Invacare RPS350-1E Owner's Operating And Maintenance Manual

Taper
Owner's Operating And Maintenance Manual
STAND UP LIFT - MODEL RPS350-1E
STANDLIFT - MODELL RPS350-1E
STALIFT - MODEL RPS350 -1E
STAND UP LIFT - MODELE RPS350-1E
STAND UP LIFT - MODELO RPS350 - 1E
OWNER'S OPERATING and MAINTENANCE MANUAL
BETRIEBS- UND WARTUNGSANLEITUNG FÜR BENUTZER
BEDIENINGS- EN ONDERHOUDSHANDLEIDING
MANUEL DE L’UTILISATEUR FONCTIONNEMENT ET ENTRETIEN
MANUAL DE USO PARA EL PROPIETARIO
Y MANUAL DE MANTENIMIENTO
2
S
P
E
C
I
A
L
N
O
T
E
S
MAINTENANCE
Maintenance MUST be performed ONLY by qualified personnel.
SPECIAL NOTES
SPECIAL NOTES
SAVE THESE INSTRUCTIONS AND KEEP WITH STAND UP LIFT AT ALL TIMES.
WARNING notices as used in this manual apply to hazards or unsafe practices which
could result in serious bodily harm.
CAUTION notices as used in this manual apply to hazards or unsafe practices which
could result in minor personal injury or property damage.
NOTES highlight procedures and contain information which assist the operator in
understanding the information contained in this manual.
WARNING
DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND
UNDERSTANDING THE WARNINGS, CAUTIONS AND INSTRUCTIONS IN
THIS MANUAL AND THE OWNER’S MANUAL PROVIDED WITH THE SLINGS.
IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND
INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR
TECHNICAL PERSONNEL IF APPLICABLE BEFORE ATTEMPTING TO USE THIS
EQUIPMENT - OTHERWISE INJURY OR DAMAGE MAY RESULT.
RADIO FREQUENCY INTERFERENCE
Most electronic equipment is influenced by Radio Frequency Interference (RFI). CAU-
TION should be exercised with regard to the use of portable communication equip-
ment in the area around such equipment. If RFI causes erratic behavior, PUSH the Red
Emergency Stop Button IMMEDIATELY. DO NOT turn the Red Emergency Stop Button OFF
while transmission is in progress.
This product meets EN60601-1-2 Collateral Standard: Electromagnetic Compatibility.
"ATTENTION, see instructions for
use".
"Date of Manufacture"
SYMBOL LEGEND
WARNING - ALWAYS be aware of
the Lift Arms. Injury to the patient
and/or assistant may occur.
Device contains NiCd batteries. DO NOT dis-
pose of device or batteries in normal house-
hold waste. They MUST be taken to a proper
disposal site. Contact your local waste man-
agement company for information.
WARNING - ALWAYS be
aware of the Footrest,
especially the patient’s
position on the footrest.
Injury to the patient
and/or assistant may
occur.
3
SPECIAL NOTES ..................................................................................................................................2
SAFETY SUMMARY ..............................................................................................................................4
SPECIFICATIONS ..................................................................................................................................6
ASSEMBLY ............................................................................................................................................6
ATTACHING MAST TO BASE ...............................................................................................................6
ATTACHING ELECTRIC ACTUATOR TO MAST ...................................................................................6
OPERATION ..........................................................................................................................................7
OPERATING THE STAND UP LIFT ......................................................................................................7
Closing/Opening Legs of the Base......................................................................................................7
Locking/Unlocking the Rear Swivel Casters .......................................................................................7
Raising/Lowering Stand Up Lift ..........................................................................................................8
MOUNTING BATTERY CHARGER .......................................................................................................8
CHARGING BATTERIES ......................................................................................................................8
LIFTING PREPARATION ......................................................................................................................9
TRANSFERRING FROM .....................................................................................................................10
LIFTING THE PATIENT .......................................................................................................................10
MOVING THE PATIENT ...................................................................................................................... 11
TRANSFERRING TO ..........................................................................................................................12
TRANSFERRING THE PATIENT TO A WHEELCHAIR .......................................................................12
TRANSFERRING THE PATIENT TO A BED .......................................................................................13
TRANSFERRING THE PATIENT TO A COMMODE ............................................................................14
MAINTENANCE SAFETY INSPECTION CHECKLIST .......................................................................15
TROUBLESHOOTING ........................................................................................................................16
CARE AND MAINTENANCE OF YOUR STAND UP LIFT ...................................................................17
LUBRICATION ....................................................................................................................................17
WEAR AND DAMAGE ........................................................................................................................17
CLEANING .........................................................................................................................................17
ADJUSTING THE BASE .....................................................................................................................17
REPLACING THE KNEE PAD ............................................................................................................18
REPLACING OPTIONAL LEG STRAP ...............................................................................................18
REPLACING THE PADDED COVER .................................................................................................18
REPLACING ELECTRIC ACTUATOR ................................................................................................18
REPLACING CASTERS AND/OR FORKS .........................................................................................19
LIMITED WARRANTY ..........................................................................................................................20
BETRIEBS- UND WARTUNGSANLEITUNG FÜR BENUTZER ......................... 22
BEDIENINGS- EN ONDERHOUDSHANDLEIDING............................................ 42
MANUEL DE L’UTILISATEUR FONCTIONNEMENT ET ENTRETIEN ............... 62
MANUEL DE USO PARA EL PROPIETARIO Y MANUAL
DE MANTENIMIENTO ...................................................................................... 82
T
A
B
L
E
O
F
C
O
N
T
E
N
T
S
TABLE OF CONTENTS
TABLE OF CONTENTS
4
SAFETY SUMMARY
SAFETY SUMMARY
S
A
F
E
T
Y
S
U
M
M
A
R
Y
NOTE: Check all parts for shipping damage before using. In case of damage, DO NOT use the equipment.
Contact the Carrier/Dealer for further instructions.
WARNING
Invacare recommends that two (2) assistants be used for ALL lifting preparation, transferring from
and transferring to procedures.
DO NOT attempt any transfer without approval of the patient’s physician, nurse or medical assis-
tant. Thoroughly read the instructions in this Owner’s Manual, observe a trained team of experts
perform the lifting procedures and then perform the entire lift procedure several times with proper
supervision and a capable individual acting as a patient.
Individuals that use the Standing Sling (Model R130) MUST be able to support the majority of their
own weight, otherwise injury can occur.
DO NOT raise the patient to a full standing position while using the transport sling (Model
R134), otherwise injury can occur.
Invacare standing and transport slings are specifically designed to be used in conjunction with
the Invacare Stand Up Lift. Slings and accessories designed by other manufacturers or other
Invacare slings are not to be utilized as a component of Invacare’s stand up lift system. Use of
these products is prohibited and will void Invacare’s stand up lift warranty. Use only genuine
Invacare standing and transport slings and lift accessories to maintain patient safety and prod-
uct utility. Use the sling that is recommended by the individual’s doctor, nurse or medical assistant
for the comfort and safety of the individual being lifted.
Before positioning the legs of the stand up lift around the patient, make sure the patient's feet are
out of the way of the footplate, otherwise injury can occur.
The legs of the stand up lift MUST be in the MAXIMUM OPEN position and the shifter handle LOCKED
in place for optimum stability and safety. If the patient is in a transport sling and it becomes
necessary to move through a narrow passage, close the legs of the stand up lift ONLY AS LONG
AS IT TAKES TO MOVE THROUGH THE PASSAGE. Once the stand up lift is through the passage, return
the legs of the stand up lift to the MAXIMUM OPEN position and LOCK shifter handle IMMEDIATELY.
Invacare recommends locking the rear swivel casters ONLY when positioning or removing the
sling (standing or transport) from around the patient.
Invacare does NOT recommend locking the rear swivel casters of the stand up lift when lifting
and transferring an individual. Doing so could cause the lift to tip and endanger the patient and
assistants. Invacare DOES recommend that the rear swivel casters be left UNLOCKED during lifting
and transferring procedures to allow the stand up lift to stabilize itself when the patient is initially
lifted from and transferred to a chair, bed or any stationary object.
STANDING SLINGS - DO NOT use the standing sling in combination with the stand up lift as a
transport device. It is intended to transfer an individual from one resting surface to another (such
as a bed to a wheelchair). Moving a person using the standing sling in combination with the
stand up lift over ANY distance is NOT recommended.
STANDING SLINGS - Before lifting the patient, make sure the bottom edge of the standing sling is
positioned on the lower back of the patient and the patient's arms are outside the standing sling.
STANDING SLINGS - The belt MUST be snug, but comfortable on the patient, otherwise the patient
can slide out of the sling during transfer, possibly causing injury.
TRANSPORT SLINGS - Before lifting the patient, make sure the bottom edge of the transport sling is
at the base of the spine and the patient's arms are outside the transport sling.
5
SAFETY SUMMARY, (continued)
SAFETY SUMMARY
S
A
F
E
T
Y
S
U
M
M
A
R
Y
WARNING
DO NOT use any kind of material (such as a plastic back incontinence pad or seating cushion)
between the patient and sling material that may cause the patient to slide out of the sling during
transferring.
ALWAYS use the color coded strap on the standing sling closest to the patient while still maintain-
ing patient stability and comfort.
Bleached, torn, cut, frayed, or broken slings are unsafe and could result in injury. Discard Immedi-
ately.
DO NOT alter slings.
When elevated a few inches off the surface being transferred from and before moving the pa-
tient, check again to make sure that the sling is properly connected to the attachment points of
the stand up lift. If any attachments are NOT properly in place, lower the patient back onto the
surface and correct this problem.
During transfer, with patient suspended in a sling attached to the lift, DO NOT roll stand up lift over
objects such as carpet, raised carpet bindings, door frames, or any uneven surfaces or obstacles
that would create an imbalance of the stand up lift and could cause the stand up lift to tip over.
Use push handle on the mast at ALL times to push or pull the stand up lift.
Casters and axle bolts require inspection every six (6) months to check for tightness and wear.
After the first 12 months of operation, inspect all pivot points and fasteners for wear. If the metal is
worn, the parts MUST be replaced. Make this inspection every three (3) months thereafter.
The electric motor is sealed at the factory and if service is required, the motor unit MUST BE re-
turned to the factory for repair. DO NOT attempt to open the motor or obtain local service as this
will VOID the warranty and may result in damage and a costly repair. Consult your Dealer or
Invacare for further information.
Regular maintenance of Stand Up Lift and accessories is necessary to assure proper operation.
GROUNDING INSTRUCTIONS:
DO NOT, under any circumstances, cut or remove the round grounding prong from any plug used with
or for Invacare products. Some devices are equipped with three-prong (grounding) plugs for protec-
tion against possible shock hazards. Where a two-prong wall receptacle is encountered, it is the per-
sonal responsibility and obligation of the customer to contact a qualified electrician and have the
two-prong receptacle replaced with a properly grounded three-prong wall receptacle in accor-
dance with the National Electrical Code. If you must use an extension cord, use ONLY a three-wire
extension cord having the same or higher electrical rating as the device being connected. In addi-
tion, Invacare has placed RED/ORANGE WARNING TAGS on some equipment. DO NOT remove these
tags. Carefully read battery/battery charger information prior to operating, charging or servicing your
stand up lift.
WEIGHT LIMITATION
DO NOT exceed maximum weight limitation of the Stand Up Lift. The maximum weight limitation
is 350 lbs. (159 kg) regardless of any additional weight limitations on accessories.
6
Height at Sling Hook-
up Knob MAXIMUM:
Height at Sling Hook-
up Knob MINIMUM:
Base Width OPEN:
Base Width CLOSED:
Base Height
(Clearance):
Base Length:
Overall Height:
Overall Length:
Overall Width:
Caster Size FRONT:
Caster Size LOCKING
REAR:
Sling Options:
Sling Material:
Weight Capacity:
Weight:
Battery:
Charger Input:
Charger Output:
Charging Time:
Audio Low Battery
Alarm:
Motor Safety Devices:
* Approx. Lifts per
Charge:
Warranty (Electric/
Electronics):
Emergengcy Stop
Button:
168 cm
102 cm
94 cm
66 cm
12 cm
90 cm
124.5 cm
99 cm
65.5 cm
7.6 cm
12.7 cm
Standing or Transport (See
below for details)
Polyester
159 Kg
52.2 Kg
24 VDC (RECHARGEABLE)
100 - 240 VAC
29.5 VDC
Maximum 6 Hours
YES
Anti-Entrapment
*100-200 Cycles per
Charge
1 Year
YES
SPECIFICATIONS/ASSEMBLY
SPECIFICATIONS
S
P
E
C
I
F
I
C
A
T
I
O
N
S
Stand Up Lift
* Varies dependent upon load and stroke.
FIGURE 1 - ATTACHING MAST TO BASE
ATTACHING MAST TO BASE
(FIGURE 1)
1. Lock the rear swivel casters. Refer to LOCKING/
UNLOCKING THE REAR SWIVEL CASTERS in
this section of the manual.
2. Remove the hex bolt, nut and washer, that are lo-
cated in the U-shape cut-out of the base.
3. Position the mast in an upright position and place the
mast onto the U-shaped cut-out of the base.
4. Insert hex bolt with washers through the base and
mast. Secure with nut.
WARNING
The mast may be removed from the base
for storage or transporting. Each time mast
is removed and returned to base, the mast
MUST be properly secured to the base.
ATTACHING ELECTRIC ACTUATOR
TO MAST (FIGURE 2)
1. Remove the top nut, top bolt, bracket and bushing
from the lift arm mounting bracket.
2. Position the electric actuator in the lift arm mounting
bracket as shown in FIGURE 2.
3. Reinstall top nut, top bolt, bracket and bushing into lift
arm mounting bracket and electric actuator. Tighten se-
curely.
CAUTION
DO NOT overtighten mounting hardware.
This will damage mounting brackets.
Mast
U-Shaped
Cut-out
Hex Bolt
Nut
Washer
ASSEMBLY
A
S
S
E
M
B
L
Y
PATIENT SLINGS: STANDING TRANSPORT
Width 91.4 cm 97.8 cm
Length 33 cm 91.4 cm
7
OPERATION
OPENING
CLOSING
FIGURE 1- CLOSING/OPENING LEGS OF
BASE
OPERATING THE STAND UP LIFT
Closing/Opening Legs of Base (FIGURE 1)
The shifter handle is used to open or close the legs of the
base for stability when lifting a patient.
1. Stand at the rear of the stand up lift and grasp the
shifter handle with one (1) hand and place the oppo-
site hand on the push handle of the mast for balance.
NOTE: The shifter handle MUST lock into its mount-
ing slot to lock legs in the full open or closed position.
Legs of Base
Mounting Slot
Shifter Handle in Locked
CLOSED Position
Legs of
Base
Mounting
Slot
Shifter Handle in Locked
OPENED Position
O
P
E
R
A
T
I
O
N
OPERATION
FIGURE 2 - ATTACHING ELECTRIC ACTUATOR TO MAST
CLOSING.
1. Pull the shifter handle OUT and away from the
stand up lift and then to your LEFT until it LOCKS in
the notch of the bracket.
NOTE: Left is determined by standing behind the stand
up lift facing towards the front casters.
OPENING.
1. Pull the shifter handle OUT and away from the
stand up lift and then to your RIGHT until it LOCKS in
the notch of the bracket.
NOTE: Right is determined by standing behind the
stand up lift facing towards the front casters.
Locking/Unlocking the Rear Swivel
Casters (FIGURE 2)
1. Perform one (1) of the following:
A. LOCKING - Press DOWN on the BOTTOM of
the locking lever.
B. UNLOCKING - Press DOWN on the TOP of the
locking lever.
FIGURE 2 - LOCKING/UNLOCKING THE
REAR SWIVEL CASTERS
STEP HERE TO LOCK STEP HERE TO UNLOCK
Locking
Lever
Lift Arm
Mounting
Bracket
Electric
Actuator
Top Nut
Top
Bolt
Bushing
Bracket
8
O
P
E
R
A
T
I
O
N
OPERATION
FIGURE 3 - RAISING/LOWERING
STAND UP LIFT
Control
Box
Red Emergency Stop Button
MOUNTING BATTERY CHARGER
(FIGURE 4)
NOTE: Refer to your local regulations concerning proper
mounting procedures.
1. Place the battery charger with mounting bracket on
the wall at the desired position.
2. With a pencil, mark the MIDDLE hole position.
3. Measure down 16.5 cm from the pencil mark and drill
one (1) mounting hole.
FIGURE 4 - MOUNTING BATTERY CHARGER
Hand Control
UP Button
DOWN Button
Press IN to Stop
Lift Arms
Rotate CLOCKWISE to
Disengage Emergency Stop
BOTTOM
Mounting
Screw
(STEP 4)
Battery Charger with Mounting
Bracket (STEP 5)
Mounting
Screws
(STEP 7)
Mounting Bracket
(STEP 6)
CHARGING BATTERIES (FIGURE 5)
NOTE: Invacare recommends the battery be recharged
daily.
NOTE: An audible alarm will sound (horn will beep) when
battery is low.
1. Lift UP on the handle on the top of the battery.
2. Lift the battery UP and OUT away from control box.
WARNING
Make sure there is an audible click when
mounting battery on the battery charger
to confirm proper mounting. Otherwise,
injury or damage may occur. Refer to FIG-
URE 5 for correct mounting.
3. Place the battery on the battery charger as shown in
FIGURE 5. Make sure there is an audible click.
NOTE: The charge LED will illuminate.When charging is
complete, the charge LED will stop illuminating.
Raising/Lowering Stand Up Lift
(FIGURE 3)
RAISING THE LIFT. Press the UP (
ÏÏ
ÏÏ
Ï) button on the
hand control to raise the lift arms and the patient.
LOWERING THE LIFT. Press the DOWN (
ÐÐ
ÐÐ
Ð) button
on the hand control to lower the lift arms and the patient.
NOTE: If the Stand Up Lift is in the full UP position, it
may be necessary to pull down slightly on the lift arms
before the mast will lower.
EMERGENCY STOP. Press the RED button on the
control box IN to stop the lift arms and patient from raising
or lowering.
NOTE: Rotate RED emergency stop button CLOCK-
WISE until it pops out to disengage.
4. Install the BOTTOM mounting screw until there is an
approximate 3 mm gap between the screw head and
the wall.
5. Install the battery charger with mounting bracket
onto the bottom mounting screw.
6. Drill the remaining two (2) mounting holes.
7. Install the two (2) remaining mounting screws
through the mounting bracket and into the wall.
Tighten securely.
8. Plug battery charger into the wall electrical outlet.
NOTE: ON LED should illuminate.
9
FIGURE 5 - CHARGING BATTERIES
O
P
E
R
A
T
I
O
N
OPERATION
LIFTING PREPARATION
Refer to the patient sling Owner’s Manual, 1023891
for complete lifting preparation information.
Battery
Handle
(STEPS
1, 2, 4
and 5)
Battery
Charger
(STEP 3)
Audible Click
(STEPS 3
and 6)
Control Box
(STEP 6)
NOTE: A battery needing to be fully recharged will take
approximately six (6) hours.
4. Lift UP on the handle on the top of the battery.
5. Lift the battery UP and OUT away from battery charger.
WARNING
Make sure there is an audible click when
mounting battery on the control box to
confirm proper mounting. Otherwise, in-
jury or damage may occur. Refer to FIG-
URE 5 for correct mounting.
6. Reinstall the battery onto the control box as shown in
FIGURE 5. Make sure there is an audible click.
10
TRANSFERRING FROM
T
R
A
N
S
F
E
R
R
I
N
G
F
R
O
M
TRANSFERRING FROM
B. Patient's feet are positioned on the footplate as
shown in STEP 2B of FIGURE 1.
C. The bottom edge of the:
Standing Sling is positioned on the lower back.
Transport Sling is at the base of the patient's spine.
D. The patient's arms are outside of the standing or
transport sling.
E. The rear casters are unlocked.
F. Make sure the legs are in the maximum open posi-
tion and the shifter handle is locked in place.
WARNING
When elevated a few inches off the sur-
face being transferred from and before
moving the patient, check again to make
sure that the sling is properly connected
to the attachment points of the stand up
lift. If any attachments are NOT properly
in place, lower the patient back onto the
surface and correct this problem.
Adjustments for safety and comfort should
be made before moving the patient.
Invacare standing and transport slings are
specifically designed to be used in con-
junction with the Invacare Stand Up Lift.
Slings and accessories designed by other
manufacturers or other Invacare slings
are not to be utilized as a component of
Invacare’s stand up lift system. Use of
these products is prohibited and will void
Invacare’s stand up lift warranty. Use only
genuine Invacare standing and transport
slings and lift accessories to maintain pa-
tient safety and product utility.
If transferring from a wheelchair: Wheel-
chair wheel locks MUST be in the locked
position BEFORE lowering the patient into
the wheelchair.
3. Transferring from a wheelchair - Lock the wheel locks
of the wheelchair.
4. Press the UP (
Ï) button to raise the patient above
the surface (bed, wheelchair or commode) being
transferred from. The patient should be elevated just
high enough to clear the surface with their weight fully
supported by the lift.
NOTE: The lower center of gravity provides stability mak-
ing the patient feel more secure and the lift easier to move.
WARNING
Invacare recommends that two (2) assis-
tants be used for ALL lifting preparation,
transferring from and transferring to pro-
cedures.
LIFTING THE PATIENT (FIGURE 1)
1. Instruct the patient to do the following:
A. Hold onto the hand grips on both sides of the stand
up lift.
B. Lean back into the standing or transport sling.
WARNING
STANDING SLINGS - Before lifting the pa-
tient, make sure the bottom edge of the
standing sling is positioned on the lower
back of the patient and the patient's arms
are outside the standing sling.
TRANSPORT SLINGS - Before lifting the pa-
tient, make sure the bottom edge of the
transport sling is at the base of the spine
and the patient's arms are outside the
transport sling.
Invacare does NOT recommend locking
the rear casters of the stand up lift when
lifting and transferring an individual. Do-
ing so could cause the lift to tip and en-
danger the patient and assistants. Invac-
are DOES recommend that the rear cast-
ers be left UNLOCKED during lifting and
transferring procedures to allow the stand
up lift to stabilize itself when the patient is
initially lifted from and transferred to a
chair, bed or any stationary object.
The legs of the stand up lift MUST be in the
MAXIMUM OPEN position and the shifter
handle LOCKED in place for optimum sta-
bility and safety. If the patient is in a trans-
port sling and it becomes necessary to
move through a narrow passage, close
the legs of the stand up lift ONLY AS LONG
AS IT TAKES TO MOVE THROUGH THE PAS-
SAGE. Once the stand up lift is through
the passage, return the legs of the stand
up lift to the MAXIMUM OPEN position and
LOCK shifter handle IMMEDIATELY.
2. Make sure of the following:
A. Patient's knees are secure against the knee pad.
11
FIGURE 2 - MOVING THE PATIENT
MOVING THE PATIENT (FIGURE 2)
WARNING
STANDING SLINGS - DO NOT use the stand-
ing sling in combination with the stand up
lift as a transport device. It is intended to
transfer an individual from one resting sur-
face to another (such as a bed to a
wheelchair). Moving a person using the
standing sling in combination with the
stand up lift over ANY distance is NOT rec-
ommended.
During transfer, with patient suspended in
a sling attached to the lift, DO NOT roll
stand up lift over objects such as carpet,
raised carpet bindings, door frames, or
any uneven surfaces or obstacles that
would create an imbalance of the stand
up lift and could cause the stand up lift to
tip over. Use push handle on the mast at
ALL times to push or pull the stand up lift.
1. Using the push handle, move the stand up lift away
from the surface.
WARNING
The legs of the stand up lift MUST be in the
MAXIMUM OPEN position and the shifter
handle LOCKED in place for optimum sta-
bility and safety. If the patient is in a trans-
port sling and it becomes necessary to
move through a narrow passage, close
the legs of the stand up lift ONLY AS LONG
AS IT TAKES TO MOVE THROUGH THE PAS-
SAGE. Once the stand up lift is through
the passage, return the legs of the stand
up lift to the MAXIMUM OPEN position and
LOCK shifter handle IMMEDIATELY.
2. SLOWLY, move the patient to the desired surface.
3. Lower the patient onto the desired surface. Refer to
TRANSFERRING TO in this manual.
STEP 1
FIGURE 1 - LIFTING THE PATIENT
STEP 1A
STEP 1B
STEP 3
STEP 4
STEP
2A
STEP
2B
STEP
2C
STEP
2D
STEP
2E
NOTE: The lift arms will stay in position until the DOWN
(
ÐÐ
ÐÐ
Ð) button is pressed.
5. Move the patient to the desired surface. Refer to
MOVING THE PATIENT in this section of the
manual.
TRANSFERRING FROM
T
R
A
N
S
F
E
R
R
I
N
G
F
R
O
M
12
TRANSFERRING TO
T
R
A
N
S
F
E
R
R
I
N
G
T
O
TRANSFERRING TO
FIGURE 1 - TRANSFERRING THE PATIENT TO A
WHEELCHAIR
WARNING
Invacare recommends that two (2) as-
sistants be used for ALL lifting prepara-
tion, transferring from and transferring
to procedures.
TRANSFERRING THE PATIENT TO
A WHEELCHAIR (FIGURE 1)
1. Move the wheelchair into position.
WARNING
Wheelchair wheel locks MUST be in the
locked position BEFORE lowering the pa-
tient into the wheelchair.
2. Lock the rear wheels of the wheelchair.
3. Position the patient over the wheelchair.
4. Press the DOWN (
Ð) button and lower the pa-
tient into the wheelchair.
WARNING
Invacare recommends locking the rear
swivel casters ONLY when positioning or
removing the sling (standing or transport)
from around the patient.
5. Lock the rear swivel casters. Refer to LOCKING/
UNLOCKING THE REAR SWIVEL CASTERS in
the OPERATION section of this manual.
6. Unhook the standing or transport sling from all at-
tachment points on the stand up lift.
7. If equipped, unfasten the leg strap from around the
patient's legs.
8. Instruct the patient to lift their feet off of the footplate.
NOTE: Assist the patient if necessary.
9. Remove the standing or transport sling from
around the patient.
10. Pull the stand up lift away from the wheelchair.
STEP 2
STEP 1
STEP 4
STEP 6
13
FIGURE 2 - TRANSFERRING THE PATIENT TO
A BED
TRANSFERRING THE PATIENT TO
A BED (FIGURE 2)
NOTE: The lower center of gravity provides stability
making the patient feel more secure and the lift easier
to move.
NOTE: The lift arms will stay in position until the DOWN
(
ÐÐ
ÐÐ
Ð) button is pressed.
1. Position the patient as far over the bed as pos-
sible.
NOTE: If patient is being transferred from a surface
that is lower than the bed, press the UP (
ÏÏ
ÏÏ
Ï) button to
raise the patient above the surface of the bed. The
patient should be elevated just high enough to clear
the bed with their weight fully supported by the lift.
2. Press the DOWN (
Ð) button and lower the pa-
tient onto the bed.
WARNING
Invacare recommends locking the rear
swivel casters ONLY when positioning or
removing the sling (standing or transport)
from around the patient.
3. Lock the rear swivel casters. Refer to LOCKING/
UNLOCKING THE REAR SWIVEL CASTERS in
the OPERATION section of this manual.
4. Unhook the standing or transport sling from all at-
tachment points on the stand up lift.
5. If equipped, unfasten the leg strap from around the
patient's legs.
6. Instruct the patient to lift their feet off of the footplate.
NOTE: Assist the patient if necessary.
7. Remove the standing or transport sling from
around the patient.
8. Pull the stand up lift away from the bed.
STEPS 1 AND 2
STEP 4
TRANSFERRING TO
T
R
A
N
S
F
E
R
R
I
N
G
T
O
14
TRANSFERRING THE PATIENT TO
A COMMODE (FIGURE 3)
1. Position the patient over the commode.
2. Press the DOWN (
Ð) button and lower the patient
onto the commode.
WARNING
Invacare recommends locking the rear
swivel casters ONLY when positioning or
removing the sling (standing or transport)
from around the patient.
3. Lock the rear swivel casters. Refer to LOCKING/
UNLOCKING THE REAR SWIVEL CASTERS in
the OPERATION section of this manual.
4. Perform one (1) of the following:
A. Standing Sling (Model R130) -
Unhook the standing sling from the attach-
ment points on the stand up lift.
B. Transport Slings (Model R134) -
Unhook the transport sling from the bottom
attachment points on the stand up lift.
Lift up on the patient's legs and remove the
thigh supports from underneath the patient.
If desired, unhook the transport sling from the
top attachment points on the stand up lift.
NOTE: The patient can remain in the upper por-
tion of the transport sling while using the com-
mode.
5. If equipped, unfasten the leg strap from around the
patient's legs.
6. Instruct the patient to lift their feet off of the footplate.
NOTE: Assist the patient if necessary.
7. Remove the standing or transport sling from around
the patient.
8. Pull the stand up lift away from the commode.
9. Once the patient is ready to be transferred, refer to
the LIFTING PREPARATION section of this manual.
FIGURE 3 - TRANSFERRING THE PATIENT TO A
COMMODE
TRANSFERRING TO
T
R
A
N
S
F
E
R
R
I
N
G
T
O
STEP 1
STEP 3
STEPS 4 AND 5
15
THE CASTER BASE
z Inspect for missing hardware.
z Base opens/closes with ease.
z Inspect casters and axle bolts for tightness and wear.
z Inspect casters for smooth swivel and roll.
SHIFTER HANDLE
z Operates smoothly.
z Locks adjustable base whenever engaged.
THE MAST
z Mast MUST be securely assembled to lift arms.
z Inspect for bends or deflections.
THE LIFT ARMS AND LINKAGE
z Check all hardware and attachment points.
z Inspect for bends or deflections.
z Inspect bolted joints of lift arms for wear.
z Inspect to ensure that the lift arms are centered
between the base legs.
THE ELECTRIC ACTUATOR ASSEMBLY
z Check for wear or deterioration. (IF DAMAGED,
CONTACT DEALER).
z Cycle to ensure smooth quite operation.
CLEANING
z Whenever necessary.
SLINGS
z CHECK ALL SLING ATTACHMENTS each time it is
used to ensure proper connection and patient safety.
z Inspect sling material for wear.
z Inspect straps for wear.
MAINTENANCE SAFETY INSPECTION CHECKLIST
INITIALLYITEM INSPECT/ADJUST
MONTHLY
INSPECT/ADJUST
PERIODICALLY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
I
N
S
P
E
C
T
I
O
N
C
H
E
C
K
L
I
S
T
MAINTENANCE SAFETY INSPECTION CHECKLIST
16
SYMPTOMS
FAULTS
SOLUTION
Mast/Base joint loose.
Tie - Rods are loose.
Fluff or debris in bearings.
Needs lubrication.
Hand-control or actuator con-
nector loose.
RED emergency stop button
pressed IN.
Batteries low.
Battery not connected properly to
control box.
Electric actuator in need of ser-
vice.
Lift arms require a minimum
weight load to lower from the
uppermost position.
Stand up lift feels loose.
Casters/Brakes noisy or stiff.
Noisy or dry sound from pivots.
Electric actuator fails to lift when
button is pressed.
Lift arms will not lower in uppermost
position.
TROUBLESHOOTING
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
TROUBLESHOOTING
NOTE: If problems are not remedied by the suggested means, please contact your Dealer or Invacare.
Tighten the bolt, washer and locknut that
secure the mast to the base.
Refer to BASE ADJUSTMENT in the
CARE AND MAINTENANCE section of
this manual.
Refer to CASTERS in the CARE AND
MAINTENANCE section of this manual.
Refer to LUBRICATION in the CARE AND
MAINTENANCE section of this manual.
Check connections.
Rotate RED emergency stop button
CLOCKWISE until it pops out.
Charge batteries. Refer to CHARGING
BATTERIES in the OPERATION section
of this manual.
Reconnect the battery to the control box.
Refer to CHARGING BATTERIES in the
OPERATION section of this manual.
Refer to ELECTRIC ACTUATOR
REPLACEMENT in the CARE AND
MAINTENANCE section of this manual.
Contact your Dealer.
Pull down slightly on the lift arms.
17
CARE AND MAINTENANCE OF YOUR STAND UP LIFT
NOTE: Follow the maintenance procedures described in
this manual to keep your stand up lift in continuous ser-
vice.
The Invacare Stand Up Lift is designed to provide a
maximum of safe, efficient and satisfactory service with
minimum care and maintenance.
All parts of the Invacare Stand Up Lift are made of the best
grades of steel, but metal to metal contact will wear after
considerable use.
There is no adjustment or maintenance of either the cast-
ers or brakes, other than cleaning, lubrication and check-
ing axle and swivel bolts for tightness. Remove all debris,
etc. from the wheel and swivel bearings. If any parts are
worn, replace these parts immediately.
If you question the safety of any part of the lift, contact your
Dealer immediately and advise him/her of your problem.
LUBRICATION (FIGURE 1)
The Invacare Stand Up Lift is designed for minimum
maintenance; however, a six (6) month check should
ensure continued safety and reliability.
Keep lift and slings clean and in good working order. Any
defect should be noted and reported to your dealer as
soon as possible.
The casters MUST swivel and roll smoothly. A light grease
(waterproof auto lubricant) may be applied to the ball
bearing swivel of the casters once a year. Apply more
frequently if the casters are exposed to extreme moist
conditions.
WEAR AND DAMAGE
It is important to inspect all stressed parts, such as slings
and any attachment point for slings for signs of cracking,
fraying, deformation or deterioration. Replace any defective
parts immediately and ensure that the lift is not used until
repairs are made.
CLEANING
The sling should be washed regularly in water
temperature of 180
o
F (82
o
C) and a biological solution. A
soft cloth, dampened with water and a small amount of
mild detergent, is all that is needed to clean the stand up
lift. The lift can be cleaned with non-abrasive cleaners.
ADJUSTING THE BASE (FIGURE 2)
NOTE: The base adjustment should not require any
attention other than:
1. Check the squareness of the legs when in the
CLOSED position.
2. Place a square on the inside of the legs and base to
determine the 90
o
alignment.
3. Adjust the linkage rods until 90
o
alignment is achieved.
C
A
R
E
-
M
A
I
N
T
E
N
A
N
C
E
CARE AND MAINTENANCE OF YOUR STAND UP LIFT
FIGURE 1 - LUBRICATION
Lubricate the Bearings in the Caster Swivels
Square
Linkage
Rod
Linkage Rods
FIGURE 2 - ADJUSTING THE BASE
18
REPLACING THE KNEE PAD
(FIGURE 3)
1. Remove the four (4) button screws and washers that
secure existing knee pad to the stand up lift.
2. Remove the existing knee pad from stand up lift.
3. Position the mounting holes in the new knee pad with
the mounting holes in the stand up lift.
4. Using the existing hardware, secure the new knee
pad to the stand up lift.
5. Position the mounting holes in the knee pad with the
mounting holes in the stand up lift.
6. Using the existing hardware, secure the knee pad and
new leg strap to the stand up lift.
REPLACING THE PADDED COVER
(FIGURE 5)
1. Pull fastening strips on the existing padded cover apart.
2. Remove the existing padded cover from the lift arm.
3. Position the new padded cover around the lift arm.
4. Secure fastening strips on the new padded cover to-
gether.
REPLACING OPTIONAL LEG
STRAP (FIGURE 4)
1. Remove TOP (2) button screws and washers that
secure knee pad and existing leg strap to stand up lift.
2. Loosen BOTTOM two (2) button screws and wash-
ers that secure knee pad and existing leg strap to
stand up lift.
3. Remove the existing leg strap from stand up lift.
4. Position the new leg strap between the four (4) mount-
ing holes as shown in FIGURE 4.
NOTE: Make sure there is equal amounts of leg strap on
either side of the stand up lift.
C
A
R
E
-
M
A
I
N
T
E
N
A
N
C
E
CARE AND MAINTENANCE OF YOUR STAND UP LIFT
REPLACING ELECTRIC
ACTUATOR (FIGURE 6)
1. Remove the bottom nut, washer and shoulder bolt
that secure the electric actuator to the mast mounting
bracket.
2. Rest the lift arm on your shoulder and remove the top
nut, bolt, bracket and bushing from the lift arm mount-
ing bracket.
3. Remove the electric actuator.
4. Reverse STEPS 1-3 for installation of the new elec-
tric actuator.
CAUTION
DO NOT overtighten mounting hardware.
This will damage mounting brackets.
FIGURE 3 - REPLACING THE KNEE PAD
Knee Pad
Button Screws
Washers
Stand Up Lift
FIGURE 4 - REPLACING OPTIONAL LEG
STRAP
Leg Strap
Knee Pad
Button Screw
Washer
Stand Up
Lift
FIGURE 5 - REPLACING THE PADDED COVER
Padded Cover
Lift Arm
Fastening Strips
19
C
A
R
E
-
M
A
I
N
T
E
N
A
N
C
E
CARE AND MAINTENANCE OF YOUR STAND UP LIFT
REPLACING CASTERS AND/OR
FORKS (FIGURE 7)
WARNING
Casters and axle bolts require inspection
every six (6) months to check for tight-
ness and wear.
Rear Caster
1. Place the stand up lift on its side.
2. Remove the bolt and locknut that secure the existing
rear caster to the fork.
NOTE: The bushing will fall out of the rear caster.
NOTE: Existing bushing will be reused. Examine and re-
place if worn.
3. Install new/existing bushing into the new rear caster.
4. Line up the mounting holes in the new rear caster and
the fork.
5. Install the bolt through the fork and new rear caster
and tighten securely with the locknut.
Front Casters
1. Place the stand up lift on its side.
2. Remove the bolt and locknut that secure the existing
front caster assembly to the fork.
NOTE: The front caster assembly consists of two (2) cast-
ers and a washer in between.
NOTE: The washer will fall out from between the two (2)
casters.
NOTE: Existing washer will be reused. Examine and re-
place if worn.
3. Position new/existing washer between the two (2) new
casters.
4. Line up the mounting holes in the new front caster
assembly and the fork.
5. Install the bolt through the fork and new front caster
assembly and tighten securely with the locknut.
Forks
1. Place the stand up lift on its side.
2. Remove the front or rear caster from the stand up lift.
Refer to REPLACING CASTERS in this section of
the manual.
3. Unscrew the existing fork from the base.
4. Install the new fork onto the base.
5. Install the front or rear caster onto the stand up lift.
Refer to REPLACING CASTERS in this section of
the manual.
FIGURE 7 - REPLACING CASTERS AND/OR
FORKS
REAR
FRONT
Bolt
Bushing
Rear
Caster
Locknut
Fork
Base
Base
Front
Casters
Locknut
Fork
Bolt
Washer
Lift Arm Mounting Bracket
FIGURE 6 - REPLACING ELECTRIC ACTUATOR
Bottom Nut
Washer
Shoulder Bolt
Electric
Actuator
Top Nut
Top
Bolt
Bushing
Bracket
Mast Mounting Bracket
20
LIMITED WARRANTY
This warranty is extended only to the original purchaser of our products and does not affect
statutory rights.
Invacare UK / Invacare Service Representative warrants the products manufactured to be
free from defects in materials and workmanship for a period of three (3) years on the lift and one
(1) year on the slings and electric components from the date of purchase. If within such
warranty period the product shall be proven to Invacare UK’s / Invacare Service Representa-
tive reasonable satisfaction to be defective, it shall be repaired or replaced, at Invacare UK’s
/ Invacare Service Representative option; Invacare UK’s / Invacare Service Representative
sole obligation, and your exclusive remedy under this warranty being limited to such repair or
replacement.
For warranty service, please contact Invacare UK’s Service Department / Invacare Service
Representative during normal working hours. Upon receiving notice of an alleged defect in a
product, Invacare UK / Invacare Service Representative will issue a serialized return authoriza-
tion. The product shall then be returned to either Invacare plant or service center as specified
by Invacare UK / Invacare Service Representative. Defective component part(s) must be
returned for warranty inspection using the serial number as identification within thirty (30) days
of return authorization date. DO NOT return products to our factory without prior consent.
LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY DOES NOT COVER NORMAL WEAR
AND TEAR AND SHALL NOT APPLY TO PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT,
IMPROPER OPERATION, MAINTENANCE OR STORAGE, COMMERCIAL OR INSTITUTIONAL USE,
PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT (INCLUDING, BUT NOT
LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS)
OR TO PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT
THE SPECIFIC CONSENT OF INVACARE UK / INVACARE SERVICE REPRESENTATIVE.
LIMITED WARRANTY
L
I
M
I
T
E
D
W
A
R
R
A
N
T
Y
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Invacare RPS350-1E Owner's Operating And Maintenance Manual

Taper
Owner's Operating And Maintenance Manual

dans d''autres langues