Cooper Lighting Solutions IB520143ML Manuel utilisateur

Taper
Manuel utilisateur
INS #
IB520143ML PORTFOLIOTM
Installation Instructions – Portfolio LuxWire™ Cylinders
Directives d’installation – Portfolio LuxWire™ Cylinders
Instrucciones de instalacn – Portfolio LuxWire™ Cylinders
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of
the product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or
attempting any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Minimum 9C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Failure to comply with these instructions may result in death, serious bodily injury and property
damage.
WARNING
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
NOTICE: Fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
Note: This fixture should be supported by main runners or other structure that is capable of supporting fixture
weight of 40 Ibs.
ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
2
Cooper Lighting Solutions IB520143ML Installation instructions
Installation Instructions – Portfolio LuxWire™ Cylinders
1. Up Down Installation Instructions
1. Cylinder comes fully assembled when received. To
install remove #8-32 nut located in the center of the
2 aircraft cables. The canopy can fall out of the way to
expose the mounting strap. (Figure 1)
Figure 1.
Figure 2.
Figure 3.
Canopy
#8-32 Screw (2X)
J-Box
Canopy
Aircraft Cables
Aircraft Cables
Aircraft Cables
#8-32 Nut
#8-32 Nut
#8-32 Nut
#8-32 Screw (2X)
Strap
Strap
Splice Cover
Driver
Strap
2. Connect the mounting strap to the J-Box (supplied by
others) with 2 #8-32 screws. (Figure 2)
3. For options with the driver in the canopy, there is a
splice cover to provide a barrier to the ceiling and
the driver is attached to the mounting strap. Make
connections to Driver following local code and seeing
the wiring diagrams mentioned in the electrical section.
(Figure 3)
4. For remote driver options, connect remote driver to
J-box following the instruction provided in the kit. Then
connect the remote harness to the aircraft cable using
the orange connectors attached to the ends of each
side.
5. Once wiring is complete, slide the canopy back up to
the ceiling and secure back with the #8-32 nut. Clip zip
ties that is holding the aircraft cable, so the cylinder can
hang free.
6. To adjust height, use cable fittings located on the
cylinder body. Push the fitting to pull the cable through
and be sure to clip the ends so the cable does not
contact any metal components.
7. Heat shrink is provided to insulate the cables from
the cylinder body. Recommend putting the heat shrink
where the cable contact the cylinder next to cable
fitting.
J-Box
3
Cooper Lighting Solutions IB520143ML Installation instructions
Installation Instructions – Portfolio LuxWire™ Cylinders
Figure 4.
Canopy
Aircraft Cables
Strap
#8-32 Flat Head
Screw (2X)
1.2. Down Light Installation Instructions
1. Cylinder comes fully assembled when received. To
install remove 2 #8-32 flat head screws from canopy
located outside of the 2 aircraft cables. The canopy
can fall out of the way to expose the mounting strap.
(Figure 4)
2. Connect the mounting strap to the J-Box (supplied by
others) with 2 #8-32 screws. (Figure 2)
3. For options with the driver in the canopy, there is a
splice cover to provide a barrier to the ceiling and
the driver is attached to the mounting strap. Make
connections to Driver following local code and seeing
the wiring diagrams mentioned in the electrical section.
(Figure 3)
4. For remote driver options, connect remote driver to
J-box following the instruction provided in the kit. Then
connect the remote harness to the aircraft cable using
the orange connectors attached to the ends of each
side.
5. Once wiring is complete, slide the canopy back up to
the ceiling and secure in place with 2 #8-32 flat head
screws. Clip zip ties that is holding the aircraft cable, so
the cylinder can hang free.
6. To adjust height, the cylinder top needs to be removed
by removing 4 screws, then use cable fittings located
on the cylinder on the cylinder top. Push the fitting to
pull the cable through and be sure to clip the ends so
the cable does not contact any metal components.
Then reinstall to cylinder.
2. Trim
1. Remove lower trim from protective packaging. Rotate
side clips (3) outwards. (Figure 5) Remove LED Engine
from protective packaging.
2. Insert LED engine on to trim assembly. Align post on
LED engine with slot on trim assembly. (Figure 6)
Figure 5.
Figure 6.
4
Cooper Lighting Solutions IB520143ML Installation instructions
Installation Instructions – Portfolio LuxWire™ Cylinders
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Screw
Green
Ground
Wire
Lockwasher
Heatsink Screw
Boss
Torsion Spring
Reciever
3. Rotate side clips (3) into place to securely attach trim
assembly to LED engine. (Figure 7)
4. Plug in the luminaire quick disconnect on the module.
(Figure 8)
5. Find the green tether inside cylinder and attach it to the
heatsink using the screw and lock washer located in
the envelope attached to the tether. (Figure 9)
6. Install the LED Engine and trim assembly by inserting
the torsion springs into the spring receivers located
inside the housing. (Figure 10)
Cleaning
1. To Clean Trims:
2. Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
3. Wipe with mild detergent solution on a soft, clean cloth
to remove fingerprints and stains.
4. Rinse with clean water and dry with soft, clean, dry lint-
free cloth.
Electrical Connection
Make certain no bare wires are exposed outside of wire nut
connectors.
1. Provide electrical service according to the “National
Electrical Code” or your local electrical code to the
cylinder housing assembly. Supply wire insulation must
be rated for at least 90°C.
2. Connect supply lead wires to cylinder housing lead
wires (line, neutral and ground) in the fixture using
properly sized wire nuts. Be careful not to leave any
bare conductors outside of the wire nut connectors.
3. Connect white to white, black to black, and green (from
electrical service) on the supply side to the green wire
in the cylinder housing assembly.
5
Cooper Lighting Solutions IB520143ML Installation instructions
Installation Instructions – Portfolio LuxWire™ Cylinders
BLACK (LINE) BLACK (LINE)
WHITE
(NEUTRAL)
WHITE
(NEUTRAL)
GRN
BLUE
RED
PURPLE
PINK*
BLACK
LED
RED
MOUDLE WIRING
DIAGRAM
0-10V
DIMMING
OPTION (FIELD
INSTALLATION)
TRIAC DIMMING
@120VAC OR 0-10V
@ 120 277VAC
DIMMING DRIVER
CONNECTOR
CONNECTOR
2. For D010TE Driver
BLACK (LINE) BLACK (LINE)
WHITE
(NEUTRAL) WHITE
(NEUTRAL)
GRN
BLACK
RED
PURPLE
PINK*
BLACK
LED
RED
MOUDLE WIRING
DIAGRAM
0-10V DIMMING
OPTION (FIELD
INSTALLATION)
TRAILING EDGE
DIMMING OR
0-10V DIMMING
DRIVER
CONNECTOR
CONNECTOR
Wiring Diagrams
1. For D010TR Driver
3. DL3 Driver
BLACK (LINE)
WHITE(COMMON)
GRN
BLACK
RED
PURPLE
ORANGE
PURP/WHT
BLACK
LED
RED
GREEN
3 WIRE DIMMING (FIELD
INSTALLATION ONLY)
LUTRON ECOSYSTEM
DIGITAL CONTROL
DIMMING FIELD
INSTALLATION ONLY
LUTRON
DRIVER
(120V-277V)
CONNECTOR
CONNECTOR
5. For D5LT Driver
BLACK (LINE)
WHITE(COMMON)
GRN
BLUE
BLACK BLACK
PURPLE
PURP/WHT
LED
RED
RED
GREEN
MOUDULE WIRING
DIAGRAM
DRIVER
(120V-277V)
DIMMING LEADS
BRN
DA
GRP 1
CONNECTOR
CONNECTOR
+
+
-
-
~
~
MOUDULE WIRING
DIAGRAM
7. For DE010 Driver
BLACK (LINE)
GREEN
WHITE
(NEUTRAL)
WHITE
(NEUTRAL) 0-10V DIMMING
DRIVER
BLACK (LINE)
BLACK BLACK
RED
PURPLE
PINK*
LED
RED
MODULE WIRING
DIAGRAM
0-10V DIMMING
FIELD INSTALL
CONNECTOR
CONNECTOR
4. For D010 Driver
BLACK (LINE) BLACK (LINE)
WHITE
(NEUTRAL)
WHITE
(NEUTRAL)
GROUND
0-10V DIMMING
DRIVER
RED RED
BLUE
PURPLE
PINK*
LED
BLACK
MOUDLE WIRING
DIAGRAM
0-10V
DIMMING
OPTION
(FIELD
INSTALLATION)
CONNECTOR
CONNECTOR
8. For DL2 Driver
CONNECTOR
CONNECTOR
BLACK (DIM HOT)
WHITE (COMMON)
GREEN
GROUND
RED RED
BLUE
BLACK
LED
MODULE WIRING
DIAGRAM
LUTRON
FORWARD PHASE
DIMMING DRIVER
(120V)
6. For DMX Driver*
CONNECTOR
CONNECTOR
WHITE (COMMON)
GREEN
GROUND
RED RED
BLUE
BLACK
DMX IN + (FURNISHED BY OTHERS)
BLACK (LINE)
~ BLUE
~BROWN
GROUP 1
+
+
-
-
DMX DIMMING
DRIVER
(120V-277V)
DMX in
LED
MOUDLE WIRING
DIAGRAM
DMX in shield
DMX in DMX IN - (FURNISHED BY OTHERS)
DMX IN SHIELD (FURNISHED BY OTHERS)
DMX OUT + (FURNISHED BY OTHERS)
DMX OUT - (FURNISHED BY OTHERS)
DMX OUT SHIELD (FURNISHED BY OTHERS)
6
Cooper Lighting Solutions IB520143ML Installation instructions
Installation Instructions – Portfolio LuxWire™ Cylinders
Dimming
The Portfolio *D010 Cylinders can be dimmed with many
standard 0-10V DC dimming controls. The Portfolio *D010TE
Cylinders can be dimmed with many trailing edge dimmers
and 0-10V DC dimming controls. The Portfolio *DL2
Cylinders can be dimmed with Lutron 2-wire forward phase
controls. The Portfolio *D5LT Cylinders can be dimmed
with Fifth Light and DALI compatible controls. The Portfolio
*DMX Cylinders can be dimmed with DMX compatible
controls. The Portfolio *DE010 Cylinders can be dimmed
with 0-10V DC dimming controls but are NOT to be dimmed
using line voltage dimmers. The Portfolio *DLE Cylinders
can be dimmed with Lutron EcoSystem® digital controls. To
be assured of the latest information regarding luminaire and
dimmer compatibility, please reference the Portfolio LED
website: www.portfolio-lighting.com.
9. For DLE Driver
CONNECTOR
CONNECTOR
BLACK (LINE)
GROUND
RED RED
BLUE
PURPLE
PURPLE BLACK
LED
MOUDLE WIRING
DIAGRAM
WHITE (NEUTRAL)
LUTRON
ECOSYSTEM
DIMMING
DRIVER
( 120V-277V)
ECOSYSTEM
DIMMING
BLACK (LINE)
WHITE (NEUTRAL)
* Constructions built before Jan 2022 may have gray wire for 0-10
dimming control present. In these cases, the installer will label
the gray building wire as a 0-10 dimming wire and connect to our
product’s pink 0-10V dimming control wire. Reference NFPA70
(2020 NEC), section 410.69.
7
Cooper Lighting Solutions IB520143ML Instructions d’installation
Directives d’installation – Portfolio LuxWire™ Cylinders
Risque d’incendie, de décharge électrique, de coupure ou d’autres dangers- L’installation et la
paration de ce produit doivent être faites par un électricien qualifié. Ce produit doit être installé
conformément au code d’installation applicable par une personne qui connt bien la construction, le
fonctionnement du produit et les dangers encourus.
Risque d’incendie ou de décharge électrique- Assurez-vous que lalimentation électrique est HORS
TENSION avant de commencer l’installation ou de tenter den faire l’entretien. Coupez l’alimentation
électrique au niveau du fusible ou du disjoncteur.
Risque d’incendie- Conducteurs dalimentation puovant supporter un minimum de 90°C.
Risque de brûlure-branchez la source d’alimentation et laissez refroidir le luminaire avant de
procéder à son entretien ou à sa manipulation.
Risque de blessure- À cause des bords tranchants, manipulez ce produit avec soin.
La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et
de dommages matériels.
AVERTISSEMENT
EXONÉRATION DE RESPONSABILITÉ: Cooper Lighting Solutions n’assume aucune responsabilité pour les
dommages ou pertes de toute nature pouvant découler dune installation inappropriée, imprudente ou négligente
et d’une mauvaise manipulation ou utilisation de ce produit.
IMPORTANT: Lisez attentivement avant d’installer le luminaire. Conservez pour consultation ultérieure.
AVIS: Ce luminaire peut s’endommager s’il n’est pas installé correctement ou s’il est instable.
Remarque: Les caractéristiques techniques et les dimensions peuvent changer sans préavis.
Remarque: Ce luminaire doit être supporté par des rails principaux ou une autre structure capable de supporter un
luminaire de 18 kg (40 lb).
ATTENTION Service de la réception: Veuillez fournir une description de tout élément manquant ou de tout dommage
au luminaire constaté au bordereau de réception. Soumettez une réclamation de transporteur public (chargement
partiel) directement auprès du transporteur. Les réclamations pour dommages cachés doivent être faites dans les
15jours suivant la réception. Tout le matériel endommagé ainsi que l’emballage d’origine doivent être conservés.
1. Directives d’installation vers le haut et le bas
1. Le cylindre est entièrement assemblé lorsqu’il est reçu.
Pour installer, retirez l’écrou no8-32 situé au centre des
2 câbles d’aéronef. La monture peut tomber et exposer
la barre de soutien. (Figure1)
Figure 1.
Monture
Câbles
d’aéronef
Écrou no8-32
Barre
Figure 2.
Vis no8-32 (2X)
Boîte de jonction
Câbles d’aéronef
Écrou no8-32
Barre
2. Connectez la barre de soutien à la boîte de jonction
(fournie par d’autres) avec 2 vis no8-32. (Figure2)
8
Cooper Lighting Solutions IB520143ML Instructions d’installation
Directives d’installation – Portfolio LuxWire™ Cylinders
Figure 3. Figure 4.
Monture
Monture
Câbles d’aéronef
Câbles
d’aéronef
Écrou no8-32
Vis no8-32 (2X)
Barre
Barre
Couvercle d’épissure
Pilote
Vis à tête plate
no8-32 (2X)
1.2. Directives d’installation de l’éclairage vers le bas
1. Le cylindre est entièrement assemblé lorsqu’il est reçu.
Pour installer, retirez les 2vis à tête plate no8-32 de la
monture située à l’extérieur des 2câbles d’aéronef. La
monture peut tomber et exposer la barre de soutien.
(Figure4)
3. Pour les options avec le pilote dans la monture, il y a
un couvercle d’épissure pour fournir une protection au
plafond et le pilote est attaché à la barre de soutien.
Effectuez les raccordements au pilote en respectant
le code local et en consultant les schémas de câblage
mentionnés dans la section électrique. (Figure3)
4. Pour les options de pilote de télécommande, raccordez
le pilote à la boîte de jonction en suivant les directives
fournies dans la trousse. Ensuite, connectez le faisceau
de télécommande au câble d’aéronef à l’aide des
connecteurs orange fixés aux extrémités de chaque
côté.
5. Une fois le câblage terminé, faites glisser la monture
vers le plafond et la fixer avec l’écrou no8-32. Coupez
les attaches mono-usage qui retiennent le câble
d’aéronef pour que le cylindre puisse pendre librement.
6. Pour régler la hauteur, utilisez les raccords de câble
situés sur le corps du cylindre. Poussez le raccord
pour faire passer le câble et s’assurer d’attacher les
extrémités pour que le câble n’entre pas en contact
avec un composant métallique.
7. Un isolant thermorétractable est fourni pour isoler les
câbles du corps du cylindre. Il est recommandé de
placer l’isolant thermorétractable à l’endroit où le câble
entre en contact avec le cylindre à côté du raccord de
câble.
Boîte de jonction
2. Connectez la barre de soutien à la boîte de jonction
(fournie par d’autres) avec 2 vis no8-32. (Figure2)
3. Pour les options avec le pilote dans la monture, il y a
un couvercle d’épissure pour fournir une protection au
plafond et le pilote est attaché à la barre de soutien.
Effectuez les raccordements au pilote en respectant
le code local et en consultant les schémas de câblage
mentionnés dans la section électrique. (Figure3)
4. Pour les options de pilote de télécommande, raccordez
le pilote à la boîte de jonction en suivant les directives
fournies dans la trousse. Ensuite, connectez le faisceau
de télécommande au câble d’aéronef à l’aide des
connecteurs orange fixés aux extrémités de chaque
côté.
5. Une fois le câblage terminé, faites glisser la monture
vers le plafond et fixez-la en place avec 2 vis à tête
plate no8-32. Coupez les attaches mono-usage qui
retiennent le câble d’aéronef pour que le cylindre
puisse pendre librement.
9
Cooper Lighting Solutions IB520143ML Instructions d’installation
Directives d’installation – Portfolio LuxWire™ Cylinders
6. Pour régler la hauteur, le haut du cylindre doit être retiré
en retirant 4vis. Utilisez ensuite utiliser les raccords
de câble situés sur le dessus du cylindre. Poussez le
raccord pour faire passer le câble et s’assurer d’attacher
les extrémités pour que le câble n’entre pas en contact
avec un composant métallique. Puis réinstallez sur le
cylindre.
Figure 5.
Figure 6.
2. Insérez le moteurgénérateur de lumière lumineux à
DEL sur dans l’ensemble assemblage de la garniture.
Alignez la tige sur le du moteurgénérateur de lumière à
DEL sur la fente l'assemblage de la garniture. (Figure6)
Garniture
1. Retirez la garniture inférieure de l’emballage de
protection de la garniture inférieure. Faites pivoter
les fixations latérales (3) vers l’extérieur (Figure5).
Retirez le générateur de lumière DEL de l’emballage de
protection du moteur lumineux à DEL.
Figure 7.
Figure 8.
Figure 9. Vis
Fil de mise à la
terre vertvert
Rondelles freins
Bloc de fixation
du dissipateur
thermique
3. Faites pivoter les fixations latérales (3) en place pour
fixer fermement l’assemblage de la garniture au
moteurgénérateur de lumière à DEL. (Figure7)
4. Branchez Connectez la prise de fiche à débranchement
rapide du luminaire sur leau module. (Figure8)
5. Repérez le câble d’attache vert à l’intérieur du cylindre
et fixez-le au dissipateur thermique à l’aide de la vis et
de la rondelle contenues se trouvant dans l’enveloppe
fixée au câble d’attache. (Figure9)
10
Cooper Lighting Solutions IB520143ML Instructions d’installation
Directives d’installation – Portfolio LuxWire™ Cylinders
Figure 10.
Récepteur à
ressort de torsion
NOIR (LIGNE) NOIR (LIGNE)
BLANC
(NEUTRE)
BLANC
(NEUTRE)
VERT
BLEU
ROUGE
POURPRE
ROSE*
NOIR
DEL
ROUGE
SCHÉMA DE CÂBLAGE
DU MODULE
OPTION DE
GRADATEUR
0–10V
(INSTALLÉ SUR
PLACE)
GRADATEUR
À TRIAC À
120VA.C.A.
OU PILOTE DE
GRADATEUR
0-10V DE À 120 À
-277VA.C.A.
CONNECTEUR
CONNECTEUR
2. Pour le piloteD010TE
NOIR (LIGNE) NOIR (LIGNE)
BLANC
(NEUTRE) BLANC
(NEUTRE)
VERT
NOIR
ROUGE
POURPRE
ROSE*
NOIR
DEL
ROUGE
SCHÉMA DE CÂBLAGE
DU MODULE
OPTION DE
GRADATEUR
0-10 V
(INSTALLÉ SUR
PLACE)
GRADATEUR À
BORD DE FUITE
DE GRADATEUR
OU COMMANDE
PILOTE DE
GRADATEUR
0 - 10 V
CONNECTEUR
CONNECTEUR
6. Installez le moteurgénérateur de lumière à DEL et
l’assemblage de la garniture en insérant les ressorts
de torsion dans les récepteurs àde ressort situés à
l’intérieur du boîtier. (Figure10)
Nettoyage
1. Pour nettoyer les garnitures:
2. Essuyez délicatement avec un chiffon doux, propre, sec
et non pelucheux pour enlever la poussière.
3. Essuyez avec un chiffon doux et propre imbibé d’une
solution de détergent doux pour enlever les empreintes
de doigts et les taches.
4. Rincez à l’eau propre, puis séchez avec un chiffon doux,
propre, sec et non pelucheux.
Raccord électrique
Assurez-vous que tous les fils dénudés sont à l’intérieur des
capuchons de connexion.
1. Acheminez l’alimentation électrique à laau boîtier de
jonction (sur le cadre d’enchâssement pour plâtre)
du cylindre selon le Code national de l’électricité ou
le code d’électricité de votre région. L’isolation du fil
d’alimentation doit pouvoir tolérer une température d’au
moins 90°C.
2. Raccordez les fils d’alimentation électrique aux fils
d’alimentation de laà ceux du boîtier de jonction du
cylindre (fils électriquede ligne, neutre et mise à la
terre) dans le luminaire en utilisant une dimension
des capuchons de connexion de dimension adéquate.
Assurez-vous que tous les fils dénudés sont à l’intérieur
des capuchons de connexion.
3. Raccordez les fils blanc à blanc, noir à noir et vert
(de l’alimentation électrique) sur le du côté de
l’alimentation au fil vert dans l’assemblage dule boîtier
du cylindre.
3. PiloteDL3
NOIR (LIGNE)
BLANC (COMMUN)
VERT
NOIR
ROUGE
POURPRE
ORANGE
POURPRE/BLANC
NOIR
DEL
ROUGE
GREENVERT
GRADATEUR À 3 FILS
(INSTALLÉ SUR PLACE
SEULEMENT)
INSTALLATION DU
CHAMP DE GRADATION
À COMMANDE
NUMÉRIQUE
LUTRON ECOSYSTEM
SEULEMENT
PILOTE
LUTRON
(120-277V)
CONNECTEUR
CONNECTEUR
SCHÉMA DE CÂBLAGE
DU MODULE
4. Pour le piloteD010
NOIR (LIGNE) NOIR (LIGNE)
BLANC
(NEUTRE)
BLANC
(NEUTRE)
MISE À LA TERRE
PILOTE DEU
GRADATEUR
0-10V
ROUGE ROUGE
BLEU
POURPRE
ROSE*
DEL
NOIR
SCHÉMA DE CÂBLAGE
DU MODULE
OPTION DE
GRADATEUR
0–10V
(INSTALLÉ SUR
PLACE)
CONNECTEUR
CONNECTEUR
Schémas de câblage
1. Pour le piloteD010TR
11
Cooper Lighting Solutions IB520143ML Instructions d’installation
Directives d’installation – Portfolio LuxWire™ Cylinders
NOIR (LIGNE)
BLANC (COMMUN)
VERT
BLEU
NOIR NOIR
POURPRE
POURPRE/BLANC
DEL
ROUGE
ROUGE
GREENVERT
SCHÉMA DE CÂBLAGE
DU MODULE
PILOTE
(120V-
CONDUCTEURS
DE GRADATEUR
BRUN
DA
CONNECTEUR
CONNECTEUR
+
+
~
~
NOIR (LIGNE)
GREENVERT
BLANC
(NEUTRE)
BLANC
(NEUTRE) PILOTE DEU
GRADATEUR
NOIR (LIGNE)
NOIR NOIR
ROUGE
POURPRE
ROSE*
DEL
ROUGE
SCHÉMA DE CÂBLAGE
DU MODULE
INSTALLATION
SUR PLACE
DU ER LE
CHAMP DE
GRADATEURION
CONNECTEUR
CONNECTEUR
6. Pour le pilote DMX*
CONNECTEUR
CONNECTEUR
BLANC (COMMUN)
MISE À LA TERRE
ROUGE
ROUGE
NOIR
NOIR
DEL
SCHÉMA DE CÂBLAGE
POUR MODULE
NOIR (LIGNE)
~ BLEU
~BRUN
GROUPE 1
+
-
Pilote de
gradateur DMX
(120-277)
DMX IN + (FOURNI PAR DES TIERS)
DMX IN +
DMX IN - DMX IN - (FOURNI PAR DES TIERS)
ENTRÉE DMX DE L’ÉCRAN (FOURNI PAR DES TIERS)
DMX HORS + (FOURNI PAR DES TIERS)
DMX HORS - (FOURNI PAR DES TIERS)
EXISTER DMX DE L’ÉCRAN (FOURNI PAR DES TIERS)
VERT
DMX entrée de l’écran
CONNECTEUR
CONNECTEUR
NOIR (FIL CHARGÉ DU GRADATEUR)
BLANC (COMMUN)
GREENVERT
MISE À LA TERRE
ROUGE ROUGE
BLEU
NOIR
DEL
SCHÉMA DE CÂBLAGE
DU MODULE
PILOTE DEU
GRADATEUR À
PHASE DIRECTE
9. Pour le pilote DLE
CONNECTEUR
CONNECTEUR
NOIR
MISE À LA TERRE
ROUGE ROUGE
BLEU
POURPRE
POURPRE NOIR
DEL
SCHÉMA DE CÂBLAGE
DU MODULE
BLANC (NEUTRE)
PILOTE DE
GRADATEUR
LUTRON
ECOSYSTEM
GRADATEUR
ECOSYSTEM
(ALIMENTATIONLIGNE)
NOIR
(ALIMENTATIONLIGNE)
BLANC (NEUTRE)
Gradation
Le niveau de gradation des cylindres Portfolio * D010
Portfolio peut être contrôlé avec à l’aide de nombreuses
de gradation des cylindres Portfolio * D010TE Portfolio peut
être contrôlé avec à l’aide de nombreux gradateurs à bord
CC. Le niveau de gradation des cylindres Portfolio * DL2
Portfolio peut être contrôlé par à l’aide des commandes à 2
fils à phase directe de Lutron. Le niveau de gradation des
cylindres Portfolio * D5LT Portfolio peut être contrôlé par à
l’aide des commandes compatibles Fifth Light et DALI. Le
niveau de gradation des cylindres Portfolio * DMX Portfolio
peut être contrôlé par à l’aide des commandes compatibles
DMX. Le niveau de gradation des cylindres Portfolio
* DE010 Portfolio peut être contrôlé avec à l’aide des
l'être avec à l’aide des gradateurs de à tension composée.
Le niveau de gradation des cylindres Portfolio * DLE
Portfolio peut être contrôlé avec les à l’aide de commandes
numériques Lutron EcoSystemMD. Pour vous assurer de
posséder les disposer de l’informations laes plus récentes
à propos de la compatibilité du gradateur et du luminaire,
veuillez consulter le site Web des luminaires à DEL de
12
Cooper Lighting Solutions IB520143ML Instrucciones de instalación
Instrucciones de instalación – Portfolio LuxWire™ Cylinders
Riesgo de incendio, descarga eléctrica, cortes u otros riesgos de accidentes: La instalación y el mantenimiento
de este producto deben ser realizados por un electricista calificado. Este producto debe ser instalado de
acuerdo con el código de instalación correspondiente por una persona familiarizada con la construcción y
operación del producto y los riesgos involucrados.
Riesgo de incendio/descarga eléctrica: Asegúrese de que la alimentación esté APAGADA antes de
comenzar la instalación o intentar cualquier mantenimiento. Desconecte el suministro eléctrico desde el
fusible o el disyuntor.
Riesgo de incendio: Conductores mínimos de suministro de 90°C.
Riesgo de quemaduras: desconecte la alimentación y espere que la luminaria se enfríe antes de
manipularla o repararla.
Riesgo de lesiones personales: Debido a los bordes filosos, manipúlelo con cuidado.
El incumplimiento de estas instrucciones puede ocasionar la muerte, lesiones corporales graves y
daños a la propiedad.
ADVERTENCIA
RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o
rdidas de ningún tipo que puedan surgir por la instalación, manipulacn o uso inadecuado, descuidado o
negligente de este producto.
IMPORTANTE: Lea atentamente antes de instalar la luminaria. Conserve estas instrucciones para tenerlas como
referencia futura.
AVISO: La luminaria puede dañarse y/o ser inestable si no se instala correctamente.
Nota: Las especificaciones y dimensiones están sujetas a cambios sin previo aviso.
Nota: Esta luminaria debe ser soportada por perfiles principales u otra estructura que sea capaz de soportar el peso
de la luminaria de 40 libras.
ATENCIÓN Departamento de recepción: Observe que la descripción real de la luminaria no carezca de piezas ni
presente daños notorios al momento de su entrega. Presente el reclamo directamente al transportista de carga (LTL).
Los reclamos por daños ocultos deben presentarse dentro de los 15 días posteriores a la entrega del producto. Se
debe guardar todo el material dañado, junto con el embalaje original.
1. Instrucciones de instalación de arriba a abajo
1. El cilindro viene completamente ensamblado cuando
se recibe. Para instalarlo, quite la tuerca n.º 8-32
ubicada en el centro de los dos (2) cables aeronáuticos.
La cubierta de resguardo puede caerse y dejar al
descubierto el tirante de montaje. (Figura1)
Figura 1.
Cubierta de
resguardo
Cables
aeronáuticos
Tuerca n.º 8-32
Tirante
Figura 2.
Tornillo n.º 8-32 (2)
Caja de derivación
Cables
aeronáuticos
Tuerca n.º 8-32
Tirante
2. Conecte el tirante de montaje a la caja de derivación
(de otras marcas) con dos (2) tornillos n.º 8-32.
(Figura2)
13
Instrucciones de instalación – Portfolio LuxWire™ Cylinders
13
Cooper Lighting Solutions IB520143ML Instrucciones de instalación
Figura 3.
Cubierta de
resguardo
Cables
aeronáuticos
Tuerca n.º 8-32
Tornillo n.º 8-32 (2)
Tirante
Cubierta de empalme
Controlador
3. Para las opciones con el controlador en la cubierta
de resguardo, existe una cubierta de empalme que
brinda una barrera al techo y el controlador está
sujeto al tirante de montaje. Realice las conexiones
al controlador siguiendo el código local y consultando
los diagramas de cableado mencionados en la sección
eléctrica. (Figura3)
4. En el caso de las opciones con controlador remoto,
conecte dicho controlador remoto a la caja de
derivación siguiendo las instrucciones proporcionadas
en el kit. Luego, conecte el arnés remoto al cable
aeronáutico usando los conectores de color naranja
adjuntos a los extremos de cada lado.
5. Una vez que el cableado esté completo, deslice la
cubierta de resguardo hacia el techo y asegúrela con
la tuerca n.º 8-32. Cierre los precintos que sujetan el
cable aeronáutico para que el cilindro pueda colgar
libremente.
6. Para regular la altura, use los accesorios de sujeción
de cable ubicados en el cuerpo del cilindro. Empuje el
accesorio de sujeción para pasar el cable a través de
este y asegúrese de cerrar los extremos para que el
cable no entre en contacto con ningún componente
metálico.
Caja de derivación
Figura 4.
Cubierta
de
resguardo
Cables
aeronáuticos
Tirante
Tornillo de cabeza
plana n.º 8-32 (2)
7. Se proporciona una funda termorretráctil para aislar los
cables del cuerpo del cilindro. Se recomienda colocar
dicha funda termorretráctil donde el cable entra en
contacto con el cilindro, junto al accesorio de conexión
del cable.
1.2. Instrucciones de instalación como iluminación
focal descendente
1. El cilindro viene completamente ensamblado cuando
se recibe. Para instalarlo, retire los dos (2) tornillos
de cabeza plana n.º 8-32 de la cubierta de resguardo
ubicada fuera de los dos (2) cables aeronáuticos.
La cubierta de resguardo puede caerse y dejar al
descubierto el tirante de montaje. (Figura4)
2. Conecte el tirante de montaje a la caja de derivación
(de otras marcas) con dos (2) tornillos n.º 8-32.
(Figura2)
3. Para las opciones con el controlador en la cubierta
de resguardo, existe una cubierta de empalme que
brinda una barrera al techo y el controlador está
sujeto al tirante de montaje. Realice las conexiones
al controlador siguiendo el código local y consultando
los diagramas de cableado mencionados en la sección
eléctrica. (Figura3)
14
Cooper Lighting Solutions IB520143ML Instrucciones de instalación
Instrucciones de instalación – Portfolio LuxWire™ Cylinders
4. En el caso de las opciones con controlador remoto,
conecte dicho controlador remoto a la caja de
derivación siguiendo las instrucciones proporcionadas
en el kit. Luego, conecte el arnés remoto al cable
aeronáutico usando los conectores de color naranja
adjuntos a los extremos de cada lado.
5. Una vez que el cableado esté completo, deslice la
cubierta de resguardo hacia el techo y asegúrela en
su lugar con dos (2) tornillos de cabeza plana n.º 8-32.
Cierre los precintos que sujetan el cable aeronáutico
para que el cilindro pueda colgar libremente.
6. Para regular la altura, la parte superior del cilindro debe
quitarse retirando cuatro (4) tornillos, luego use los
accesorios de conexión del cable ubicados en la parte
superior del cilindro. Empuje el accesorio de sujeción
para pasar el cable a través de este y asegúrese de
cerrar los extremos para que el cable no entre en
contacto con ningún componente metálico. Luego
vuelva a instalarlo en el cilindro.
Figura 5.
Figura 6.
Figura 7.
Figura 8.
Figura 9. Tornillo
Cable de conexión
a tierra de color
verde
Arandela de
seguridad
Perno del tornillo
del disipador de
calor
Borde
1. Retire el borde inferior del embalaje protector. Gire los
tres (3) clips laterales hacia afuera. (Figura 5) Retire el
motor del LED del embalaje protector.
2. Inserte el motor del LED en el conjunto del borde.
Alinee el terminal en el motor del LED con la ranura en
el conjunto del borde. (Figura 6)
3. Gire los tres (3) clips laterales para sujetar de manera
segura el conjunto del borde al motor del LED.
(Figura 7)
4. Enchufe la desconexión rápida de la luminaria en el
módulo. (Figura 8)
5. Encuentre la correa verde dentro del cilindro y
conéctela al disipador de calor mediante el tornillo y la
arandela de seguridad ubicada en el sobre adjunto a la
correa. (Figura 9)
15
Instrucciones de instalación – Portfolio LuxWire™ Cylinders
15
Cooper Lighting Solutions IB520143ML Instrucciones de instalación
Figura 10.
Receptor de
muelle de torsión
6. Para instalar el motor del LED y el conjunto del borde,
inserte los muelles de torsión en los receptores
correspondientes ubicados dentro del alojamiento.
(Figura 10)
NEGRO (LÍNEA) NEGRO (LÍNEA)
BLANCO
(NEUTRO)
BLANCO
(NEUTRO)
CONEXIÓN A TIERRA
AZUL
ROJO
PÚRPURA
ROSA*
NEGRO
LUZ LED
ROJO
DIAGRAMA DE
CABLEADO DEL
MÓDULO
OPCIÓN DE
REGULADOR
DE 0-10 V
(INSTALACIÓN
EN CAMPO)
REGULADOR
TRIAC A 120 VCA
O CONTROLADOR
DEL REGULADOR
DE 0-10 V A 120-
277 VCA
CONECTOR
CONECTOR
Limpieza
1. Para limpiar los bordes:
2. Limpie suavemente con un paño suave, limpio y seco
que no suelte pelusa para eliminar el polvo.
3. Limpie con una solución de detergente suave en un
paño suave y limpio para eliminar las huellas dactilares
y las manchas.
4. Enjuague con agua limpia y seque con un paño suave,
limpio y seco que no suelte pelusa.
Conexión eléctrica
Asegúrese de que no haya cables pelados expuestos por
fuera de las tuercas para cables.
1. Brinde el servicio eléctrico a la unidad del alojamiento
cilíndrico de acuerdo al "Código Eléctrico Nacional" o
a su código eléctrico local. El aislamiento del cable de
alimentación debe tener una clasificación de al menos
90°C.
2. Conecte los cables del terminal de alimentación a los
cables del terminal del alojamiento cilíndrico (entrada,
neutro y a tierra) en la luminaria, utilizando las tuercas
para cables del tamaño correcto. Tenga cuidado de no
dejar ningún conductor pelado fuera de los conectores
de la tuerca para cable.
3. Conecte el blanco con el blanco, el negro con el
negro y el verde (del suministro eléctrico) del lado de
la alimentación con el cable verde en la unidad del
alojamiento cilíndrico.
Diagramas de cableado
1. Para el controlador D010TR
2. Para el controlador D010TE
NEGRO (LÍNEA) NEGRO (LÍNEA)
BLANCO
(NEUTRO) BLANCO
(NEUTRO)
CONEXIÓN A TIERRA
NEGRO
ROJO
PÚRPURA
ROSA*
NEGRO
LUZ LED
ROJO
DIAGRAMA DE
CABLEADO DEL
MÓDULO
OPCIÓN DE
REGULADOR
DE 0-10 V
(INSTALACIÓN
EN CAMPO)
REGULADOR
DE FASE DE
SALIDA O
CONTROLADOR
DE REGULADOR
DE 0-10 V
CONECTOR
CONECTOR
3. Controlador DL3
NEGRO (LÍNEA)
BLANCO (COMÚN)
CONEXIÓN A TIERRA
NEGRO
ROJO
PÚRPURA
NARANJA
PÚRPURA/BLANCO
NEGRO
LUZ LED
ROJO
VERDE
REGULADOR TRIFILAR
(INSTALACIÓN EN
CAMPO SOLAMENTE)
REGULADOR DE
CONTROL DIGITAL
LUTRON ECOSYSTEM.
INSTALACIÓN EN
CAMPO SOLAMENTE
CONDUCTOR
LUTRON
(120V-277V)
CONECTOR
CONECTOR
DIAGRAMA DE
CABLEADO DEL MÓDULO
4. Para el controlador D010
NEGRO (LÍNEA) NEGRO (LÍNEA)
BLANCO
(NEUTRO)
BLANCO
(NEUTRO)
TIERRA
CONTROLADOR
DEL REGULADOR
DE 0-10 V
ROJO ROJO
AZUL
PÚRPURA
ROSA*
LUZ LED
NEGRO
DIAGRAMA DE
CABLEADO DEL MÓDULO
OPCIÓN DE
REGULADOR
DE 0-10 V
(INSTALACIÓN
EN CAMPO)
CONECTOR
CONECTOR
16
Cooper Lighting Solutions IB520143ML Instrucciones de instalación
Instrucciones de instalación – Portfolio LuxWire™ Cylinders
5. Para el controlador D5LT
NEGRO (LÍNEA)
BLANCO (COMÚN)
CONEXIÓN A TIERRA
AZUL
NEGRO NEGRO
PÚRPURA
PÚRPURA/BLANCO
LUZ LED
ROJO
ROJO
VERDE
DIAGRAMA DE
CABLEADO DEL MÓDULO
CONDUCTOR
TERMINALES
DEL REGULADOR
MARRÓN
DA
GRP 1
CONECTOR
CONECTOR
+
+
-
-
~
~
7. Para el controlador DE010
NEGRO (LÍNEA)
VERDE
BLANCO
(NEUTRO)
BLANCO
(NEUTRO) CONTROLADOR
DEL
REGULADOR
DE 0-10 V
NEGRO (LÍNEA)
NEGRO NEGRO
ROJO
PÚRPURA
ROSA*
LUZ LED
ROJO
DIAGRAMA DE
CABLEADO DEL MÓDULO
INSTALACIÓN
EN CAMPO DEL
REGULADOR
DE 0-10 V
CONECTOR
CONECTOR
8. Para el controlador DL2
CONECTOR
CONECTOR
NEGRO (DIM HOT)
BLANCO (COMÚN)
VERDE
TIERRA
ROJO ROJO
AZUL
NEGRO
LUZ LED
DIAGRAMA DE
CABLEADO DEL MÓDULO
CONDUCTOR DEL
REGULADOR DE
FASE DIRECTA
6. Para el controlador DMX*
CONNECTOR
CONNECTOR
ROJO
AZUL
ENTRADA + DMX (DE OTRAS MARCAS)
+
+
-
-
CONTROLADOR
DEL
REGULADOR
DMX (120-277)
ENTRADA + DMX
LED
DIAGRAMA DE
CABLEADO DE MÓDULO
MX EN PANTALLA
CONDUCTORA
EXISTE + DMX ENTRADA - DMX (DE OTRAS
MARCAS)
MX EN PANTALLA CONDUCTORA (DE OTRAS MARCAS)
DMX HACIA FUERA + (DE OTRAS MARCAS)
DMX HACIA FUERA - (DE OTRAS MARCAS)
DMX HACIA FUERA SHIELD (DE OTRAS
MARCAS)
BLANCO (COMÚN)
VERDE
CONEXIÓN A TIERRA
NEGRO (LÍNEA)
~ AZUL
~MARRÓN
GRUPO 1
ROJO
NEGRO
9. Para el controlador DLE
CONECTOR
CONECTOR
NEGRO (LÍNEA)
TIERRA
ROJO ROJO
AZUL
PÚRPURA
PÚRPURA NEGRO
LUZ LED
DIAGRAMA DE
CABLEADO DEL MÓDULO
BLANCO
(NEUTRO)
CONTROLADOR
DEL
REGULADOR
ECOSYSTEM
DE LUTRON
REGULADOR
ECOSYSTEM
NEGRO (LÍNEA)
BLANCO (NEUTRO)
Regulación
Los cilindros *D010 Portfolio pueden regularse con muchos
Portfolio pueden regularse con muchos reguladores de
cilindros *DL2 Portfolio pueden regularse con los controles
de fase directa bifilares Lutron. Los cilindros *D5LT Portfolio
pueden regularse con los controles compatibles Fifth Light y
DALI. Los cilindros *DMX Portfolio pueden regularse con los
controles compatibles DMX. Los cilindros *DE010 Portfolio
pueden regularse con controles de regulación de 0-10
de tensión de línea. Los cilindros *DLE Portfolio pueden
regularse con los controles digitales EcoSystem® de Lutron.
Para asegurarse de que cuenta con información actualizada
sobre la compatibilidad entre luminarias y reguladores,
remítase al sitio web de las luminarias LED Portfolio:
www.portfolio-lighting.com.
* Las edificaciones construidas antes de enero de 2022 pueden
casos, el instalador etiquetará el cable gris de la edificación como un
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2020 Cooper Lighting Solutions
All Rights Reserved
Printed in USA
Imprimé aux États-Unis
Impreso en los EE. UU.
Publication No. IB520143ML
November 10, 2021
Cooper Lighting Solutions is a
registered trademark.
All trademarks are property
of their respective owners.
Cooper Lighting Solutions est une
marque de commerce
déposée. Toutes les autres marques
de commerce sont la propriété de leur
propriétaire respectif.
Cooper Lighting Solutions es una
marca comercial
registrada. Todas las marcas
comerciales son propiedad de sus
respectivos propietarios.
Product availability, specifications,
and compliances are subject to
change without notice.
La disponibilité du produit, les
spécifications et les conformités
peuvent être modifiées sans préavis.
La disponibilidad de productos, las
especificaciones y los cumplimientos
están sujetos a cambio sin previo
aviso.
Warranties and Limitation of Liability
Please refer to www.cooperlighting.com/LightingWarrantyTerms for our terms and conditions.
Garanties et limitation de responsabilité
Veuillez consulter le site www.cooperlighting.com/LightingWarrantyTerms pour obtenir les conditions générales.
Garantías y Limitación de Responsabilidad
Visite www.cooperlighting.com/LightingWarrantyTerms para conocer nuestros términos y condiciones.
FCC Statement
Note: This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
Reorient or relocate the receiving antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet on a
circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV
technician for help.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
This device complies with ISED ICES Standard
Canada ICES-005 (A) / NMB-005 (A) or ICES-005
(B) / NMB-005 (B) depending on driver selected.
Any changes or modifications to this unit not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
Énoncé de la FCC
Remarque : Cet équipement a été mis à l’essai et
déclaré conforme aux limites établies pour un
dispositif numérique de classeA en vertu de
l’article15 des règlements de la FCC. Ces limites
sont conçues pour assurer une protection
raisonnable contre tout brouillage nuisible
lorsque l’équipement fonctionne dans un
environnement commercial. Cet équipement
produit, utilise et peut émettre de l’énergie
radioélectrique et, s’il n’est pas installé et utilisé
conformément aux instructions, il peut créer des
parasites nuisibles aux communications radio.
L’utilisation de cet équipement dans une
installation résidentielle est susceptible de
provoquer des interférences nuisibles, auquel
cas l’utilisateur devra corriger ces interférences à
ses propres frais.:
Réorienter ou déplacer l’antenne de réception.
Augmenter la distance entre l’équipement et
le récepteur.
Brancher l’équipement sur une prise indépen
dante du circuit d’alimentation du récepteur.
Consulter le détaillant ou un technicien de
radio/télévision compétent pour obtenir de
l’aide.
Cet appareil est conforme au chapitre 15 des
règlements FCC. La mise est oeuvre est sous
réserve des deux conditions suivantes : (1) Cet
appareil ne provoque pas de brouillage
nuisible, et (2) Cet appareil doit accepter toute
interférence reçue, notamment l’interférence
qui pourrait provoquer un fonctionnement
indésirable.
Cet appareil est conforme à la norme ISED
ICES Canada ICES-005 (A) / NMB-005 (A) ou
ICES-005 (B) / NMB-005 (B) selon le pilote
sélectionné.
Toute modification apportée à cet appareil non
expressément approuvée par la partie respons-
able de la conformité pourrait annuler l’autorité
de l’utilisateur à utiliser l’équipement.
Declaración de la FCC
Nota: Este equipo ha sido probado y cumple con
los límites para un dispositivo digital de Clase A,
de conformidad con la parte 15 de las Normas de
la FCC. Estos límites están diseñados para
proporcionar una protección razonable contra
interferencias perjudiciales cuando el equipo se
opera en un entorno comercial. Este equipo
genera, utiliza y puede emitir energía de
radiofrecuencia y, si no se instala y utiliza de
acuerdo con el manual de instrucciones, puede
causar interferencias perjudiciales en las
comunicaciones de radio. El funcionamiento de
este equipo en un área residencial puede causar
interferencias perjudiciales, en cuyo caso el
usuario deberá corregir las interferencias por su
cuenta.
Reorientar o reubicar la antena receptora.
Aumentar la separación entre el equipo y el
receptor.
Conectar el equipo a una toma de corriente en
un circuito diferente al que está conectado el
receptor
Consultar con el distribuidor o con un técnico
de radio/TV experimentado para obtener
ayuda.
Este dispositivo cumple con parte 15 de las
reglas de FFC. SU operación está sujeta a las
siguiente condiciones: (1) Este dispositivo no
puede causar interferencia dañina, y (2) este
dispositivo puede recibir interferencia,
incluyendo aquella que puede causar una
operación no deseada del dispositivo.
Este dispositivo cumple con la norma canadiense
ISED ICES ICES-005 (A) / NMB-005 (A) o ICES-005
(B) / NMB-005 (B) según el controlador
seleccionado.
Cualquier cambio o modificación a esta unidad
no aprobada expresamente por la parte
responsable del cumplimiento podría anular la
autoridad del usuario para operar el equipo.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Cooper Lighting Solutions IB520143ML Manuel utilisateur

Taper
Manuel utilisateur