EVA LOGIK ZW97 Manuel utilisateur

Taper
Manuel utilisateur
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
ZW97 Smart Plug(2 Channel) Manual
Ourdoor Smart Plug(2-Channel)
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS WARNING
Model:ZW97
RISK OF FIRE
Power: 120 VAC, 60 Hz.
RISK OF ELECTRICAL SHOCK
Signal (Frequency): 908.42 MHZ.
RISK OF BURNS
Maximum load for outlet 15A, 1200W Resistive
CONTROLLING APPLIANCES:
Maximum load for the Z-Wave controlled outlet:
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE DEVICES TO CONTROL
600W Incandescent, ½ HP Motor or 1200W Resistive
APPLIANCES. OPERATION OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
Range: Up to 100 feet line of sight between the Wireless Controller
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave receiver module.
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-WAVE DEVICES
Operating Temperature Range: 32-104° F (0-40° C)
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
For Ourdoor use
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Specifications subject to change without notice
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
due to continuing product improvement
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
THE FOLLOWING:
Website:www.ishowlights.com
DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
The ZW9
7
is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW97 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Over temperature protection
---Support firmware upgrades via Over-the-air (need Gateways support)
Product Overview:
A AC plug
B Z-Wave controlled outlet-1
C Z-Wave controlled outlet-2
D ON/OFF/PROG Push button
E Status LED
Z-Wave Remote Control
ADD or Remove the ZW97 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
Include ZW97 to/from a Z-Wave Gateway with supporting Security.The ZW97 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.
Z-Wave MULTI_CHANNEL
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
---When prompted by your primary controller, click the PROG button five times in one second.
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
E
A
B
C
D
Z-Wave MULTI_CHANNEL
ZW97 is multi channel device
It has two endpoints. Outlet-1 is Endpoint1, outlet-2 is Endpoint2.
ZW97 Endpoint1 / Endpoint2 Device Type
Generic Device Class: GENERIC_TYPE_SWITCH_BINARY
Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY
z-wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_MULTI_CHANNEL_V4,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
ZW97 protocol Endpoint 1
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
ZW97 protocol Endpoint 2
Full Command Class Node Info
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
Z-Wave Configuration Parameters
1:
Status LED Configuration
Paramter No: 1(0x01) Size:1 Byte Value: 00(default) outlet on,led on.
Value: 01 outlet on,led off.
Value: 02 led no work.
2:
Count Down Configuration(Turn off the output by time
Paramter No: 2(0x02) Size:2 Byte Value: xx xx Turn off left outlet
Turn off Endpoint1 outlet
Value Scope :0----36000S (default:00 00 no timer)
Paramter No: 3(0x03) Size:2 Byte Value: xx xx Turn off right outlet
Turn off Endpoint2 outlet
Value Scope :0----36000S (default:00 00 no timer)
You may use the below configuration parameters to change settings of the corresponding functionality.
Support for Association Groups
ZW97 supports 3 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association groups.
Association group_1:Z-Wave Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW97 Status change report,
1. ZW97 will trigger AUTO report function if the Switch status had been changed.
2. When ZW97 high temperature alarm sends out notifications or releases notifications, ZW97 will auto report
Association group_2:basic set command
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command
command. On (0xFF) or Off (0x00) to its associated group.
Support for Over temperature protection
ZW97 support Over temperature protection,When the temperature is greater than 105 degrees Celsius, the Heat Alarm signal is sent out
Notification Type : Heat Alarm 0x04 . Event :Overheat detected 0x02
Restoring Factory Defaults
ZW97 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
MANUAL RESET
---Power off ZW97
---keep holding the PROG button
---Power on,Press and keep holding the PROG button for no less than 10 seconds.
Remark : All the setting and data will be permanently deleted.
When the output of the ZW97 Enpoint2 socket is changed, On (0xFF) or Off (0x00). The ZW97 will automatically send out a related
When the output of the ZW97 Enpoint1 socket is changed, On (0xFF) or Off (0x00). The ZW97 will automatically send out a related
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

EVA LOGIK ZW97 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues