Minoston MR40Z Manuel utilisateur

Taper
Manuel utilisateur
S2 Smart Wall Control Manual
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment S2 Smart Wall Control
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS WARNING
Model:MR40Z RISK OF FIRE
Power: 2*CR2032 batteries RISK OF ELECTRICAL SHOCK
Signal (Frequency): 908.42 MHZ. RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL
APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT
Range: Up to 100 feet line of sight between the Wireless
Controller
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
and the closest Z-Wave™ receiver module. MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES
Operating Temperature Range: 32-104° F (0-40° C) MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Specifications subject to change without notice OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
due to continuing product improvement REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
Website:www.nie-tech.com DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-Wave™ network with other Z-Wave Plus™ certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
MR40Z is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product.
The Device Type of the MR40Z is PORTABLE REMOTE CONTROLLER
The Role Type of the MR40Z is Reporting Sleeping Slave Role Type
Product Overview:
A. Up Push button
B. Down Push button
C. Left Push button
D. Right Push button
E. LED indicator
Key function description
Function 1: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 2: quickly press 6x upper paddle: ADD (inclusion) (only if switch is not included in network)
Function 3: quickly press 6x lower paddle: Remove (exclusion)
Function 4: quickly press 7x upper paddle: Wake up
Function 4: tap-tap-tap’and’hold to reset, LED indicator will blink red 5 times to confirm successful reset
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Adding Your Device To A Hub
The device support two methods of inclusion,When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart,
Network Wide Inclusion To A Z-Wave™ Network
1,Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
2,When prompted by your primary controller, click the Up or Down button six times in one second.
The device is compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of
the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within
10 minutes of being switched on and in the network vicinity.
QR
CODE
the QR code are sticked to the side of the case,DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached on the packaging box.
Command
Class
A
B
C
MR40Z
PIN:50714
A
B
CD
E
You may use the below configuration parameters to change settings of the corresponding functionality.
1: LED Indicator Mode
Paramter No: 1(0x01) Size:1 Byte (default=1)
Value: 00 LED always off
Value: 01 LED normal mode
Value: 02 LED always on in color specified in Parameter 2
Value: 03 LED always on in color specified in Parameter 3
2:LED Indicator Color for Upper paddle remote control (Scene 1 activation)
Paramter No: 2(0x02) Size:1 Byte (default=1)
Value: 00 White
Value: 01 Blue
Value: 02 Green
Value: 03 Red
Value: 04 Magenta
Value: 05 Yellow
Value: 06 Cyan
3: LED Indicator Color for Lower paddle remote control (Scene 2 activation)
Paramter No: 3(0x03), Size=1 Byte (default=0)
Value: 00 White
Value: 01 Blue
Value: 02 Green
Value: 03 Red
Value: 04 Magenta
Value: 05 Yellow
Value: 06 Cyan
Support for Association Groups
MR40Z supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave Plus™ Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MR40Z Status change report,
1. MR40Z will trigger AUTO report function if the Switch status had been changed.
(ex.Battery Report/Central Scene Notification/ Device Reset Locally Notification/Indicator Report)
Association group_2:BASIC SET
1:Up button press 1x send basic set 0xff
2:Down button press 1x send basic 0x00
Association group_3:SWITCH_MULTILEVEL_CHANGE
1:Up/Down button hold more than 0.5s send SWITCH_MULTILEVEL_START_LEVEL_CHANGE(Dim Up/Dim Down)
2:Up/Down button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
Restoring Factory Defaults
MR40Z is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:tap-tap-tap’and’hold to reset, LED indicator will blink red 5 times to confirm successful reset
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.