WARNING:
This Quick Reference Guide is not a substitute for reading the operator’s manual. To
reduce the risk of injury or death, user must read and understand operator’s manual
before installing or using this product. All page references refer to the operator’s manual.
ASSEMBLY
INSTALLATION
GD200A QUICK REFERENCE GUIDE
Make the most of your purchase! Go to www.ryobitools.com and register your
new tool online. For questions about operating or maintaining
your product, please call, 1-877-205-5714.
Insert outer trolley into the end rail. Slide the inner and outer
trolley’s together until they engage. (See page 16).
Assemble the rails (see page 16).
Pull the front pulley through the end rail and into a sleeve.
(see page 16).
Install pulley rod and front brace (see page 17).
2
3
4
Place sprocket onto power head (see page 18).
Adjust belt tension (see page 18).
Place rail assembly onto power head (see page 19).
Secure rail assembly to power head. Raise Wi-Fi antenna to
upright position. (See page 19).
Check the condition of the door and identify the spring type
(see page 21).
Measure and cut mounting straps that are a half inch longer
than the distance between the header bracket and the ceiling.
Mount power head to the ceiling (see page 26).
NOTE: The proper configuration and placement of mounting
straps will vary based on the design and construction of your
garage ceiling.
Remove tape and position RF antenna beneath the garage door opener
for better signal reception between your opener and the outdoor keypad.
The garage door opener will not
open or close until the travel limits
have been properly set. Refer to
page 38 of the operator’s manual
for details.
Install indoor keypad and entrapment label (see page 33).
Attach the emergency release rope (see page 27).
Install the header bracket (see page 23).
Install the door bracket (see page 27).
NOTE: Installation varies for single panel and wooden garage
doors. See page 28 for details.
Wire indoor keypad and safety sensors (see pages 32 and 33).
NOTE: Strip 1/2 in. of insulation from the ends of each wire
prior to installation.
Attach rail assembly to header bracket (see page 24).
Install center brackets (not included) to joists (see page 26).
1 6
5
7
8
1 5 8
9
10
11
6
2
7
3
4
Child can become trapped or pinned under an automatic garage door resulting
in serious injury or death.
• Do not allow children to walk or run under a closing door.
• Do not allow children to operate door opener controls.
• Always keep a closing door within sight.
• In the event a person is trapped under the door, push the control button or
use the emergency release.
• This operator system is equipped with an unattended operation feature. The
door could move unexpectedly. Not intended for use with single panel garage
doors.
Test door opener monthly:
• Refer to Operator’s Manual.
• Use a 1 ½ inch thick object (or 2 X 4 laid flat) placed on the floor under the
closing door.
• In the event the door does reverse upon contact, adjust, repair, or replace the
opener.
Do not remove or paint over this label.
Mount this label next to the wall control.
Mount the wall control out of the reach of children at least 5 feet above the floor.
Child can become trapped or pinned under an automatic garage door resulting
in serious injury or death.
• Do not allow children to walk or run under a closing door.
• Do not allow children to operate door opener controls.
• Always keep a closing door within sight.
• In the event a person is trapped under the door, push the control button or
use the emergency release.
• This operator system is equipped with an unattended operation feature. The
door could move unexpectedly. Not intended for use with single panel garage
doors.
Test door opener monthly:
• Refer to Operator’s Manual.
• Use a 1 ½ inch thick object (or 2 X 4 laid flat) placed on the floor under the
closing door.
• In the event the door does reverse upon contact, adjust, repair, or replace the
opener.
Do not remove or paint over this label.
Mount this label next to the wall control.
Mount the wall control out of the reach of children at least 5 feet above the floor.
Connect door bracket to outer trolley (see page 29).
NOTE: Installation varies for single panel doors. See page 30
for details.
Assemble and install safety sensors (see page 31).
Align sensors until they are directly facing each other
(see page 38).
End Rail
End Rail
End Rail
Support Rail
Support Rail
Support Rail
Rail Assembly
Front Pulley
Sleeve
Sleeve
Sleeve
Sleeve
Outer
Trolley
Inner
Trolley
Tension
Nut
Tension
Nut
Spring
Front Brace
Front Pulley
Pulley Rod
Nut
Bracket
Sprocket
Round
Side
An installation video can be found by searching YouTube for “OFFICIAL RYOBI Garage Door Opener Installation
Une vidéo d’installation peut être trouvée en effectuant une recherche sur YouTube pour « OFFICIAL RYOBI Garage Door Opener
Installation » (Installation d’un ouvre-porte de garage Ryobi officiel).
Puede encontrar un video de instalación buscando “Ryobi Garage Door Opener Installation” (Instalación del sistema de apertura
para portón de garage Ryobi oficial) en YouTube.
  • Page 1 1

Ryobi GD201-GDM120 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues