NOT
E
When all the four green lights (38) turn on, it shows that the battery is fully charged.
When only the last green light (38) is on, and begins to flash, suggest charging the
battery, for the machine will stop automatically after a few minutes.
After the last green light (38) turns off, and the red light (39 and 40) begins to flash,
the machine will stop automatically after a few seconds. (Refer to the steps related in
the maintenance section).
CAUTION!
Do not use the machine when the power supply of the battery is insufficient, so as
to avoid damaging the battery and shortening the life of the battery.
TANK EMPTYING
W
hen recovery tank is full, a float in the automatic float turn-off device (36) will block the inlet
connecting to the vacuum pump. Through a sudden increase of noise from the vacuum pump, it can
be considered that the vacuum pump is already overloaded and an immediate draining of the
wastewater is needed.
CAUTION!
If the vacuum pump is suddenly turned off (e.g. because the machine is suddenly
moved resulting in an activation of the float), and if a resumption of operation is
needed, please perform the following steps: press the power switch (41 and 42) to
turn off the power and the vacuum pump, and open the recovery tank cover (25) to
check if the float in the float filter has returned to the water surface. Then close
recovery tank cover (25), and press the power switch (41 and 42) to turn on the
power and the vacuum pump.
When the recovery tank is fully filled with wastewater, follow the following steps to drain it all.
Recovery tank emptying
1. Turn off the machine.
2. By using the squeegee handle (14), lift the squeegee.
3. Move the machine to a dedicated dump site.
4. Grasp the handlebar (2) and gently incline the machine
backward until the guide wheel touches the floor. (For
docking of the machine please refer to the procedures in the
stopping of the machine section.)
5. Take off the draining hose from the fixation clip, bend the top
end of draining hose (as shown in A, Figure 13), and then
open the cover of draining hose, lower draining hose to a low
level or on the ground to drain the water. Alternatively,
directly place draining hose to a low position or on the ground
to make the water outlet face downward (as show in B, Figure 13), and then twist open the water
draining lid to drain off the wastewater in the tank. After draining is completed, use pure water to
cleanse the inside of recovery tank.
CAUTION!
When draining the wastewater, the vacuum tube for waste must be folded or
lowered to a lower position (as shown in Figure 13 A or B), and then open the lid of
the vacuum tube for waste to drain the water. Do not make the outlet of the vacuum
tube for waste face upward to drain the water vertically. This is to avoid wastewater
spilling onto the operator.
Solution tank emptying
6. Complete Steps 1 to 4.
7. As shown in Figure 14, turn open the lid of Solution tank (A) anticlockwise along direction C, and
drain Solution tank completely. Use pure water to cleanse the inside of Solution tank. When work
is completed, turn tight the lid of Solution tank (A) clockwise in direction B.