United States Stove Ashley AP5660 Le manuel du propriétaire

Catégorie
Poêle à granulés
Taper
Le manuel du propriétaire

Ce manuel convient également à

852334J-0503J
MODEL: AP5660
United States Stove Company
227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
Please read this entire manual before installation and use of
this appliance. Failure to follow these instructions could result
in property damage, bodily injury, or even death.
Contact your local building or re ofcials about obtaining
permits, restrictions and installation inspection requirements in
your area.
SAVE THESE INSTRUCTIONS.
If your heater is not properly installed, a house re may result.
For everyone’s safety, follow all Installation and Operating
Directions. Never use makeshift compromises during the
installation of this appliance. Contact your local building
or re ofcials about restrictions and installation inspection
requirements in your area. These Pellet Stove Room Heaters
have been designed for use in the US and Canada and are
suitable for mobile homes.
This manual is subject to change without notice.
ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENT.
This unit is not intended to be used as a
primary source of heat.
Certied to ASTM E1509-12 ( 2017)
and Certied to ULC S627, 2000
U.S. Environmental Protection Agency
Certied to comply with 2020
particulate emissions standards.
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO
ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
R
Report #: F19-548
2
IMPORTANT: Read this entire manual before installing
and operating this product. Failure to do so may
result in property damage, bodily injury, or even
death. Proper installation of this stove is crucial for
safe and efcient operation.
Install vent at clearances specied by the vent
manufacturer.
Do not connect the pellet vent to a vent serving any
other appliance or stove.
Do not install a ue damper in the exhaust venting
system of this unit.
Use of outside air is not required for this unit.
Contact your local building ofcials to obtain a
permit and information on any additional installation
restrictions or inspection requirements in your area.
Do not throw this manual away. This manual has
important operating and maintenance instructions
that you will need at a later time. Always follow the
instructions in this manual.
This appliance is designed for the use of pelletized
fuel that meet or exceed the standard set by the
Pellet Fuel Institute(PFI),
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter uid, or similar liquids to
start or ’freshen up’ a re in this stove. Keep all such
liquids well away from the stove while it is in use.
A working smoke detector must be installed in the
same room as this product.
Install a smoke detector on each oor of your home;
incase of accidental re from any cause it can
provide time for escape.
The smoke detector must be installed at least 15
feet (4,57 M) from the appliance in order to prevent
undue triggering of the detector when reloading.
Do not unplug the stove if you suspect a malfunction.
Turn the ON/OFF switch to ”OFF’ and contact your
dealer.
Your stove requires periodic maintenance and
cleaning (see ”Maintenance”). Failure to maintain
your stove may lead to improper and/or unsafe
operation.
Disconnect the power cord before performing any
maintenance! NOTE: Turning the ON/OFF Switch to
”OFF” does not disconnect all power to the electrical
components of the stove.
Never try to repair or replace any part of the stove
unless instructions for doing so are given in this
manual. All other work should be done by a trained
technician.
Do not operate your stove with the viewing door
open. The auger will not feed pellets under these
circumstances and a safety concern may arise from
sparks or fumes entering the room.
Allow the stove to cool before performing any
maintenance or cleaning. Ashes must be disposed
in a metal container with a tight tting lid. The
closed container of ashes should be placed on a
non-combustible surface or on the ground, well
away from all combustible materials, pending nal
disposal.
The exhaust system should be checked monthly
during the burning season for any build-up of soot
or creosote.
Do not touch the hot surfaces of the stove. Educate
all children on the dangers of a high-temperature
stove. Young children should be supervised when
they are in the same room as the stove.
The hopper and stove top will be hot during
operation; therefore, you should always use some
type of hand protection when refuelling your stove.
A power surge protector is required. This unit must be
plugged into a 110 - 120V, 60 Hz grounded electrical
outlet. Do not use an adapter plug or sever the
grounding plug. Do not route the electrical cord
underneath, in front of, or over the heater. Do not
route the cord in foot trafc areas or pinch the cord
under furniture.
The heater will not operate during a power outage.
If a power outage does occur, check the heater for
smoke spillage and open a window if any smoke
spills into the room.
The feed door must be closed and sealed during
operation.
Never block free airow through the open vents of
the unit.
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled by high
torque electric motors. Keep all body parts away
from the auger while the stove is plugged into an
electrical outlet. These moving parts may begin to
move at any time while the stove is plugged in.
Do not place clothing or other ammable items on
or near this stove.
When installed in a mobile home, the stove must be
grounded directly to the steel chassis and bolted to
the oor. WARNING - THIS UNIT MUST NOT BE INSTALLED
IN THE BEDROOM. CAUTION - The structural integrity
of the mobile home oor, wall, and ceiling/roof must
be maintained.
This appliance is not intended for commercial use.
CAUTION: Burning fuel creates carbon monoxide
and can be hazardous to your health if not properly
vented.
This appliance is a freestanding heater. It is not
intended to be attached to any type of ducting. It
is not a furnace.
Safety Precautions
3
Heating Specications
Fuel Burn Rate* (lowest setting) 1.5 lbs./hr.
Hopper Capacity 45 lbs.
Dimensions
Height 30.50 po (775 mm)
Width 24.25 po (616 mm)
Depth 26.19 po (665 mm)
Electrical Specications
Electrical Rating 115-120 volts, 60 HZ, 3.0 Amps
Watts (operational) 180W
Watts (igniter running) 346W
This manual describes the installation and operation of the Ashley, AP5660 pellet stove. This heater meets the 2020
U.S. Environmental Protection Agency’s crib wood emission limits for wood-heaters sold after May 15, 2020. Under
specic EPA test conditions burning Douglas Fir dimensional lumber this heater has been shown to deliver heat at
a rate of 11,155 to 24,361 btu/hr. This heater achieved a particulate emissions rate of 1.9 g/hr and an efciency
of 62%.
FUEL CONSIDERATIONS
Your pellet stove is designed and tested with premium grade pellets that comply with Pellet Fuels Institute (PFI)
standards. You can only burn premium grade pellets in this pellet heater (minimum of 40 lbs density per cubic
feet, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight,
ash under 1% by weight, and salt under 300 parts per million). Pellets that are soft, contain excessive amounts
of loose sawdust, have been, or are wet, will result in reduced performance and may cause damage to your
heater. Store your pellets in a dry place. DO NOT store the fuel within the installation clearances of the unit or
within the space required for refuelling and ash removal. Doing so could result in a house re. Do not over-re or
use volatile fuels or combustibles, doing so may cause a personal and property damage hazards.
SAFETY AND EPA COMPLIANCE
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a
manufactured or mobile home. Your stove is Certied to ASTM E1509-12 (2017), and Certied to ULC S627, 2000
* Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%.
Use PFI listed fuel for best results.
Specications
WARNING: It is against federal regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner’s manual.
4
INSTALLATION OPTIONS
Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result
in property damage, bodily injury, or even death! See specic installation details for clearances and other
installation requirements.
Freestanding Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove installation.
Alcove Unit - supported by pedestal/legs and placed on a non-combustible oor surface in compliance with
clearance requirements for an alcove installation.
Your pellet stove may be installed to code in either a conventional or mobile home (see Special Mobile Home
Requirements). It is recommended that only a authorized technician install your pellet stove, preferably an NFI
certied specialist. DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. The use of other
components other than stated herein could cause bodily harm, heater damage, and void your warranty.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the malfunction
of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if
you have any questions.
Installation
CLEARANCES
Your pellet stove has been tested and listed for installation in residential, mobile home, and alcove applications
in accordance with the clearances given. For safety reasons, please adhere to the installation clearances and
restrictions. Any reduction in clearance to combustibles may only be done by means approved by a regulatory
authority.
INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER
When this unit is being installed on a combustible oor it is mandatory that a 1/2” (13 mm) thick non-combustible
hearth pad be installed under the heater. The non-combustible hearth pad must extend at least 6” (152 mm)
beyond the fuel loading and ash removal openings and at least the depth of the heater plus 6” (152 mm) out in
front of the heater. The oor protector must extend 2” (51mm) beyond each side of the exhaust vent. This applies
to both freestanding heaters and insert heaters.
BACK WALL
Figure 5
Figure 6
Alcove Dimensions
36”
35”
40”
2”
6”
USA 6”
CANADA 8”
FLOOR PROTECTION
USA 6”
CANADA 18”
2”
FLOOR
PROTECTION
USA 6”
CANADA 8”
USA 6”
CANADA 18”
BACK WALL
Figure 5
Figure 6
Alcove Dimensions
36”
35”
40”
2”
6”
USA 6”
CANADA 8”
FLOOR PROTECTION
USA 6”
CANADA 18”
2”
FLOOR
PROTECTION
USA 6”
CANADA 8”
USA 6”
CANADA 18”
BACK WALL
Figure 5
Figure 6
Alcove Dimensions
36”
35”
40”
2”
6”
USA 6”
CANADA 8”
FLOOR PROTECTION
USA 6”
CANADA 18”
2”
FLOOR
PROTECTION
USA 6”
CANADA 8”
USA 6”
CANADA 18”
FLOOR PROTECTION
This heater must have a non-combustible oor
protector (ember protection) installed beneath it if the
oor is of combustible material. If a oor pad is used,
it should be UL listed or equal. The oor pad or non-
combustible surface should be large enough to cover
at least the area under the product and 6” (152 mm)
beyond the front and beyond each side of the fuel
loading and ash removal openings. Floor protection
must extend under and 2“ (51 mm) to each side of
the chimney tee for an interior vertical installation.
Canadian Installations require a minimum of 450 mm
[17.7”] beyond the front of the unit and 200 mm [7.8”]
beyond each side of the unit. A Floor Protector of 1/4”
thick is recommended for this installation.
Attention: DO NOT vent under any porch, deck, awning, or in any semi enclosed or roofed area. Doing so may
result in unpredictable airow at the vent cap under certain conditions and can affect the performance of
your stove, as well as, other unforeseeable issues.
5
VENTING REQUIREMENTS
Install vent at clearances specied by the vent manufacturer.
Do not connect the pellet vent to a vent serving any other appliance or stove.
Do not install a ue damper in the exhaust venting system of this unit.
The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove
and to local building codes. Do not use makeshift methods or compromise in the installation.
IMPORTANT! This unit is equipped with a negative draft system that pulls air through the burn pot and pushes
the exhaust out of the dwelling. If this unit is connected to a ue system other than the way explained in this
manual, it will not function properly.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical pipe outside the home. This will create some natural draft to
reduce the possibility of smoke or odor during appliance shutdown and keep exhaust from causing a nuisance
or hazard by exposing people or shrubs to high temperatures. The maximum recommend vertical venting height
is 12-feet for 3-inch type “PL” vent. Total length of horizontal vent must not exceed 4-feet. This could cause back
pressure. Use no more than 180 degrees of elbows (two 90-degree elbows, or two 45-degree and one 90-degree
elbow, etc.) to maintain adequate draft.
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too
much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpufng into
the room and ‘plugging’ of the chimney. Inadequate draft will cause the appliance to leak smoke into the room
through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates
excessive draft. Take into account the chimney’s location to ensure it is not too close to neighbors or in a valley
which may cause unhealthy or nuisance conditions.
PELLET VENT TYPE
A certied 3-inch or 4-inch type “PL” pellet vent exhaust system must be used for installation and attached to the
pipe connector provided on the back of the stove (use a 3-inch to 4-inch adapter for 4-inch pipe). Connection
at back of stove must be sealed using Hi-Temp RTV. Use 4-inch vent if the vent height is over 12-feet or if the
installation is over 2,500 feet above sea level. We recommend the use of Simpson Dura-Vent® or Metal-Fab®
pipe (if you use other pipe, consult your local building codes and/or building inspectors). Do not use Type-B Gas
Vent pipe or galvanized pipe with this unit. The pellet vent pipe is designed to disassemble for cleaning and
should be checked several times during the burning season. Pellet vent pipe is not furnished with the unit and
must be purchased separately.
PELLET VENT INSTALLATION
The installation must include a clean-out tee to enable collection of y ash and to permit periodic cleaning of the
exhaust system. 90-degree elbows accumulate y ash and soot thereby reducing exhaust ow and performance
of the stove. Each elbow or tee reduces draft potential by 30% to 50%. All joints in the vent system must be
fastened by at least 3 screws, and all joints must be sealed with Hi-Temp RTV silicone sealant to be airtight. The
area where the vent pipe penetrates to the exterior of the home must be sealed with silicone or other means to
maintain the vapor barrier between the exterior and the interior of the home. Vent surfaces can get hot enough
to cause burns if touched by children. Non-combustible shielding or guards may be required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-enclosed area, such as; carport, garage, attic, crawl space,
under a sun deck or porch, narrow walkway, or any other location that can build up a concentration of fumes.
Termination in one of these areas can also lead to unpredictable pressure situations with the appliance, and
could result in improper performance and/or malfunction The termination must exhaust above the outside air
inlet elevation. The termination must not be located where it will become plugged by snow or other materials. Do
not terminate the venting into an existing steel or masonry chimney.
6
VENT TERMINATION CLEARANCES
A. Minimum 4-foot (1.22m) clearance below or
beside any door or window that opens.
B. Minimum 1-foot (0.3m) clearance above any
door or window that opens.
C. Minimum 3-foot (0.91m) clearance from any
adjacent building.
D. Minimum 7-foot (2.13m) clearance from any
grade when adjacent to public walkways.
E. Minimum 2-foot (0.61m) clearance above any
grass, plants, or other combustible materials.
F. Minimum 3-foot (0.91m) clearance from an
forced air intake of any appliance.
G. Minimum 2-foot (0.61m) clearance below eves
or overhang.
H. Minimum 1-foot (0.3m) clearance horizontally
from combustible wall.
I. Must be a minimum of 3 foot (0.091m) above
the roof and 2 foot (0.61m) above the highest
point or the roof within 10 feet (3.05m).
G
Assembly Instructions
Step 1
Pull the factory installed wires out
of the top of the stove. There will
be two wire harnesses, as shown.
Step 2
Unpack the top mount controls and
ensure that the wiring harness shown
is attached securely.
Step 3
Connect the factory installed
wiring harnesses to the control
panel as shown.
Step 4
Attach the control panel to the top of the stove, as shown.
Step 5
Secure with two sheet metal screws.
7
You have already made the important decision of choosing your U.S. Stove Pellet Burning Room Heater; now
your next step is to determine where to install your new pellet stove heater. To get the most efcient use of re-
circulated heat, you should consider a room that is centrally located within your home. Choose a room that
is large and open. It is Extremely Important to maintain proper clearances from any combustible surfaces or
materials in the room where your heater will be located. You can nd proper clearance measurements in this
manual and on the rating label of your pellet stove. The pellet stove can be vented through an exterior wall or
into an existing masonry or metal chimney if “PL” or “L” vent pipe is used throughout existing chimney. Venting
can pass through the ceiling and roof if approved pipe is used. Where passage through a wall, or partition of
combustible construction is desired, the installation must conform to CAN/CSA-B365.
DO NOT OBTAIN COMBUSTION AIR FROM THE ATTIC, GARAGE OR ANY OTHER UNVENTILATED AREA. YOU MAY
OBTAIN COMBUSTION AIR FROM A VENTILATED CRAWL SPACE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER HEATER, FURNACE OR APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
ONLY USE APPROVED MATERIAL FOR INSTALLATION, FAILURE TO DO SO MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
This appliance is certied for use with listed 3 inch or 4 inch “PL” or “L” pellet venting products. The use of other
components other than stated herein could cause bodily harm, heater damage, and void your warranty.
HORIZONTAL EXHAUST VENT INSTALLATION
1. Locate your pellet stove in a location which meets the requirements of this manual, but in an area where it
does not interfere with the house framing, wiring, etc.
2. Install a non-combustible hearth pad underneath the pellet stove. This pad should extend at least 6” (152
mm) in front of the unit.
3. Place the pellet stove approximately 15” (381 mm) away from the interior wall.
4. Locate the center of the exhaust pipe of your unit. This point should then be extended to the interior wall of
your house. Once you have located the center point, on the interior wall, cut a 7” (175 mm) diameter hole
through the wall.
5. The next step is to install the wall thimble, refer to the instructions which come with the wall thimble for this
step.
6. Install the appropriate length of exhaust vent pipe into the wall thimble. See steps 11 and 12 when determining
the correct length of exhaust vent to use.
7. Outside Fresh Air is Mandatory when installing this pellet stove room heater in airtight homes and mobile
homes. Be sure that the outside air vent has an approved cap on it to prevent rodents from entering. Be sure
to install in location that won’t become blocked with snow, etc.
8. The air intake pipe is equipped with a buttery valve that is preset to maximum air intake. For optimum
operating efciency you may calibrate the buttery valve to provide less intake air. Caution: Too much
restriction on the intake air will cause dirtier burn, therefore, will require more frequent cleaning.
9. Connect the exhaust vent pipe to the exhaust outlet of your pellet stove.
10. Secure all vent joint connections with 3 screws. Seal the exhaust vent joint connections with high temperature
silicone sealant.
11. Push the unit straight back to the interior wall, being sure to maintain the minimum clearances to combustibles
6” (152 mm) to the back of the unit. Seal the annular space of the wall thimble and around the vent pipe with
high temperature silicone sealant.
12. The exhaust vent pipe must extend at least 12” (300 mm) out past the exterior wall. Seal the annular space of
the wall thimble and around the vent pipe with high temperature silicone sealant.
13. Install an approved horizontal termination cap or if necessary install a 90° elbow and appropriate length of
vertical venting. An approved vertical vent cap is recommended.
8
THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION)
Canadian installations must conform to CAN/CSA-B365. To vent the unit through the wall, connect the pipe
adapter to the exhaust motor adapter. If the exhaust adapter is at least 18 in.(457mm) above ground level, a
straight section of pellet vent pipe can be used through the wall. Your heater dealer should be able to provide
you with a kit that will handle most of this installation, which will include a wall thimble that will allow the proper
clearance through a combustible wall. Once outside the structure, a 3” (76 mm) clearance should be maintained
from the outside wall and a clean out tee should be placed on the pipe with a 90-degree turn away from the
house. At this point, a 3ft (0.91m) (minimum) section of pipe should be added with a horizontal cap, which would
complete the installation. A support bracket should be placed just below the termination cap or one every 4ft
(1.22m) to make the system more stable. If you live in an area that has heavy snowfall, it is recommended that
the installation be taller than 3ft (0.91m) to get above the snowdrift line. This same installation can be used if
your heater is below ground level by simply adding the clean-out section and vertical pipe inside until ground
level is reached. With this installation you have to be aware of the snowdrift line, dead grass, and leaves. We
recommend a 3ft (0.91m) minimum vertical rise on the inside or outside of the house. The “through the wall”
installation is the least expensive and simplest installation. Never terminate the end vent under a deck, in an
alcove, under a window, or between two windows.
THROUGH THE ROOF/CEILING INSTALLATION
When venting the heater through the ceiling, the pipe is connected the same as through the wall, except the
clean-out tee is always on the inside of the house, and a 3 in.(76mm) adapter is added before the clean-out tee.
You must use the proper ceiling support anges and roof ashing (supplied by the pipe manufacturer; follow the
pipe manufacturer’s directions). It is important to note that if your vertical run of pipe is more than 15ft (4.57m),
the pellet vent pipe size should be increased to 4” (102 mm) in diameter. Do not exceed more than 4ft (1.22m) of
pipe on a horizontal run and use as few elbows as possible. If an offset is required, it is better to install 45-degree
elbows rather than 90-degree elbows.
9
Canadian installations require that the heater must be connected to a
3 or 4 inch, factory-built chimney conforming to CAN/ULC-S629. See the
installation illustrations in this manual for minimum height above the roof.
The chimney installation must allow for removal in case of mobile home
transportation, especially outside connections. You may contact your
local building authority or person having jurisdiction on height restrictions.
In order for this unit to be installed in a mobile home the following criteria
must be met:
The unit must be secured to the oor using lag bolts in the holes
provided in the pedestal base.
Ensure that the unit is permanently electrically grounded to the
chassis of your home with 18 gauge copper wire.
All exhaust systems must have a spark arrestor.
IT IS MANDATORY TO TAKE THE COMBUSTION AIR FROM THE OUTSIDE
WHEN INSTALLING THIS UNIT IN AIR TIGHT OR MANUFACTURED/MOBILE
HOMES.
CAUTION: The structural integrity of the manufactured home oor,
wall, and ceiling/roof must be maintained. Make sure to maintain an
effective vapor barrier by sealing with silicone where the chimney or
other components penetrate to the exterior of the structure. Refer to
and follow the chimney manufacturer’s installation instructions.
WARNING: Do not install in sleeping room.
HEARTH PAD
FLOORING
GROUND WIRE, DIRECTLY
TO METAL CHASSIS
STEEL FRAME
1/4” LAG BOLTS,
SECURELY FASTENED
Mobile Home Installation
NOTE: Only the free standing model
is approved for installation into a
mobile home.
69FAK OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME)
Depending on your location and home construction, outside air may be necessary for optimal performance.
1. With the stove in the operating position, mark and drill a hole to accommodate the 2” exible hose.
2. Insert the hose through the wall and attach the Outside Cover with one of the 2” hose clamps provided.
3. Then attach the Outside Cover to the outside wall.
4. Next, attach the Rodent Cover to the Outside Cover using four (4) of the #10 x 3/4 screws supplied.
5. On the inside of the home, slide the Inside Plate over the tube then attach to the wall with the four drywall
anchors and screws provided.
6. On the Air Inlet Tube coming out of the rebox, there is a cap that must have four (4), 5/32” (0.156) diameter
holes drilled in it for the fresh air installation. The cap is on the front side of the tube just under the burnpot.
Remove burnpot. Using a long screwdriver or equivalent, knock the cap off by inserting it from the back of
the stove and pecking with a hammer. Drill holes, then replace cap and burnpot.
7. Attach one of the 2” ex hoses to the backside of the rebox, then to air inlet pipe at the back of the stove
as shown.
8. Stretch the 2” ex hose to the air inlet on the back of the stove. Attach using the other 2” hose clamp. The
hose will extend up to 4 feet in length.
FRESH AIR INTAKE
EXHAUST PIPE
Figure 1
B
C
E
A
Figure 2
A
D
10
PANEL/REMOTE CONTROLS
The blowers and automatic fuel supply are controlled from a panel on the top of the stove.
The control panel functions are a follows.
A. ON/OFF SWITCH (“POWER” BUTTON)
When pushed, the stove will automatically ignite. No other re starter is necessary. The
igniter will stay on for at least 10 and up to 12 minutes, depending on when Proof of Fire is
reached. The re should start in approximately 5 minutes.
The red light located above the “POWER” button will turn green when pressed and remain
green until the stove is turned off.
After pushing “POWER”, the auger motor is on for 3.5 minutes, off for 1 minute. During the
remainder of the start-up period, the auger motor operates on the heat range “1” setting.
During start up the heat level advance (Up and Down keys) will change the heat range
indicator level accordingly, but there is no change in the stoves operating conditions until
start-up is completed.
During start-up ignition must occur within 12 minutes or the stove will error out and show E4.
During the start-up phase, the Mode key does not function.
B. LEVEL / TEMP ARROW BUTTONS
These buttons when pushed will set the pellet feed rate, hence the heat output or heat
range of your stove.
The levels of heat output will incrementally change on the bar graph starting from heat
range “1” to heat range “5”.
C. °C / °F BUTTON
The °C / °F button changes the two digit display
from degrees Celsius to degrees Fahrenheit.
D. MODE (M/T) BUTTON
The Mode of the stove can be switched between
manual and controlled with a Thermostat.
Separate LEDs to the left of the two digit display
indicate the mode of operation – Manual or
T-Stat. The stove has to be in normal operation to
be switched from Manual to T-Stat mode.
Manual mode operates according to the 5 set
levels of feed on the bar graph from heat range
“1” to heat range “5”.
T-Stat mode works as follows:
The stove has a built in Thermostat into the
controls of the appliance. The temperature
sensor for the T-Stat is located on the back of the
stove behind the display board.
Once the stove has gone into run mode the stove can be switch into T-Stat mode.
The Up and Down Level / Temp Arrow buttons are used to change the desired set-point temperature. Once
the desired temperature is reached the two digit display will ash for four seconds and reset to the actual room
temperature.
Once the stove reaches within 3°F of the desired temperature set point, it returns to the heat range that the
stove was set on before it was switched to T-Stat mode (if the stove was running on heat range “5” when
switched to T-stat mode when it gets within 3°F of the set point it will return to heat range “5”).
Once the stove reaches the desired set-point, the stove will drop to heat range “1”.
When room temperature drops below desired set-point the stove will ramp back up until it reaches the desired
temperature.
Level / Temp
Manual
T-Stat
Appliance Controls
11
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE - Never use gasoline, gasoline-type lantern fuel, kerosene,
charcoal lighter uid, or similar liquids to start or “freshen up” a re in this stove. Keep all such liquids well away
from the stove while it is in use.
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS.
This heater is designed to burn only PFI Premium grade pellets. DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners,
or asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Salt water driftwood or other previously salt water
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or
particleboard. The prohibition against burning these
materials does not prohibit the use of re starters
made from paper, cardboard, saw dust, wax and
similar substances for the purpose of starting a re in
an affected wood heater.
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
PROPER FUEL
THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY ! Factory-approved pellets are those 1/4”
or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger ights, which
prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building
codes for which the stove has been approved and will void all warranties. The design incorporates automatic
feed of the pellet fuel into the re at a carefully prescribed rate. Any additional fuel introduced by hand will not
increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do
not burn wet pellets. The stove’s performance depends heavily on the quality of your pellet fuel. Avoid pellet
brands that display these characteristics:
1. Excess Fines “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand.
Pellets can be screened before being placed in hopper to remove most nes.
2. Binders – Some pellets are produced with materials to hold the together, or “bind” them.
3. High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for
more frequent maintenance. You will have to empty the burn pot plus vacuum the entire system more often.
Poor quality pellets could damage the auger. We cannot accept responsibility for damage due to poor
quality pellet.
PRE-START-UP CHECK
Remove burn pot, making sure it is clean and none of the air holes are plugged. Clean the rebox, and then
reinstall burn pot. Clean door glass if necessary (a dry cloth or paper towel is usually sufcient). Never use abrasive
cleaners on the glass or door. Check fuel in the hopper, and rell if necessary.
BUILDING A FIRE
Never use a grate or other means of supporting the fuel. Use only the burn pot supplied with this heater.
Hopper lid must be closed in order for the unit to feed pellets.
During the start-up period:
1. Make sure burn pot is free of pellets.
2. DO NOT open the viewing door.
3. DO NOT open the damper, the damper needs to be closed during start up.
4. DO NOT add pellets to the burn pot by hand.
NOTE: During the rst few res, your stove will emit an odor as the high temperature paint cures or becomes
seasoned to the metal. Maintaining smaller res will minimize this. Avoid placing items on stove top during this
period because paint could be affected.
Operation
12
THE FIRESTARTER
1. Fill hopper and clean burn pot.
2. Press “On/Off” button. Make sure green light comes on.
3. The damper should be completely closed or open no more than 1/4 of the way during start-up. This will vary
depending on your installation and elevation. Once re is established adjust for desired ame increasing the
amount the damper is open as the heat setting is increased. (See “DAMPER CONTROL”)
4. Adjust feed rate to desired setting by pressing “Heat Level Advance” button.
If re doesn’t start in 12 minutes, press “On/Off”, wait a few minutes, clear the burn pot, and start procedure
again.
DAMPER CONTROL
The damper control lever is located on the back of the stove on the lower left side. The dampener adjusts
the combustion air. This control is necessary due to the varied burn characteristics of individual installations,
different pellet brands and pellet feed rates. It allows you to improve the efciency of your stove. Providing
correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of
creosote inside your stove and chimney.
You should adjust the damper based on the re’s appearance. A low, reddish, dirty re can be improved by
turning the dampener slightly to the right. A “blow torch” re can be improved by turning the dampener to the
left a little bit.
As a general rule, on lower feed rate settings, the damper should be farther to the left closing it off. On higher
feed rates, the damper should be open more by having it set more towards the right. Through trial and error, you
will nd the best setting. Consult your dealer if you need help.
NOTE: On heat range “1”, damper should be either completely closed or open no more than a 1/4 of the way. If
damper is open to far, it can cause the re to go out.
OPENING DOOR
If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down.
If the stove shuts down push the “On/Off” button to re-start your stove. The stove will have to fully shut down and
turn off before you will be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This
usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The re goes out and the auger motor and blowers will run until the stove cools. This will take 30 minutes or longer
depending on the heat remaining in the appliance. After the stove components stop running all lights on the
display will go out and the two digit display will begin ashing “E3”
REFUELING
The hopper and stove top will be hot during operation; therefore, you should always use some type of hand
protection when refueling your stove.
Never place your hand near the auger while the stove is in operation.
We recommend that you not let the hopper drop below 1/4 full.
KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.
SHUTDOWN PROCEDURE
Turning your stove off is a matter of pressing the “POWER” button on the display board. The green light will turn
back to red when the “POWER” button is pushed. The auger motor will stop, and the blowers will continue to
operate until the internal rebox temperatures have fallen to a preset level.
1. Your stove is equipped with a high temperature thermodisc. This unit has a manual reset thermodisc. This
safety switch has two functions.
A. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically
shut down the auger, preventing the stove from overheating.
WARNING: Never shut down this unit by unplugging it from the power source.
13
Maintenance
NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem.
A service call may be required.
2. If the combustion blower fails, an air pressure switch will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed off. The stove will shut down and show “E2” on the two digit display.
The stove has to fully shut down before restarting.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
VISIBLE SMOKE
The amount of visible smoke being produced can be an effective method of determining how efciently the
combustion process is taking place at the given settings. Visible smoke consist of unburned fuel and moisture
leaving your stove. Learn to adjust the air settings of your specic unit to produce the smallest amount of visible
smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess
visible smoke and burn poorly.
Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.
Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any
inspection, cleaning, or maintenance work.
Never perform any inspections, cleaning, or maintenance on a hot stove.
Do not operate stove with broken glass, leakage of ue gas may result.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
EXHAUST SYSTEM
Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine
with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney ue or a
newly started re or from a slow-burning re. As a result, creosote residue accumulates on the ue lining. When
ignited, this creosote makes an extremely hot re, which may damage the chimney or even destroy the house.
Despite their high efciency, pellet stoves can accumulate creosote under certain conditions.
Fly Ash This accumulates in the horizontal portion of an exhaust run. Though non-combustible, it may impede
the normal exhaust ow. It should therefore be periodically removed.
Inspection and Removal The chimney connector and chimney should be inspected by a qualied person annually
or per ton of pellets to determine if a creosote or y ash build-up has occurred. If creosote has accumulated, it
should be removed to reduce the risk of a chimney re. Inspect the system at the stove connection and at the
chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney
from the top as well as from the bottom. The creosote should be removed with a brush specically designed for
the type of chimney in use. A qualied chimney sweep can perform this service. It is also recommended that
before each heating season the entire system be professionally inspected, cleaned and, if necessary, repaired.
To clean the chimney, disconnect the vent from the stove.
14
INTERIOR CHAMBERS
Burn Pot: Periodically remove and clean the burn pot and the area inside the burn pot housing. In particular,
it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving
through the burn pot freely.
Heat Exchanger: There is a clean out plate on both sides of the heat exchanger that need to be removed to
clean y ash out of the heat exchanger. The clean outs are located inside the cabinet doors, on the lower
front corners of the heat exchanger. It is imperative that they be cleaned out at a minimum of once per
month. To access these clean outs, you must remove both side panels. The clean outs are secured to the
rebox with (2) 5/16” screws. Remove the clean outs and vacuum out any accumulated ash. This should be
done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the
stove does not seem to be burning properly
If a vacuum is used to clean your stove, we suggest using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH
CLEANING
Heat Exchanger Tubes Your Pellet Stove Room Heater is designed with a
built in heat exchanger tube cleaner. This should be used every 2 or 3 days to
remove ash build up on the heat exchanger tubes, which can reduce heat
transfer. The handle, for the heat exchanger tube cleaner, is located in front
of the vent tubes on front side of heater. Slide the rod front to back several
times to clean the tubes then follow the instructions for ash removal.
Periodically remove the clean outs on either side of the heat exchanger.
Clean out the ash, then follow the instructions for ash removal. Check the
gasket before replacing the clean out cover. If gasket is damaged new
gasket can be ordered. Alternatively, high temperature silicone can be used
to ensure a proper seal between the clean out cover and the stove body.
WARNING: FAILURE TO PROPERLY MAINTENANCE THE CLEAN OUTS WILL RESULT
IN POOR PERFORMANCE OF THIS STOVE.
WARNING: Do not attempt to operate the heat exchange tube cleaner while the pellet stove is in operation or
cooling down; wait until pellet stove has cooled completely before performing this procedure.
LOCATING THE RIGHT AND LEFT SIDE CLEANOUTS (CLEAN THOROUGHLY)
HEAT
EXCHANGER
CLEANER
HANDLE
COVER
CLEANOUTS
GASKET
RIGHT
SIDE
COVER
CLEANOUTS
GASKET
LEFT
SIDE
15
LOCATING THE FRONT CLEANOUTS (CLEAN ANNUALLY)
1. Remove the front glass by releasing the two latches attaching it to the unit. They are located behind the right
side panel.
2. Remove the two side brick panels.
3. Remove the two interior side panels.
FRONT
CLEANOUTS
16
Circulation
Fan
Exhaust
Fan
Ignitor
Auger Motor
FANS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT
Over time ash or dust may accumulate on the blades of the circulation & exhaust
fans. The fans should be inspected, periodically, and if any accumulation is present
vacuumed clean as the ash or dust can impede the fans performance. It is also
possible that creosote may accumulate in the exhaust fan therefore, this must be
brushed clean. The exhaust fan can be found behind the left side panel (facing the
front of the heater), the circulation fan can be found behind the right side panel.
To access the igniter, remove the air inlet tube and cover (2 screws). The auger
motor is located in the center rear of the unit. Note: When cleaning, take care not
to damage the fan blades.
CHECK AND CLEAN THE HOPPER
Check the hopper periodically to determine if there is any sawdust (nes) that is
building up in the feed system or pellets that are sticking to the hopper surface.
Clean as needed.
DOOR AND GLASS GASKETS
Inspect the main door and glass window gaskets periodically. The main door may need to be removed to have
frayed, broken, or compacted gaskets replaced by your authorized dealer. This unit’s door uses a 3/4” diameter
rope gasket.
BLOWER MOTORS
Clean the air holes on the motors of both the exhaust and distribution blowers annually. Remove the exhaust
blower from the exhaust duct and clean out the internal fan blades as part of your fall start-up.
PAINTED SURFACES
Painted surfaces may be wiped down with a damp cloth. If scratches appear, or you wish to renew your paint,
contact your authorized dealer to obtain a can of suitable high-temperature paint.
GLASS - CLEANING, REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
Cleaning - We recommend using a high quality glass cleaner. Should a buildup of creosote or carbon accumulate,
you may wish to use 000 steel wool and water to clean the glass. DO NOT use abrasive cleaners. DO NOT perform
the cleaning while the glass is HOT. Do not attempt to operate the unit with broken glass. Replacement glass may
be purchased from your U.S. Stove dealer. If glass is broken, follow these removal procedures:
1. Once the heater has cooled, remove the door from the heater.
2. Remove the rope gasket from the door followed by the eight(8) nuts holding the glass retainer in place.
3. While wearing gloves, carefully remove any loose pieces of glass from the door frame.
4. Replace the glass and gasket, making sure the gasket runs the full perimeter of the glass edge.
5. Re-install the retainer and eight nuts and rope gasket using high temperature silicone to adhere the gasket
to the door.
6. Never use substitute materials for the glass.
DO NOT abuse the door glass by striking, slamming or similar trauma. Do not operate the stove with the glass
removed, cracked or broken.
FALL START UP
Prior to starting the rst re of the heating season, check the outside area around the exhaust and air intake
systems for obstructions. Clean and remove any y ash from the exhaust venting system. Clean any screens on
the exhaust system and on the outside air intake pipe. Turn all of the controls on and make sure that they are
working properly. This is also a good time to give the entire stove a good cleaning throughout.
17
SPRING SHUTDOWN
After the last burn in the spring, remove any remaining pellets from the hopper and the auger feed system. Scoop
out the pellets and then run the auger until the hopper is empty and pellets stop owing (this can be done by
pressing the “ON” button with the viewing door open). Vacuum out the hopper. Thoroughly clean the burn pot,
and rebox. It may be desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your
stove is in a high humidity area. The exhaust system should be thoroughly cleaned.
MAINTENANCE SCHEDULE
Use the following as a guide under average use conditions. Gaskets around door and door glass should be
inspected and repaired or replaced when necessary.
ASH REMOVAL
Remove the ashes periodically to avoid unnecessary ash build up. Ash removal is as follows:
1. Let the re burn out and allow the unit cool to room temperature.
2. Clean the heat exchanger tubes (see Heat Exchanger Cleaning section) – Make sure Pellet Stove is at room
temperature before touching.
3. Open the ash pan door, remove the burn pot and empty it into a metal container.
4. Vacuum to remove ashes from the rebox.
5. BE SURE THAT ASHES ARE COOL TO THE TOUCH BEFORE VACUUMING. Some vacuum cleaners may leak ash
into the room. Your vacuum cleaner should have a special lter or bag to eliminate leakage.
6. Remove ash pan and dispose of ashes into a metal container.
7. Reinstall ash pan.
8. Reinstall burn pot.
Daily Weekly Monthly or as needed
Burn Pot Stirred Empty
Combustion Chamber Brushed
Ashes Check Empty
Interior Chambers Vacuumed
Combustion Blower Blades Vacuumed / Brushed
Convection Blower Vacuumed / Brushed
Vent System Cleaned
Gaskets Inspected
Glass Wiped/Cleaned
Hopper (end of season) Emptied and vacuumed
Heat Exchanger Tubes Bi-Weekly
Attention: This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
DISPOSAL OF ASHES
Ashes should be placed in a steel metal container with a tight tting lid. The closed container of ashes should
be placed on a non-combustible oor or on the ground well away from all combustible materials, pending nal
disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the
closed container until all cinders have been thoroughly cooled. Do not place other waste in the same container.
SMOKE AND CO MONITORS
Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods of time. While the modern combustion systems in
heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or conned
areas can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing
properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas
having the potential to generate CO.
18
STEP 1
Locate the Burn Pot.
Above are the decorative logs in there correct location.
Your decorative logs should come in place, however if this is not the case the following steps depicts the correct
location.
STEP 2
Place log into correct position.
Burn Pot
Decorative Log Placement
19
When your stove acts out of the ordinary, the rst reaction is to call for help. This guide may save time and money
by enabling you to solve simple problems yourself. Problems encountered are often the result of only ve factors:
1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You
can usually solve those problems related to 1 and Your dealer can solve problems relating to 3, 4 and 5.
For the sake of troubleshooting and using this guide to assist, you should look at your heat level setting to see
which light is ashing.
Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF”
does not disconnect all power to the electrical components of the stove.
Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All
other work should be done by a trained technician.
Display is Flashing “E1”
Possible Causes Possible Remedies: (Unplug stove rst when possible)
The convection blower is overheating and tripping the
internal temperature shutoff.
Clean any dust off of the windings and fan blade. If oiling the
blower does not help, the blower may be bad.
The stove is being left on the highest setting for extended
periods of time.
If operating the heater on the highest heat setting, the room
temperature could increase enough and lead to potential
overheating situations. If this happens try operating at a lower
heat setting.
Fuel other than wood pellets is being burned in the stove.
This pellet stove is designed and tested to use wood pellets.
Check for signs of fuel other than wood pellets. No other
types of fuel have been approved for this pellet stove. If there
are signs of other types of fuel being used, stop using them
immediately.
Power surge or brown out situation.
A power surge, spike, or voltage drop could cause the high
limit switch to trip. Check to see if a surge protector is being
used on the stove. If not, recommend one to the customer.
High Limit Switch is malfunctioning. If the other items check out OK, replace the high limit switch.
Trouble Shooting Guide
Display is Flashing “E2”
Possible Causes Possible Remedies: (Unplug stove rst when possible)
Airow switch hose or stove attachment pipes for hose are
blocked.
Unhook air hose from the air switch and blow through it. If air
ows freely, the hose and tube are ne. If air will not ow throw
the hose, use a wire coat hanger to clear the blockage.
The air inlet, burnpot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash
or foreign material.
Follow all cleaning procedures in the maintenance section of
the owner’s manual.
The rebox is not properly sealed.
Make sure the door is closed and that the gasket is in good
shape.
Vent pipe is incorrectly installed.
Check to make sure vent pipe installation meets criteria in
owner’s manual.
The airow switch wire connections are bad.
Check the connectors that attach the gray wires to the air
switch.
Combustion blower failure.
With the stove on, check to see if the combustion blower is
running. If it is not, you will need to check for power going to
the combustion blower. It should be a full current. If there is
power, the blower is bad. If there is not, see #8.
Control board not sending power to combustion blower.
If there is no current going to the combustion blower, check all
wire connections. If all wires are properly connected, you have
a bad control board.
Control board not sending power to air switch.
There should be a 5-volt current (approximately) going to the
air switch after the stove has been on for 30 seconds.
20
Display is Flashing “E3”
Possible Causes Possible Remedies: (Unplug stove rst when possible)
The hopper is out of pellets Rell the hopper.
The air dampener is too far open for a low feed setting
If on the low setting, you may need to close the dampener
all the way.
The burnpot holes are blocked. Remove the burnpot and thoroughly clean it.
The air inlet, the interior chambers, or exhaust system has a
partial blockage.
Follow all cleaning procedures in the maintenance section of
the owner's manual
The hopper safety switch has failed or hopper is open.
When operating the unit, be sure the hopper lid is closed so
that the hopper safety switch will activate. Check the wires
leading from the hopper safety switch to the control panel
and auger motor for secure connections. Use a continuity
tester to test the hopper safety switch; replace if necessary.
The auger shaft is jammed.
"Start by emptying the hopper. Then remove the auger motor
by removing the auger pin, then remove the two bolts that
hold the auger bracket to the auger tube. The auger bracket
will now be able to be removed form the auger tube. Remove
the two bolts on the side of the auger tube to remove the
lower bearing of the auger. Pull the auger out of the tube to
free the jam.
The auger motor has failed.
Remove the auger motor from the auger shaft and try to run
the unit. If the motor will turn the shaft is jammed on something.
If the motor will not turn, the motor is bad.
The Proof of Fire (POF) thermodisc has malfunctioned.
Temporarily bypass the POF thermodisc by disconnecting the
two wires and connecting them with a short piece of wire.
Then plug the stove back up. If the stove comes on and works,
you need to replace the POF thermodisc. This is for testing only.
DO NOT LEAVE THE THERMODISC BYPASSED. Your blowers will
never shut off and if the re went out the auger will continue
to feed pellets until the hopper is empty if you leave the POF
thermodisc bypassed.
The control board is not sending power to the POF
thermodisc or other auger system components.
There should be a 5-volt (approximately) current going to the
POF thermodisc after the stove has been on for 10 minutes.
Display is Flashing “E4”
Possible Causes Possible Remedies: (Unplug stove rst when possible)
The air inlet, burnpot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash
or foreign material.
Follow all cleaning procedures in the maintenance section of
the owner’s manual.
The Proof of Fire (POF) thermodisc has came unplugged
Check the (POF) thermodisc to see if the wires are connected
properly.
The Proof of Fire (POF) thermodisc has malfunctioned.
Temporarily bypass the POF thermodisc by disconnecting the
two wires and connecting them with a short piece of wire.
Then plug the stove back up. If the stove comes on and works,
you need to replace the POF thermodisc. This is for testing only.
DO NOT LEAVE THE THERMODISC BYPASSED. Your blowers will
never shut off and if the re went out the auger will continue
to feed pellets until the hopper is empty if you leave the POF
thermodisc bypassed.
Air switch has failed.
To test the air switch, you will need to disconnect the air hose
from the body of the stove. With the other end still attached
to the air switch, very gently suck on the loose end of the hose
(you may want to remove the hose entirely off the stove and
the air switch rst and make sure it is clear). If you hear a click,
the air switch is working. BE CAREFUL TOO MUCH VACUUM
CAN DAMAGE THE AIR SWITCH.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

United States Stove Ashley AP5660 Le manuel du propriétaire

Catégorie
Poêle à granulés
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues