HID Global Signo Guide d'installation

Taper
Guide d'installation
hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE
HID® Signo™ 25B
Biometric Reader/Controller
13.56 MHz / 2.4 GHz Contactless
SRD Model: Signo 25B PLT-04026 Rev. B.1
2 Wire the 25B
5 Download and install HID Biometric Manager
Optional Features
Open Collector Output – Controls an external device (5 VDC) operating in Host
Mode only. Sink 40 mA / Source -1 mA.
Optical Tamper – If connected via the pigtail wires, the optical tamper will sink to
ground from the default of 5 VDC when the reader is removed from its backplate.
Relay Output – Typically used to control a strike lock. Three contacts are available
on the pigtail wires (common, normally open, and normally closed).
Wiegand Reader Interface – There is Wiegand output available, as marked on the
pigtail wires. Configuration options are available within HID Biometric Manager™.
Visit https://www.hidglobal.com/signo25b and
download the HID Biometric Manager Installer. Once
the .exe file has downloaded, double-click the file to
install HID Biometric Manager, following the on-screen
prompts.
For further details, refer to the HID Signo Biometric
Reader/Controller 25B Administration Guide
(PLT-04029), which is available for download from
https://www.hidglobal.com/signo25b
Screws not supplied.
1
2
© 2019 - 2020 HID Global Corporation/ASSA ABLOY AB. All
rights reserved. HID, the HID Brick logo, the Chain Design,
HID Signo, HID Biometric Manager, and HID Mobile Access are
trademarks or registered trademarks of HID Global, ASSA ABLOY
AB, or its aliate(s) in the US and other countries and may not
be used without permission. All other trademarks, service marks,
and product or service names are trademarks or registered
trademarks of their respective owners.
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
1 Mount the backplate
Function
Group Wire Color Function AWG Max
Length1
RS-485
Green RS-485 A
24 4000 ft
(1,219 m)
Ta n RS-485 B
Black RS-485 Ground
Relay
Gray Relay – Common
22 500 ft
(152 m)
Yellow Relay – Normally
Open
Orange Relay – Normally
Closed
Inputs
(Controller
mode only)
Pink REX Input
(Supervised)
Gray DPS Input
(Supervised)
Black Input Ground
Wiegand
Port
Green D0
White D1
Brown RED
Orange Green
Yellow BUZ
Blue Hold
Violet TPR
Black Ground
DC Power Red Power +12V
Black Power Ground
Function
Group Connector Function Max Length
Network RJ45
socket Ethernet 328 ft (100 m)
(CAT5/CAT5E/CAT6)
4 Power and test the reader
Light bar.
Biometric reader (requires set up
in HID Biometric Manager)
1RS-485 = Max bus length 4,000 ft - 24 AWG (1,219 m)
Max length between nodes: 1,640 ft - 24 AWG (500m)
IMPORTANT: The 19 pigtail wires should be cut to size for wall mounted application.
IMPORTANT: DO NOT cut the Ethernet cable.
Note: Wiring the reader incorrectly may permanently damage the reader.
Turn on the power.
The reader should beep and the
light bar should flash.
Test the reader with a card.
The reader should beep and the
light bar should flash.
Ethernet cable
18" (0.46m)
Pigtail wires
18" (0.46m)
3 Secure the 25B to the backplate
1
1
2
1. Insert the reader into the backplate.
2. Latch the reader.
3. Secure the reader to the backplate
using the supplied screw.
3
Supplied parts
HID Signo Biometric Reader/Controller 25B (1)
Installation Guide (1)
Screw (1) – for attaching the reader to the backplate
Recommended parts (not supplied)
Cable, 5-9 conductor (Wiegand), 4 conductor Twisted Pair Over-All Shield and
UL approved, Belden 3107A or equivalent (OSDP)
Certified LPS DC power supply
Security tool HID 04-0001-03 (for anti-tamper screw)
www.hidglobal.com/PLT-04027
Scan the QR code or visit the link to
see the multi-language electronic
version of this document.
Lisez le code QR ou suivez le lien pour
consulter la version française de ce
document.
Escanee el código QR o visite el
vínculo para consultar la versión en
Español de este documento.
Scannen Sie den QR-Code oder öffnen
Sie den Link für die deutsche Version
dieses Dokuments.
Faça a leitura do código QR ou acesse
o link da versão em português deste
documento.
Scansiona il codice QR o visita il
link della versione Italiana di questo
documento.
Отсканируйте QR-код или пройдите по
ссылке, чтобы получить версию этого
документа на русском языке.
扫描QR码或访问此文档的中文版本的链接。
の文書の日本語版を表示するには、QRコー
ドをスキャンするか、ンクをクリクします
QR코드를 스캔하거나 링크를 방문하면 이
문서의 한국어 버전을 볼 수 있습니다.
hidglobal.com An ASSA ABLOY Group brand
Powering
Trusted Identities
PLT-04026 Rev. B.1
15 Equipment
8T2 9
ACC Control READER
General Signaling
Equipment
E4662 ABCD12345678
Brazil
Condomínio Business Center
Av. Ermano Marchetti, 1435
Galpão A2 - CEP 05038-001
Lapa - São Paulo / SP
Brazil
Phone: +55 11 5514-7100
Asia Pacific
19/F 625 King's Road
North Point, Island East
Hong Kong
Support: 852-3160-9833
Fax: 852-3160-4809
Americas & Corporate
611 Center Ridge Drive
Austin, TX 78758
USA
Support: 866-607-7339
Fax: 949-732-2120
Europe, Middle East & Africa
3 Cae Gwrydd
Green Meadow Springs
Cardi
CF15 7AB
United Kingdom
Phone: +44(0) 2920 528 500
Specifications
Input
Voltage
Current
Operating Temperature
Standby
AVG1
Max
AVG2Peak3
12 VDC 800 mA 1.5 A 2 A -4° F to 150° F
(-20° C to 66° C)
1
 Standby AVG - Root Mean Square current draw without a card in the RF field.
2
 Maximum AVG - Root Mean Square current draw during continuous card reads. Not evaluated by
UL.
3
 Peak - highest instantaneous current draw during RF communication.
Regulatory
UL
Connect only to a Listed Access Control / Burglary LPS power supply. These
readers are intended to be used with listed (UL294) control equipment. Suitable for
outdoor use.
Only Wiegand and Bluetooth communications have been evaluated by UL.
The Open Collector Output has not been evaluated by UL.
RS485 communications has not been evaluated by UL.
Inputs (reserved for future use) have not been evaluated by UL.
The Ethernet connection is for supplemental use; the unit is connected to an Access
Control Panel.
The Signo 25B Biometric Reader is compatible with HID Mobile Access® version
3.3.1 and later using mobile devices with BLE version 4.2 and later listed at:
https://www.hidglobal.com/mobile-access-compatible-devices
Install in accordance with NFPA70 (NEC) Local Codes, Canadian Electrical Code
CSA 22.1, and authorities having jurisdiction. Follow all National and Local Codes.
UL 294 Performance Levels
Model #
Access
Control Line
Security
Level
Destructive
Attack
Level
Endurance
Level
Stand-by
Power
Level
Conditions
25B Level I Level I Level IV Level I
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con
los requisitos esenciales y otras disposiciones relevantes de la Directiva 2014/53/
EU.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes
aux exigences essentielles et aux autres stipulations pertinentes de la Directive
2014/53/EU.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em
conformidade com as exigências essenciais e outras condições da diretiva 2014/53/
EU.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und
anderen relevanten Bestimmungen der Richtlinie 2014/53/EU erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e
ad altre misure rilevanti come previsto dalla Direttiva europea 2014/53/EU.
Download copies of the Radio Equipment Directive (RED) Declaration of
Conformity (DoC) at: http://www.hidglobal.com/certifications.
To ensure that RF exposure levels remain at or below the tested levels, a minimum
safe separation distance of 10 mm between the user and the reader is required for
RF exposure compliance.
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
FCC
This device complies with part 15, subpart C, of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation. These limits are designed to provide
reasonable protection against harmful interference. This equipment generate,
uses and can radiate RF energy and if not installed and used in accordance with
instruction, may cause harmful interference. Possible solution include: relocate
the device, increase separation between equipment, power equipment separately,
consult with your dealer.
CAUTION: Any changes or modifications to this device not explicitly approved by
HID Global could void your authority to operate this equipment.
Taiwan
根據NCC低功率電波輻射性電機管理辦法規定:
第十二條 經型式認證合格之低功率射頻電機非經許可公司、商號或使用者均不得擅自變
更頻率、加
大功率或變更原設計之特性及功能。
第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象
應立即停
並改善至無干擾時方得繼續使用。
前項合法通信指依電信法規定作業之無線電通信。
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之
干擾。
South Africa Australia and New Zealand
TA-2019/920
APPROVED
E4662
UAE
TRA
REGISTERED NO:
ER72356/19
DEALER NO:
DA37204/14
Singapore
Complies with
IMDA Standards
DA103548
Brazil
Este equipamento não tem direito à proteção contra interferência prejudicial e não
pode causar interferência em sistemas devidamente autorizados.
  • Page 1 1
  • Page 2 2

HID Global Signo Guide d'installation

Taper
Guide d'installation

dans d''autres langues