Digital Intelligent Outlet Relay
Contents
Installation Instructions 2
Mounting the RX1i Relay 2
Installation Notes 3
Connection to GrowControl™ GCX 3
GrowNET™ Hubs 3
Connection to USB AgrowLINK 4
Connection to MODBUS RTU 4
Serial Speed & Format 5
Supported Commands 5
Register Types 5
MODBUS Register Map 5
Technical Information 6
Troubleshooting 6
Maintenance & Service 6
Storage and Disposal 6
Warranty 6
Specications
Input Power (GrowNET™) 1 W @ 12-24Vdc
Max Current 12A @ 120Vac ~
HP Rating 1/2HP (8FLA @ 120Vac ~ )
Frequency 60 Hz
Receptacle Type NEMA 5-15R
Independent Relays 1
Status Indicators Red LED
Enclosure Knock-Outs (2) dia. 7/8”
Enclosure Rating IP40
Minimum Cycle Time 1 second
Interface GrowNET™, MODBUS
Relay Ratings 100,000 cycles
Relay Cycle Counters Up to 4 billion cycles per relay
INSTRUCTION MANUAL
RX1i
KEEP THESE INSTRUCTIONS
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
2
The RX1i intelligent relay is designed to be plugged into a stan-
dard 120Vac wall outlet mounted on a vertical wall surface.
A screw tab is provided which can be used to x the relay to the
wall outlet preventing accidental disconnection from the recep-
tacle.
Equipment to be controlled is then plugged into the outlet on
the RX1i. When the RX1i is activated, power will be switched to
the outlet on the RX1i from the wall outlet.
Mounting the RX1i Relay
General Notes:
1. Install into a vertical receptacle with the RJ45 connection facing down to maintain enclosure rating.
2. Device is not intended for use with an extension cord.
3. For indoor use and installation only.
Installation Instructions
DANGER Electrocution Hazard
Always un-plug the relay module before servicing or wiring; ensure all power is disconnected. For continued protection against
electric shock plug into grounded outlets only and do not remove the ground pin. Install all electrical equipment and wiring in
accordance with national and local electric codes. For indoor use in dry locations only (0-80% RH non-condensing.) Do not open
the relay; there are no user-serviceable parts inside.
DANGER Risque d’électrocution
Toujours non brancher le module de relais avant l’entretien ou le câblage; assurer l’alimentation est débranché. Pour une protec-
tion continue contre le bouchon de choc électrique dans des prises mises à la terre et ne pas retirer la broche de terre. Installez
tous les équipements électriques et le câblage conformément aux codes électriques nationaux et locaux. Pour une utilisation en
intérieur dans des endroits secs seulement (0-80% sans condensation.) Ne ouvrez pas le relais; il n’y a aucune pièce réparable par
l’utilisateur.
NOTICE:
Plug the relay fully ush into a wall receptacle.
Do not plug the relay into an extension cord.
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
3
GrowNET™ Hubs
All GrowNET™ devices are connected using standard CAT5 Ethernet cable with RJ-45 connections.
Devices can be connected directly to the GrowNET™ ports on the bottom of the controller, or through HX8
GrowNET™ hubs. It is typical to simplify cabling by locating hubs centrally in hall ways and rooms allowing
single runs from an 8-port device hub back to a central hub or back to the controller.
HX8 GrowNET ™ hubs expand a single port into eight more ports.
Hubs can be daisy-chained to form a network of up to 100 devices per
GrowNET™ bus. Individually buered port transcievers provide excellent
signal integrity and extended communication strength and range.
Hubs provide up to 1A of power for operating sensors and most relays
directly over the CAT5 cable. A DC jack on the hub provides 24Vdc power
to the ports from the included wall power supply. A terminal block
power option is also available.
Refer to the GCX controller manual for details on adding the device to the system.
Connection to GrowControl™ GCX
DIELECTRIC GREASE
Dielectric grease is recommended on RJ-45 GrowNET™ connections when used in humid environments.
Place a small amount of grease onto the RJ-45 plug contacts before inserting into the GrowNET™ port.
Non-conductive grease is designed to prevent corrosion from moisture in electrical connectors.
• Loctite LB 8423 • Dupont Molykote 4/5 • CRC 05105 Di-Electric Grease
• Super Lube 91016 Silicone Dielectric Grease • Other Silicone or Lithium based insulating grease
NOTICE
GrowNET™ ports use standard RJ-45 connections but are NOT compatible the Ethernet network equipment.
Do not connect GrowNET™ ports to Ethernet ports or network switch gear.
Installation Notes
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
4
LX1 USB AgrowLINK connects Agrowteks devices to a computer’s USB port for:
Connection to USB AgrowLINK
Firmware Updates
Manual Operation
API Based Control
More
Agrowtek’s intelligent relays may be connected to the LX1 USB AgrowLINK for rmware updates, commu-
nication protocol conguration, addressing and manual operation. Standard drivers automatically install in
Windows for the LX1 USB AgrowLINK.
Connection to MODBUS RTU
RS-485 / RS-422
Use the LX2 ModLINK to connect MODBUS devices to the GrowNET™ port.
RJ45/CAT5
7 - 24 Vdc
3.3/5Vdc Serial Bus Compatible.
Include required bus terminating resistors per EIA standard.
TX/RX+
TX/RX-
PLC
RS-485
LX1
USBGrowNET™ RJ45
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
5
Data registers are 16 bits wide with addresses using the standard MODICON protocol. Floating point values
use the standard IEEE 32-bit format occupying two contiguous 16 bit registers. ASCII values are stored with
two characters (bytes) per register in hexadecimal format. Coil registers are single bit values which control
and indicate the status of a relay; 1 being on and 0 being o.
Register Types
MODBUS Register Map
Parameter Description Type Scale Access Address
Device Address Slave Address Value, 1-247 8 bit R/W 40001
Serial# Serial Number ASCII 8 Char R 40004
DOM Date of Manufacture ASCII 8 Char R 40008
HW Version Hardware Version ASCII 8 Char R 40012
FW Version Firmware Version ASCII 8 Char R 40016
Timeout (seconds) Turn o relay if no comms Value 16 bit R/W 41001
Relay 1 Count Operation Cycle Count Value 32 bit R 49001
Relay Coil 1 Relay Coil Coil 1 bit R/W 1
0x01 Read Coils
0x03 Read Multiple Registers
0x05 Write Single Coil
0x06 Write Single Register
A request to use a function that is not available will return an illegal function exception.
Supported Commands
Serial Speed & Format
The default serial data format for the LX2 ModLINK interface is: 19,200 baud, 8-N-1.
Alternate speeds and formats between 9,600 - 115,200 baud may be congured with the free AgrowLINK PC
utility using a LX1 USB AgrowLINK and the cross-over adapter supplied with the LX2 ModLINK.
MODBUS Manual
See MODBUS manual for more information.
LX2 ModLINK™LX1 USB AgrowLINK™
GrowNET™
Cross-Over
7 - 24 Vdc
USB
A request to read or write a register that is not available will return an illegal address exception.
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
6
Technical Information
Agrowtek Inc. warrants that all manufactured products are, to the best of its knowledge, free of defective material and workman-
ship and warrants this product for 1 year from the date of purchase. This warranty is extended to the original purchaser from the
date of receipt. This warranty does not cover damages from abuse, accidental breakage, or units that have been modied, altered,
or installed in a manner other than that which is specied in the installation instructions. Agrowtek Inc. must be contacted prior to
return shipment for a return authorization. No returns will be accepted without a return authorization. This warranty is applicable
only to products that have been properly stored, installed, and maintained per the installation and operation manual and used for
their intended purpose. This limited warranty does not cover products installed in or operated under unusual conditions or envi-
ronments including, but not limited to, high humidity or high temperature conditions. The products which have been claimed and
comply with the aforementioned restrictions shall be replaced or repaired at the sole discretion of the Agrowtek Inc. at no charge.
This warranty is provided in lieu of all other warranty provisions, express or implied. It is including but not limited to any implied
warranty of tness or merchantability for a particular purpose and is limited to the Warranty Period. In no event or circumstance
shall Agrowtek Inc. be liable to any third party or the claimant for damages in excess of the price paid for the product, or for any
loss of use, inconvenience, commercial loss, loss of time, lost prots or savings or any other incidental, consequential or special
damages arising out of the use of, or inability to use, the product. This disclaimer is made to the fullest extent allowed by law or
regulation and is specically made to specify that the liability of Agrowtek Inc. under this limited warranty, or any claimed exten-
sion thereof, shall be to replace or repair the Product or refund the price paid for the Product.
Warranty
Exterior Cleaning
Exterior may be wiped with a damp cloth wish mild dish detergent, then wiped dry. Disconnect power be-
fore cleaning the enclosure to prevent electrical shock.
Fuse Replacement
There are no fuses or servicable components inside the RX1i. Do not open the enclosure.
Maintenance & Service
Storage and Disposal
Relays are not activating, no power LED on PCB
Ensure the relay is plugged into 120VAC outlet and the power is on to the outlet.
Relays are clicking but no power to an outlet
Check the status LED to determine if AC power is reaching the line terminal of the receptacle. The red LED is
powered by AC voltage from the line voltage terminal of the receptacle and will only illuminate if voltage is
passed through the relay to the terminal. If the status LED for the receptacle is on, check the equipment by
bypassing the relay.
Troubleshooting
Storage
Store equipment in a clean, dry environment with ambient temperature between 10-50°C.
Disposal
This indsutrial control equipment may contain traces of lead or other metals and environmental contami-
nants and must not be discarded as unsorted municipal waste, but must be collected separately for the
purpose of treatment, recovery and environmentally sound disposal. Wash hands after handling internal
components or PCB’s.