QOLSYS QZ2142-840 Manuel utilisateur

Taper
Manuel utilisateur
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
SPECIFICATIONS WARNING
Model:QZ2142-840 RISK OF FIRE
Power: 120 VAC, 60 Hz. RISK OF ELECTRICAL SHOCK
Signal (Frequency): 908.42 MHZ. RISK OF BURNS
Maximum load for outlet 500W Resistive CONTROLLING APPLIANCES:
Maximum load for the Z-Wave™ controlled outlet: EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL
APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT
Range: Up to 100 feet line of sight between the Wireless Controller ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave™ receiver module. MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES
Operating Temperature Range: 32-104° F (0-40° C) MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Specifications subject to change without notice OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
due to continuing product improvement REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
Website:dealers.qolsys.com
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
SmartPlug Dimmer
SmartPlug Dimmer Manual
Introduction:
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
QZ2142-840 is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product.
The Device Type of the QZ2142-840 is on/off power switch.
The Role Type of the QZ2142-840 is Always On Slave Role Type
Key Features:
---Remote ON/OFF control via the Z-Wave™ controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Support firmware upgrades via Over-the-air (need Gateways support)
---Support Scenes
Product Overview:
A AC plug
B Z-Wave controlled outlet
C ON/OFF/PROG Push button/ Status LED
Key function description
Function 1: Press the button to turn the output ON or OFF
Function 2: quickly press 3x Button: ADD(inclusion) (only if switch is not included in network)quickly press 3x Button:Remove( exclusion)
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 4: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
Network Wide Inclusion To A Z-Wave™ Network
1,Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
2,When prompted by your primary controller, click the button three times in one second.
The device is compatible with SmartStart
QR CODE
The QR code is found to the side of the case, DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached on the packaging box.
Command Class
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of
the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within
10 minutes of being switched on and in the network vicinity.
This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers.
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
Function 3: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
The device support two methods of inclusion,When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart,
A
B
C
Z-Wave™ Configuration Parameters
2Status LED Configuration
Paramter No: 2(0x02) Size:1 Byte
Value: 00(default) Output and the LED are in the different state.
Value: 01 Output and the LED are in the same state.
Value: 02 LED Always OFF
Value: 03 LED Always ON
3: Auto Turn-Off Timer
Paramter No: 3(0x03) Size=4
Values:0 (minutes) default;
Values: 1 – 65535 (minutes);
5: Auto Turn-Off Timer
Paramter No: 5(0x05) Size=4
Values:0 (minutes) default;
Values: 1 – 65535 (minutes);
8Restores state after power failure
Paramter No: 8(0x08) Size:1 Byte
Value: 00 Output OFF.
Value: 01 Output ON.
Value: 02 (default) The state before a power outage.
9: Ramp rateLocal Button + Z-Wave™
Paramter No: 9(0x09) Size=1Default =1
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
......
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
10: Multilevel minimum value can be setLocal Button
Paramter No: 10(0x0A) Size=1Default =1
Value=0 disable
Value=1
Value=2
......
Value=99
11: Multilevel maximum value can be setLocal Button
Paramter No: 11(0x0B) Size=1Default =99
Value=0 disable
Value=1
Value=2
......
Value=99
12:Double Tap Behavior---when switch is off and quickly press button 2 times, switch turns on to x brightness
Paramter No: 12(0x0C) Size=1Default =0
Value=0 enable double tap to full brightness (99)
Value=1 custom value set in parameter 18
Value=2 enable double tap to maximum brightness (turn on to the value relate with parameter 11)
Value=3 disable double tap to full brightness
15: Enable or Disable local / Z-Wave™ control
Paramter No: 15(0x0F) Size:1 ,Default =1
Value: 00 disable
(when paddle pressed switch will not turn light on or off BUT it will still control the light via Z-Wave™ and
it will change LED indicator status and on/off/multilevel status when paddle is pressed)
Value: 01 enable (normal operation like now)
Value: 02 disable local and Z-Wave™ control
(LED and on/off status will still change if paddle pressed) >>
make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled
16: dimmer speed (only for local press & hold)
Paramter No: 16(0x10) Size=1Default =5
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
......
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
20: Association reports
Paramter No: 20(0x14) Size:1 ,Default =2
Value: 00 Z-Wave™ controlMultilevel report (without each level,just final level)
Manual control (short press): Basic report(without each level,just final level)
Manual control(long press & relay enable): Basic report(without each level,just final level)
Manual control(long press & relay disable): Multilevel report (each level will be reported)
Value: 01 Z-Wave™ controlMultilevel report (without each level,just final level)
Manual control (short press): Basic report(without each level,just final level)
Manual control(long press & relay enable OR disable): Basic report
Value: 02 Z-Wave™ controlMultilevel report (without each level, just final level)
Manual control (short press): Multilevel report (without each level, just final level)
Manual control (long press & relay enable): Multilevel report (without each level, just final level)
Manual control (long press & relay disable): Multilevel report (each level will be reported)
21: Disabled Relay Behavior
Paramter No: 21(0x15) Size:1 ,Default =0
Value: 00 report on/off and multilevel status when paddle is pressed and change LED indicator status and
Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20
Value: 01 DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and
Parameter 15 is set to value 0 or 2 (output control disabled).
22: Night Mode Brightness Level---Set the level of brightness the dimmer will turn on to when off and held Button for 2 seconds
Paramter No: 22(0x16) Size:1 ,Default =0
Value: 00 disable function
Value: 01-99
23: LED Indicator Color
Paramter No: 23(0x17) Size=1Default =1
Value=0 White
Value=1 Blue
Value=2 Green
Value=3 Red
26: LED Indicator Brightness
Paramter No: 26(0x18) Size=1Default =1
Value=0 Bright (100%)
Value=1 Medium (60%)
Value=2 Low (30%)
You may use the below configuration parameters to change settings of the corresponding functionality.
Support for Association Groups
QZ2142-840 supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for QZ2142-840 Status change report,
1. QZ2142-840 will trigger AUTO report function if the Switch status had been changed.
(ex.Switch Multilevel Report/Indicator Report/Central Scene Notification/ Device Reset Locally Notification)
Association group_2:basic set command on/off controlt
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command on/off controlt
command. On (0xFF) or Off (0x00) to its associated group.
Basic Command Class
The basic command class is mapped to the SWITCH MULTILEVEL command class
Restoring Factory Defaults
QZ2142-840 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set
When the output of the QZ2142-840 is changed, On (0xFF) or Off (0x00). The QZ2142-840 will automatically send out a related basic set
Association Groups
Root Device Endpoint1 Endpoint2
Group 1:Lifeline Group 1:Lifeline Group 1:Lifeline
Group 2:Basic set From Endpoint1 Group 2:Basic set command Group 2:Basic set command
Group 3:Basic set From Endpoint2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

QOLSYS QZ2142-840 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues