Jøtul GF 370 DV Adjustment Instructions

Taper
Adjustment Instructions
Jøtul GF 370 DV
Direct Vent Gas Stove
High Altitude
Adjustment Instructions
Kit 156821 for LP
Kit 156822 for NG
This derating kit shall be installed
by a qualified service agency in ac-
cordance with the manufacturer’s
instructions and all applicable
codes and requirements of the
authority having jurisdiction. If the
information in these instructions is
not followed exactly, a fire, explo-
sion, or production of carbon mon-
oxide may result causing property
damage, personal injury or loss of
life. The qualified service agency is
responsible for the proper instal-
lation of this kit. The installation is
not proper and complete until the
operation of the converted appli-
ance is checked as specified in the
manufacturer’s instructions sup-
plied with the kit.
Cet équipement de conversion sera
instal par une agence qualifiée de
service conformément aux instruc-
tions du fabricant et toutes exigences
et codes applicables de lautorisés
avoir la juridiction. Si l’information
dans cette Instruction n’est pas suivie
exactement, un feu, explosion ou pro-
duction de protoxyde de carbone peut
résulter le dommages causer de pro-
pr, pert ou blessure personnelle
de vie. Lagence qualifiée do service
est esponsable de l’installation pro-
pre de cet équipemetn. Linstallation
nest pas propre et compte jusquà
l’operation de l’appareil converi est
chéque suivant les crires établis
dans les instruction de propriétaire
provision nées avel l’équipement.
CAUTION: Before proceeding
with this conversion, the gas sup-
ply must be shut off prior to dis-
connecting the electrical power.
ATTENTION: Avant de procéder à cette
conversion, l’approvisionnement en
gaz doit être coupée avant de dé-
brancher l’alimentation électrique.
2


Figure 2. Primary air Shutter location
Figure 3.
Install new injector.
For U.S & Canada per
ANSI Z21.88-2005•CSA 2.33-2005, CAN/CGA 2.17
For installations from 610-1370 meters (2000-4500 ft.)
the orifice sizes (DMS) for natural and propane gas are
#39 and #53 respectively. See data plate for additional
information. For high altitude installations consult the
local gas distributor or the authority having jurisdic-
tion for proper rating methods. If the installer must
convert the unit to adjust for varying altitudes, the
information sticker must be filled out and applied to
the appliance at the time of the conversion.
Cet appareil est equippé pour des altitudes compries
entre 0 et 2000 pieds (0-610 m ) seulement.
Derating Procedure
1. Turn off gas supply to the stove and disconnect
from electical power source.
2. Remove the glass frame. See fig. 1.
3. Loosen the primary air shutter wingnut and push
the stem all the way back. Fig. 2.
4. Pull the Burner Plate forward to disengage it from
the burner orifice and lift it out of the firebox.
5. Locate the main burner injector. See fig. 3. Slide
the Air Shutter out of the way and use a 1/2” open
end wrench or deep-well socket to remove the
burner orifice from the brass orifice holder. Re-
place with the orifice supplied in the kit. Tighten
securely.
6. Reinstall the Burner Plate by engaging the ven-
turi tube with the Air Shutter. BE CERTAIN THE
BURNER IS LEVEL AND SECURELY SEATED ON THE
SUPPORT LEGS ON THE FIREBOX FLOOR.
7. Apply the Conversion Notice label to the rating
plate or base of the valve compartment.
8. Install the burner media, (Log Set, River Rocks, or
glass embers) according to the instructions in the
Owner’s Manual.
9. Apply anti-seize lubricant to the socket head glass
frame screws before reinstalling the glass frame.
10. Gas Pressure Test: See Owner’s Manual, page 15.
System Check: See Owner’s Manual, pages 22-23.
High Altitude Adjustment Kit
LP #156821 / NG #156822
Tools required:
• 1/2” & 13 mm open end wrench or deep-well socket
• 4 mm allen wrench
Conversion Kit Contents:
• 1 Burner Injector (#52 for LP / #38 mm for NG)
• Conversion Label
• Conversion instructions
Figure 1. Remove glass frame.
Injector
Primary Air
Shutter
Figure 4. High Altitude Conversion Label.
This appliance has been converted for use at an
altitude of___________ .
Orifice Size: __________ Manifold Press. _______
Input Btu/Hr. _________ Fuel Type ___________
Date: ___/___/___ Converted by:_____________
Cet appreeil a été converti au _____ Injecteur_____