ELICA EPL630S1 Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire

Ce manuel convient également à

Use, Care, and Installation Guide
Guide d’utilisation, d’entretien et d’installation
Guía de instalación, uso y mantenimiento
READ AND SAVE THESE INSTRUCTIONS
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
LEA Y GUARDE ESTAS INSTRUCCIONES
Printed in Mexico
2
EN
FR
ES
Contents
Sommaire
Contenido
page
page
página
2
15
27
English
Contents
Important safety Notice........................................................................................................................................ 3
Electrical & Installation requirements ...............................................................................................................
4
Electrical requirements ................................................................................................................................................................................. 4
Before installing the hood .............................................................................................................................................................................
4
List of Materials.................................................................................................................................................... 5
Parts supplied ............................................................................................................................................................................................... 5
Parts not supplied ......................................................................................................................................................................................... 5
Dimensions and Clearances............................................................................................................................... 5
Duct Options and Examples................................................................................................................................ 6
Installing Preparation...........................................................................................................................................
6
Mounting the duct cover bracket.................................................................................................................................................................... 7
Ceiling / wall ducting .....................................................................................................................................................................................
7
Installation ............................................................................................................................................................8
Mounting the hood ........................................................................................................................................................................................ 8
Electrical Connection................................................................................................................................................................................... 9
Description of the hood & Controls................................................................................................................... 10
Controls.......................................................................................................................................................................................................... 10
Maintenance ......................................................................................................................................................... 11
Available Accesories............................................................................................................................................ 12
Warranty ............................................................................................................................................................... 13
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
3
READ AND SAVE THESE INSTRUCTIONS
Important safety Notice
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
OR VAPOURS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and lock service panel disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
Installation work and electrical wiring must be done by
qualiedperson(s)inaccordancewithallapplicable
codes&standards,includingre-ratedconstruction.
Sufcientairisneededforpropercombustionand
exhaustingofgasesthroughtheue(Chimney)offuel
burningequipmenttopreventback-drafting.Followthe
heating equipment manufacturers guideline and safety
standardssuchasthosepublishedbytheNationalFire
ProtectionAssociation(NFPA),theAmericanSocietyfor
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE),andthelocalcodeauthorities.
When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
Ducted systems must always be vented to the outdoors.
CAUTION
To reduce risk of re and to properly exhaust air, be sure
to duct air outside - do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT
WORK.
Installthishoodinaccordancewithallrequirementsspecied.
WARNING
To reduce the risk of re or electric shock, do not use this
hood with any external solid state speed control device.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
ambeingfood(I.e.CrepesSuzette,CherriesJubilee,
PeppercornBeefFlambe’).
Clean ventilating fans frequently. Grease should not be
allowedtoaccumulateonfanorlter.
Useproperpansize.Alwaysusecookwareappropriate
forthesizeofthesurfaceelement.
A.
B.
C.
D.
E.
F.
a)
b)
c)
d)
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a
SMOTHERFLAMESwithaclose-ttinglid,cookiesheet,
or other metal tray, then turn off the gas burner or the
electricelement.BECAREFULTOPREVENTBURNS.
Iftheamesdonotgooutimmediately,EVACUATEAND
CALLTHEFIREDEPARTMENT.
NEVERPICKUPAFLAMINGPAN-youmaybeburned.
DO NOT USE WATER, including wet dishcloths or
towels-aviolentsteamexplosionwillresult.
Use an extinguisher ONLY if:
You know you have a class ABC extinguisher, and you
already know how to operate it.
Thereissmallandcontainedintheareawhereitstarted.
Theredepartmentisbeingcalled.
Youcanghttherewithyourbacktoanexit.
a
Basedon“KitchenFireSafetyTips”publishedbyNFPA.
OPERATION
a.Alwaysleavesafetygrillsandltersinplace.Withoutthese
components,operatingblowerscouldcatchontohair,ngers
and loose clothing.
The manufacturer declines all responsibility in the event of
failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer
further declines all responsibility for injury due to negligence
and the warranty of the unit automatically expires due to
improper maintenance.
CAUTION
Automatically operated device - to reduce the risk of
injury disconnect from power supply before servicing.
a)
b)
c)
d)
1)
2)
3)
4)
4
Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
Itisthecustomer’sresponsibility:
Tocontactaqualiedelectricalinstaller.
To assure that the electrical installation is adequate and in
conformancewithNationalElectricalCode,ANSI/NFPA70
—latestedition*,orCSAStandardsC22.1-94,Canadian
ElectricalCode,Part1andC22.2No.0-M91-latestedition**
and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommendedthataqualiedelectriciandeterminethatthe
ground path is adequate.
Do not ground to a gas pipe.
Checkwithaqualiedelectricianifyouarenotsurerange
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
SaveInstallationInstructionsforelectricalinspector’suse.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect(Orcircuitbreaker)boxthroughmetalelectrical
conduit.
WiresizesmustconformtotherequirementsoftheNational
ElectricalCodeANSI/NFPA70—latestedition*,orCSA
StandardsC22.1-94,CanadianElectricalCodePart1and
C22.2No.0-M91-latestedition**andalllocalcodesand
ordinances.
AU.L.-orC.S.A.-listedconduitconnectormustbeprovided
ateachendofthepowersupplyconduit(attherangehood
andatthejunctionbox).
Copies of the standards listed may be obtained from:
*NationalFireProtectionAssociationBatterymarchParkQuincy,
Massachusetts 02269
**CSAInternational8501EastPleasantValleyRoadCleveland,
Ohio44131-5575
Before installing the hood
Forthemostefcientairowexhaust,useastraightrun
or as few elbows as possible.
CAUTION:Ventunittooutsideofbuilding,only.
At least two people are necessary for installation.
Fittingsmaterialisprovidedtosecurethehoodtomost
typesofwalls/ceilings,consultaQualiedInstaller,check
iftheyperfectlytwithyourcabinet/wall.
Donotuseexducting.
COLD WEATHER installations should have an additional
backdraftdamperinstalledtominimizebackwardcoldair
owandanonmetallicthermalbreaktominimize
conduction of outside temperatures as part of the
ductwork. The damper should be on the cold air side of
the thermal break.
The break should be as close as possible to where the
ducting enters the heated portion of the house.
Make up air: Local building codes may require the use of
Make-UpAirSystemswhenusingDuctedVentilation
SystemsgreaterthanspeciedCFMofairmovement.
ThespeciedCFMvariesfromlocaletolocale.Consult
yourHVACprofessionalforspecicrequirementsinyour
area.
Removing the packaging
CAUTION!
Remove carton carefully, wear gloves to protect against sharp
edges.
WARNING!
Removetheprotectivelmcoveringtheproductbeforeputting
into operation.
1.
2.
3.
4.
5.
6.
5
List of Materials
Parts supplied
Removing the packaging
CAUTION!
Remove carton carefully, wear gloves to protect against sharp
edges.
WARNING!
Removetheprotectivelmcoveringtheproductbeforeputting
into operation.
Hood canopy assembly with blower, transition.
2 Halogen lamps.
2Greaselters.
Duct cover.
Hardware bag with:
Template.
Ductcoversupportbracket(1piece)
Use, care and installation guide
Woodscrews(6pieces-5x45)
Assembly screws
-2(2.9x6.5)
-2(3.5x9.5)
Hood attachment anchors screws
-2(8x40)
-4(10x50)
Parts not supplied
Optional Accessories
Ductless Recirculating Kit
TobeusedonlyintheDuctless(Recirculating)version
includes:2charcoalltersanddeector
Professional Stainless Steel Grease lter
Tools/Materials required
Wire nuts
Tape to mount template
6”roundedmetalductlengthtosuitinstallation
Measuring tape
Pliers
Gloves
Knife
Safety glasses
Electricdrillwith5/16”and3/8”Bits
Strain relief
Spirit level
Duct tape
Screwdrivers:
Phillips(Posidrive)#2
Torx#2
Wire cutter/stripper
Masking tape
Hammer
Saw, jig saw or reciprocating saw
Dimensions and Clearances
*Ductless(Recirculating)versionOnly
**Ducting version Only
30” (76.2cm)
36” (91.2 cm
1½”
(4 cm)
24
1
/
8
(61 cm)
10”
(25.4 cm)
7¼” (18.4 cm
*28
7
/
8
” (73.3 cm) min
*42
1
/
16
” (106.9 cm) max
**28
3
/
8
” (72 cm) min
**38” (96.6 cm) max
6”
8
1
/
8
” (20.7 cm
21½” (54.7 cm)
6
Ducting Options and Examples
Closely follow the instructions set out in this manual.
Allresponsibility,foranyeventualinconveniences,damagesorrescausedbynotcomplyingwiththeinstructionsinthismanual,is
declined.
Venting methods
ThehoodisequippedwithatransitionBfordischargeoffumestotheoutside(Ductingversion).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless
(Recirculating)version.AttachacharcoallterandthedeectorFontheductcoversupportbracketG.Fumesandvapours
are recycled through the top grille H by means of a duct connected to the transition B and the transition mounted on the
deectorF.
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 6” Round Pipe.
Roof pitch w/
Flashing and cap
Transition (B)
Pipe
sidewall cap
with gravity
damper
Vertical Discharge Recirculating
Pipe
Pipe
Transition (B)
Transition (B)
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.
Fittingsmaterialisprovidedtosecurethehoodtomosttypesofwalls/ceilings.
However,aqualiedtechnicianmustverifysuitabilityofthematerialsinaccordancewiththetypeofwall/ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
CAUTION:
FOR GAS RANGES INSTALLATION: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30” (76,2 CM)
ABOVE THE COOKING SURFACE.
HOUSEHOLD USE. PLEASE, READ INSTALLATION MANUAL FOR SPECIFIC APPLICATION.
Check your ceiling height and the hood height maximum before you select your hood.
7
Mounting the duct cover bracket
Option A - Fixed heigh duct cover
From the horizontal line traced in the previous section,
trace a horizontal parallel line as shown below.
Center the bracket in the top horizontal line and align it
with the centerline, as described in the followinG
drawing.
Mark screw holes locations in the wall.
IMPORTANT. Check to be sure that holes locations are
leveled, and correctly centered by the vertical centerline.
Drill 5/16” pilot holes in the marked locations.
Install wall fastener anchors.
Drive wood screws, by hand, into the fasteners to allow an-
chors to expand. Remove screws.
Secure the bracket to the wall with wood screws and/or
fasteners.
Option B - Telescopic duct cover
The duct bracket should be installed against the back wall
and flush with the ceiling. This bracket will hold the
duct cover in place at the top (this a extra accessory available
not included with the hood).
Secure the bracket to the wall:
Align the marked centerline on the bracket with the
centerline on the wall.
Mark 2 screw hole locations in the wall.
Drill 5/16” pilot holes in the marked locations.
Install wall fastener anchors.
Drive wood screws, by hand, into the fastener to allow
anchors to expand. Remove the screws.
Secure the bracket to the wall with wood screws and/or
fasteners.
Ceiling ducting
If the duct will vent straight up to the ceiling:
Use level to draw a line straight up, from the centerline on
the template to the ceiling.
Measure at least 4 -12/16 ” from the back wall to the circle
center of an 6-½” hole on the ceiling.
Wall ducting
If ductwork will vent to rear:
Use a level to draw a line straight up from the centerline
on the template.
Measure at least 23 - 12/16” (the measure might vary
dependig on the elbow used) above the pencil line that]
indicates the bottom installation height, to the circle center
of an 6-½” diameter duct hole (Hole may be elongated for
duct elbow).
House wiring location
Centerline
Bracket line
27
28
/32
Horizontal straight pencil marked line
Desired installation height
Vertical
Centerline
C
e
i
l
i
n
g
Wall
For ceiling vent ducting4
12
/16” circle center
to wall
Ceiling
6½” diameter hole
FOR WALL VENT DUCT
Circle center at
23
12
/16” above the
marked bottom
pencil line
Horizontal straight
pencil line
The junction box is located on the top left side of the hood.
Wiring should enter the back wall at least 20” above the
bottom of the installation height, and within 3
5
/16
of the left side of the centerline.
8
Install framing for hood support
If drywall is present, mark the screw hole locations.
Remove the template.
Cut away enough drywall to expose 2 vertical studs at the
holes location indicated by the template.
Installtwohorizontalsupportsatleast4”X2”between
two wall studs at the bottom and upper mounting holes
installation location.
Thehorizontalsupportmustbeushwiththeroomsideof
the studs.
Use cleats behind both sides of the support to secure to
wall studs.
Reinstalldrywallandrenish.
IMPORTANT- Framing must be capable of supporting 100
lbs.
Centerline of
Installation
Space
ViewFrom
Cleats
1”x6”Min.
Mounting
Support
Rear
Mounting the hood
WARNING:
2 people are required to lift and position the hood onto the
mounting screws.
Placethetemplateonthewallalongthehorizontalline,
make sure the template is leveled and centered with the
centerline.
Mark“upper”screwholeslocationsinthewall.
IMPORTANT. Check to be sure that hole locations are
leveled and correctly centered by the vertical centerline.
Drive“upper”woodscrewsbyhand.Leave¼“of
distance between the screw head and the wall.
Removethegreaselterandmountthehoodonto
the“upper”screws.
C
Mark“lower”woodscrewholeslocationsinthewallusing
a pencil.
Remove the hood.
Drive“lower”woodscrews,byhand.Removescrews.
Mountthehoodontothe“upper”screws.
Driveandtightenthe“upper”woodscrews,byhand.
Driveandtightenthe“lower”woodscrews,byhand.
Connecting the ductwork
Install ductwork, making connections in the direction of
airowasillustrated.
Push duct over the exhaust outlet.
Wrapallductjointsandtheangeconnectionswithduct
tape for an airtight seal.
Make the same connection in the wall or ceiling vent exit.
Duct tape
over seam
6½”min.openingforductwork
9
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THISAPPLIANCEISFITTEDWITHANELECTRICAL
JUNCTIONBOXWITH3WIRES,ONEOFWHICH
(GREEN/YELLOW)SERVESTOGROUNDTHE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC
SHOCK,THEGREENANDYELLOWWIREMUSTBE
CONNECTED TO THE GROUNDING WIRE IN YOUR HOME
ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIR-
CUMSTANCESBECUTORREMOVED.
Failure to do so can result in death or electrical shock.
Disconnect power.
Remove terminal box cover.
Remove the knockout in the terminal box and install a UL
listedorCSAapproved½”strainrelief.
Runhomepowersupplywiringthrough½”strainrelief
into terminal box.
Use UL listed wire connectors and connect white wires
(B)together.
Use UL listed wire connectors and connect black wires
(C)together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
1.
2.
3.
4.
5.
6.
Connectgreen(orbare)groundwirefromhomepower
supplytothe2yellow-greengroundwires(D)interminal
box using UL listed wire connectors.
Tighten strain relief screw.
Install terminal box cover.
Reconnect power.
Mounting the duct cover
Note: Upper Duct Cover may be placed upside down to
hide (or unhide) louver holes.
Position the duct cover over the mounted hood.
Slide the bottom of the duct into the canopy area.
Position the top of the duct over the duct mounting
bracket. If a telescopic duct cover is used, grab the upper
part of the telescopic duct cover, pull it and place it in the
duct cover mounting bracket.
Secure the top of the duct with 2 assembly screws
provided.
Installthegreaselterandturnpoweronatservicepanel.
Check operation of the hood.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wiring is correct.
CheckthattheinternalGeneralON/OFFPushbutton
Switch is switched ON.
To get the most efcient use from your new range hood,
read the “Use and Care Information” section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.
7.
8.
9.
10.
A
B
C
D
E
A. UL listed wire connectors
B.White wires
C. Black wires
D.Green(orbare)wireconnectedto
yellow-greenwires
E. Home power supply
10
Description of the hood &
Controls
6
2
5
4
4
3
1
Blower and light controls
Lamp housings
GreaselterHandle
Greaselter
Duct covers
Louverholes(OnlyforRecirculatingversion)
1.
2.
3.
4.
5.
6.
Controls
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Note: Hood retains last speed setting when aspiration switch
is turned off.
Description of control panel
1. Light Button
Press lamp button to turn ON the light on High Intensity
(LampstatepreviouslyOFF).
Press lamp button to turn ON the light on Low Intensity
(LampstatepreviouslyON).
PresslampbuttontoturnOFFthelight(Lampstate
previouslyON).
2. Timer Button
The default timer setting is 10 minutes, and it can be
adjusted between 60 minutes and 1 minute.
After pressing the timer button, the control enters to a
timer setup mode, and user can adjust the timer
countdowntimewiththe“+”and“-”buttonswithin5
seconds. The timer can be initiated immediately
pressing the timer button, after setting the timer
durationorpressingthetimerbuttontwice(default10
minutessetting).
If no action occurs within 5 seconds, the countdown
will start.
Duringthetimersetupthe“+”and“-”buttonsare
dedicated to the timer and no motor action will occur.
Once the timer is initiated, it can be cancelled by
pressing the timer button again.
3. Display
Shows the hood settings.
The display will be lit at low intensity when the hood is
not operating.
Pressing any key the display will light up at high intensity.
The display will be lit at high intensity when the hood is
operating.
If no key is pressed within a minute the display will return
to being lit at low intensity.
4. “-” Button. Speed Decrease / OFF
This button is used to decrease the fan speed, or turn
OFFthefan.
ThefanwillturnOFFifthe“-”buttonispressedandthe
hoodwasintherstspeed.
Ifthefanisatsecondspeedandthe“-”buttonispressed,
thefanwillbesettorstspeed.
Ifthefanisatthirdspeedandthe“-”keyispressed,
the fan will be set to second speed.
Ifthefanisatfourthspeedandthe“-”buttonispressed,
the fan will be set to third speed.
IfthefanisOFFandthe“-”buttonispressed,thecontrol
backlight will light up.
5. “+” Button. Speed Increase / ON
This button is used to increase the fan speed, or turn
ON the fan.
11
ThefanwillturnONifthe“+”buttonispressedandthe
hoodwasOFF.
Ifthefanisatrstspeedandthe“+”buttonispressed,
the fan will be set to second speed.
Ifthefanisatsecondspeedandthe“+”buttonispressed,
the fan will be set to third speed.
Ifthefanisatthirdspeedandthe“+”buttonispressed,
the fan will be set to fourth speed.
Ifthefanisatfourthspeedandthe“+”buttonispressed,
a beep will sound.
Clock programming
The clock can be reprogrammed at any time except during
an active timed function.
The clock can be displayed in a twelve hour format and
valid clock times are from 1:00 to 12:59.
Theclockcanbereprogrammedpressingthe“Timer”
button for 3 seconds, and after, the clock can be adjusted
withthe“+”and“-”buttons.
The user can have minute increments / decrements of 1
minute,butiftheuserkeeppressingthe“+”/”-”buttons
for more than 1 second, the increments / decrements will
be of 5 minutes.
During this option the control will round to the nearest 5
minutes.
Theusercannishonreprogrammingtheclockpressing
the“Timer”button.
After 1 minute of no button pressed the control will accept the
programmed clock time and will add one minute to the set clock.
Grease lter saturation alarm (Optional)
After thirty fan functional hours, the display will show
“GreaseFilter”ifthefanisactive.
Whenthisiconisshowninthedisplay,thegreaselters
installed are required to be washed.
Toresetthegreaseltersaturationalarmtheusermust
pressthe“+”buttonfor5seconds,afterthisactionthe
icon“Greaselter”isnotdisplayed,andthehoodhasthe
normal display operation.
Charcoal lter saturation alarm (Optional)
After one hundred and twenty functional hours of the fan,
thedisplaywillshow“CharcoalFilter”ifthefanisactive.
Whenthisiconashesondisplay,thecharcoallters
installed are required to be replaced or reactivated.
Toresetthecharcoalltersaturationindicationtheuser
mustpressthe“-”buttonfor5seconds,afterthistimethe
icon“Charcoallter”isnotdisplayedandthehoodhas
the normal display operation.
Audible signal activation and deactivation
The audible signals can be activated or deactivated
pressingthe“Light”buttonfor5seconds.
If the audible signal is activated, a tone must sound and
the“Snd”symbolmustappearonthedisplayfor3seconds.
Iftheaudiblesignalisdeactivated,the“Snd”symbolmust
appear on the display for 3 seconds and no tone must
sound.
Charcoal lter inclusion and exclusion (Recirculating
accessories)
Thecharcoallterinclusionorexclusioncanbesetby
pressingthe“+”and“-”buttonsatthesametimefor5
seconds.
TheInclusionorexclusionofcharcoalltermustbe
selectedwhilethelampsandthemotorareOFF.
Whenthecharcoallterhasbeenexcluded,thecharcoal
lteralarmisdisabled.
Heat sensor
The control is equipped with a heat sensor that will turn
on the blower at third speed if excessive heat occurs
(over149°For65°C)surroundingthecontrolarea.
IftheblowerisOFForifitisoperatingatrstspeed,the
blower will be set automatically to third speed, the display
showstheword“CArE”toindicatethatheatsensorhas
detected an excessive heat.
During this state, the user may raise the blower speed to
fourth speed but can not decrease the speed.
When the temperature level on the hood drops to normal,
theblowerwilloperateinthesettingdenedbytheuser
before the alarm occured.
Maintenance
ATTENTION! Before performing any maintenance opera-
tion, isolate the hood from the electrical supply by switching
off at the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
Do not spray cleaners directly to the control while cleaning the
Hood.Thecookerhoodshouldbecleanedregularly(atleast
with the same frequency with which you carry out maintenance
ofthefatlters)internallyandexternally.Cleanusingthecloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING:
Failuretocarryoutthebasiccleaningrecommendationsof
thecookerhoodandreplacementoftheltersmaycausererisks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage
tothemotororanyredamagelinkedtoinappropriate
maintenance or failure to observe the above safety
recommendations.
Grease Filter
Traps cooking grease particles.
Theltersshouldbewashedfrequentlyusingnonaggressive
detergents, either by hand or in the dishwasher, which must be
set to a low temperature and a short cycle.
Whenwashedinadishwasher,thegreaseltermaydiscolour
slightly,butthisdoesnotaffectitslteringcapacity.
Toremovethegreaselter,pullthespringreleasehandle.
12
Replacing the Halogen Lamps
Turn off the hood insert and allow the halogen lamp to cool.
To avoid damage or decreasing the life of the new bulb, do
nottouchbulbwithbarengers.Replacebulb,usingtissueor
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are in-
serted correctly before calling service.
Disconnect power.
Push up on the lens and turn
it counterclockwise.
Remove the bulb and replace
itwitha120-volt,50-watt
maximum halogen bulb with a
GU10 base. Turn it clockwise
to lock it into place.
Repeatsteps2-3fortheother
bulb if needed.
Reconnect power.
1.
2.
3.
4.
5.
Available Accesories
Charcoal Filter
If the model is not vented to the outside, the air will be recir-
culatedthroughdisposablecharcoalltersthathelpremove
smoke and odors.
Thecharcoallterscannotbecleaned.
They must be replaced.
Cover the grill that protects the suction motor with the carbon
ltersothattheslotsontheltercorrespondtothepinson
the sides of the motor protection grill.
Turnthecarbonlterclockwisetoblockthem(bayonetxing).
Thecharcoalltersshouldbereplacedevery4-6months
(dependingonhoodusage).
NOTE: DO NOTrinse,orputcharcoalltersinanautomatic
dishwasher.
NOTE: Charcoalltersarenotincludedwiththehood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width
size.
Air deector installation (Recirculating version)
Assembletheairdeectorwiththeductcoverbracket
with2-assemblyscrewsprovided.
A
C
B
B
Measurefromthebottomoftheairdeectortothe
bottom of the hood outlet.
X
A
C
D
B
E
Cuttheducttothemeasuredsize(X).
Removetheairdeector.
Slidetheductontothebottomoftheairdeector.
Placetheassembledairdeectorandductoverthe
exhaust outlet from the hood.
Reassembletheairdeectortotheductcoverbracket
with 2 assembly screws.
Seal connections with vent clamps.
1.
2.
3.
4.
5.
6.
7.
8.
A.Ventcoverbracket
B. 2.9 x 6.5 mm screws
C.Deector
A.Airdeector
B.Ventclamp
C.X=lengthtocutventduct
D.Ventduct
E. Exhaust outlet
ELICA North America
TWO-YEAR LIMITED WARRANTY
TO OBTAIN SERVICE UNDER WARRANTY
Owner must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in
order to obtain service under warranty.
PARTS AND SERVICE WARRANTY
For the period of two (2) years from the date of the original purchase, Elica will provide free of charge, non consumable
parts or components that failed due to manufacturing defects. During these two (2) years limited warranty, Elica will also
provide free of charge, all labor and in-home service to replace any defective parts.
WHAT IS NOT COVERED
Damage or failure to the product caused by accident or act of God, such as, flood, fire or earthquake.
Damage or failure caused by modification of the product or use of non-genuine parts.
Damage or failure to the product caused during delivery, handling or installation.
Damage or failure to the product caused by operator abuse.
Damage or failure to the product caused by dwelling fuse replacement or resetting of circuit breakers.
Damage or failure caused by use of product in a commercial application.
Service trips to dwelling to provide use or installation guidance.
Light bulbs, metal or carbon filters and any other consumable part.
Normal wear of finish.
Wear to finish due to operator abuse, improper maintenance, use of corrosive or abrasive cleaning products/pads and
oven cleaner products.
WHO IS COVERED
This warranty is extended to the original purchaser for products purchased for ordinary residential use in North America
(Including the United States, Guam, Puerto Rico, US Virgin Islands & Canada).
This warranty is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of
the product. This warranty is made expressly in lieu of all other warranties, expre
ssed or implied, including, but not limited
to any implied warranty of merchantability or fitness for a particular purpose and all other obligations on the part of Elica
North America, provided, however, that if the disclaimer of implied warranties is ine
ective under applicable law, the dura
-
tion of any implied warranty arising by operation of law shall be limited to two (2) years from the date of original purchase
at retail or such longer period as may be required by applicable law.
This warranty does not cover any special, incidental and/or consequential damages, nor loss of profits, su
ered by the
original purchaser, its customers and/or the users of the Products.
WHO TO CONTACT
To obtain service under warranty or for any service related question:
Elica North America Service, call at 1 888 732 8018
For Eastern Canada, call AGI Services at 1 888 651 2534 Ask for the service department
elica@servicepower.com
Register your product in
elica.com
and earn a 3
rd
year of factory
warranty, covering all parts
plus in-home labor.
15
Français
Sommaire
Avis de sécurité important.................................................................................................................................. 16
Exigences électriques et exigences d’installation........................................................................................ 17
Exigences électriques ................................................................................................................................................................................... 17
Avantd’installerlahotte.................................................................................................................................................................................17
Liste des pièces ................................................................................................................................................... 18
Pièces fournies ............................................................................................................................................................................................. 18
Pièces non fournies ...................................................................................................................................................................................... 18
Dimensions et Dégagement................................................................................................................................ 18
Exemples et possibilités de positionnement des conduits ............................................................................ 19
Préparation de l’Installation................................................................................................................................ 19
Placer les équerres du conduit de cheminée................................................................................................................................................. 20
Conduits au paroi / plafond............................................................................................................................................................................ 20
Installation ........................................................................................................................................................... 21
Monter la hotte............................................................................................................................................................................................... 21
Raccordement Electrique............................................................................................................................................................................... 22
Description de la hotte et des commandes....................................................................................................... 23
Commandes................................................................................................................................................................................................... 23
Nettoyage.............................................................................................................................................................. 24
Accessoires.......................................................................................................................................................... 25
Garantie ................................................................................................................................................................ 26
APPROUVÉ POUR LES APPAREILS DE TYPE RÉSIDENTIEL
POUR UNE UTILISATION RÉSIDENTIELLE SEULEMENT
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER.
L’INSTALLATION DE L’APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR.
IMPORTANT : Conservez ces instructions an de pouvoir les remettre à l’inspecteur-électricien de votre
région.
INSTALLATEUR : Veuillez laisser ces instructions avec l’appareil pour le propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour pouvoir vous y référer plus tard.
Avertissement de sécurité : Coupez l’alimentation du circuit dans le panneau électrique et verrouillez le
panneau avant de raccorder les ls de cet appareil.
Exigence : 120 V c.a., 60 Hz circuit de dérivation de 15 V c.a., 20 Hz, de 15 ou 20 A.
16
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
Avis de sécurité important
ATTENTION
UTILISER CET APPAREIL À DES FINS DE VENTILATION
GÉNÉRALE SEULEMENT. NE PAS UTILISER CET
APPAREIL POUR ÉVACUER DES MATÉRIAUX OU DES
VAPEURS DANGEREUX OU EXPLOSIFS.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC
ÉLECTRIQUE ET DE BLESSURE, RESPECTER LES
DIRECTIVES SUIVANTES :
Utilisercetappareiluniquementauxnsprévuesparle
fabricant.Sivousavezdesquestionsàproposde
l’appareil,communiquezaveclefabricant.
Avantdefairel’entretiendel’appareiloudelenettoyer,
coupezl’alimentationdanslepanneauélectriqueet
verrouillezlepanneauenbloquantledispositif
permettantd’empêcherd’activerl’alimentation
accidentellement.S’iln’estpaspossibledeverrouiller
l’accèsaupanneau,xezuneétiquettetrèsvoyanteau
panneau électrique.
Unepersonnequaliéedoiteffectuerl’installationetle
câblagedeslsélectriquesenconformitéavectousles
codes et toutes les normes, y compris la cote de
résistance au feu.
Ilestimportantdeprévoirsufsammentd’airpour
assurerunebonnecombustiondel’équipementde
chauffeetl’évacuationadéquatesdesgazparleconduit
decheminéandeprévenirlesrefoulementsd’air.
Respectezlesdirectivesetlesnormesdesécuritédes
fabricantsdel’équipementdechauffage,commecelles
publiéesparlaNationalFireProtectionAssociation
(NFPA),laAmericanSocietyforHeating,Refrigeration
andAirConditioningEngineers(ASHRAE)etlecode
des autorités de votre région.
Au moment de couper ou de percer un mur ou un
plafond,assurez-vousdenepasendommagerlalerie
électriqueoutoutautreaccèsàunservicepublique.
Ilfauttoujoursévacueràl’extérieurlessystèmesà
conduit.
ATTENTION
Pourréduirelesrisquesd’incendieetévacuerl’air
correctement,assurez-vousqueleconduitmèneàl’extérieur;
ilnefautpasévacuerl’airdansl’espaceentrelesmurs,dans
les plafonds, dans les greniers, les vides sanitaires ou les
garages.
AVERTISSEMENT
POUR RÉDUIRE DES RISQUES D’INCENDIE, UTILI-
SEZ UNIQUEMENT DES CONDUITS EN MÉTAL.
Installezcettehotteenrespectanttouteslesexigences
mentionnées.
AVERTISSEMENT
Pour réduire les risques d’incendie et de choc
électrique, n’utilisez pas cette hotte avec un contrôleur
de vitesse à semi-conducteurs.
A.
B.
C.
D.
E.
F.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE DE
GRAISSE SUR LES CUISINIÈRES.
Nelaissezjamaislacuisinièresanssurveillance
lorsqu’elleestrégléeàunehautetempérature.Les
débordements par bouillonnement causent de la fumée
etdesdébordementsdegrasquipeuvents’enammer.
Faiteschaufferl’huilelentement,àunetempérature
basse ou moyenne.
Faitestoujoursfonctionnerlahottelorsquevousutilisez
lacuisinièreàunehautetempératureouquevousfaites
amberdesaliments(P.ex.:crêpesSuzette,cerises
jubilées,boeufaupoivreambé).
Nettoyezleshélicesdeventilationfréquemment.Ilne
fautpasquelagraisses’accumulesurleslresoules
hélices.
Utilisezlebonformatdecasserole.Utiliseztoujoursun
chaudrondetailleappropriéàl’élémentdelacuisinière.
AVERTISSEMENT
POURÉVITERDEBLESSERQUELQU’UNLORSD’UN
INCENDIEDEGRAISSESURLACUISINIÈRE,SUIVRE
LESCONSEILSSUIVANTS:
a
ÉTOUFFERLESFLAMMESavecuncouvercleaux 
dimensionsdelataquedecuisson,unetôleàbiscuitou
toutautreplateaumétallique,puiscouperlegazou
l’alimentationélectriquedelacuisinière.FAIRE
ATTENTIONANEPASSEBRÛLER.Silesammesne
s’éteignentpasimmédiatement,QUITTERLAPIÈCEET
APPELER LES POMPIERS.
NEJAMAISPRENDREENMAINUNECASSEROLE
ENFEU,vouspourriezvousblesser.
NEPASUTILISERD’EAU,ycomprislesessuiesde
vaisselle ou les serviettes humides – une violente
explosiondueàlavapeurforméepourraitsurvenir.
Utiliser un extincteur SEULEMENT si:
Vousêtessûrd’avoirunextincteurdeclasseABCque
voussavezutiliser.
Lefeuestpetitetconnéàlazoneoùils’estformé.
Les pompiers ont été appelés.
Vouspouvezluttercontrelefeuavecunesortie
derrière vous.
a
Recommandations tirées des conseils de sécurité en cas
d’incendiedecuisinepubliésparlaNFPA.
MODE OPÉRATOIRE
Toujourslaisserlesgrillesdesécuritéetlesltresàleur
place. Sans la présence de ces derniers, les parties
aspirantes pourraient attirer les cheveux, les doigts ou
lesvêtements.
Le fabricant décline toute responsabilité si les informations
détailléesdanscemanuelpourl’installation,l’entretienet
l’utilisationadéquateduproduitnesontpasobservées.Le
fabriquant décline en outre toute responsabilité pour
d’éventuellesblessuresduesàdesnégligences;enoutre,la
garantiedel’appareilseraannuléesuiteàdesconditions
d’entretieninappropriées.Cetappareilestfabriquépourun
usageinterne.Nepasutilisercetappareilàl’extérieur.
a)
b)
c)
d)
a)
b)
c)
d)
1)
2)
3)
4)
a.
17
Exigences électriques et exigences d’installation
Exigences électriques
IMPORTANT
Respecteztouslescodesetlesordonnancesenvigueur.
Le client a la responsabilité de :
Contacterunélectricien-installateur.
Vérierquel’installationélectriqueestadéquateet
conformeavecleCodenationaldel’électricité,ANSI/NFPA
70(laplusrécenteédition*),oulesnormesC22.1-94,Code
canadiendel’électricité,Partie1etC22.2No.0-M91
(Laplusrécenteédition**)delaCSA,ainsiquetousles
codes et les ordonnances de votre région.
Silecodelepermetetquevousutilisezunldemiseàla
terredistinct,ilestrecommandédefairevérierlechemin
dulparunélectricien.
Nepasmettrel’appareilàlaterresuruneconduitedegaz.
Consultezunélectricienqualiésivousn’êtespascertain
quelahotteestmiseàlaterrecorrectement.
N’installezpasunfusibledanslecircuitneutreoulecircuit
demiseàlaterre.
IMPORTANT
Conservezcesinstructionsandepouvoirlesremettreà
l’inspecteur-électricien.
Lahottedoitêtrecâbléeuniquementàl’aidedelsde
cuivre.
Ilfautraccorderlahottedirectementàuneboîteàfusibleou
àundisjoncteurparl’entremised’unecanalisation
électrique en métal.
LecalibredeldoitêtreconformeauxexigencesduCode
nationaldel’électricité,ANSI/NFPA70(Laplusrécente
édition*),oulesnormesC22.1-94,Codecanadiende
l’électricité,Partie1etC22.20-M91(Laplusrécente
édition**)delaCSA,ainsiquetouslescodesetles
ordonnances de votre région.
Il faut prévoir un connecteur de canalisation approuvé par
l’ULoulaCSAàchaqueextrémitédelacanalisation
d’alimentation(Àlahotteetàlaboîtedejonction).
Vouspouvezobtenirunexemplairedesnormesindiquéesenvous
adressantà:
*LaNationalFireProtectionAssociation,BatterymarchPark
Quincy,Massachusetts,02269
**LaCSAInternational,8501EastPleasantValleyRoad,
Cleveland,Ohio,44131-5575
Avant d’installer la hotte
Pourassurerlaventilationlaplusefcacepossible,
installezlaconduiteenlignedroiteouaveclemoinsde
coudes possibles.
ATTENTION : La sortie de la conduite de ventilation
doitdonnersurl’extérieur.
Deux personnes sont nécessaires pour effectuer
l’installation.
Laquincailleriefourniepermetdexerlahotteàla
plupartdesmursetdesplafonds;consultezun
installateurqualiépourvousassurerquelaquincaillerie
fournieestadaptéeàvotretypedemuroud’armoire.
N’utilisezpasdeconduitexible. 
Dans le cas des endroits sujets aux TEMPÉRATURES
FROIDES,ilfautinstallerunclapetdecontre-tirage
supplémentaireandeminimiserleretourd’airfroidet
unisolantthermiquenonmétalliqueandeminimiserla
conduction de la température extérieur dans le conduit.
Ilfautplacerleclapetducôtédel’airfroiddel’isolant
thermique.
L’isolantdoitêtreplacéleplusprèspossibledel’endroit
oùleconduitentredanslapartiechaufféedelamaison.
Aird’appoint:Lecodedubâtimentdevotrerégionpeut
exigerl’utilisationd’unsystèmed’aird’appointsivous
utilisezunsystèmedeventilationàconduitdontle
mouvementd’airdépasseuncertainnombredeCFM.
Lenombredepi3/minvaried’unerégionàl’autre.
ConsultezunprofessionneldeCVCpourconnaîtreles
exigences précises de votre région.
1.
2.
3.
4.
5.
6.
18
Liste des pièces
Pièces fournies
Enleverl’emballage
ATTENTION
Enlever délicatement le carton, Porter des gants pour se
protéger des bords coupants.
ATTENTION:Retirezsoigneusementlaverrièredelaboîte
et le mettre sur un surface lisse sans danger.
Saisirlastructuredelahotteducorpsetsoulevez-lacase.
Enlevezetjeteztouslescartonsetemballagesplastiques
contenus dans le paquet.
Enleverlespartieshorsdelaboîte,conduitsetautresconte
-
nus.
Auvent de hotte avec ventilateur e raccord de transition
2 lampes halogene.
2Filtreàgraissemétallique
Conduitedecheminée.-2pièces
Sac de matériel avec:
Gabarit de montage
Supportdeconduit(
1 pièce)
Instructionsd’installationetGuided’utilisationet
d’entretien
Visdemontage(6
pièces-3/16”x1”3/4)
Ancres de mur
2-8x40ancres
4-10x50ancres
Visd’assemblage
2-2.9x6.5vis
2-3.5x9.5vis
Pièces non fournies
Accessoires Optionnel
Troussedeconversionenhotteàrecyclageàutiliser
seulementaveclaversionsansconduit(Àrecyclage)
comprend:2ltresaucharbonetdéecteur
FiltreAnti-graisseenAcierInoxydableProfessionnel.
Outils nécessaires
Ecrous métalliques
Ruban pour le gabarit de montage
Conduitmétalliquecirculairede8”pourparfaire
l’installation
Mètre ruban
Tenailles
Gants
Couteau
Lunettes de sécurité
Foreuseélectrique5/16”et3/8”
Réducteur de tension
Niveau
Toile isolante
TournevisPhillips(Pozidrive)
Tournevis Torx
Dénudeur
Ruban de masquage
Marteau
Scie, scie circulaire
Dimensions du Produit
*Seulement avec la version sans
conduit(àrecyclage)
**Seulement avec la version version
àcondui
30” (76.2cm)
36” (91.2 cm
1½”
(4 cm)
24
1
/
8
(61 cm)
10”
(25.4 cm)
7¼” (18.4 cm
*28
7
/
8
” (73.3 cm) min
*42
1
/
16
” (106.9 cm) max
**28
3
/
8
” (72 cm) min
**38” (96.6 cm) max
6”
8
1
/8” (20.7 cm
21½” (54.7 cm)
19
Exemples et possibilités de positionnement des conduits
Suivez à la lettre les directives présentées dans ce manuel.
Lefabricantrefusetouteresponsabilitéencequiatraitàtoutpréjudice,dommageouincendiecauséparlanonobservation
des directives contenues dans le présent manuel.
Méthodes de ventilation
Lahotteestdotéed’unetransitionBand’évacuerlesvapeursàl’extérieur(versionàconduit).
S’ils’avèreimpossibled’évacuerlafuméeetlesvapeursdecuissonàl’extérieur,ilestpossibledetransformerlahotteenver
-
sionsansconduit(Recyclage)Fixerunltreaucharbonetledéceteur
F sur le support de couvercle de conduit G. La fumée
et la vapeur sont recyclées par la grille supérieure Hparl’entremised’unconduitraccordéàlatransitionBetàlatransition
montéesurledéecteur
F.
NOTE:danslecasdelaversionsansconduit(Àrecyclage)seulement:procurez-vouslatroussedeconversionen
hotteàrecyclage.
Diamètreminimumdesconduit(Versionavecousansconduit):tuyaurondde6”.
Préparation
Necoupezpasunesoliveouunmontantàmoinsqu’ilsoitabsolumentnécessairedelefaire.Sivousdevezcouperunesolive
ouunmontant,vousdevezconstruireuncadredesoutien.
Laquincailleriefourniepermetdexerlahotteàlaplupartdesmursetdesplafonds.
Vousdevezcependantdemanderàuntechnicienqualiédevérierlasoliditédesmatériauxselonletypedemuroudepla
-
fond.
Avantdecouper,assurez-vousqu’ilyaundégagementsufsantdansleplafondoulemurpourpasserlaconduitedesortie.
INSTALLATION:
DANS PLAFONDS DE 9’: METTEZ LA HOTTE AFIN D’AVOIR ENTRE LE BORD INFERIEUR DE LA HOTTE ET LE PLAN
DE CUISSON UNE DISTANCE DE 30” (76,2 CM).
Vériez donc la hauteur de votre plafond et la hauteur maximum de la hotte avant de choisir votre modèle de hotte.
Utilisezunconduitenmétalseulement.
REMARQUE:unsystèmedeventilation,commeunahottedelacuisiniere,peutinterromprelauiditédel’airdecombustion
etlasortied’airnécessaireparlesincendies,cuisinièresàgaz,basedegazchauffe-eauetd’autres.
Andeminimiseretdeprévenirce,suivrelesnormesdesécuritécommecellespubliéesparNFPAetASHRAE.
Uncircuitd’évacuationenconduitrondde6”(15,2cm)estnécessairepourl’installation.
tuyau
Transition(B)
Pente de boit
avec solin et chapeau
tuyau
Transition(B)
Chapeau de
paroi latérale
avec clapet
antirefoulement
tuyau
Transition(B)
Filtro
Deécteur(F)
Grillesupérieure(H)
Support de couvercle de
conduit(G)
EvacuationVerticale Recyclaged’air
20
Placer les équerres du conduit de
cheminée
Option A - Régler la hauteur du couvercle du conduit
From the horizontal line traced in the previous section,
trace a horizontal parallel line as shown below.
Aligner les lignes médianes tracées sur les équerres
avec les lignes médianes sur le mur.
Marquer l’emplacement des trous sur le mur.
Aligner les lignes médianes tracées sur les équerres
avec les lignes médianes sur le mur.
Indiquer les 2 trous pour les vis sur le mur.
Forer des trous pilotes de 5/16” sur les emplacements
indiqués.
Placer les attaches d’accrochage au mur.
Visser les vis à bois, à la main, dans les attaches pour
permettre aux crochets de se dilater. Enlever les vis.
Attacher l’équerre dans le mur à l’aide des vis à bois
et/ou des attaches.
Option B - Couverture télescopique
Le conduit de cheminée doit être installé contre le mur de
fond et au niveau du plafond.
Cette équerre va maintenir le conduit de cheminée en place
au sommet.
Attacher les équerres au mur:
Aligner les lignes médianes tracées sur les équerres
avec les lignes médianes sur le mur.
Indiquer les 2 trous pour les vis sur le mur.
Forer des trous pilotes de 5/16” sur les emplacements
indiqués.
Placer les attaches d’accrochage au mur.
Visser les vis à bois, à la main, dans les attaches pour
permettre aux crochets de se dilater. Enlever les vis.
Attacher l’équerre dans le mur à l’aide des vis à bois
et/ou des attaches.
Conduit au plafond
Si le conduit ventile juste au-dessus du plafond:
Utiliser un niveau pour tracer une ligne, de la ligne
médiane du gabarit jusqu’au plafond.
Mesurer au moins 4 -12/16 ” du mur arrière jusqu’au
centre du cercle d’un trou de 6½” dans le plafond.
Conduit dans le mur
Si le conduit ventile à l’arrière:
Utiliser un niveau pour tracer une ligne droite à partir de
la ligne centrale sur le gabarit.
Measure at least 26- ¼” (la mesure peut varier selon
le coude utilisé) au-dessus de la ligne au crayon qui
indique la hauteur du fond de l’installation, au centre du
cercle d’un trou de conduit 6-½” de diamètre (Le trou
peut être agrandi pour le passage du coude).
Situation de l’installation électrique
Ligne verticale de centre
P
l
a
f
o
n
d
Mur
Pour evacuation par le plafond4
12
/16” centre du
cercle au mur
Plafond
6½” diamétre trou
Pour evacuation arriere
Centre du cercle a
23
12
/16” a dessus
de la ligne mar-
queé au crayon
Ligne horizontale
au crayon
ligne de Centre
Ligne de équerre
27
28
/32
Ligne horizontal marquée en crayon
Hauteur d’installation désirée
La boîte de connexion est située sur le côté gauche
supérieur de la hotte.
Le câble doit entrer dans le mur arrière à au moins
20-1/4” au-dessus de la hauteur du fond de l’installation,
et 3
5
/16” du côté gauche de la ligne médiane.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

ELICA EPL630S1 Le manuel du propriétaire

Catégorie
Hottes
Taper
Le manuel du propriétaire
Ce manuel convient également à