turns-on the compressor motor,
thus refilling the air tank.The level at which the motor
switches ON is called the Cut-In Pressure.
Cut-Out Pressure While the compressor is running, air is
being produced and stored in the air tank. If no air is being
used, air pressure will build in the tank.The Pressure Switch
senses this high pressure and at a certain high level, it turns
the compressor motor off.The level at which the motor
switches OFF is called the Cut-Out Pressure.
Duplex Receptacle - Two 120 volt AC receptacles that are
tied together. Similar to common household outlets.
GFCI - Ground fault current interrupter.A device that will
sense current flow in the milliamp range in a power circuit to
ground conductor and activate a relay to open both line
conductors.
Ground - A connection, either intentional or accidental,
between an electric circuit and the earth or some conducting
body serving in place of the earth.
Pressure Control – Often called a regulator, this device is
used to adjust the air compressor’s pressure output.The
Pressure Control is adjusted to supply the psi value required
by certain air tools, as monitored on the Outlet Pressure
Gauge.
psi - pounds per square inch.The measure of air pressure
delivered by the air compressor system.
Single Stage - Single stage refers to an air compressor with
one or more cylinders that take air in each cylinder at the
down stroke and compresses the air into the air tank on the
up stroke.
Tank Pressure Gauge A device used to indicate the air
pressure contained in the air tank, in psi
Two Stage - A two-stage compressor always has a minimum
of two cylinders - a low pressure (LP) cylinder (largest) and
an high pressure (HP) cylinder (smallest).As the LP piston
goes downward, air is taken in at atmospheric pressure; on
the upward stroke the LP piston discharges the air through
an intercooler and into the HP cylinder on its downward
stroke. On the upward stroke of the HP piston the air is
discharged into the air tank.Two-stage compressors are
recommended when tool usage is continuous.
Vibration Isolators When installed, are designed to
minimize vibrations produced by the air compressor.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC AIR COMPRESSOR OWNER WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the air compressor that is defective in
material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be
borne by purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find
the nearest Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied
warranty lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary
from state to state or country to country.
2 years
90 days
WARRANTY PERIOD
Consumer Use
Commercial Use
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other uses,
including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be
considered as commercial use for purposes of this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF
OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS
REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs.
Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty
service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or
improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the air compressor has been removed or
the equipment has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any
part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and
equipment:
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does
not cover repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage
so as, in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as air
filters, adjustments, and so forth.
Other Exclusions: This warranty excludes wear items such as seals and o-rings, etc.This warranty also excludes air compressors that
have been run without oil or subjected to freezing with water in the tank(s). This air compressor is warranted for non-continuous use and
should not be subjected to continuous operation. Accessory parts, such as hoses or air tools not supplied with the compressor are excluded
from the product warranty. This warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers
control.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WI, USA
Effective October 1, 2005 replaces all undated Warranties and all Warranties dated before October 1, 2005
198183E, Rev 1, 11/15/2005
DESCRIPTION / RÈGLES DE SÉCURITÉ
20
TABLE DES MATIÈRES
Règles de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22
Assemblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Fonctions et commandes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-28
Spécifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Entretien. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-32
Entreposage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Dépannage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-34
Glossaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Remarques. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Garantie. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Anglais . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
Espagnol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-56
DESCRIPTION DE L ÉQUIPEMENT
Ce manuel renferme des renseignements sur le fonctionnement et la
maintenance d’un compresseur d’air muni de deux réservoirs qui
produit 4,9 pi3/min à 40 lb/po2) (2,8 bars) et 3.6 pi3/min 90 lb/po2)
(6,2 bars) en utilisant un moteur électrique de 120 volts C.A. Ce
système résidentiel de haute qualité est doté d’une pompe à
entraînement direct lubrifiée à l’huile avec un manchon de fonte, une
soupape de démarrage facile, deux sorties d’air et une protection de
surcharge du moteur avec redémarrage manuel.
Tout a été fait pour s’assurer que les renseignements contenus dans
ce manuel soient exacts et à jour.Toutefois, nous nous réservons le
droit de changer, de modifier ou d’améliorer le produit et ce
document en tout temps, et ce, sans préavis.
Énoncé d’utilisation
Ce compresseur d’air a été fabriqué pour fournir un volume adéquat
d’air compressé pour assurer le fonctionnement d’une variété de
petits outils pneumatiques (rectifieurs à main ou clés à rochet) des
dispositifs de pulvérisation et de soufflerie requérant moins de
4,9 pi3/min de débit d’air pour fonctionner. Ne pas faire fonctionner
l’unité si la moyenne de température ne se situe pas entre 32° et
95° F (0° et 35° C). Ce compresseur est conçu pour fonctionner à
un maximum de 70 % de charge par heure à pleine capacité.
RÈGLES DE SÉCURITÉ
Ceci est la sûreté le symbole vif. Il est utilisé pour vous
alerter aux dangers de blessure personnels potentiels.
Obéir tous messages de sûreté qui suivent ce symbole
éviter la blessure ou la mort possibles.
Le symbole indiquant un message de sécurité
() est accompagné
d'un mot indicateur (DANGER,ATTENTION,AVERTISSEMENT),
d'un message illustré et/ou d'un message de sécurité visant à vous
avertir des dangers. DANGER indique un danger qui, s'il n'est pas
évité, provoquera des blessures graves, voire fatales.
AVERTISSEMENT indique un danger qui, s'il n'est pas évité, peut
provoquer des blessures graves, voire fatales. ATTENTION indique
un danger qui, s'il n'est pas évité, peut provoquer des blessures
mineures ou légères. Le mot ATTENTION, lorsqu'il est utilisé sans
le symbole d'alerte, indique une situation pouvant endommager
l'équipement. Suivez les messages de sécurité
() pour éviter ou
réduire les risques de blessures ou de mort.
Symboles de Danger et Moyens
VEUILLEZ CONSERVER CES INSTRUCTIONS
Feu
Auto-démarrage
Explosion
Air comprimé
InhalationSurface chaude
Choc electrique
Objets volants
Injection
pneumatique
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Briggs & Stratton 074000-0 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
Ce manuel convient également à