Craftsman CMXEOCG772 Manuel utilisateur

Catégorie
Porte de garage
Taper
Manuel utilisateur

Ce manuel convient également à

Owner's Manual
SMART GARAGE DOOR OPENER
For Residential Use Only
MODELS CMXEOCG322, CMXEOCG572,
CMXEOCG772, and CMXEOCG982
READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS BEFORE FIRST USE OF THIS PRODUCT.
FASTEN THE MANUAL NEAR THE GARAGE DOOR AFTER INSTALLATION.
PERIODIC CHECKS OF THE OPENER ARE REQUIRED TO ENSURE SAFE OPERATION.
DO NOT INSTALL ON A ONE-PIECE DOOR IF USING DEVICES OR FEATURES PROVIDING UNATTENDED CLOSE.
UNATTENDED DEVICES AND FEATURES ARE TO BE USED ONLY WITH SECTIONAL DOORS. SEE PAGE 3.
WRITE DOWN THE CRAFTSMAN
®
SERIAL NUMBER LOCATED ON THE GARAGE DOOR OPENER:
WWW.CRAFTSMAN.COM
INTRODUCTION 3
Safety Symbol Review and Signal Word Review 3
Unattended Operation 3
Preparing Your Garage Door 3
Tools Needed 4
Test the Wi-Fi® Signal Strength in Your Garage 4
Planning 5
Carton Inventory 7
Hardware Inventory 8
ASSEMBLY 9
Assemble the Rail and Install the Trolley 9
Fasten the Rail to the Motor Unit 9
Install the Idler Pulley 10
Install the Belt 11
Tighten the Belt 11
Install the Sprocket Cover 12
INSTALLATION 12
Important Installation Instructions 12
Determine the Header Bracket Location 13
Install the Header Bracket 14
Attach the Rail to the Header Bracket 15
Position the Opener 16
Hang the Opener 17
Install the Lights 18
Attach the Emergency Release Rope and Handle 18
Fasten the Door Bracket 19
Connect Door Arm to Trolley 21
Attach the Warning Labels 22
Install the Door Control 23
Install The Safety Reversal System 24
Electrical Requirements 27
Aligning the Safety Reversing Sensors 27
ADJUSTMENT 28
Introduction 28
Program the Travel 29
Test the Safety Reversal System 30
Test The Safety Reversing Sensors 30
BATTERY BACKUP Model CMXEOCG982 31
Install the Battery 31
Test the Battery 31
Charge the Battery 31
Battery Status LED 31
myQ® SMARTPHONE CONTROL 32
Connect With Your Smartphone 32
OPERATION 33
Important Safety Instructions 33
Features 34
Dual-Function Control Panel Model CMXEOCG572 35
Door Control Model CMXEOCG322 35
Motion Detecting Control Panel Models CMXEOCG772 and CMXEOCG982 36
Remote Control and Wireless Keypad 37
To Erase the Memory 37
To Open the Door Manually 38
The Remote Control Battery 38
Care of Your Opener 38
TROUBLESHOOTING 39
REPAIR PARTS 40
Rail Assembly Parts 40
Installation Parts 40
Motor Unit Assembly Parts 41
ACCESSORIES 43
WARRANTY 43
AUTOMATIC GARAGE DOOR OPENER SAFETY & MAINTENANCE GUIDE 44
2
TABLE OF CONTENTS
INTRODUCTION
SAFETY SYMBOL REVIEW AND SIGNAL WORD REVIEW
This garage door opener has been designed and tested to offer safe service provided
it is installed, operated, maintained and tested in strict accordance with the
instructions and warnings contained in this manual.
Mechanical
Electrical
When you see these Safety Symbols and Signal Words on the following pages, they will
alert you to the possibility of serious injury or death if you do not comply with the
warnings that accompany them. The hazard may come from something mechanical or
from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the
possibility of damage to your garage door and/or the garage door opener if you do not
comply with the cautionary statements that accompany it. Read them carefully.
WARNING: This product can expose you to chemicals including lead, which
are known to the State of California to cause cancer or birth defects or other
reproductive harm. For more information go to www.P65Warnings.ca.gov
UNATTENDED OPERATION
The Timer-to-Close (TTC) feature and myQ
®
are examples of unattended close and are
to be used ONLY with sectional doors. Any device or feature that allows the door to
close without being in the line of sight of the door is considered unattended close.
The Timer-to-Close (TTC) feature and any myQ
®
devices are to be used ONLY with
sectional doors.
PREPARING YOUR GARAGE DOOR
To prevent possible SERIOUSINJURYor DEATH:
ALWAYS call a trained door systems technician if garage door binds, sticks, or
is out of balance. An unbalanced garage door may NOT reverse when required.
NEVER try to loosen, move or adjust garage door, door springs, cables,
pulleys, brackets or their hardware, ALLof which are under EXTREME tension.
Disable ALLlocks and remove ALLropes connected to garage door BEFORE
installation and operating garage door opener to avoid entanglement.
DO NOT install on a one-piece door if using devices or features providing
unattended close. Unattended devices and features are to be used ONLY with
sectional doors.
To prevent damage to garage door and opener:
ALWAYS disable locks BEFORE installing and operating the opener.
ONLY operate garage door opener at 120V, 60Hz to avoid malfunction and
damage.
Before you begin:
1. Disable locks and remove any ropes connected to the garage door.
2. Lift the door halfway up. Release the door. If balanced, it should stay in
place, supported entirely by its springs.
3. Raise and lower the door to check for binding or sticking. If your door binds,
sticks, or is out of balance, call a trained door systems technician.
4. Check the seal on the bottom of the door. Any gap between the floor and the
bottom of the door must not exceed 1/4" (6mm). Otherwise, the safety
reversal system may not work properly.
5. The opener should be installed above the center of the door. If there is a
torsion spring or center bearing plate in the way of the header bracket, it
may be installed within 4feet (1.2 m) to the left or right of the door center.
See page13.
Sectional Door One-Piece Door
3
TOOLS NEEDED
During assembly, installation and adjustment of the opener, instructions will call for
hand tools as illustrated below.
Drill Bits 3/16",
5/16", and 5/32"
Claw Hammer
Carpenter’s Level
(optional)
Pencil
Screwdriver
Drill
Wire Cutters
Adjustable End Wrench
Tape Measure
Pliers
Sockets and Wrench 1/2",
5/8", 7/16", 9/16", and 1/4"
Hack Saw
Stepladder
TEST THE WI-FI
®
SIGNAL STRENGTH IN YOUR GARAGE
Monitor and control your garage door from anywhere using the myQ
®
App. You will
need a router with Wi-Fi and a smartphone or other mobile device. Make sure your
mobile device is connected to your Wi-Fi network. Hold your mobile device in the
place where your garage door opener will be installed and check the Wi-Fi signal
strength.
Wi-Fi signal is weak.
The garage door opener will likely connect to
your Wi-Fi network. If not, try one of the
options below.
No Wi-Fi signal.
Try one of the following:
• Move your router closer to the garage door
opener to minimize interference from walls
and other objects
• Buy a Wi-Fi range extender
Check Signal Strength. If you see:
Wi-Fi signal is strong.
You’re all set!
Install your new garage door opener.
Visit support.chamberlaingroup.com for more details
See myQ
®
App Control page 32 to connect your garage door opener to your Wi-Fi
network. Do NOT connect prior to installation.
Wi-Fi
®
is a registered trademark of Wi-Fi Alliance
4
PLANNING
Identify the type and height of your garage door. Survey your garage area to see if any
of the conditions below apply to your installation. Additional materials may be
required. You may find it helpful to refer back to this page and the accompanying
illustrations as you proceed with the installation of your opener. Depending on your
requirements, there are several installation steps which may call for materials or
hardware not included in the carton.
Installation Step 1 Look at the wall or ceiling above the garage door. The
header bracket must be securely fastened to structural supports.
Installation Step 5 Do you have a finished ceiling in your garage? If so, a
support bracket and additional fastening hardware may be required.
Installation Step 12 Depending upon garage construction, extension
brackets or wood blocks may be needed to install sensors.
Installation Step 12 Alternate floor mounting of the safety reversing
sensor will require hardware not provided.
Do you have an access door in addition to the garage door? If not, an
emergency key release is required.
Look at the garage door where it meets the floor. Any gap between the floor
and the bottom of the door must not exceed 1/4" (6 mm). Otherwise, the
safety reversal system may not work properly. See Adjustment Step 2. Floor
or door should be repaired.
SECTIONAL DOOR INSTALLATION
Do you have a steel, aluminum, fiberglass or glass panel door? If so,
horizontal and vertical reinforcement is required (Installation Step 8).
The opener should be installed above the center of the door. If there is a
torsion spring or center bearing plate in the way of the header bracket, it
may be installed within 4 feet (1.22 m) to the left or right of the door
center. See Installation Steps 1 and 8.
If your door is more than 7 feet (2.13 m) high, see rail extension kits listed
on Accessories page.
Safety Reversing Sensor
Header Wall
Access Door
Safety
Reversing
Sensor
Gap between floor
and bottom of door
must not exceed 1/4" (6 mm).
Extension Spring
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 18 for details.
Support bracket &
fastening hardware
is required.
See page 16.
FINISHED CEILING
Rail
Wall-mounted
Door Control
OR
Torsion Spring
Vertical
Centerline
of Garage
Door
Header
Wall
Garage
Door
Header
Bracket
Straight
Door
Arm
Emergency Release
Rope & Handle
Door
Bracket
Curved
Door Arm
Garage
Door
Spring
Belt
Rail Tab
SECTIONAL DOOR INSTALLATION
CLOSED POSITION
Trolley
Motor unit
5
PLANNING (CONTINUED)
ONE-PIECE DOOR INSTALLATIONS
Generally, a one-piece door does not require reinforcement. If your door is
lightweight, refer to the information relating to sectional doors in
Installation Step 8.
Depending on your door’s construction, you may need additional mounting
hardware for the door bracket (Installation Step 8).
Without a properly installed safety reversing sensor, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
The gap between the bottom of the garage door and the floor MUST NOT
exceed 1/4" (6 mm). Otherwise, the safety reversal system may NOT work
properly.
The floor or the garage door MUST be repaired to eliminate the gap.
Safety Reversing
Sensor
Access
Door
FINISHED CEILING
Support bracket
& fastening
hardware is required.
See page 16.
Safety Reversing
Sensor
Header Wall
Gap between floor
and bottom of door must
not exceed 1/4" (6 mm).
Wall-Mounted
Door Control
Rail
Motor Unit
Header
Wall
Header
Bracket
Trolley
Straight
Door
Arm
Emergency
Release
Rope & Handle
Door Bracket
Curved
Door
Arm
Garage
Door
Rail Tab
Belt
Rail
CLOSED POSITION
Access
Door
Safety
Reversing Sensor
Safety
Reversing Sensor
Gap between floor
and bottom of door
must not exceed
1/4" (6 mm).
Garage
Door
Header
Wall
Header
Bracket
Door
Bracket
Straight
Door
Arm
Curved
Door Arm
Trolley
Emergency
Release
Rope &
Handle
Rail
Belt
Rail Tab
CLOSED POSITION
ONE-PIECE DOOR WITHOUT TRACK
ONE-PIECE DOOR WITH TRACK
6
CARTON INVENTORY
Your garage door opener is packaged in one carton which contains the motor unit and
all parts illustrated below. Accessories will depend on the model purchased. If
anything is missing, carefully check the packing material.
Hardware for assembly and installation is shown on the next page. Save the carton
and packing material until installation and adjustment is complete.
Straight Door Arm Section
(packaged inside the front rail)
Curved Door
Arm Section
Safety Labels
and Literature
2-Conductor Bell Wire
White and White/Red
Idler Pulley
(In Hardware Bag)
Motor Unit with 2 Light Lenses
Hanging Brackets
(packaged inside the front rail)
(2) Safety Reversing Sensors
(1 Sending Sensor and 1 Receiving Sensor)
with 2-Conductor White and White/Black
Bell Wire attached
Door Bracket
3-Button Remote Control
Trolley
Safety Reversing
Sensor Bracket (2)
Rail
Center/Back
Sections
“U” Bracket
Header Bracket
Hardware Bag
Wireless Keypad
Belt
Rail
Front (header)
Section
Motion-Detecting
Control Panel
Battery
For Model CMXEOCG982
For Model CMXEOCG572
For Model CMXEOCG322
LED Bulb (2)
For Model CMXEOCG982
For Models CMXEOCG772
and CMXEOCG982
For Models CMXEOCG572,
CMXEOCG772, and
CMXEOCG982
For Models CMXEOCG572,
CMXEOCG772, and
CMXEOCG982
For Models CMXEOCG572,
CMXEOCG772, and
CMXEOCG982
For Model CMXEOCG322
For Model CMXEOCG322
Sprocket cover
with screws (3)
Sprocket cover
with screws (2)
Dual-Function Control Panel
Motor Unit with 1 Light Lens
Standard Doorbell
7
HARDWARE INVENTORY
Separate all hardware and group as shown below for the assembly and installation procedures.
Idler Bolt
Nut 3/8"
Lock Washer 3/8"
Lock Nut
1/4"-20
Wing Nut
1/4"-20 (2)
Carriage Bolt
1/4"-20x1/2" (2)
Handle
Nut 5/16"-18 (4)
Ring
Fastener (3)
Insulated Staples
(Not shown)
Drywall Anchors (2)
Clevis Pin
5/16"x1"
Rope
Lock Washer 5/16" (4)
Lag Screw
5/16"-9x1-5/8" (4)
Hex Bolt
5/16"-18x7/8" (4)
Clevis Pin
5/16"x1-1/4"
Screw 6-32x1" (2)
Clevis Pin
5/16"x1-1/2"
Bolt 1/4"-20x1-3/4"
Self-Threading Screw
1/4"-14x5/8" (2)
Screw
6ABx1" (2)
Master Link
Threaded Shaft with
Spring Trolley Nut
ASSEMBLY HARDWARE
INSTALLATION HARDWARE
8
ASSEMBLY STEP 1
ASSEMBLE THE RAIL AND INSTALL THE TROLLEY
To prevent INJURY from pinching, keep hands and fingers away from the joints
while assembling the rail.
To avoid installation difficulties, do not run the garage door opener until instructed
to do so.
The front rail has a cut out window at the door end. The front rail has a rail tab.
This tab MUST be on the top of the rail when assembled.
1. Remove the straight door arm and hanging bracket packaged inside the front
rail and set aside for Installation Step 5 and 9. NOTE: To prevent INJURY
while unpacking the rail carefully remove the straight door arm stored within
the rail section.
2. Align the rail sections on a flat surface as shown and slide the tapered ends
into the larger ones. Tabs along the side will lock into place.
3. Place the motor unit on packing material to protect the cover, and rest the
back end of the rail on top. For convenience, put a support under the front
end of the rail.
4. As a temporary stop, insert a screwdriver into the hole 10" (25 cm) from the
front end of the rail, as shown.
5. Check to be sure there are 4 plastic wear pads inside the inner trolley. If
they became loose during shipping, check all packing material. Snap them
back into position as shown.
6. Slide the trolley assembly along the rail from the back end to the
screwdriver.
7. Slide the rail onto the “U” bracket, until it reaches all the stops on the top
and sides of the U” bracket.
To garage
door opener
(TO MOTOR UNIT)
“U” Bracket
SLIDE TO STOPS
ON TOP AND
SIDES OF
“U” BRACKET
Outer Trolley
Inner Trolley
Wear Pads
Front Rail
Section
(TO DOOR)
Rail
Tab
Trolley
Window
Cut-Out
Idler
Pulley
Hole
ASSEMBLY STEP 2
FASTEN THE RAIL TO THE MOTOR UNIT
To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners
mounted in the top of the opener.
1. Insert a 1/4"-20 x 1-3/4" bolt into the cover protection bolt hole on the back
end of the rail as shown. Tighten securely with a 1/4"-20 lock nut. DO NOT
overtighten.
2. Remove the bolts from the top of the motor unit.
3. Use the carton to support the front end of the rail.
4. Place the U” bracket, flat side down onto the motor unit and align the
bracket holes with the bolt holes.
5. Fasten the “U” bracket with the previously removed bolts; DO NOT use any
power tools. The use of power tools may permanently damage the garage
door opener.
“U” Bracket
Cover Protection
Bolt Hole
Bolt
Lock Nut
(Locking feature
must be placed
against the rail)
Bolts (Mounted in the garage door opener)
9
ASSEMBLY STEP 3
INSTALL THE IDLER PULLEY
1. Lay the belt beside the rail, as shown. Grasp the end with the hooked
trolley connector and pass approximately 12" (30 cm) of belt through the
window. Keep the ribbed side toward the rail, and allow it to hang until
Assembly Step 4.
2. Remove the tape from the idler pulley. The inside center should be pre-
greased. If dry, regrease to ensure proper operation.
3. Place the idler pulley into the window as shown.
4. Insert the idler bolt from the top through the rail and pulley. Tighten with a
3/8" lock washer and nut underneath the rail until the lock washer is
compressed.
5. Rotate the pulley to be sure it spins freely.
6. Locate the rail tab. The rail tab is between the idler bolt and the trolley in
the front rail section. Use a flathead screwdriver and lift the rail tab until
the tab is vertical (90º).
Idler Bolt
Rail Tab
Rail Tab
CORRECT
INCORRECT
Screwdriver
Grease inside pulley
Pulley
Trolley Connector
Lock Washer 3/8"
Nut 3/8"
Trolley
Nut 3/8"
Idler Bolt
HARDWARE SHOWN ACTUAL SIZE
Lock Washer 3/8"
10
ASSEMBLY STEP 4
INSTALL THE BELT
1. Pull the belt around the idler pulley and toward the trolley. The ribbed side
must contact the pulley.
2. Hook the trolley connector into the retaining slot on the trolley as shown
(Figure1).
3. With the trolley against the screwdriver, dispense the remainder of the belt
along the rail lengthtoward the motor unit and around the sprocket
(Figure2). The sprocket teeth must engage the belt.
4. Check to make sure the belt is not twisted. Connect the trolley threaded
shaft with the master link(Figure3).
Push pins of master link bar through holes in end of belt and trolley
threaded shaft.
Push master link cap over pins and past pin notches.
Slide clip-on spring over cap and onto pin notches until both pins are
securely locked in place.
5. Remove the spring trolley nut from the threaded shaft.
6. Insert the trolley threaded shaft through the hole in the trolley.
Master Link
Figure 3
Threaded Shaft with Spring Trolley Nut
Threaded Shaft
Master Link
Sprocket
Figure 2
Figure 1
Trolley
Connector
Retaining
Slot
ASSEMBLY STEP 5
TIGHTEN THE BELT
1. By hand, thread the spring trolley nut on the threaded shaft until it is finger
tight against the trolley. Do not use any tools. Remove the screwdriver.
2. Insert a flathead screwdriver tip into one of the nut ring slots and brace it
firmly against the trolley.
3. Tighten the spring trolley nut with an adjustable wrench or a 7/16" open end
wrench about a quarter turn until the spring releases and snaps the nut ring
against the trolley. This sets the spring to optimum belt tension.
Nut Ring
BEFORE
1"
(2.5
cm)
Nut Ring
AFTER
1-1/4"
(3.18 cm)
Spring
Trolley Nut
Nut Ring Slot
Spring Trolley
11
ASSEMBLY STEP 6
INSTALL THE SPROCKET COVER
To avoid possible SERIOUS INJURY to finger from moving garage door opener:
ALWAYS keep hand clear of sprocket while operating opener.
Securely attach sprocket cover BEFORE operating.
1. Position the sprocket cover over the sprocket as shown and fasten to
the mounting plate with #8x3/8" hex screws provided.
Hex Screws
Sprocket Cover
Hex Screws
Sprocket Cover
OR
You have now finished assembling your garage door opener. Please read the following
warnings before proceeding to the installation section.
INSTALLATION
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and lubricated garage
door. An improperly balanced door may NOT reverse when required and could
result in SEVERE INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware MUST be made by
a trained door systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE
installing opener to avoid entanglement.
5. Where possible, install the door opener 7 feet (2.13 m) or more above the floor.
6. Mount the emergency release within reach, but at least 6 feet (1.83 m) above
the floor and avoiding contact with vehicles to avoid accidental release.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVER wear watches, rings or loose clothing while installing or servicing
opener. They could be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
within sight of the garage door.
out of reach of small children at a minimum height of 5feet (1.5m)
above floors, landings, steps or any other adjacent walking surface.
away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to garage door control in a
prominent location.
11. Place emergency release/safety reverse test label in plain view on inside of
garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse
on contact with a 1-1/2" (3.8cm) high object (or a 2x4 laid flat) on the floor.
13. DO NOT install on a one-piece door if using devices or features providing
unattended close. Unattended devices and features are to be used ONLY with
sectional doors.
12
INSTALLATION STEP 1
DETERMINE THE HEADER BRACKET LOCATION
To prevent possible SERIOUS INJURY or DEATH:
Header bracket MUST be RIGIDLY fastened to structural support on header
wall or ceiling, otherwise garage door might NOT reverse when required. DO
NOT install header bracket over drywall.
Concrete anchors MUST be used if mounting header bracket or 2x4 into
masonry.
NEVER try to loosen, move or adjust garage door, springs, cables, pulleys,
brackets, or their hardware, ALL of which are under EXTREME tension.
ALWAYS call a trained door systems technician if garage door binds, sticks,
or is out of balance. An unbalanced garage door might NOT reverse when
required.
Installation procedures vary according to garage door types. Follow the instructions
which apply to your door.
1. Close the door and mark the inside vertical centerline of the garage door.
2. Extend the line onto the header wall above the door. You can fasten the
header bracket within 4 feet (1.22 m) of the left or right of the door center
only if a torsion spring or center bearing plate is in the way; or you can
attach it to the ceiling (see page 14) when clearance is minimal. (It may be
mounted on the wall upside down if necessary, to gain approximately 1/2"
(1 cm). If you need to install the header bracket on a 2x4 (on wall or ceiling),
use lag screws (not provided) to securely fasten the 2x4 to structural
supports as shown here and on page 14.
3. Open your door to the highest point of travel as shown. Draw an intersecting
horizontal line on the header wall above the high point:
2" (5 cm) above the high point for sectional door and one-piece door with
track.
8" (20 cm) above the high point for one-piece door without track.
This height will provide travel clearance for the top edge of the door.
NOTE: If the total number of inches exceeds the height available in your garage, use
the maximum height possible, or refer to page14 for ceiling installation.
Header Wall
Vertical Centerline
of Garage Door
Level
(optional)
2x4
2x4
Structural
Supports
Unfinished
Ceiling
OPTIONAL
CEILING
MOUNT
FOR
HEADER
BRACKET
Door
Jamb
Hardware
Header Wall
Highest Point
of Travel
Door
2" (5 cm)
Door
Track
Header Wall
Highest Point
of Travel
2" (5 cm)
8" (20 cm)
Highest
Point
of Travel
Door
Pivot
8" (20 cm)
Highest
Point
of Travel
Header Wall
Header Wall
Track
One-piece door with horizontal track
One-piece door without track:
jamb hardware
One-piece door without track:
pivot hardware
Sectional door with curved track
13
INSTALLATION STEP 2
INSTALL THE HEADER BRACKET
You can attach the header bracket either to the wall above the garage door, or to the
ceiling. Follow the instructions which will work best for your particular requirements.
Do not install the header bracket over drywall. If installing into masonry, use
concrete anchors (not provided).
WALL HEADER BRACKET INSTALLATION
1. Center the bracket on the vertical centerline with the bottom edge of the
bracket on the horizontal line as shown (with the arrow pointing toward the
ceiling).
2. Mark the vertical set of bracket holes. Drill 3/16" pilot holes and fasten the
bracket securely to a structural support with the hardware provided.
Lag Screws
5/16"-9x1-5/8"
Highest Point of
Garage Door Travel
Vertical
Centerline
of Garage Door
Door Spring
2x4
Structural
Support
Vertical
Centerline
of Garage Door
Header
Bracket
Horizontal
Line
UP
Wall Mount
Optional
Mounting Holes
Figure 1
Header Wall
Garage Door
CEILING HEADER BRACKET INSTALLATION
1. Extend the vertical centerline onto the ceiling as shown.
2. Center the bracket on the vertical mark, no more than 6" (15cm) from the
wall. Make sure the arrow is pointing away from the wall. The bracket can
be mounted flush against the ceiling when clearance is minimal.
3. Mark the side holes. Drill 3/16" pilot holes and fasten bracket securely to a
structural support with the hardware provided.
Lag Screws
5/16"-9x1-5/8"
Door
Spring
6" (15 cm) Maximum
Header
Bracket
Vertical
Centerline
of Garage Door
Garage Door
Vertical Centerline
of Garage Door
UP
Ceiling Mounting Holes
Figure 2
Header Wall
Finished Ceiling
Lag Screw
5/16"-9x1-5/8"
HARDWARE SHOWN ACTUAL SIZE
14
INSTALLATION STEP 3
ATTACH THE RAIL TO THE HEADER BRACKET
1. Position the opener on the garage floor below the header bracket. Use
packing material as a protective base.
NOTE: If the door spring is in the way, you will need help. Have someone
hold the opener securely on a temporary support to allow the rail to clear
the spring.
2. Position the rail bracket against the header bracket.
3. Align the bracket holes and join with a clevis pin as shown.
4. Insert a ring fastener to secure.
Clevis Pin
Ring Fastener
HARDWARE SHOWN ACTUAL SIZE
Clevis Pin 5/16"x1-1/2" Ring Fastener
15
INSTALLATION STEP 4
POSITION THE OPENER
Follow instructions which apply to your door type as illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK
A 2x4 laid flat is convenient for setting an ideal door-to-rail distance.
1. Raise the opener onto a stepladder. You will need help at this point if the
ladder is not tall enough.
2. Open the door all the way and place a 2x4 laid flat on the top section
beneath the rail (Figure 1).
3. If the top section or panel hits the trolley when you raise the door, pull down
on the trolley release arm to disconnect inner and outer sections. Slide the
outer trolley toward the motor unit. The trolley can remain disconnected until
Installation Step 12 is completed.
ENGAGED
RELEASED
Trolley
Release Arm
ONE-PIECE DOOR WITHOUT TRACK
A 2x4 on its side is convenient for setting an ideal door-to-rail distance.
1. Raise the opener onto a stepladder. You will need help at this point if the
ladder is not tall enough.
2. Open the door all the way and place a 2x4 on its side on the top section of
the door beneath the rail (Figure 2).
3. The top of the door should be level with the top of the motor unit. Do not
position the opener more than 4" (10 cm) above this point.
To prevent damage to garage door, rest garage door opener rail on 2x4 placed on
top section of door.
2x4 is used to
determine the correct
mounting height
from ceiling.
Door
Header Bracket
Top of Door
2x4 is used to
determine the correct
mounting height
from ceiling.
Rail
Figure 1
Figure 2
16
INSTALLATION STEP 5
HANG THE OPENER
To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it
SECURELY to structural supports of the garage. Concrete anchors MUST be used
if installing ANY brackets into masonry.
Three representative installations are shown. Yours may be different. Hanging
brackets should be angled (Figure 1) to provide rigid support. On finished ceilings
(Figures 2 and 3), attach a sturdy metal bracket to structural supports before
installing the opener. This bracket and fastening hardware are not provided.
1. Measure the distance from each side of the motor unit to the structural
support.
2. Cut both pieces of the hanging bracket to required lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with 5/16"-9x1-5/8" lag screws.
5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts,
lock washers and nuts.
6. Check to make sure the rail is centered over the door (or in line with the
header bracket if the bracket is not centered above the door).
7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise
the header bracket.
NOTE: DO NOT connect power to opener at this time.
Measure
Distance
Lag Screws
5/16"-9x1-5/8"
Structural
Supports
Hex Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Bracket
(Not Provided)
Lag Screws
5/16"-9x1-5/8"
(Not Provided)
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Hidden
Support
Hex Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Hex Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Lag Screws
5/16"-9x1-5/8"
(Not Provided)
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Figure 1
Figure 2
Figure 3
FINISHED CEILING
FINISHED CEILING
Lag Screw 5/16"-9x1-5/8"
Hex Bolt
5/16"-18x7/8"
Nut 5/16"-18
Lock Washer 5/16"
HARDWARE SHOWN ACTUAL SIZE
17
INSTALLATION STEP 6
INSTALL THE LIGHTS
To prevent possible OVERHEATING of the end panel or light socket:
Use ONLY A19 light bulbs.
DO NOT use incandescent bulbs larger than 100W.
DO NOT use compact fluorescent light bulbs larger than 26W (100W
equivalent).
DO NOT use halogen bulbs.
DO NOT use short neck or specialty light bulbs.
LED bulbs may cause remote control radio interference. Visit craftsman.com for
a list of recommended LED bulbs.
1. Pull light lens down.
2. Insert light bulb.
3. Close light lens.
or
or
or
OR
INSTALLATION STEP 7
ATTACH THE EMERGENCY RELEASE ROPE AND HANDLE
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
If possible, use emergency release handle to disengage trolley ONLY when
garage door is CLOSED. Weak or broken springs or unbalanced door could
result in an open door falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage doorway is clear of
persons and obstructions.
NEVER use handle to pull door open or closed. If rope knot becomes untied,
you could fall.
1. Insert one end of the emergency release rope through the handle. Make sure
that NOTICE” is right side up. Secure with an overhand knot at least 1" (2.5
cm) from the end of the rope to prevent slipping.
2. Insert the other end of the emergency release rope through the hole in the
trolley release arm. Mount the emergency release within reach, but at least 6
feet (1.83m) above floor, avoiding contact with vehicles to prevent
accidental release and secure with an overhand knot.
NOTE: If it is necessary to cut the emergency release rope, seal the cut end with a
match or lighter to prevent unraveling. Ensure the emergency release rope and handle
are above the top of all vehicles to avoid entanglement.
Trolley
Release Arm
Emergency
Release Handle
Overhand
Knot
Trolley
18
INSTALLATION STEP 8
FASTEN THE DOOR BRACKET
Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE
reinforcement BEFORE installation of door bracket. Contact the garage door
manufacturer or installing dealer for opener reinforcement instructions or
reinforcement kit.
Follow instructions which apply to your door type as illustrated below or on the
following page.
A horizontal reinforcement brace should be long enough to be secured to two or
three vertical supports. A vertical reinforcement brace should cover the height of
the top panel.
Figure 1 shows one piece of angle iron as the horizontal brace. For the vertical
brace, 2 pieces of angle iron are used to create a U-shaped support. The best
solution is to check with your garage door manufacturer for an opener installation
door reinforcement kit.
NOTE: Many door reinforcement kits provide for direct attachment of the clevis pin
and door arm. In this case you will not need the door bracket; proceed to Step 9.
SECTIONAL DOORS
1. Center the door bracket on the previously marked vertical centerline used
for the header bracket installation. Note correct UP placement, as stamped
inside the bracket.
2. Position the top edge of the bracket 2"-4" (5-10cm) below the top edge of
the door, OR directly below any structural support across the top of the
door.
3. Mark, drill holes and install as follows, depending on your door’s
construction.
Metal or light weight doors using a vertical angle iron brace between the door panel
support and the door bracket:
Drill 3/16" fastening holes. Secure the door bracket using the two 1/4"-
14x5/8" self-threading screws. (Figure2A)
Alternately, use two 5/16"-18x2" bolts, lock washers and nuts (not
provided). (Figure2B)
Metal, insulated or light weight factory reinforced doors:
Drill 3/16" fastening holes. Secure the door bracket using the self-threading
screws. (Figure3)
Wood doors:
Use top and bottom or side to side door bracket holes. Drill 5/16" holes
through the door and secure bracket with 5/16"-18x2" carriage bolts, lock
washers and nuts (not provided). (Figure4)
NOTE: The 1/4"-14x5/8" self-threading screws are not intended for use on wood
doors.
Figure 1
Door Bracket
Vertical Centerline
of Garage Door
Vertical Reinforcement
Self-Threading
Screw 1/4"-14x5/8"
UP
Figure 2A
Figure 2B
Bolt
(Not
Door
Bracket
Vertical Reinforcement
5/16"-18x2"
(Not
Provided)
Nut
5/16"-18
Lock Washer 5/16"
UP
Vertical
Centerline
of Garage Door
UP
Self-Threading Screw
1/4"-14x5/8"
Vertical
Centerline
of Garage Door
UP
Inside Edge
of Door or
Reinforcement Board
Bolt 5/16"-18x2"
(Not Provided)
Vertical
Centerline
of Garage
Door
Figure 3
Figure 4
Vertical
Centerline
of Garage
Door
Door
Bracket
Location
Header
Bracket
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED FOR
LIGHTWEIGHT GARAGE DOORS
(FIBERGLASS, ALUMINUM, STEEL,
DOORS WITH GLASS PANEL, ETC.).
(NOT PROVIDED)
Self-Threading
Screw
1/4"-14x5/8"
HARDWARE
SHOWN ACTUAL
SIZE
19
FASTEN THE DOOR BRACKET (CONTINUED)
ONE-PIECE DOORS
Please read and comply with the warnings and reinforcement instructions on the
previous page. They apply to one-piece doors also.
Center the door bracket on the top of the door, in line with the header
bracket as shown. Mark either the left and right, or the top and bottom
holes.
Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-
14x5/8" self-threading screws provided.
Wood Doors: Drill 5/16" holes and use 5/16"x2" carriage bolts, lock
washers and nuts (not provided) or 5/16"x1-1/2" lag screws (not provided)
depending on your installation needs.
NOTE: The door bracket may be installed on the top edge of the door if required for
your installation. (Refer to the dotted line optional placement drawing.)
Header Wall
Vertical
Centerline of
Garage Door
Optional
Placement
of Door
Bracket
Header
Bracket
Door
Bracket
2x4
Support
For a door with no exposed framing,
or for the optional installation, use
lag screws 5/16"x1-1/2" (Not Provided)
to fasten door bracket.
Top of Door
(Inside Garage)
Door
Bracket
Optional
Placement
Top Edge
of Door
Self-Threading
Screw
1/4"-14x5/8"
Door
Bracket
Top of Door
(Inside Garage)
Carriage Bolt
5/16"x2"
(Not Provided)
Optional
Placement
Lock
Washer
5/16"
Nut
5/16"-18
Top Edge
of Door
METAL DOOR
WOOD DOOR
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED
FOR LIGHTWEIGHT GARAGE
DOORS (FIBERGLASS, ALUMINUM,
STEEL, DOORS WITH GLASS
PANEL, ETC.). (NOT PROVIDED)
Finished Ceiling
Self-Threading Screw
1/4"-14x5/8"
HARDWARE SHOWN
ACTUAL SIZE
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Craftsman CMXEOCG772 Manuel utilisateur

Catégorie
Porte de garage
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues