Square D SQR62101WHZ Manuel utilisateur

Taper
Manuel utilisateur
____________________________________________________________________________________________
© 2020 Schneider Electric All Rights Reserved
TM
SQR62101WHZ Z-Wave Plug-in
FCC ID: 2AUCU-62101Z
Retain for future use.
Features
Duplex outlets, one outlet is always on, another outlet is Z-Wave controlled.
Wireless Z-Wave technology creates a mesh network for command and
control interoperability with other Z-Wave compliant controllers and devices.
Manual and remote ON/OFF control of any lighting or other electrical load
connected to Z-Wave controlled outlet.
Measure the energy usage of the connected loading on the Z-Wave controlled
outlet, display the actual consumption (in W) and the accumulated power used
(in kWh) in the user interface of the gateway.
NOTE:
Please refer to the gateway installation manual for energy usage display
and energy measurement features.
SQR44101**Z Z-Wave Plug-in Outlet, Energy Monitoring, 15A 125VAC Specifications
Voltage 125 Vac, 60 Hz
Regular
outlet Current 15A
Controlled
Outlet
Incandescent 1000 W
LED 5A
Standard Ballast 1200VA
Resistive 15A
Motor 1/2 Hp
Operating temperature 32104°F (040°C)
Wireless type Z-Wave (Support S2 and SmartStart)
Wireless frequency 908.40 MHz / 908.42 MHz / 916 MHz
Instruction Bulletin GDE77980_Eng, 07/2020
SQR62101WHZ Z-Wave Plug-in Instruction Bulletin
2 © 2020 Schneider Electric All Rights Reserved GDE77980_Eng
Precautions
CAUTION
HAZARD OF UNINTENDED USE
This Z-Wave plug-in is intended to be used for non-critical automation activities.
It is not intended to support life, safety, or medical equipment.
Failure to follow these instructions can result in personal injury or
equipment damage.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Apply appropriate personal protective equipment (PPE) and follow safe
electrical work practices. See NFPA 70E, NOM-029-STPS or CSA Z462 or
local equivalent.
Don’t touch metal pins during plug in or out.
Indoor use only.
Failure to follow these instructions will result in death or serious injury.
WARNING
HAZARD OF HEAT AND FIRE DAMAGE
Read all instructions before installation. The manufacturer will not be held
responsible for product damage resulting from not following the instructions.
Wet hands are strictly prohibited.
Work strictly according to the rated load.
Do not continue working after self-disassembly of any nature and damage of
external forces.
Failure to follow these instructions can result in death, injury or
equipment damage.
WARNING: This product can expose you to chemicals including Carbon black, which is
known to the State of California to cause cancer, and Bisphenol A (BPA), which is
known to the State of California to cause birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.
Instruction Bulletin SQR62101WHZ Z-Wave Plug-in
GDE77980_Eng © 2020 Schneider Electric All Rights Reserved 3
Installation
Operation
1. Local control:
Press the program button, the appliance or device plugged into Z-Wave controlled
outlet will turn ON or OFF.
NOTE: After a power failure, the Z-Wave controlled outlet returns to the off state.
2. Group control the nodes of association group 2:
Press the program button twice within 1s (the interval between two presses is less
than 0.5s), the deice can turn on/off the other Z-Wave devices in the same
association group.
SQR62101WHZ Z-Wave Plug-in Instruction Bulletin
4 © 2020 Schneider Electric All Rights Reserved GDE77980_Eng
NOTE: Please refer to association setting for nodes group 2 setup. This requires a
gateway with advanced features and assumes the device is included in a network.
3. Inclusion to a Z-Wave network:
NOTE: The device supports S2-authenticated & S2-unauthenticated inclusion method, It
is highly recommended to only select S2-authenticated or the highest inclusion method
for inclusion, and deselect other methods. This ensures the highest security level during
Z-Wave service. During S2-authenticated inclusion, users may be asked to scan the QR
code or enter a 5-digit pin code attached on the device.
A. SmartStart inclusion: The feature assumes the gateway has implemented
SmartStart. Users could use the APP of the gateway or the gateway camera to scan
the QR code on device or on device package before powering on the device, and
then when the device is powered on, it shall be automatically added to the gateway.
B. Manual inclusion: When the gateway is in adding mode (please refer to the
instruction of the Z-Wave gateway for the operations on gateway itself), press the
program button 3 times within 1.5s (the interval between each press is less than
0.5s).
4. Exclusion from a Z-Wave network: When the gateway is in removing mode (please
refer to the instruction of the Z-Wave gateway for the operations on gateway itself),
press the program button 3 times within 1.5s (the interval between each press is
less than 0.5s).
5. Remote control: After the device is included in a Z-Wave gateway, the gateway can
provide control of an individual device, groups of devices and scenes, and offers
flexibility in setting up the lighting control network. Please refer to the gateway
instructions for details.
Wireless Range Conditions
The wireless range is the effective distance of remote control and it will be
impacted by the following conditions:
Each wall or obstacle (e.g., refrigerator, TV, etc.) between the remote or Z-
Wave device and the destination device will reduce the wireless range.
Brick, tile, or concrete walls block more of the wireless signal than walls made
of wooden studs and plasterboard (drywall).
The angle of direction between the remote or Z-Wave device and the
destination device will also impact the wireless range; normally, placing the Z-
Wave device face-to-face will get the best wireless range.
Wall-mounted Z-Wave device installed in metal junction boxes may suffer a
significant loss of range since the metal box blocks a large part of the wireless
signal.
Instruction Bulletin SQR62101WHZ Z-Wave Plug-in
GDE77980_Eng © 2020 Schneider Electric All Rights Reserved 5
6. Reset to factory defaults:
Press the program button 3 times then press and hold it for more than 10s.
NOTE:
Use this procedure only when the Z-Wave gateway is missing or otherwise
inoperable.
Reset the device to factory default settings will set the device to not in Z-Wave
network state, delete the association setting and restore the configuration
setting to the default.
When the program button is pressed and held, the LED indicator will blink
quickly for 10 seconds and then the program button can be released after the
LED change to solid on, the LED will blink quickly for 3 seconds when factory
reset succeeds.
Advanced Setting The advanced setting requires an advanced gateway. Basic gateway does not
support this setting. Users can do the setting through the interface of the advanced
gateway.
All configuration parameters can be restored to factory default settings by the
gateway or by manual reset.
Configuration
Parameter No.
Size
Description
Valid Value
Default Value
1
1 byte
Synchronization of load
power and LED indicator
0 = Power ON, LED OFF
Power OFF, LED ON
Default = 1
1 = Power ON, LED ON
Power OFF, LED OFF
Association
Grouping ID
Max. No. of Nodes
Description
1
5
Lifeline: Send device reset locally notification
MultiLevelReport: Dimming percentage report
MeterReport: Power metering report
2
5
AssGroupSet: send on/off set command
LED Indication
Blue LED flashing
LED blinking slowly for 3 minutes: device not in network
LED blinking fast: adding/leaving network
LED stays on for 1 minute: adding/leaving network successfully
LED blinking fast for 3s: factory reset success
Blue LED on
Switch is turned on (default setting, can be configured)
SQR62101WHZ Z-Wave Plug-in Instruction Bulletin
6 © 2020 Schneider Electric All Rights Reserved GDE77980_Eng
Blue LED off
Switch is turned off (default setting, can be configured)
Trouble shooting
Issue
Possible Cause/Solution
SmartStart inclusion taking too long
Power cycle the switch to escalate the inclusion.
Inclusion is unsuccessful
Move the switch closer to the gateway and repeat the inclusion
operation.
FCC Statement
Federal Communication Commission Interference Statement
The equipment has been tested and found to comply with the limits for a class B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment uses, generates and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter or antenna.
Non-modification Statement:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC
Supplier’s Declaration of Conformity
Product Name: Z-Wave Plug-in
Model Number: SQR62101WHZ
Suppliers Name: Schneider Electric
Suppliers Address (USA) : 800 Federal Street Andover, MA 01810 USA
Suppliers Website: www.schneider-electric.us
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s
licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
L’appareil ne doit pas produire de brouillage;
L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être maintenue entre
l'antenne de cet appareil ettoutes les personnes.
Model Number: SQR62101WHZ
Instruction Bulletin SQR62101WHZ Z-Wave Plug-in
GDE77980_Eng © 2020 Schneider Electric All Rights Reserved 7
Warranty Information
Schneider Electric warranties its products to be free of defects in materials and workmanship for a period of two (2) years. There are no
obligations or liabilities on the part of Schneider Electric for consequential damages arising out of or in connection with the use or performance of
this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation.
Schneider Electric USA, Inc.
800 Federal Street
Andover, MA 01810 USA
888-778-2733
www.se.com/us
Electrical equipment should be installed, operated, serviced, and maintained only by
qualified personnel. No responsibility is assumed by Schneider Electric for any
consequences arising out of the use of this material.
Schneider Electric and Square D are trademarks and the property of
Schneider Electric SE, its subsidiaries, and affiliated companies. All other trademarks
are the property of their respective owners.
© 2020 Schneider Electric All Rights Reserved
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Square D SQR62101WHZ Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues