Titan PowrTwin 4900, 6900, 8900, 12000 Plus Operation Manuel utilisateur

Catégorie
Systèmes de pulvérisation fine Power
Taper
Manuel utilisateur

Ce manuel convient également à

POWRTWIN
PLUS
Powered By Speeflo® HydraDrive
0223 • Form No. 0537853_I
AIRLESS, HIGH-PRESSURE
SPRAYING UNIT
AIRLESS HOCHDRUCK-
SPRITZGERÄT
GROUPE DE PROJECTION À
HAUTE PRESSION
- GB - OPERATION MANUAL 2
- D - BETRIEBSANLEITUNG 22
- F - MODE D’EMPLOI 44
OPERATION MANUAL
Models:
PT4900 (230V) 0290032
PT4900 (Gas) 0290012
PT6900 (Gas) 0290013
PT8900 (Gas) 0290018
PT12000 (Gas) 0290016 (Honda)
PT12000 (Gas) 0290016K (Kohler)
2 PowrTwin Plus
GB
Warning!
Attention: Danger of injury by injection!
Airless units develop extremely high spraying pressures.
Be safety conscious!
1
2
3
Never put your ngers, hands or any other parts of the body into
the spray jet!
Never point the spray gun at yourself, other persons or animals.
Never use the spray gun without safety guard.
Do not treat a spraying injury as a harmless cut. In case of injury
to the skin through coating materials or solvents, consult a doctor
immediately for quick and expert treatment. Inform the doctor
about the coating material or solvent used.
The operating instructions state that the following points must
always be observed before starting up:
1. Faulty units must not be used.
2. Secure Titan spray gun using the safety catch on the trigger.
3. Ensure that the unit is properly earthed.
4. Check allowable operating pressure of high-pressure hose and spray
gun.
5. Check all connections for leaks.
The instructions regarding regular cleaning and maintenance of
the unit must be strictly observed.
Before any work is done on the unit or for every break in work the
following rules must be observed:
1. Release the pressure from spray gun and hose.
2. Secure the Titan spray gun using the safety catch on the trigger.
3. Switch o unit.
Original Operating Manual
PowrTwin Plus 1
GB
Contents
Contents
Page
1. Safety regulations for Airless spraying ...................................... 2
1.1 Explanation of symbols used .............................................................. 2
1.2 Electrical safety ......................................................................................... 3
1.3 Gasoline engine safety .......................................................................... 4
1.4 Fueling (gas engine) ............................................................................... 4
1.5 Setting up on uneven surfaces ........................................................... 4
2. General view of application ............................................................. 5
2.1 Application ................................................................................................ 5
2.2 Coating materials .................................................................................... 5
3. Description of unit................................................................................ 5
3.1 Airless process .......................................................................................... 5
3.2 Functioning of the unit ......................................................................... 5
3.3 System diagram - gasoline PT units .................................................. 6
3.4 System diagram - electric PT units .................................................... 7
3.5 Technical data for PT units ................................................................... 8
3.6 Airless Spray Tip Recommendation Chart ...................................... 9
3.7 Instruction manuals list ......................................................................... 9
4. Operation ................................................................................................10
4.1 Setup ..........................................................................................................10
4.2 Preparing a new sprayer ..................................................................... 11
4.3 Preparing to paint ................................................................................. 12
4.4 Painting .....................................................................................................13
4.5 Pressure relief procedure ...................................................................13
5. Cleanup ....................................................................................................14
5.1 Special cleanup instructions for use with
ammable solvents ..............................................................................14
5.2 Cleaning the sprayer ............................................................................ 14
5.3 Cleaning a clogged tip ........................................................................14
6. Maintenance..........................................................................................15
6.1 Daily maintenance ................................................................................ 15
6.2 Maintaining the lter assembly........................................................15
6.3 Maintaining the hydraulic system ...................................................16
6.4 Maintaining the uid section ............................................................ 16
6.5 Basic engine maintenance ................................................................. 17
7. Troubleshooting .................................................................................18
7.1 Airless gun ...............................................................................................18
7.2 Fluid section ............................................................................................ 18
7.3 Hydraulic motors ................................................................................... 19
7.4 Spray patterns ........................................................................................20
Warranty ...............................................................................................................21
Accessories for PT units .................................................................................66
Gun manifold assemblies (optional) ..................................................... 68/69
2 PowrTwin Plus
GB
Safety precautions
1. Safety regulations for Airless spraying
1.1 Explanation of symbols used
This manual contains information that must be read and understood
before using the equipment. When you come to an area that has one
of the following symbols, pay particular attention and make certain
to heed the safeguard.
This symbol indicates a potential hazard that
may cause serious injury or loss of life. Important
safety information will follow.
At
tention
This symbol indicates a potential hazard to you
or to the equipment. Important information that
tells how to prevent damage to the equipment or
how to avoid causes of minor injuries will follow.
Danger of skin injection
Danger of fire from solvent and paint fumes
Danger of explosion from solvent, paint fumes
and incompatible materials
Danger of injury from inhalation of harmful
vapors
i
Notes give important information which should
be given special attention.
WARNING! CALIFORNIA PROPOSITION
65 WARNING
This product can expose you to chemicals including
lead, which are known to the State of California to
cause cancer, birth defects, or other reproductive
harm.
The engine exhaust from models with gas-powered
engines can expose you to carbon monoxide which is
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
For more information go to www.P65warnings.
ca.gov.
HAZARD: INJECTION INJURY
A high pressure stream produced by this equipment
can pierce the skin and underlying tissues, leading to
serious injury and possible amputation.
Do not treat a spraying injury as a harmless cut. In
case of injury to the skin through coating materials
or solvents, consult a doctor immediately for quick
and expert treatment. Inform the doctor about the
coating material or solvent used.
PREVENTION:
NEVER aim the gun at any part of the body.
NEVER allow any part of the body to touch the uid stream.
DO NOT allow body to touch a leak in the uid hose.
NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
ALWAYS lock the gun trigger, shut the uid pump o and
release all pressure before servicing, cleaning the tip guard,
changing tips, or leaving unattended. Pressure will not be
released by turning o the engine. The PRIME/SPRAY valve
or pressure bleed valve must be turned to their appropriate
positions to relieve system pressure.
ALWAYS keep tip guard in place while spraying. The tip guard
provides some protection but is mainly a warning device.
ALWAYS remove the spray tip before ushing or cleaning the
system.
NEVER use a spray gun without a working trigger lock and
trigger guard in place.
All accessories must be rated at or above the maximum
operating pressure range of the sprayer. This includes spray
tips, guns, extensions, and hose.
HAZARD
: HIGH PRESSURE HOSE
The paint hose can develop leaks from wear, kinking
and abuse. A leak can inject material into the skin.
Inspect the hose before each use.
PREVENTION:
Avoid sharp bending or kinking of the high-pressure hose. The
smallest bending radius amounts to about 20 cm.
Do not drive over the high-pressure hose. Protect against
sharp objects and edges.
Replace any damaged high-pressure hose immediately.
Never repair defective high-pressure hoses yourself!
Electrostatic charging of spray guns and the high-pressure
hose is discharged through the high-pressure hose. For this
reason the electric resistance between the connections of the
high-pressure hose must be equal to or lower than 1M.
For reasons of function, safety and durability use only original
Titan high-pressure hoses.
Before each use, check all hoses for cuts, leaks, abrasion
or bulging of cover. Check for damage or movement of
couplings. Immediately replace the hose if any of these
conditions exist. Never repair a paint hose. Replace it with
another earthed high-pressure hose.
Make sure power cord, air hose and spray hoses are routed in
such a manner to minimize slip, trip and fall hazard.
HAZARD: EXPLOSION OR FIRE
Flammable vapors, such as solvent and paint vapors,
in work area can ignite or explode.
PREVENTION:
Use equipment only in well ventilated area. Keep a good
supply of fresh air moving through the area to keep the air
within the spray area free from accumulation of ammable
vapors. Keep pump assembly in well ventilated area. Do not
spray pump assembly.
Electric models only - Do not use materials with a ashpoint
below 38º C (100º F). Flashpoint is the temperature at which a
uid can produce enough vapors to ignite.
Gas models only - Do not ll fuel tank while engine is running
or hot; shut o engine and allow to cool. Fuel is ammable
and can ignite or explode if spilled on a hot surface.
Eliminate all ignition sources, such as pilot lights, cigarettes,
portable electric lamps and plastic drop cloths (potential static
arc).
PowrTwin Plus 3
GB
Safety precautions
Keep work area free of debris, including solvent, rags and
gasoline.
Do not plug or unplug power cords, or turn power or light
switches on or o when ammable vapors are present.
Ground equipment and conductive objects in work area.
Make sure the grounding cable (not equipped) is connected
from the grounding lug to a true earth ground.
Use only grounded hoses.
Hold spray gun rmly to the side of a grounded pail when
triggering into pail.
If there is static sparking or if you feel a shock, stop operation
immediately.
Know the contents of the paint and solvents being sprayed.
Read all Material Safety Data Sheets (MSDS) and container
labels provided with the paints and solvents. Follow the paint
and solvent manufacturer’s safety instructions.
Do not use a paint or solvent containing halogenated
hydrocarbons. Such as chlorine, bleach, mildewcide,
methylene chloride and trichloroethane. They are not
compatible with aluminum. Contact the coating supplier
about compatibility of material with aluminum.
Keep a re extinguisher in work area.
HAZARD: HAZARDOUS VAPORS
Paints, solvents, and other materials can be harmful
if inhaled or come in contact with body. Vapors can
cause severe nausea, fainting, or poisoning.
PREVENTION:
Wear respiratory protection when spraying. Read all
instructions supplied with the mask to be sure it will provide
the necessary protection.
All local regulations regarding protection against hazardous
vapors must be observed.
Wear protective eyewear.
Protective clothing, gloves and possibly skin protection cream
are necessary for the protection of the skin. Observe the
regulations of the manufacturer concerning coating materials,
solvents and cleaning agents in preparation, processing and
cleaning units.
HAZARD: GENERAL
This product can cause severe injury or property
damage.
PREVENTION:
Follow all appropriate local, state, and national codes
governing ventilation, re prevention, and operation.
Pulling the trigger causes a recoil force to the hand that is
holding the spray gun. The recoil force of the spray gun is
particularly powerful when the tip has been removed and
a high pressure has been set on the airless pump. When
cleaning without a spray tip, set the pressure control knob to
the lowest pressure.
Use only manufacturer authorized parts. User assumes all
risks and liabilities when using parts that do not meet the
minimum specications and safety devices of the pump
manufacturer.
ALWAYS follow the material manufacturer’s instructions for
safe handling of paint and solvents.
Clean up all material and solvent spills immediately to prevent
slip hazard.
Wear ear protection. This unit can produce noise levels above
85 dB(A).
Never leave this equipment unattended. Keep away from
children or anyone not familiar with the operation of airless
equipment.
Do not spray on windy days.
The device and all related liquids (i.e. hydraulic oil) must be
disposed of in an environmentally friendly way.
1.2 Electric Safety
Electric models must be earthed. In the event of an electrical short
circuit, earthing reduces the risk of electric shock by providing an
escape wire for the electric current. This product is equipped with
a cord having an earthing wire with an appropriate earthing plug.
Connection to the mains only through a special feed point, e.g.
through an error protection insallation with INF < 30 mA.
DANGER — Work or repairs at the electrical
equipment may only be carried out by a skilled
electrician. No liability is assumed for incorrect
installation. Switch the unit o. Before all repair
work, unplug the power plug from the outlet.
Danger of short-circuits caused by water ingressing into the electrical
equipment. Never spray down the unit with high-pressure or high-
pressure steam cleaners.
Work or repairs at the electrical equipment:
These may only be carried out by a skilled electrician. No liability is
assumed for incorrect installation.
Operating Temperature
This equipment will operate correctly in its intended ambient, at a
minimum between +10°C and +40°C.
Relative Humidity
The equipment will operate correctly within an environment at 50%
RH, +40°C. Higher RH may be allowed at lower temperatures.
Measures shall be taken by the Purchaser to avoid the harmful eects
of occasional condensation.
Altitude
This equipment will operate correctly up to 2100 m above mean sea
level.
Transportation and Storage
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -25°C to +55°C and for
short periods up to +70°C.
It has been packaged to prevent damage from the eects of normal
humidity, vibration and shock.
1.3 Gasoline Engine Safety
1. Gas engines are designed to give safe and dependable service
if operated according to instructions. Read and understand
the engine manufacturer’s Owner’s Manual before operating
the engine. Failure to do so could result in personal injury or
equipment damage.
2. To prevent re hazards and to provide adequate ventilation,
keep the engine at least 1 meter (3 feet) away from buildings
and other equipment during operation. Do not place
ammable objects close to the engine.
3. People who are not operating the device must stay away from
the area of operation due to a possibility of burns from hot
engine components or injury from any equipment the engine
may be used to operate.
4. Know how to stop the engine quickly, and understand the
operation of all controls. Never permit anyone to operate the
engine without proper instructions.
5. Gasoline is extremely ammable and is explosive under
certain conditions.
6. Refuel in a well-ventilated area with the engine stopped. Do
not smoke or allow ames or sparks in the refueling area or
where gasoline is stored.
4 PowrTwin Plus
GB
Safety precautions
7. Do not overll the fuel tank. After refueling, make sure the
tank cap is closed properly and securely.
8. Be careful not to spill fuel when refueling. Fuel vapor or
spilled fuel may ignite. If any fuel is spilled, make sure the area
is dry before starting the engine.
9. Never run the engine in an enclosed or conned area. Exhaust
contains poisonous carbon monoxide gas; exposure may
cause loss of consciousness and may lead to death.
10. The muer becomes very hot during operation and remains
hot for a while after stopping the engine. Be careful not to
touch the muer while it is hot. To avoid severe burns or re
hazards, let the engine cool before transporting it or storing it
indoors.
11. Never ship/transport sprayer with gasoline in the tank.
DO NOT use this equipment to spray water or acid.
Attention
Do not lift by cart handle when loading or unloading.
Device is very heavy. Three-person lift is required.
1.4 Fueling (gas engine)
Gasoline is extremely flammable and is explosive
under certain conditions.
Attention
Do not overll the gas tank. Overlling can cause
the gas cap to become clogged with any particles
in the gasoline which can cause a vaccum. Read
the gas engine’s instruction manual for fueling
instructions.
Fuel Specications
Use automotive gasoline that has a pump octane number of
86 or higher, or that has a research octane number of 91 or
higher. Use of a lower octane gasoline can cause persistent
“pinging” or heavy “spark knock” (a metallic rapping noise)
which, if severe, can lead to engine damage.
iIf “spark knock” or “pinging” occurs at a steady
engine speed under normal load, change brands of
gasoline. If spark knock or pinging persists, consult
an authorized dealer of the engine manufacturer.
Failure to do so is considered misuse, and damage
caused by misuse is not covered by the engine
manufacturer’s limited warranty.
Occasionally you may experience light spark knock
while operating under heavy loads. This is no
cause for concern, it simply means your engine is
operating eciently.
Unleaded fuel produces fewer engine and spark plug deposits
and extends the life of the exhaust system components.
Never use stale or contaminated gasoline or an oil/gasoline
mixture. Avoid getting dirt, dust, or water in the fuel tank.
Gasolines Containing Alcohol
If you decide to use a gasoline containing alcohol (gasohol), be
sure its octane rating is at least as high as that recommended by
the engine manufacturer. There are two types of “gasohol”: one
containing ethanol, and the other containing methanol. Do not use
gasohol that contains more than 10% ethanol. Do not use gasoline
containing methanol (methyl or wood alcohol) that does not also
contain co-solvents and corrosion inhibitors for methanol. Never
use gasoline containing more than 5% methanol, even if it has co-
solvents and corrosion inhibitors.
iFuel system damage or engine performance
problems resulting from the use of fuels that contain
alcohol is not covered under the warranty. The
engine manufacturer cannot endorse the use of
fuels containing methanol since evidence of their
suitability is incomplete at this time.
Before buying gasoline from an unfamiliar station, try
to nd out if the gasoline contains alcohol. If it does,
conrm the type and percentage of alcohol used. If
you notice any undesirable operating characteristics
while using a gasoline that contains alcohol, or one
that you think contains alcohol, switch to a gasoline
that you know does not contain alcohol.
1.5 Setting up on uneven surfaces
The front side of the unit must point downwards to prevent sliding
away.
PowrTwin Plus 5
GB
General view of application Description of unit
2. General view of application
2.1 Application
Priming and nal coating of large areas, sealing, impregnation,
construction sanitation, façade protection and renovation, rust
protection and building protection, roof coating, roof sealing,
concrete sanitation, as well as heavy corrosion protection.
Examples of objects to be sprayed
Large-scale construction sites, cooling towers, bridges, sewage
treatment plants and terraces.
2.2 Coating materials
Processible coating materials
i
Pay attention to the Airless quality of the coating
materials to be processed.
Latex paint, dispersion paints, re protection and thick lm materials,
zinc dust and micaceous iron ore paints, Airless spray primer,
sprayable glue, anti-corrosive agents, thick coating materials and
bitumen-like coating materials.
No other materials should be used for spraying without Titan’s
approval.
Filtering
In spite of the high-pressure lter, ltering of the coating material is
to be recommended in general (except when processing airless joint
ller).
Stir coating material before commencement of work.
iMake sure when stirring with motor-driven agitators
that no air bubbles are stirred in. Air bubbles disturb
when spraying and can, in fact, lead to interruption
of operation.
Viscosity
It is possible to work with high-viscosity coating materials with the
devices.
If highly viscous coating materials cannot be sucked up, they must be
diluted in accordance with the manufacturer’s instruction.
Two-component coating material
The appropriate processing time must be adhered to exactly. Within
this time rinse through and clean the unit meticulously with the
appropriate cleaning agents.
Coating materials with sharp-edged additional materials
These have a strong wear and tear eect on valves, high-pressure
hose, spray gun and tip. The durability of these parts can be reduced
appreciably through this.
3. Description of unit
3.1 Airless process
The main area of application are thick layers of highly viscous coating
material for large areas and a high consumption of material.
A piston pump takes in the coating material by suction and conveys it
to the tip. Pressed through the tip at a pressure of up to a maximum
of 3300-3600 psi (228-248 bar, 24.4-24.8 MPa), the coating material is
atomised. This high pressure has the eect of micro ne atomisation
of the coating material.
As no air is used in this process, it is described as an AIRLESS process.
This method of spraying has the advantages of nest atomisation,
cloudless operation and a smooth, bubble-free surface. As well as
these, the advantages of the speed of work and convenience must be
mentioned.
3.2 Functioning of the unit
The following section contains a brief description of the technical
construction for better understanding of the function.
TITAN PowrTwin Plus (PT) are high-pressure spraying units driven by
either a gasoline engine or electric motor.
The gasoline engine or electric motor (g. 1, item 1) drives the
hydraulic pump (3) by means of a V-belt which is under the belt cover
(2). Hydraulic oil ows to the Speeo® HydraDrive™ hydraulic motor
(4) and then moves the piston up and down in the material feed
pump (5).
The inlet valve is opened automatically by the upwards movement
of the piston. The outlet valve is opened when the piston moves
downward.
The coating material ows under high pressure through the high-
pressure hose to the spray gun. When the coating material exits from
the tip it atomises.
The pressure control valve (6) controls the volume and the operating
pressure of the coating material.
2
4
56
3
1
6 PowrTwin Plus
GB
Description of unit
3.3 System diagram - gasoline PT units
1 Extractable handle
2 Speeo® HydraDrive™ hydraulic motor
3 Oil cup for separating oil (separating oil prevents increased
wear and tear of the packings)
4 Pressure control knob
5 Relief valve handle: Turn left for circulation k
Turn right for spray p
6 High-pressure lter
7 High-pressure hose outlet
8 V-belt under the belt cover
9 Bleed hose
10 Ball valve: horizontal position – hydraulic motor switched o
vertical position – hydraulic motor switched on
11 Suction tube
12 Oil measuring stick
13 Gasoline engine
1
7
8
5
4
6
2
3
9
10
11
12
13
10
3
PowrTwin Plus 7
GB
Description of unit
3.4 System diagram - electric PT units
1 Extractable handle
2 Speeo® HydraDrive™ hydraulic motor
3 Oil cup for separating oil (separating oil prevents increased
wear and tear of the packings)
4 Pressure control knob
5 Relief valve handle: Turn left for circulation k
Turn right for spray p
6 High-pressure lter
7 High-pressure hose outlet
8 V-belt under the belt cover
9 Bleed hose
10 Ball valve: horizontal position – hydraulic motor switched o
vertical position – hydraulic motor switched on
11 Suction tube
12 Oil measuring stick
13 Electric motor (230V)
14 ON/OFF switch
15 Control lamp that shows unit operational
16 Power Cord
8
9
10
11
13
12
14
15
16
1
7
5
4
6
2
3
10
3
8 PowrTwin Plus
GB
Description of unit
PT4900 Plus (230V) PT4900 Plus (gas) PT6900 Plus PT8900 Plus PT12000 Plus
Gasoline engine, power
Honda -------- 163cc, 4.8 Hp 163cc, 4.8 Hp 196cc, 5.5 Hp 270cc, 8.5 Hp
Kohler -------- -------- -------- -------- 277cc, 9.5 Hp
Fuel Capacity
-------- 0.83 US gal (3.1 l) 0.83 US gal (3.1 l) 0.83 US gal (3.1 l) 1.6 US gal (6.06 l)
Voltage
230 V~, 50 Hz -------- -------- -------- --------
Capacity
2.6 kW -------- -------- -------- --------
Power Cord
3 x 2.5 mm – 6 m -------- -------- -------- --------
Fuse Protection
16 A -------- -------- -------- --------
Max. operating pressure
22.8 MPa (228 bar, 3300 psi) 24.8 MPa (248 bar,
3600 psi)
Max. sound pressure level
80 dB (A)* 92 dB (A)* 98 dB (A)*
Max. size of tip with a spray gun
1-gun 0.038” – 0.97 mm 0.044” – 1.12 mm 0.050” – 1.27 mm 0.054” – 1.37 mm 0.058” – 1.47 mm
2-gun 0.027” – 0.69 mm 0.031” – 0.79 mm 0.035” – 0.89 mm 0.038” – 0.96 mm 0.040” – 1.01 mm
3-gun 0.021” – 0.53 mm 0.025” – 0.64 mm 0.029” – 0.74 mm 0.032” – 0.81 mm 0.034” – 0.86 mm
4-gun -------- -------- 0.025” – 0.64 mm 0.028” – 0.71 mm 0.030” – 0.76 mm
5-gun -------- -------- -------- 0.024” – 0.61 mm 0.026” – 0.66 mm
6-gun -------- -------- -------- -------- 0.024” – 0.61 mm
Max. volume ow
1.1 gal (4.2 l)/min 1.5 gal (5.7 l)/min 2.25 gal (8.5 l)/min 2.5 gal (9.5 l)/min 3.15 gal (11.9 l)/min
Weight
139 lbs. (63 kg) 132 lbs. (60 kg) 139 lbs. (63 kg) 154 lbs. (70 kg) 183 lbs. (83 kg)
Max. viscosity
50.000 mPa·s 65.000 mPa·s
Dimensions L x W x H
37.2” x 26.8” x 35” (946 x 680 x 890 mm)
42.5” x 27” x 31” (1080 x
686 x 866 mm)
46” x 27” x 31” (1168 x
686 x 866 mm)
Max. temperature of the coating material
109ºF (43° C)
Filter insert (standard equipment)
50 mesh, 18 in25 mesh, 18 in2
Hydraulic oil lling quantity
5.9 l (1.56 gal) CoolFlo
Max. tire pressure
0.2 MPa (2 bar)
Special high-pressure hose
DN 6 mm, 15 m (50’ x 1/4”), connection thread NPSM 1/4
* Place of measurement: 1 m distance from unit and 1.60 m above reverberant oor, 120 bar (12 MPa) operating pressure.
3.5 Technical data for PT units
PowrTwin Plus 9
GB
Description of unit
3.6 Airless Spray Tip Recommendation Chart
Viscosity Filter Mesh Coating Orice Range Synergy™ (Fine Finish)
Light 100-150 Varnishes .009 - .011 .008 - .010
Lacquer Finishes (clear) .009 - .011 .008 - .010
Sanding Sealers .009 - .011 .008 - .010
Shellac (clear) .009 - .013 .008 - .012
Transparent Stain .011 - .013 .010 - .012
Water Sealers (clear) .011 - .013 .010 - .012
Medium 60-100 Solid Stains .013 - .015
Exterior House Paints .013 - .017
Interior Wall Paints .013 - .017
Interior & Exterior Primers .017 - .019
Heavy 30-60 Commercial Grade
Architectural Coatings .017 - .019
Interior Wall Paints .017 - .019
Interior Wall Primers .017 - .019
Dry Fall (quick dry) .019 - .023
One Coat, Primer-Finish Paints .019 - .023
Extra Heavy 0 Elastomerics .021 - .031
Pigmented Waterproofers .021 - .027
Block Filler .025 - .031
Orice sizes recommended on this chart are based on fan widths between 8 inches (20 cm) and 12 inches (30 cm)
3.7 Instruction manuals list
The following is a list of the available instruction manuals for this unit.
Online items can be downloaded at www.titantool.com
Description Form # How to Find
Operation Manuals
GB/D/F 537853 • included with unit
• online
E/I/P 537854
NL/DK/S 537855
RFB 537867
Service Manual, Spare Parts
GB/D/F 2439109 • online
E/I/P 2439114
NL/DK/S 2439115
RFB 2439116
10 PowrTwin Plus
GB
Operation
4. Operation
This equipment produces a fluid stream at extremely
high pressure. Read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
4.1 Setup
1. Make sure the siphon hose (g. 4, 1) is connected to the uid
section (2) and the bleed hose (3) is connected to the bleed
valve (4). They each have factory installed PTFE tape on the
male end of the hoses and should be wrench tight.
3
1
4
2
2. Attach a minimum of 15m of nylon airless spray hose to the
sprayer. Do not use PTFE tape or thread sealant on the spray
hose connection.
3. Attach an airless spray gun to the spray hose. Do not attach
the tip to the spray gun yet. Remove the tip if it is already
attached.
a. To use two guns, remove the plug from the second gun outlet
on the lter assembly. Connect a hose and gun to the outlet.
iFor multiple gun operation, connect a multiple gun
manifold to the single gun outlet. Connect a hose
and gun to each outlet. Make sure the second gun
outlet remains plugged. See “Technical Data”,
Section 3.5 to determine number of guns and
maximum spray tip sizes.
4. Fill the oil cup 1/2 full with Piston Lube (P/N 314-480). This
extends packing life.
Attention
Piston Lube prevents increased wear and tear to the
packings.
5. Check the hydraulic uid level daily before starting the
sprayer. The hydraulic uid level should be at the “Full” mark
on the dipstick. Refer to the Maintenance section of this
manual for hydraulic system maintenance instructions.
Attention
Use of Titan’s Coolflo™ Hydraulic Fluid (P/N 430-361)
is mandatory in the hydraulic system. Do not use
any other hydraulic fluid. Use of any other hydraulic
fluid may seriously damage the hydraulic system
and will void the warranty.
6. For gas models, check the engine oil level daily before starting
the sprayer. The gasoline engine oil level is determined by
the engine manufacturer. Refer to the engine manufacturer’s
service manual supplied with this sprayer.
7. For electric models, use a 20 amp service outlet. Always
locate the electric model within 10 to 15 feet of the service
outlet. Use a short electric cable and a long paint hose. Any
extension cord will create some voltage drop. If an extension
cord is necessary, use only a grounded 3-wire #12 extension
cord.
8. Make sure the sprayer is earthed. All sprayers are equipped
with a earthing lug. An earthing cable (not supplied) should
be used to connect the sprayer to a true earth ground.
Check your local electrical regulations for detailed earthing
instructions.
Proper earthing is important. This applies to both
gas and electric powered models. The passage of
some materials through the nylon uid hose will
build up a static electric charge, which if discharged,
could ignite solvent vapors present and create an
explosion.
9. Strain all paints with a nylon strainer to ensure trouble free
operation and freedom from frequent cleaning of the inlet
screen and gun lter.
10. Make sure the spray area is well ventilated to prevent
hazardous operation with volatile solvents or exhaust fumes.
If lacquer or other flammable materials are to be
sprayed, ALWAYS locate the sprayer outside the
immediate spraying area. Failure to do so may cause
an explosion.
11. Locate the sprayer outside the immediate spraying area to
avoid clogged air intake of the engine or electric motor with
overspray.
PowrTwin Plus 11
GB
Operation
4.2 Preparing a New Sprayer
If this unit is new, it is shipped with test uid in the uid section to
prevent corrosion during shipment and storage. This uid must be
thoroughly cleaned out of the system with mineral spirits before you
begin spraying.
Attention
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the bleed hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to its
lowest pressure setting (g 7, 1).
4. Open the hydraulic shut-o valve (2) located on the hydraulic
pressure hose. The handle should be in line with the hose.
5. Open the bleed valve (3) by turning it fully counterclockwise.
1
3
2
6. Start the engine or turn on the electric motor.
a. To start the gas engine (g. 8),
move the fuel valve lever (2) to the open position,
move the throttle lever (3) to its middle point,
move the choke lever (4) to the closed position for a cold
engine or to the open position for a warm engine,
turn the engine switch (1) to the ON position, and
pull the starter rope (5) briskly until the engine starts.
b. To start the electric motor, move the ON/OFF switch to the ON
position.
2
4
1
3
5
7. Turn the pressure control knob (g. 7, 1) clockwise
approximately 1/3 of the way down to increase pressure until
the sprayer cycles evenly and solvent ows freely from the
bleed hose.
8. Allow the sprayer to run for 15–30 seconds to ush the test
uid out through the bleed hose and into the waste container.
9. Turn o the sprayer.
a. To turn o the gas engine,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the throttle lever to the slow position, and
turn the engine switch to the OFF position.
b. To turn o the electric motor,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
Earth the gun by holding it against the edge of the
metal container while flushing. Failure to do so may
lead to a static electric discharge, which may cause
a fire.
14. Trigger the gun into the metal waste container until the old
solvent is gone and fresh solvent is coming out of the gun.
15. Lock the gun by turning the gun trigger lock to the locked
position (g 10).
16. Set down the gun and increase the pressure by turning the
pressure control knob slowly clockwise to its highest setting.
17. Check the entire system for leaks. If leaks occur, turn the
sprayer o and follow the “Pressure Relief Procedure” in this
manual before tightening any ttings or hoses.
18. Follow the “Pressure Relief Procedure” (section 4.5) in this
manual before changing from solvent to paint.
Be sure to follow the Pressure Relief Procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
4.3 Preparing to Paint
Before painting, it is important to make sure that the uid in the
system is compatible with the paint that is going to be used.
iIncompatible uids and paint may cause the valves
to become stuck closed, which would require
disassembly and cleaning of the sprayer’s uid
section.
Attention
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
solvent for the material being sprayed.
iIf you are spraying a water-based latex, ush with
warm, clean water. If you are using any other
material, check with the material manufacturer for a
compatible solvent.
2. Place the bleed hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to its
lowest pressure setting (g 7, 1).
4. Open the hydraulic shut-o valve (2) located on the hydraulic
pressure hose. The handle should be in line with the hose.
5. Open the bleed valve (3) by turning it fully counterclockwise.
6. Start the engine or turn on the electric motor.
a. To start the gas engine (g. 8),
move the fuel valve lever (2) to the open position,
move the throttle lever (3) to its middle point,
move the choke lever (4) to the closed position for a cold
engine or to the open position for a warm engine,
turn the engine switch (1) to the ON position, and
pull the starter rope (5) briskly until the engine starts.
b. To start the electric motor, move the ON/OFF switch to the ON
position.
7. Turn the pressure control knob (1) clockwise approximately
1/3 of the way down to increase pressure until the sprayer
cycles evenly and solvent ows freely from the bleed hose.
8. Allow the sprayer to run for 15–30 seconds to ush the test
uid out through the bleed hose and into the waste container.
9. Turn o the sprayer.
a. To turn o the gas engine,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the throttle lever to the slow position, and
turn the engine switch to the OFF position.
b. To turn o the electric motor,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
i
Make sure that the spray gun does not have a tip or
tip guard installed.
10. Close the bleed valve by turning it fully clockwise.
11. Start the engine or turn on the electric motor.
12. Turn the pressure control knob clockwise approximately 1/3
of the way down to increase pressure.
13. Unlock the gun by turning the gun trigger lock to the
unlocked position.
12 PowrTwin Plus
GB
Operation
4.4 Painting
1. Place the siphon hose into a container of paint.
2. Place the bleed hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to its
lowest pressure setting (g 7, 1).
4. Open the hydraulic shut-o valve (2) located on the hydraulic
pressure hose. The handle should be in line with the hose.
5. Open the bleed valve (3) by turning it fully counterclockwise.
6. Start the engine or turn on the electric motor.
a. To start the gas engine (g. 8),
move the fuel valve lever (2) to the open position,
move the throttle lever (3) to its middle point,
move the choke lever (4) to the closed position for a cold
engine or to the open position for a warm engine,
turn the engine switch (1) to the ON position, and
pull the starter rope (5) briskly until the engine starts.
b. To start the electric motor, move the ON/OFF switch to the ON
position.
7. Turn the pressure control knob (1) clockwise approximately
1/3 of the way down to increase pressure until the sprayer
cycles evenly and solvent ows freely from the bleed hose.
8. Turn o the sprayer.
a. To turn o the gas engine,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the throttle lever to the slow position, and
turn the engine switch to the OFF position.
b. To turn o the electric motor,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
9. Remove the bleed hose from the waste container and place it
into the container of paint.
10. Close the bleed valve by turning it fully clockwise.
11. Start the engine or turn on the electric motor.
12. Turn the pressure control knob clockwise approximately 1/3
of the way down to increase pressure.
13. Unlock the gun by turning the gun trigger lock to the
unlocked position.
Earth the gun by holding it against the edge of the
metal container while flushing. Failure to do so may
lead to a static electric discharge, which may cause
a fire.
14. Trigger the gun into the metal waste container until all air and
solvent is ushed from the spray hose and paint is owing
freely from the gun.
15. Lock the gun by turning the gun trigger lock to the locked
position (g 10).
16. Turn o the sprayer.
17. Attach tip guard and tip to the gun as instructed by the tip
guard or tip manuals.
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the unclog
position. Always engage the gun trigger lock before
removing, replacing or cleaning tip.
18. Start the engine or turn on the electric motor.
PowrTwin Plus 13
GB
Operation
19. Increase the pressure by turning the pressure control knob
slowly clockwise and test the spray pattern on a piece of
cardboard. Adjust the pressure control knob until the spray
from the gun is completely atomized.
iTurning the pressure up higher than needed to
atomize the paint will cause premature tip wear and
additional overspray.
4.5 Pressure Relief Procedure
Be sure to follow the Pressure Relief Procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray nozzles, or preparing for
cleanup.
1. Lock the spray gun by turning the gun trigger lock to the
locked position.
2. Turn o the sprayer.
a. To turn o the gas engine,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the throttle lever to the slow position, and
turn the engine switch to the OFF position.
b. To turn o the electric motor,
set the pressure to minimum by turning the pressure control
knob fully counterclockwise,
move the ON/OFF switch to the OFF position.
3. Close the hydraulic shut-o valve on the hydraulic pressure
hose.
4. Unlock the gun by turning the gun trigger lock to the
unlocked position.
5. Hold the metal part of the gun rmly to the side of a metal
waste container to earth the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any pressure that may still be in the
hose.
7. Lock the gun by turning the gun trigger lock to the locked
position.
8. Place the bleed hose into the metal waste container.
9. Open the bleed valve by turning it fully counterclockwise.
14 PowrTwin Plus
GB
Cleanup
5. Cleanup
Attention
The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits
material to build up, seriously aecting the
performance of the unit.
Always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a re or
explosion in the presence of ammable vapors.
5.1 Special cleanup instructions for use with
ammable solvents
Always ush spray gun preferably outside and at least one hose
length from spray pump.
If collecting ushed solvents in a one gallon metal container,
place it into an empty ve gallon container, then ush solvents.
Area must be free of ammable vapors.
Follow all cleanup instructions.
5.2 Cleaning the sprayer
1. Follow the “Pressure Relief Procedure” found in the Operation
section of this manual, section 4.5.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent.
Attention
Use only compatible solvents when cleaning
out oil based enamels, lacquers, coal tar, and
epoxies. Check with the uid manufacturer for the
recommended solvent.
4. Place the bleed hose into a metal waste container.
5. Set the pressure to minimum by turning the pressure control
knob (1) fully counterclockwise.
6. Open the hydraulic shut-o valve located on the hydraulic
pressure hose (2). The handle should be in line with the hose.
7. Open the bleed valve (3) by rotating the bleed valve handle
fully counterclockwise.
1
3
2
8. Start the engine or turn on the electric motor.
9. Allow the solvent to circulate through the sprayer and
ush the paint out of the bleed hose into the metal waste
container.
10. Turn o the sprayer.
11. Close the bleed valve by rotating the bleed valve handle fully
clockwise.
12. Start the engine or turn on the electric motor.
Earth the gun by holding it against the edge of the
metal container while flushing. Failure to do so may
lead to a static electric discharge, which may cause
a fire.
13. Trigger the gun into the metal waste container until the paint
is ushed out of the hose and solvent is coming out of the
gun.
14. Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
iFor long-term, cold weather storage, or any freezing
temperature exposure pump mineral spirits through
the entire system.
For short-term storage not exposed to freezing
temperatures when using latex paint, pump water
mixed with Titan Liquid Shield through the entire
system (see Accessories section of this manual
for part number and product label for dilution
instructions).
15. Follow the “Pressure Relief Procedure” found in the Operation
section of this manual.
16. Store the sprayer in a clean, dry area.
Attention
Do not store the sprayer under pressure.
5.3 Cleaning a Clogged Tip
1. Follow the “Pressure Relief Procedure” in the Operation
section of this manual.
2. If the tip clogs, rotate the tip handle 180° until the arrow on
the handle is facing the opposite of the spray direction and
the handle clicks in the reverse position.
3. Trigger the gun once so that the pressure can blow the clog
out. NEVER use the tip in the reverse position for more than
ONE trigger pull at a time. This procedure can be repeated
until the tip is free of clogging.
The flow from the spray tip is at very high pressure.
Contact with any body part may be dangerous. Do
not place finger on gun outlet. Do not point the gun
at any person. Never operate the spray gun without
the proper tip guard.
PowrTwin Plus 15
GB
Maintenance
6. Maintenance
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
6.1 Daily Maintenance
Two daily procedures are required for routine operator maintenance
on this sprayer:
A. Lubricating the upper packings.
B. Cleaning the lter screen
A) Lubricating the Upper Packings
1. Clean out the paint that has seeped past the upper packings
into the packing oil reservoir (g. 13, item 1) above the uid
section.
2. Fill the packing oil reservoir 1/2 full with Piston Lube (P/N 314-
480) supplied by the factory. This will extend packing life.
1
i
Do not over-ll the reservoir so that it overows and
drips into the paint.
B) Cleaning the Filter Screen
1. The lter screen will clog and must be cleaned at least once a
day.
2. Loosen the hex nut (g. 14, item 1) that secures the lter
screen to the siphon tube.
3. Remove the lter screen (2) from the bottom of the siphon
tube.
4. Clean thoroughly with the appropriate solvent.
2
1
6.2 Maintaining the Filter Assembly
Clean the lter regularly. Dirty or clogged lters can greatly reduce
ltering ability and cause a number of system problems including
poor spray patterns, clogged spray tips, etc.
Cleaning (Fig. 15)
To clean the lter, perform the following procedure.
1. Follow the “Pressure Relief Procedure” found in the Operation
section of this manual.
2. Remove the lter cap assembly (1) and spring (2).
3. Pull the lter element with ball straight (3) out of the lter
body (4).
4. Clean inside the lter body, lter element with ball, and lter
cap assembly using the appropriate solvent.
iUse care in handling parts as dirt, debris, scratches,
or nicks may prevent o-rings or gaskets from sealing.
This lter element lters from the inside out. Be sure
to clean the lter element thoroughly on the inside.
Soak in solvent to loosen hardened paint or replace.
1
3
7
8
5
6
4
2
Inspection (Fig. 15)
Inspect all parts of the lter assembly before reassembly.
1. Inspect the ball inside the lter element. If the ball has
pressure cuts or scratches, replace the lter element.
a. If the ball is cut, remove the PTFE o-ring (5) using an o-ring pick
and remove the carbide seat (6).
b. Check the seat for nicks or grooves. If the seat is damaged,
replace.
i
Removal of the PTFE o-ring will damage the o-ring
and require replacement.
2. Remove the spring (2) from the spring guide on the lter cap.
a. Measure the length of the spring uncompressed. If it measures
less than 3/4” from end to end, replace.
b. Push the spring back onto the spring guide until it “snaps” back
into position.
3. Inspect the two PTFE gaskets (7,8) and the PTFE o-ring (5) for
deformity, nicks, or cuts. Replace, if needed.
i
The PTFE gaskets, PTFE o-ring, and spring are
packaged in Filter Service Kit P/N 930-050.
16 PowrTwin Plus
GB
Maintenance
Reassembly (Fig. 15)
After cleaning and inspecting all parts, reassemble the lter.
1. Place the carbide seat (6) into the lter body (4). Make sure
the beveled side of the seat is facing up.
2. Place the PTFE o-ring (5) into the groove on the outer
diameter of the carbide seat (6).
3. Place the lter element with ball (3) into the lter body (4).
i
The top and bottom of the lter element with ball
are identical.
4. Push the spring (2) back onto the spring guide of the lter cap
(1) until it “snaps” back into position, if not already done.
5. Place the thin PTFE gasket (8) onto the step at the top of the
lter body (4).
6. Place the thick PTFE gasket (7) onto the top of the thin gasket
(8).
7. Tighten the lter cap assembly (1) onto the lter body (4).
1
3
7
8
5
6
4
2
6.3 Maintaining the Hydraulic System
Attention
Use of Titan’s Coolflo™ Hydraulic Fluid is mandatory
in the PowrTwin Plus hydraulic system. Do not use
any other hydraulic fluid. Use of any other hydraulic
fluid may seriously damage the hydraulic system
and will void the warranty.
1. Check the hydraulic uid daily. It should be at the “Full”
mark (g. 16, item 1) on the dipstick (2). If it is low, add only
Titan Coolo™ Hydraulic Fluid (P/N 430-361). Never add
or change hydraulic uid except in a clean, dust-free area.
Contamination of the hydraulic uid will shorten hydraulic
pump life and may void warranty.
1
2
3
2. Change the hydraulic uid every twelve months. Drain the
old uid from the tank and ll with 6.25 quarts of hydraulic
uid. Start the sprayer at just enough pressure to operate the
uid section. Run the sprayer at this low pressure for at least
5 minutes. This removes air from the system. Check the uid
level after this procedure. Do not over-ll.
iWhen replacing the hydraulic filter (3) during a
fluid change, it may be necessary to add up to one
additional quart of hydraulic fluid.
3. The hydraulic system has an external, replaceable hydraulic
lter. Change the lter every twelve months.
4. The hydraulic pump should not be serviced in the eld. If
service on the hydraulic pump is required, it must be returned
to Titan.
6.4 Maintaining the Fluid Section
If the sprayer is going to be out of service for an extended period of
time, it is recommended that following cleanup, a kerosene and oil
mixture be introduced as a preservative. Packings may tend to dry
out from lack of use. This is particularly true of the upper packing
set for which upper packing lubricant Piston Lube (P/N 314-480) is
recommended in normal usage.
If the sprayer has been out of service for an extended period of time,
it may be necessary to prime the pump with solvent. It is extremely
important that the threads on the siphon hose coupling are properly
sealed. Any air leakage will produce erratic operation of the sprayer
and may damage the system. The up and the down strokes should
be approximately equal in time (one should not be faster than the
other). A fast up or down stroke may indicate air in the system or
malfunctioning valve or seats (see the Troubleshooting section).
PowrTwin Plus 17
GB
Maintenance
6.5 Basic Engine Maintenance (gas engine)
For detailed engine maintenance and technical specications
refer to the separate gasoline engine manual.
All service to the engine should be performed by a dealer
authorized by the engine manufacturer.
Use a premium quality motor oil. 10W30 is recommended for
general all temperature use. Other viscosities may be required
in other climates.
Use only a (NGK) BR-6HS (PT4900), or (NGK) BP6ES / BPR6E
spark plug (PT6900/PT8900/PT12000). Gap the plug to 0.028
to 0.031 In. (0.7 to 0.8 mm) Always use a spark plug wrench.
Daily
1. Check engine oil level, and ll as necessary.
2. Check gasoline level, and ll as necessary.
Always follow the fueling procedure outlined earlier
in this manual.
First 20 Hours
1. Change engine oil.
Every 100 Hours
1. Change engine oil.
2. Clean the sediment cup.
3. Clean and re-gap the spark plug.
4. Clean the spark arrestor.
Weekly
1. Remove the air lter cover and clean the element. In very
dusty environments, check the lter daily. Replace the
element as needed. Replacement elements can be purchased
from your local engine manufacturer dealer.
Engine Operation and Service
1. Clean and oil air lter pad on gasoline engine every 25 hours
or once weekly. Do not permit the air intake screen around
the y wheel of the gas engine to load up with paint or
trash. Clean it regularly. The service life and eciency of
the gas engine model depends upon keeping the gasoline
engine running properly. Change the oil in the engine
every 100 hours. Failure to observe this may result in engine
overheating. Consult the engine manufacturer’s service
manual provided.
2. To conserve fuel, service life, and eciency of the sprayer,
always operate the gasoline engine at the lowest RPM at
which it runs smoothly without laboring and delivers the
amount required for the particular painting operation.
Higher RPM does not produce higher working pressure. The
gasoline engine is connected to the hydraulic pump by a
pulley combination designed to produce full paint delivery at
maximum RPM.
3. The warranty on gasoline engines or electric motors is limited
to the original manufacturer.
18 PowrTwin Plus
GB
Troubleshooting
Problem
A. Spitting gun
B. Gun will not shut o
C. Gun does not spray
Problem
A. Pump delivers on upstroke only
or goes up slowly and down fast
(commonly called downstroke
dive)
B. Pump delivers on down stroke
only or goes up fast and down
slowly
C. Pump moves up and down fast,
delivering material
D. Pump moves up and down
slowly when spray gun is shut
o
E. Not enough uid pressure at
gun
F. Pump chatters on up or down
stroke
Cause
1. Air in system
2. Dirty gun
3. Needle assembly out of adjustment
4. Broken or chipped seat
1. Worn or broken needle & seat
2. Needle assembly out of adjustment
3. Dirty gun
1. No paint
2. Plugged lter or tip
3. Broken needle in gun
Cause
1. Lower foot valve ball is not seating due to
trash or wear
2. Material too viscous to siphon.
3. Air leaking in on siphon side or damaged
siphon hose. Siphon may be too small for
heavy material.
1. Upper ball is not seating due to trash or wear
2. Lower packing set is worn
1. Material container is empty or material is too
thick to ow through siphon hose
2. Bottom ball stuck to foot valve seat
3. Siphon hose is kinked or loose
1. Loose connections. Bleed valve is open
partially or bleed valve is worn. Lower
packing seat is worn.
2. Upper and/or lower ball not seating
1. Spray tip is worn
2. Outlet lter or gun lter is clogged
3. Low voltage and/or inadequate amperage
4. Hose size or length is too small or too long
1. Solvent has caused upper packing to swell
Solution
1. Inspect connections for air leaks.
2. Disassemble and clean.
3. Inspect and adjust.
4. Inspect and replace.
1. Replace.
2. Adjust.
3. Clean.
1. Check uid supply.
2. Clean.
3. Replace.
Solution
1* Remove foot valve assembly. Clean and inspect. Test
foot valve by lling with water; if ball fails to seal the
seat, replace ball.
2. Thin material — contact manufacturer for proper
thinning procedures.
3. Tighten all connections between pump and paint
container. If damaged, replace. Switch to larger diameter
siphon set.
1* Check upper seat and ball with water. If ball fails to seal,
replace seat.
2* Replace packing set if worn.
1. Rell with new material. If too thick, remove siphon
hose, immerse uid section in material, and start pump
to prime. Add thinner to material. Change to bigger
siphon set. Open bleed valve to remove air and restart
pump.
2* Remove foot valve. Clean ball and seat.
3. Straighten.
1. Check all connections between pump and gun. Tighten
as necessary. If material is owing from bleed hose, close
bleed valve or replace, if necessary. Should none of the
above be evident, replace lower packing.
2* Reseat balls by cleaning.
1. Replace.
2. Clean or replace lter.
3. Check electrical service. Correct as required.
4. Increase hose size to minimize pressure drop through
hose and/or reduce hose length.
1* Replace packing.
7. Troubleshooting
7.1 Airless Gun
7.2 Fluid Section
* Refer to the Service Manual (part number 2439109, available online) for complete instructions regarding this procedure.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Titan PowrTwin 4900, 6900, 8900, 12000 Plus Operation Manuel utilisateur

Catégorie
Systèmes de pulvérisation fine Power
Taper
Manuel utilisateur
Ce manuel convient également à