United States Stove Company AP5622 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
© 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
Owners Instruction and Operation Manual
U.S. Environmental Protection Agency
Certied to comply with 2020 particulate
emissions standards.
SAFETY NOTICE: If this heater is not properly installed, a house re may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
re ofcials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Could Void Your Warranty!
Save These Instructions In A Safe Place For Future Reference.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
Model Number:
853931D-0606M
AP5622
R
Report Number: F22-782
Certied to ASTM E1509-12 (2017), and
Certied to CAN/ULC S627:2021 Mobile
Home / Transportable Building Approved
2
© 2023 United States Stove Company
For Customer Service, please call:
1-800-750-2723 Ext 5050 or;
Text to 423-301-5624 or;
Email us at:
customerservice@usstove.com
Note: Register your product online
at www.usstove.com or download
the free app today. This app is
available only on the App Store for
iPhone and iPad. Search US Stove.
Save your receipt with your records
for any claims.
Your pellet stove has been safety tested and listed to ASTM E1509-12 (2017) and ULC-S627-00. This manual
describes the installation and operation of the pellet stove. This heater meets the 2020 U.S. Environmental
Protection Agency’s emission limits for wood-heaters sold after May 15, 2020. Under specic EPA test
conditions burning wood pellet fuel this heater has been shown to deliver heat at a rate of 32,591 to 13,640
Btu/hr. This heater achieved a particulate emissions rate of 1.5 g/hr when tested to method ASTM E 2779 /
EPA Method 28R and 76% efciency.
INTRODUCTION
Heating Specications
Fuel Burn Rate* (lowest setting) 2.1-5 lbs/hr (0.97 -
2.26 kg/hr) * Pellet size may effect the actual rate of fuel
feed and burn times. Fuel feed rates may vary
by as much as 20%. Use PFI listed fuel for best
results.
Burn Time (lowest setting) 80 hrs.
Hopper Capacity 170lbs. (77kg)
Flue Size 3” or 4”
Electrical Specications
Electrical Rating 110-120 Volts AC, 60 HZ, 3.0 Amps
Watts (operational) 175 (approx.)
Watts (igniter running) 425 (approx.)
Dimensions
Overall: Height x Width X Depth 40” (1003mm) X 24” (610mm) X 30” (762mm)
WARNING:
IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL.
© 2023 United States Stove Company
3
INSTALLATION CHECKLIST
Your Wood Stove should be installed by a qualied installer only. An NFI qualied Installer can be found at
www.ncertied.org/public/nd-an-n-pro/
CUSTOMER SERVICE
1-800-750-2723 ext 5050
Text to 423-301-5624
Email to: Customerservice@usstove.com
COMMISSIONING CHECKLIST
This checklist is to be completed in full by the qualied person who installs this unit. Keep this page for
future reference.
Failure to install and commission according to the manufacturer’s instructions and complete this checklist
will invalidate the warranty.
Please Print
Customer Name: Telephone Number:
Address:
Model:
Serial Number:
Installation Company Name: Phone Number:
Installation Technician’s Name: License Number:
DESCRIPTION OF WORK
Location of installed appliance: _________________________________________________________________________
Venting System: New Venting System Yes No If yes, Brand __________________________________
If no, Date of inspection of existing venting system: ______________________________________________________
COMMISSIONING
Conrm Hearth Pad Installation as per Installation Instructions ..............................................................................................
Conrm proper placement of internal parts ...........................................................................................................................................
Check soundness of door gasket and door seals .................................................................................................................................
Conrm clearances to combustibles as per installation instructions in this manual .................................................
Check the operations of the air controls ....................................................................................................................................................
Conrm the venting system is secure and sealed ...............................................................................................................................
Conrm the stove starts and operates properly ....................................................................................................................................
Check to ensure a CO alarm is installed as per local building codes and is functional .............................................
Explain the safe operation, proper fuel usage, cleaning, and routine maintenance requirements .................
Declaration of Completion: As the qualied person responsible for the work described above, I conrm that
the appliance as associated work has been installed as per manufacturers instructions and following any
applicable building and installation codes.
Signed: ___________________________________Print Name: ______________________________ Date: _____________
Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE
4
© 2023 United States Stove Company
INSTALLATION
SAFETY NOTICE
IF THIS STOVE IS NOT PROPERLY INSTALLED,
A HOUSE FIRE MAY RESULT. TO REDUCE THE
RISK OF FIRE, FOLLOW THE INSTALLATION
INSTRUCTIONS.
CONTACT YOUR LOCAL BUILDING OFFICIALS
TO OBTAIN A PERMIT AND INFORMATION
ON ANY ADDITIONAL INSTALLATION
RESTRICTIONS OR INSPECTION
REQUIREMENTS IN YOUR AREA.
DO NOT PLACE CLOTHING OR OTHER
FLAMMABLE ITEMS ON OR NEAR THIS
STOVE.
NEVER USE GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR ’FRESHEN UP’ A FIRE IN THIS
STOVE. KEEP ALL SUCH LIQUIDS WELL
AWAY FROM THE STOVE WHILE IT IS IN USE.
THIS APPLIANCE IS A FREESTANDING
HEATER. IT IS NOT INTENDED TO BE
ATTACHED TO ANY TYPE OF DUCTING. IT
IS NOT A FURNACE. DO NOT CONNECT THIS
UNIT TO ANY AIR DISTRIBUTION DUCT OR
SYSTEM. THIS APPLIANCE IS NOT INTENDED
FOR COMMERCIAL USE.
INSTALL VENT AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
YOUR STOVE REQUIRES PERIODIC
MAINTENANCE AND CLEANING (SEE
”MAINTENANCE”). FAILURE TO MAINTAIN
YOUR STOVE MAY LEAD TO IMPROPER
AND/OR UNSAFE OPERATION.
A POWER SURGE PROTECTOR IS REQUIRED.
THIS UNIT MUST BE PLUGGED INTO A 110
- 120V, 60 HZ GROUNDED ELECTRICAL
OUTLET. DO NOT USE AN ADAPTER
PLUG OR SEVER THE GROUNDING PLUG.
DO NOT ROUTE THE ELECTRICAL CORD
UNDERNEATH, IN FRONT OF, OR OVER
THE HEATER. DO NOT ROUTE THE CORD IN
FOOT TRAFFIC AREAS OR PINCH THE CORD
UNDER FURNITURE.
CAUTION:
BURNING FUEL CREATES CARBON MONOXIDE
AND CAN BE HAZARDOUS TO YOUR HEALTH
IF NOT PROPERLY VENTED.
ATTENTION:
A WORKING SMOKE DETECTOR MUST BE
INSTALLED IN THE SAME ROOM AS THIS
PRODUCT.
INSTALL A SMOKE DETECTOR ON EACH
FLOOR OF YOUR HOME; INCASE OF
ACCIDENTAL FIRE FROM ANY CAUSE IT
CAN PROVIDE TIME FOR ESCAPE.
THE SMOKE DETECTOR MUST BE INSTALLED
AT LEAST 15 FEET (4,57 M) FROM THE
APPLIANCE IN ORDER TO PREVENT UNDUE
TRIGGERING OF THE DETECTOR WHEN
RELOADING.
CAUTION:
USE OF OUTSIDE AIR IS NOT REQUIRED FOR
THIS UNIT.
DO NOT UNPLUG THE STOVE IF YOU
SUSPECT A MALFUNCTION. TURN THE ON/
OFF SWITCH TO ”OFF’ AND CONTACT YOUR
DEALER.
THE HEATER WILL NOT OPERATE DURING
A POWER OUTAGE. IF A POWER OUTAGE
DOES OCCUR, CHECK THE HEATER FOR
SMOKE SPILLAGE AND OPEN A WINDOW IF
ANY SMOKE SPILLS INTO THE ROOM.
NEVER BLOCK FREE AIRFLOW THROUGH
THE OPEN VENTS OF THE UNIT.
US Stove highly recommends your stove be installed
by a qualied NFI (US) or WETT (Canada) technician.
To nd the nearest qualied installer, go to:
https://ncertied.org,
https://www.wettinc.ca/
© 2023 United States Stove Company
5
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
1. Pull the factory installed wires out of the top of
the stove. There will be two wire harnesses, as
shown.
2. Unpack the top mount controls and ensure that
the wiring harness shown is attached securely.
3. Connect the factory installed wiring harnesses
to the control panel as shown.
4. Secure the control panel to the top of the stove
with two sheet metal screws.
6
© 2023 United States Stove Company
INSTALLATION
INSTALLATION OPTIONS
Freestanding Unit - supported by pedestal/legs
and placed on a non-combustible oor surface
in compliance with clearance requirements for a
freestanding stove installation.
Alcove Unit - supported by pedestal/legs and
placed on a non-combustible oor surface in
compliance with clearance requirements for an
alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This unit must be installed on a non-combustible
oor surface. If a oor pad is used, it should be
certied or equal. The oor pad or non-combustible
surface should be large enough to extend a
minimum of 6” (153 mm) in front, 6” (153 mm) on
each side, and 1” (26 mm) behind the stove. Floor
protection must extend under and 2” (51 mm) to
each side of the chimney tee for an interior vertical
installation. A Floor Protector of 1” (26 mm) thick is
recommended for this installation.
D
B
C
B
A
A Rear (through wall) 1” 25 mm
BSide 6” 152 mm
C Front 6” 152 mm
DRear (interior
vertical) 2” 50 mm
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home/
transportable building, and alcove applications
in accordance with the clearances given in this
manual. NOTE: The distance on the side of your
pellet stove may need to be greater than the
minimum required clearance for suitable access to
the control panel. For safety reasons, please adhere
to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be
done by means approved by a regulatory authority.
F
G
E
H
F
G
J
J
J
J
K
PARALLEL
E Backwall to unit 9.5” 241 mm
FSidewall to ue 14” 356 mm
GSidewall to top
edge of unit 8” 203 mm
HBackwall to ue 3” 76.2mm
CORNER JAdjacent wall to
unit 8” 203 mm
ALCOVE K Alcove depth 36” 914 mm
OUTSIDE AIR SUPPLY
(OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME/
TRANSPORTABLE BUILDING)
Depending on your location and home
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home/transportable
© 2023 United States Stove Company
7
building. You can purchase the 69FAK through your
heater dealer. Installation instructions are supplied
with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT
CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE,
AS WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the
oor.
Fresh Air
Intake
Exhaust
Pipe
WARNING! DO NOT INSTALL IN SLEEPING
ROOM.
CAUTION! THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME/TRANSPORTABLE
BUILDING FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME/
TRANSPORTABLE BUILDING, THE STOVE
MUST BE GROUNDED DIRECTLY TO THE STEEL
CHASSIS AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements, mobile home/transportable building
installations must meet the following requirements:
This stove must be securely fastened to the oor
of the mobile home/transportable building using
two 1/4” lag bolts that are long enough to go
through both a hearth pad, if used, and the oor
of the home.
The heater must be electrically grounded to the
steel chassis of the mobile home/transportable
building with 8 GA copper wire using a serrated
or star washer to penetrate paint or protective
coating to ensure grounding.
Vent must be 3 or 4-inch “PL” Vent and must
extend a minimum or 36” (914 mm) above the roof
line of the mobile home/transportable building
and must be installed using a certied ceiling re
stop and rain cap.
When moving your mobile home/transportable
building, all exterior venting must be removed
while the mobile home/transportable building is
being relocated. After relocation, all venting must
be reinstalled and securely fastened.
Outside Air is mandatory for mobile home/
transportable building installation. See Outside
Air Supply section and your dealer for purchasing.
Check with your local building ofcials as other
codes may apply.
VENTING REQUIREMENTS
WARNING:
INSTALL VENT AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
DO NOT CONNECT THE PELLET VENT TO A
VENT SERVING ANY OTHER APPLIANCE OR
STOVE.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
The following installation guidelines must be
followed to ensure conformity with both the safety
listing of this stove and to local building codes. Do
not use makeshift methods or compromise in the
installation.
IMPORTANT:
THIS UNIT IS EQUIPPED WITH A NEGATIVE
DRAFT SYSTEM THAT PULLS AIR THROUGH
THE BURN POT AND PUSHES THE EXHAUST
OUT OF THE DWELLING. IF THIS UNIT IS
CONNECTED TO A FLUE SYSTEM OTHER THAN
THE WAY EXPLAINED IN THIS MANUAL, IT
WILL NOT FUNCTION PROPERLY.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical
pipe outside the home. This will create some natural
draft to reduce the possibility of smoke or odor
during appliance shutdown and keep exhaust from
causing a nuisance or hazard by exposing people
or shrubs to high temperatures. The maximum
INSTALLATION
8
© 2023 United States Stove Company
recommend vertical venting height is 12-feet for
3-inch type “PL vent. Total length of horizontal
vent must not exceed 4-feet. This could cause back
pressure. Use no more than 180 degrees of elbows
(two 90-degree elbows, or two 45-degree and one
90-degree elbow, etc.) to maintain adequate draft.
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the
appliance up through the chimney. The amount of
draft in your chimney depends on the length of the
chimney, local geography, nearby obstructions and
other factors. Too much draft may cause excessive
temperatures in the appliance. Inadequate
draft may cause backpufng into the room and
plugging’ of the chimney. Inadequate draft will
cause the appliance to leak smoke into the room
through appliance and chimney connector joints.
An uncontrollable burn or excessive temperature
indicates excessive draft. Take into account the
chimney’s location to ensure it is not too close
to neighbours or in a valley which may cause
unhealthy or nuisance conditions.
PELLET VENT TYPE
A certied 3-inch or 4-inch type “PL” pellet vent
exhaust system must be used for installation and
attached to the pipe connector provided on the
back of the stove (use a 3-inch to 4-inch adapter
for 4-inch pipe). The connection at the back of
the stove must be sealed using Hi-Temp RTV. Use
a 4-inch vent if the vent height is over 12-feet or if
the installation is over 2,500 feet above sea level.
We recommend the use of Simpson Dura-Vent® or
Metal-Fab® pipe (if you use other pipes, consult your
local building codes and/or building inspectors). Do
not use Type-B Gas Vent pipe or galvanized pipe
with this unit. The pellet vent pipe is designed to
disassemble for cleaning and should be checked
several times during the burning season. The pellet
vent pipe is not furnished with the unit and must
be purchased separately.
PELLET VENT INSTALLATION
The installation must include a clean-out tee to
enable collection of y ash and to permit periodic
cleaning of the exhaust system. 90-degree elbows
accumulate y ash and soot thereby reducing
exhaust ow and performance of the stove. Each
elbow or tee reduces draft potential by 30% to 50%.
All joints in the vent system must be fastened by
at least 3 screws, and all joints must be sealed with
Hi-Temp RTV silicone sealant to be airtight. The
area where the vent pipe penetrates to the exterior
of the home must be sealed with silicone or other
means to maintain the vapor barrier between the
exterior and the interior of the home. Vent surfaces
can get hot enough to cause burns if touched by
children. Noncombustible shielding or guards may
be required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-
enclosed area, such as; carport, garage, attic,
crawl space, under a sun deck or porch, narrow
walkway, or any other location that can build up
a concentration of fumes. Termination in one of
these areas can also lead to unpredictable pressure
situations with the appliance, and could result
in improper performance and/or malfunction.
The termination must exhaust above the outside
air inlet elevation. The termination must not be
located where it will become plugged by snow or
other materials. Do not terminate the venting into
an existing steel or masonry chimney.
VENT TERMINATION CLEARANCES
A. Minimum 4-foot (1.22m) clearance below or
beside any door or window that opens.
B. Minimum 1-foot (0.3m) clearance above any
door or window that opens.
C. Minimum 3-foot (0.91m) clearance from any
adjacent building.
INSTALLATION
© 2023 United States Stove Company
9
D. Minimum 7-foot (2.13m) clearance from any
grade when adjacent to public walkways.
E. Minimum 2-foot (0.61m) clearance above any
grass, plants, or other combustible materials.
F. Minimum 3-foot (0.91m) clearance from an
forced air intake of any appliance.
G. Minimum 2-foot (0.61m) clearance below eves
or overhang.
H. Minimum 1-foot (0.3m) clearance horizontally
from combustible wall.
I. Must be a minimum of 3 foot (0.91m) above the
roof and 2 foot (0.61m) above the highest point
or the roof within 10 feet (3.05m).
Determining where to install your new pellet stove
heater. To get the most efcient use of re-circulated
heat, you should consider a room that is centrally
located within your home. Choose a room that
is large and open. It is Extremely Important to
maintain proper clearances from any combustible
surfaces or materials in the room where your heater
will be located. You can nd proper clearance
measurements in this manual and on the rating
label of your pellet stove. The pellet stove can be
vented through an exterior wall or into an existing
masonry or metal chimney if “PL” vent pipe is used
throughout existing chimney. Venting can pass
through the ceiling and roof if approved pipe is
used. Where passage through a wall, or partition of
combustible construction is desired, the installation
must conform to CAN/CSA-B365.
WARNING:
DO NOT OBTAIN COMBUSTION AIR FROM
THE ATTIC, GARAGE OR ANY OTHER
UNVENTILATED AREA. YOU MAY OBTAIN
COMBUSTION AIR FROM A VENTILATED
CRAWL SPACE.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER HEATER, FURNACE
OR APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
ONLY USE APPROVED MATERIAL FOR
INSTALLATION, FAILURE TO DO SO MAY
RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
This appliance is certied for use with listed 3 inch
or 4 inch “PL pellet venting products. The use of
other components other than stated herein could
cause bodily harm, heater damage, and void your
warranty.
HORIZONTAL EXHAUST VENT
INSTALLATION
1. Locate your pellet stove in a location which
meets the requirements of this manual, but
in an area where it does not interfere with the
house framing, wiring, etc.
2. Install a non-combustible hearth pad
underneath the pellet stove. This pad should
extend at least 6” (152 mm) in front of the unit.
3. Place the pellet stove approximately 15” (381
mm) away from the interior wall.
4. Locate the center of the exhaust pipe of your
unit. This point should then be extended to
the interior wall of your house. Once you have
located the center point, on the interior wall, cut
a 7” (175 mm) diameter hole through the wall.
5. The next step is to install the wall thimble, refer
to the instructions which come with the wall
thimble for this step.
6. Install the appropriate length of exhaust vent
pipe into the wall thimble. See steps 11 and 12
when determining the correct length of exhaust
vent to use.
7. Outside Fresh Air is Mandatory when
installing this pellet stove room heater
in airtight homes and mobile home/
transportable buildings. Be sure that the
outside air vent has an approved cap on it
to prevent rodents from entering. Be sure
to install in location that won’t become
blocked with snow, etc.
8. Connect the exhaust vent pipe to the exhaust
outlet of your pellet stove.
9. Secure all vent joint connections with 3 screws.
Seal the exhaust vent joint connections with
high temperature silicone sealant.
10. Push the unit straight back to the interior
wall, being sure to maintain the minimum
clearances to combustibles 2” (51 mm) to the
back of the unit. Seal the annular space of the
wall thimble and around the vent pipe with
high temperature silicone sealant.
11. The exhaust vent pipe must extend at least 12”
INSTALLATION
10
© 2023 United States Stove Company
(300 mm) out past the exterior wall. Seal the
annular space of the wall thimble and around
the vent pipe with high temperature silicone
sealant.
12. Install an approved horizontal termination cap or
if necessary install a 90° elbow and appropriate
length of vertical venting. An approved vertical
vent cap is recommended.
THROUGH THE WALL INSTALLATION
(RECOMMENDED INSTALLATION)
Non-Combustable
Floor Pad
Clean-Out
Cover
Tee
Wall
Thimble
Pipe
Adapter
Exhaust Motor
Adapter
3’-0” (min) Vertical Pipe
Support
Bracket
Termination
Cap
90° Elbow
TO STOVE
Canadian installations must conform to CAN/
CSA-B365. To vent the unit through the wall,
connect the pipe adapter to the exhaust motor
adapter. If the exhaust adapter is at least 18” (457
mm) above ground level, a straight section of
pellet vent pipe can be used through the wall.
Your heater dealer should be able to provide you
with a kit that will handle most of this installation,
which will include a wall thimble that will allow
the proper clearance through a combustible
wall. Once outside the structure, a 3” (76 mm)
clearance should be maintained from the outside
wall and a clean out tee should be placed on the
pipe with a 90-degree turn away from the house.
At this point, a 3ft (0.91m) (minimum) section of
pipe should be added with a horizontal cap, which
would complete the installation. A support bracket
should be placed just below the termination cap
or one every 4ft (1.22m) to make the system more
stable. If you live in an area that has heavy snowfall,
it is recommended that the installation be taller
than 3ft (0.91m) to get above the snowdrift line.
This same installation can be used if your heater is
below ground level by simply adding the clean-out
section and vertical pipe inside until ground level is
reached. With this installation you have to be aware
of the snowdrift line, dead grass, and leaves. We
recommend a 3ft (0.91m) minimum vertical rise on
the inside or outside of the house. The “through the
wall” installation is the least expensive and simplest
installation. Never terminate the end vent under a
deck, in an alcove, under a window, or between two
windows. We recommend Simpson Dura-Vent® or
Metal-Fab® kits.
THROUGH THE ROOF/CEILING
INSTALLATION
When venting the heater through the ceiling, the
pipe is connected the same as through the wall,
except the clean-out tee is always on the inside
of the house, and a 3” (76 mm) adapter is added
before the clean-out tee.
You must use the proper ceiling support
anges and roof ashing (supplied by the pipe
manufacturer; follow the pipe manufacturer’s
directions). It is important to note that if your
vertical run of pipe is more than 12ft (3.7m), the
pellet vent pipe size should be increased to 4” (102
mm) in diameter.
Do not exceed more than 4ft (1.22m) of pipe on a
horizontal run and use as few elbows as possible. If
an offset is required, it is better to install 45-degree
elbows rather than 90-degree elbows.
IMPORTANT:
IF YOU ARE INSTALLING YOUR PELLET STOVE
AS A REPLACEMENT TO AN EXISTING WOOD
STOVE, YOU CAN INSTALL YOUR PELLET
STOVE USING THE EXISTING CLASS A 6”
VENTING SYSTEM.
INSTALLATION
© 2023 United States Stove Company
11
INSTALLATION
VENTING YOUR PELLET STOVE INTO
AN EXISTING CLASS A 6” CHIMNEY
SYSTEM
1. You must have the existing chimney system
cleaned and/ or inspected by a qualied
chimney sweep before proceeding with the
installation of your pellet stove.
2. To the right is an example of an installation
using part number 860001, 3-6” transition into
6” connector pipe. The illustration is only an
example. Please conform to any local building
codes or regulations having jurisdiction before
you have a qualied installer proceed with this
installation.
WARNING:
YOU MAY WANT TO LOCATE ANY UTILITIES
OR OBSTACLES INSIDE THE WALL BEFORE
ATTEMPTING THIS INSTALL. MAKE SURE TO
KEEP IN MIND YOUR UNIT’S CLEARANCE
REQUIREMENTS.
1. Mark the area and then cut the wall for vent
installation if needed.
2. Install the wall thimble as specied by the
manufacturer. (wall thimble sold separately)
3. Install venting.
Existing Class A
6” Chimney System
3” PL Vent
Clean Out Tee
Support
Bracket
Ceiling
Support
3” to 6” Pipe
Adapter
TO STOVE
INSTRUCTIONS SPECIFIC FOR CANADIAN
INSTALLATIONS
Do not obstruct the space under the heater and do
not obstruct the combustion air openings.
Refer to the chimney manufacturer’s instructions
for disassembling the chimney/venting for
transportation of a transportable building.
The parts or materials to be employed for ember
protectors and the minimum areas to be covered
and their relation to the space heater, as well as
the notice: “In Canada, to comply with CSA B365,
Installation Code for Solid-Fuel-Burning Appliances
and Equipment, any combustible covering beneath
the appliance and/or within the area extending
horizontally at least 450 mm (18 in) beyond the
appliance on any side equipped with a door, and at
least 200 mm (8 in) beyond the appliance on other
sides, shall be protected by a continuous, durable,
non-combustible pad that will provide ember
protection. The 450 mm (18 in) ember protection
required on any side with a door shall extend for
the full width of the appliance plus the 200 mm (8
in) required on each side of the appliance without a
door. Where an appliance is installed less than 200
mm (8 in) from a wall, the ember pad need only
extend to the base of the wall. An ember pad shall
not be placed on top of a carpet unless the pad is
structurally supported to prevent displacement
and distortion.
If this appliance is installed in a transportable
building, removal of the chimney/venting is
required for transportation of the building.
DO NOT INSTALL IN AN ALCOVE
12
© 2023 United States Stove Company
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
OPERATION INSTRUCTIONS
PANEL / REMOTE CONTROLS
The operation of this appliance can be controlled
from the panel located on the side of the stove and/
or by the remote control. The control functions are
as follows:
A. On/Off Switch
When pushed, the stove will automatically ignite.
No other re starter is necessary. The igniter
will stay on for at least 10 and up to 12 minutes,
depending on when Proof of Fire is reached. The
re should start in approximately 5 minutes.
After pushing the “On/Off button, the auger
motor is on for 3.5 minutes, off for 1 minute. During
the remainder of the start-up period, the auger
motor operates on the heat range “1” setting.
During start up the heat level advance (Up and
Down keys) will change the heat range indicator
level accordingly, but there is no change in the
stoves operating conditions until start-up is
completed.
During start-up ignition must occur within 12
minutes or the stove will error out and show E3.
During the start-up phase, the Mode key does not
function.
B. Heat Range Arrow Buttons
These buttons when pushed will set the pellet
feed rate, hence the heat output or heat range
of your stove. When using the hand-held remote
this function can be performed with the “Up/
Down” buttons.
The levels of heat output will incrementally
change on the bar graph starting from heat
range “1” to heat range “5”.
C. °C / °F Button
The °C / °F button changes the two digit display
from degrees Celsius to degrees Fahrenheit.
D. MODE (M/T) BUTTON
The Mode of the stove can be switched between
manual and controlled with a Thermostat.
Separate LEDs to the left of the two digit display
indicate the mode of operation – Manual or T-Stat.
The stove has to be in normal operation to be
switched from Manual to T-Stat mode.
Manual mode operates according to the 5 set
levels of feed on the bar graph from heat range
1” to heat range “5”.
T-Stat mode works as follows:
The stove has a built in Thermostat into the
controls of the appliance. The temperature sensor
for the T-Stat is located on the back of the stove
behind the display board.
Once the stove has gone into run mode the stove
can be switch into T-Stat mode.
The Up and Down Level / Temp Arrow buttons are
used to change the desired set-point temperature.
Once the desired temperature is reached the two
digit display will ash for four seconds and reset
to the actual room temperature.
Once the stove reaches within 3°F of the desired
temperature set point, it returns to the heat range
that the stove was set on before it was switched
to T-Stat mode (if the stove was running on heat
range “5” when switched to T-stat mode when
it gets within 3°F of the set point it will return to
heat range “5”).
Once the stove reaches the desired set-point, the
stove will drop to heat range “1”.
When room temperature drops below desired
set-point the stove will ramp back up until it
reaches the desired temperature.
NOTE:
Operation range of this
remote is within 16-1/12 ft.
of the appliance.
© 2023 United States Stove Company
13
WARNING:
DO NOT USE CHEMICALS OR FLUIDS TO
START THE FIRE - NEVER USE GASOLINE,
GASOLINE-TYPE LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR “FRESHEN
UP” A FIRE IN THIS STOVE. KEEP ALL SUCH
LIQUIDS WELL AWAY FROM THE STOVE
WHILE IT IS IN USE.
HOT WHILE IN OPERATION. KEEP
CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
This heater is designed to burn only PFI Premium
grade pellets. DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint
thinners, or asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt
water saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or
particleboard. The prohibition against burning
these materials does not prohibit the use of re
starters made from paper, cardboard, saw dust,
wax and similar substances for the purpose of
starting a re in an affected wood heater.
Burning these materials may result in release of
toxic fumes or render the heater ineffective and
cause smoke.
PROPER FUEL
ATTENTION:
THIS APPLIANCE IS DESIGNED FOR THE USE
OF PELLETIZED FUEL THAT MEET OR EXCEED
THE STANDARD SET BY THE PELLET FUEL
INSTITUTE (PFI).
Your pellet stove is designed to burn premium
hardwood pellets that comply with the Pellet Fuels
Institute (PFI) standard (minimum of 40 lbs density
per cubic ft, 1/4” to 5/16” diameter, length no greater
than 1.5”, not less than 8,200 BTU/lb, moisture under
8% by weight, ash under 1% by weight, and salt
under 300 parts per million). Pellets that are soft,
contain excessive amounts of loose sawdust, have
been, or are wet, will result in reduced performance.
Store your pellets in a dry place. DO NOT store the
fuel within the installation clearances of the unit
or within the space required for refuelling and ash
removal. Doing so could result in a house re. Do
not over re or use volatile fuels or combustibles,
doing so may cause a personal and property
damage hazards.
THIS STOVE IS APPROVED FOR BURNING
PELLETIZED WOOD FUEL ONLY ! Factory-approved
pellets are those 1/4” or 5/16” in diameter and not
over 1” long. Longer or thicker pellets sometimes
bridge the auger ights, which prevents proper
pellet feed. Burning wood in forms other than
pellets is not permitted. It will violate the building
codes for which the stove has been approved and
will void all warranties. The design incorporates
automatic feed of the pellet fuel into the re at
a carefully prescribed rate. Any additional fuel
introduced by hand will not increase heat output
but may seriously impair the stoves performance
by generating considerable smoke. Do not burn
wet pellets. The stove’s performance depends
heavily on the quality of your pellet fuel. Avoid pellet
brands that display these characteristics:
Excess Fines “Fines” is a term describing crushed
pellets or loose material that looks like sawdust or
sand. Pellets can be screened before being placed
in hopper to remove most nes.
Binders Some pellets are produced with
materials to hold the together, or “bind” them.
High ash content – Poor quality pellets will often
create smoke and dirty glass. They will create a
need for more frequent maintenance. You will
have to empty the burn pot plus vacuum the
entire system more often. Poor quality pellets
could damage the auger. We cannot accept
responsibility for damage due to poor quality
pellet.
OPERATION INSTRUCTIONS
14
© 2023 United States Stove Company
CAUTION:
KEEP FOREIGN OBJECTS OUT OF THE
HOPPER.
THE MOVING PARTS OF THIS STOVE ARE
PROPELLED BY HIGH TORQUE ELECTRIC
MOTORS. KEEP ALL BODY PARTS AWAY
FROM THE AUGER WHILE THE STOVE IS
PLUGGED INTO AN ELECTRICAL OUTLET.
THESE MOVING PARTS MAY BEGIN TO
MOVE AT ANY TIME WHILE THE STOVE IS
PLUGGED IN.
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none
of the air holes are plugged. Clean the rebox, and
then reinstall burn pot. Clean door glass if necessary
(a dry cloth or paper towel is usually sufcient).
Never use abrasive cleaners on the glass or door.
Check fuel in the hopper, and rell if necessary.
BUILDING A FIRE
Never use a grate or other means of supporting
the fuel. Use only the burn pot supplied with this
heater. Hopper lid must be closed in order for the
unit to feed pellets. During the start-up period:
Make sure the burn pot is free of pellets.
DO NOT open the viewing door.
DO NOT add pellets to the burn pot by hand.
NOTE: During the rst few res, your stove will
emit an odor as the high-temperature paint cures
or becomes seasoned to the metal. Maintaining
smaller res will minimize this. Avoid placing items
on the stovetop during this period because the paint
could be affected. Attempts to achieve heat output
rates that exceed heater design specications can
result in permanent damage to the heater.
OPTIMAL OPERATION
This pellet stove has been certied by the US EPA
to meet strict 2020 guidelines. To Insure this unit
produces the optimal minimal emissions, it is
critical to follow the following guidelines. To achieve
a “high burn” your stove should be set on setting
5 with the damper open. To achieve a “medium
burn” your stove should be set on setting 3 with
the damper 50% open. To achieve a “low burn” your
stove should be set on setting 1with the damper
closed. If the door is opened while the stove is in
operation it must be closed within 30 seconds or
the stove will shut down. If the stove shuts down
push the “On/Off” button to re-start your stove. The
stove will have to fully shut down and turn off before
you will be able to restart the stove.
IGNITOR
1. Fill hopper and clean burn pot.
2. Press the “On/Offbutton. Make sure the green
light comes on.
3. Adjust the feed rate to the desired setting by
pressing the “Heat Level Advance” button.
If the re doesn’t start in 12 minutes, press “On/Off”,
wait a few minutes, clear the burn pot, and start the
procedure again.
OPENING DOOR
CAUTION:
DO NOT OPERATE YOUR STOVE WITH
THE VIEWING DOOR OPEN. THE AUGER
WILL NOT FEED PELLETS UNDER THESE
CIRCUMSTANCES AND A SAFETY CONCERN
MAY ARISE FROM SPARKS OR FUMES
ENTERING THE ROOM.
THE DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
If the door is opened while the stove is in operation
it must be closed within 30 seconds or the stove
will shut down. If the stove shuts down push the
“On/Off” button to re-start your stove. The stove will
have to fully shut down and turn off before you will
be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not
come on until the stove’s heat exchanger warms up.
This usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The re goes out and the auger motor and blowers
will run until the stove cools. This will take 30 minutes
or longer depending on the heat remaining in
the appliance. After the stove components stop
OPERATION INSTRUCTIONS
© 2023 United States Stove Company
15
running all lights on the display will go out and the
two digit display will begin ashing “E3”.
REFUELLING
CAUTION:
THE HOPPER AND STOVE TOP WILL BE
HOT DURING OPERATION; THEREFORE,
YOU SHOULD ALWAYS USE SOME TYPE
OF HAND PROTECTION WHEN REFUELING
YOUR STOVE.
DO NOT TOUCH THE HOT SURFACES OF
THE STOVE. EDUCATE ALL CHILDREN ON
THE DANGERS OF A HIGH-TEMPERATURE
STOVE. YOUNG CHILDREN SHOULD BE
SUPERVISED WHEN THEY ARE IN THE SAME
ROOM AS THE STOVE.
NEVER PLACE YOUR HAND NEAR THE
AUGER WHILE THE STOVE IS IN OPERATION.
WE RECOMMEND THAT YOU NOT LET THE
HOPPER DROP BELOW 1/4 FULL.
WARNING:
KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum
low burn rate that must not be altered. It is against
federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent
with operating instructions in this manual.
SHUTDOWN PROCEDURE
WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the
“POWER” button on the display board. The green
light will turn back to red when the “POWER”
button is pushed. The auger motor will stop, and the
blowers will continue to operate until the internal
rebox temperatures have fallen to a preset level.
1. Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset
thermodisc. This safety switch has two functions.
A. To recognize an overheat situation in the stove
and shut down the fuel feed or auger system.
B. In case of a malfunctioning convection
blower, the high-temperature thermodisc will
automatically shut down the auger, preventing
the stove from overheating.
NOTE: On some units, once tripped, like a circuit
breaker, the reset button will have to be pushed
before restarting your stove. On other units the
thermodisc has no reset button and will reset
itself once the stove has cooled. The manufacturer
recommends that you call your dealer if this occurs
as this may indicate a more serious problem. A
service call may be required.
2. If the combustion blower fails, an air pressure
switch will automatically shut down the auger.
NOTE: Opening the stove door for more than
30 seconds during operation will cause enough
pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show
“E2” on the two digit display. The stove has to fully
shut down before restarting.
INTERIOR CHAMBERS
Burn Pot - Periodically remove and clean the burn
pot and the area inside the burn pot housing. In
particular, it is advisable to clean out the holes in
the burn pot to remove any build up that may
prevent air from moving through the burn pot
freely.
Heat Exchanger - There are two clean out plates
that need to be removed in order to clean the y
ash out of the heat exchanger. Open the door to
access the cleanouts located inside the rebox,
one on each side of the burnpot. The clean outs
are secured to the rebox with (2) 5/16” screws
each. Remove the clean outs and vacuum out
any accumulated ash. This should be done at
least once per month or more frequently if large
amounts of ash are noticed while cleaning or if
the stove does not seem to be burning properly.
Over time ash or dust may accumulate on the blades
of the circulation & exhaust fans. The fans should
be inspected, periodically, and if any accumulation
OPERATION INSTRUCTIONS
16
© 2023 United States Stove Company
is present vacuumed clean as the ash or dust can
impede the fans performance. It is also possible
that creosote may accumulate in the exhaust fan
therefore, this must be brushed clean. The exhaust
fan can be found behind the left side panel (facing
the front of the heater), the circulation fan can
be found behind the right side panel. To access
the igniter, remove the air inlet tube and cover (2
screws). The auger motor is located in the center
rear of the unit. Note: When cleaning, take care not
to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac
is designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE
THE CLEAN OUTS WILL RESULT IN POOR
PERFORMANCE OF THIS STOVE.
Clean-Out Plates
OPERATION INSTRUCTIONS
© 2023 United States Stove Company
17
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
MAINTENANCE
CAUTION:
FAILURE TO CLEAN AND MAINTAIN THIS
UNIT AS INDICATED CAN RESULT IN POOR
PERFORMANCE, SAFETY HAZARDS, FIRE,
AND EVEN DEATH.
NEVER PERFORM ANY INSPECTIONS,
CLEANING, OR MAINTENANCE ON A HOT
STOVE.
DISCONNECT THE POWER CORD BEFORE
PERFORMING ANY MAINTENANCE! NOTE:
TURNING THE ON/OFF SWITCH TO ”OFF”
DOES NOT DISCONNECT ALL POWER TO
THE ELECTRICAL COMPONENTS OF THE
STOVE.
DO NOT OPERATE STOVE WITH BROKEN
GLASS, LEAKAGE OF FLUE GAS MAY RESULT.
ATTEMPTS TO ACHIEVE HEAT OUTPUT
RATES THAT EXCEED HEATER DESIGN
SPECIFICATIONS CAN RESULT IN
PERMANENT DAMAGE TO THE HEATER.
CREOSOTE FORMATION, INSPECTION,
& REMOVAL
CAUTION:
THE EXHAUST SYSTEM SHOULD BE CHECKED
MONTHLY DURING THE BURNING SEASON FOR
ANY BUILD-UP OF SOOT OR CREOSOTE.
When any wood is burned slowly, it produces tar
and other organic vapors, which combine with
expelled moisture to form creosote. The creosote
vapors condense in the relatively cool chimney
ue or a newly started re or from a slow-burning
re. As a result, creosote residue accumulates
on the ue lining. When ignited, this creosote
makes an extremely hot re, which may damage
the chimney or even destroy the house. Despite
their high efciency, pellet stoves can accumulate
creosote under certain conditions. The chimney
connector and chimney should be inspected by
a qualied person annually or per ton of pellets
to determine if a creosote or y ash build-up has
occurred. If creosote has accumulated, it should
be removed to reduce the risk of a chimney re.
Inspect the system at the stove connection and
at the chimney top. Cooler surfaces tend to build
creosote deposits quicker, so it is important to
check the chimney from the top as well as from the
bottom. The creosote should be removed with a
brush specically designed for the type of chimney
in use. A qualied chimney sweep can perform this
service. It is also recommended that before each
heating season the entire system be professionally
inspected, cleaned and, if necessary, repaired. To
clean the chimney, disconnect the vent from the
stove.
FLY ASH
This accumulates in the horizontal portion of an
exhaust run. Though non-combustible, it may
impede the normal exhaust ow. It should therefore
be periodically removed.
ASH REMOVAL & DISPOSAL
CAUTION:
ALLOW THE STOVE TO COOL BEFORE
PERFORMING ANY MAINTENANCE OR
CLEANING. ASHES MUST BE DISPOSED IN A
METAL CONTAINER WITH A TIGHT FITTING LID.
THE CLOSED CONTAINER OF ASHES SHOULD
BE PLACED ON A NON-COMBUSTIBLE SURFACE
OR ON THE GROUND, WELL AWAY FROM ALL
COMBUSTIBLE MATERIALS, PENDING FINAL
DISPOSAL.
Remove the ashes periodically to avoid unnecessary
ash build up. Remove ashes when unit has cooled.
Ashes should be placed in a metal container with a
tight tting lid. The closed container of ashes should
be placed on a noncombustible oor or on the
ground, well away from all combustible materials,
pending nal disposal. If the ashes are disposed
of by burial in soil or otherwise locally dispersed,
they should be retained in the closed container
until all embers have been thoroughly cooled. The
container shall not be used for other trash or waste
disposal. If combined with combustible substances,
ashes and embers may ignite.
18
© 2023 United States Stove Company
MAINTENANCE
SMOKE & CO MONITORS
Burning wood naturally produces smoke and
carbon monoxide(CO) emissions. CO is a poisonous
gas when exposed to elevated concentrations
for extended periods of time. While the modern
combustion systems in heaters drastically reduce
the amount of CO emitted out the chimney,
exposure to the gases in closed or conned areas
can be dangerous. Make sure you stove gaskets
and chimney joints are in good working order and
sealing properly to ensure unintended exposure. It
is recommended that you use both smoke and CO
monitors in areas having the potential to generate
CO.
CHECK & CLEAN THE HOPPER
Check the hopper periodically to determine if there
is any sawdust (nes) that is building up in the feed
system or pellets that are sticking to the hopper
surface. Clean as needed.
DOOR & GLASS GASKETS
Inspect the main door and glass window gaskets
periodically. The main door may need to be removed
to have frayed, broken, or compacted gaskets
replaced by your authorized dealer. This unit’s door
uses a 3/4” diameter rope gasket.
BLOWER MOTORS
Clean the air holes on the motors of both the
exhaust and distribution blowers annually. Remove
the exhaust blower from the exhaust duct and
clean out the internal fan blades as part of your fall
start-up. If you have indoor pets your power motors
should be inspected monthly to make sure they
are free of animal hair build up. Animal hair build
up in blowers can result in poor performance or
unforeseen safety hazards.
PAINTED SURFACES
Painted surfaces may be wiped down with a damp
cloth. If scratches appear, or you wish to renew your
paint, contact your authorized dealer to obtain a
can of suitable high-temperature paint.
GLASS
We recommend using a high-quality glass cleaner.
Should a buildup of creosote or carbon accumulate,
you may wish to use 000 steel wool and water to
clean the glass. DO NOT use abrasive cleaners. DO
NOT perform the cleaning while the glass is HOT.
Do not attempt to operate the unit with broken
glass. Replacement glass may be purchased from
your U.S. Stove dealer. If the glass is broken, follow
these removal procedures:
1. Once the heater has cooled, remove the door
from the heater.
2. Remove the rope gasket from the door followed
by the nuts holding the glass retainer in place.
3. While wearing gloves, carefully remove any
loose pieces of glass from the door frame.
4. Replace the glass and gasket, making sure the
gasket runs the full perimeter of the glass edge.
5. Re-install the retainer and eight nuts and rope
gasket using high-temperature silicone to
adhere the gasket to the door.
6. Never use substitute materials for the glass.
DO NOT abuse the door glass by striking, slamming,
or similar trauma. Do not operate the stove with the
glass removed, cracked, or broken.
FALL START UP
Prior to starting the rst re of the heating season,
check the outside area around the exhaust and air
intake systems for obstructions. Clean and remove
any y ash from the exhaust venting system. Clean
any screens on the exhaust system and on the
outside air intake pipe. Turn all of the controls on
and make sure that they are working properly. This
is also a good time to give the entire stove a good
cleaning throughout.
SPRING SHUTDOWN
After the last burn in the spring, remove any
remaining pellets from the hopper and the auger
feed system. Scoop out the pellets and then run
the auger until the hopper is empty and pellets
stop owing (this can be done by pressing the “ON”
button with the viewing door open). Vacuum out
the hopper. Thoroughly clean the burn pot, and
rebox. It may be desirable to spray the inside of
the cleaned hopper with an aerosol silicone spray
if your stove is in a high humidity area. The exhaust
system should be thoroughly cleaned.
© 2023 United States Stove Company
19
MAINTENANCE
MAINTENANCE SCHEDULE
Use the following as a guide under average use
conditions. Gaskets around door and door glass
should be inspected and repaired or replaced when
necessary.
Daily Weekly Monthly or
as needed
Burn Pot Stirred Empty
Combustion
Chamber Brushed
Ashes Check Empty
Interior
Chambers Vacuumed
Combustion
Blower Blades
Vacuumed /
Brushed
Convection
Blower Impeller
Vacuumed /
Brushed
Vent System Cleaned
Gaskets Inspected
Glass Wiped Cleaned
Hopper (end of
season)
Empty &
Vacuumed
20
© 2023 United States Stove Company
TROUBLESHOOTING GUIDE
When your stove acts out of the ordinary, the rst reaction is to call for help. This guide may save time and
money by enabling you to solve simple problems yourself. Problems encountered are often the result of
only ve factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5)
factory defect. You can usually solve those problems related to 1 and 2. Customer service can solve problems
relating to 3, 4 and 5. Refer to diagrams in the “Repair Parts” section to help locate indicated parts. For the
sake of troubleshooting and using this guide to assist you, you should look at your heat level setting to see
which light is ashing.
Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to
”OFF” does not disconnect all power to the electrical components of the stove.
Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Display is Flashing “E1”
Possible Causes Possible Remedies: (Unplug stove rst when possible)
The convection blower is overheating and
tripping the internal temperature shutoff.
Clean any dust off of the windings and fan blade. If oiling
the blower does not help, the blower may be bad.
The stove is being left on the highest setting
for extended periods of time.
If operating the heater on the highest heat setting, the
room temperature could increase enough and lead
to potential overheating situations. If this happens try
operating at a lower heat setting.
Fuel other than wood pellets is being burned
in the stove.
This pellet stove is designed and tested to use wood pellets.
Check for signs of fuel other than wood pellets. No other
types of fuel have been approved for this pellet stove. If
there are signs of other types of fuel being used, stop using
them immediately.
Power surge or brown out situation.
A power surge, spike, or voltage drop could cause the high
limit switch to trip. Check to see if a surge protector is being
used on the stove. If not, recommend one to the customer.
High Limit Switch is malfunctioning. If the other items check out OK, replace the high limit
switch.
ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER
OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A
MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

United States Stove Company AP5622 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire

dans d''autres langues