VOLTCRAFT 120747 CAT II 250 V Manuel utilisateur

Taper
Manuel utilisateur
Bedienungsanleitung
Multitester MS-18/2
Best.-Nr. 120747 Seite 2 - 10
Operating Instructions
Multitester MS-18/2
Item No. 120747 Page 11 - 18
Notice d’emploi
Multitesteur MS-18/2
N° de commande 120747 Page 19 - 27
2
Inhaltsverzeichnis
Seite
1. Einführung ...........................................................................................................................................................3
2. Symbol-Erklärung ................................................................................................................................................3
3. Bestimmungsgemäße Verwendung .....................................................................................................................4
4. Produktbeschreibung ........................................................................................................................................... 4
5. Lieferumfang ........................................................................................................................................................ 5
6. Sicherheitshinweise ............................................................................................................................................. 5
7. Einzelteilbezeichnung .......................................................................................................................................... 6
8. Bedienung ............................................................................................................................................................6
a) Einlegen der Batterien/Batteriewechsel .........................................................................................................6
b) Selbsttest .......................................................................................................................................................7
c) Wechselspannungs-Detektion ...................................................................................................................... 7
d) Gleichspannungstest (1,2 bis 35 VDC) .........................................................................................................8
e) Durchgangsprüfung 0 – 5 MOhm (direkter Kontakt) ......................................................................................8
f) Mikrowellenleck-Test ( > 5 mW/cm2)..............................................................................................................9
9. Wartung und Reinigung .......................................................................................................................................9
10. Entsorgung ..........................................................................................................................................................9
a) Allgemein ...................................................................................................................................................... 9
b) Entsorgung von gebrauchten Akkus ..............................................................................................................9
11. Technische Daten ..............................................................................................................................................10
3
1. Einführung
Sehr geehrter Kunde,
wir bedanken uns für den Kauf des Multitesters.
Mit diesem Gerät haben Sie ein Produkt erworben, welches nach dem heutigen Stand der Technik gebaut wurde. Die-
ses Produkt erfüllt die Anforderungen der geltenden europäischen und nationalen Richtlinien. Die Konformität wurde
nachgewiesen, die entsprechenden Erklärungen und Unterlagen sind beim Hersteller hinterlegt.
Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen, müssen Sie als Anwender diese
Bedienungsanleitung beachten!
Bei technischen Fragen wenden Sie sich bitte an:
Deutschland: www.conrad.de
Österreich: www.conrad.at
Schweiz: www.conrad.chr
2. Symbol-Erklärung
Das Symbol mit dem Ausrufezeichen im Dreieck weist auf wichtige Hinweise in dieser Bedienungsanlei-
tung hin, die unbedingt zu beachten sind.
 DasPfeil-Symbolistzunden,wennIhnenbesondereTippsundHinweisezurBedienunggegebenwerden
sollen.
4
3. Bestimmungsgemäße Verwendung
Die bestimungsgemäße Verwendung des Gerätes umfaßt:
Testen von Wechselspannung:
- direkte Messung 70 – 250 V AC
- IndirekteMessung70–500VAC
Polaritätsprüfung 1,2 V bis 36 V DC (Gleichspannung)
Durchgangsprüfung ca. 0 bis 5 MOhm
Testen von Mikrowellen- und Fernsehgeräten auf Abstrahlung
Gebrauch nur in trockener Umgebung
Eine andere Verwendung als zuvor beschrieben führt zur Beschädigung dieses Produktes, darüber hinaus
ist dies mit Gefahren, wie z.B. Kurzschluß, Brand, elektrischer Schlag etc. verbunden. Das gesamte Pro-
dukt darf nicht geändert bzw. umgebaut und das Gehäuse nicht geöffnet werden!
Die Sicherheitshinweise sind unbedingt zu beachten!
4. Produktbeschreibung
Mit dem Multitester MS18-2 ist die technische Weiterentwicklung des erfolgreichen MS 18. Neben den Funktionen des
MS-18 wurde der MS 18-2 mit einer stromsparenden Messelektronik ausgestattet, durch welche der Stromverbrauch
um bis zu 70% gesenkt werden konnte. Weiterhin ist der MS18-2 mit eine Temporären Speicherfunktion ausgestattet,
welche die LED-Anzeige noch 0,5 bis 2 Sekunden verzögert um eine exaktes und eindeutiges Messergebnis zu
erreichen.
Mit dem MS 18-2 können Sie an spannungsführenden Leitungen und Teilen überprüfen, ob Wechselspannung an-
liegt.DiekannsowohlimdirektenKontaktoderauchberührungslos(indirekt)erfolgen.DieIndirekteMessungist
vor allem bei isolieren Leitungen und Teilen sehr hilfreich. Weiterhin kann die Polarität von Gleichspannungsquellen
ermittelt werden. Bei Verwendung als Durchgangsprüfer können Sie im spannungslosen Zustand Leiterbahnen, Mas-
severbindungen, Sicherungen, Netzkabel, Glühbirnen, Schalter uvm. auf Funktion (Durchgang) prüfen. Ein weiteres
Einsatzgebiet ist das Testen von Komponenten wie Dioden, Gleichrichter, Kondensatoren, Transistoren (NPN/PNP),
Spulen etc. als auch das Überprüfen von Mikrowellengeräten auf undichte Stellen. Die Anzeige erfolgt über eine
eingebaute rote LED.
5
5. Lieferumfang
Multitester MS 18-2
zwei Knopfzellen
Bedienungsanleitung
Aktuelle Bedienungsanleitungen
Laden Sie aktuelle Bedienungsanleitungen über den Link www.conrad.com/downloads herunter
oder scannen Sie den abgebildeten QR-Code. Befolgen Sie die Anweisungen auf der Webseite.
6. Sicherheitshinweise
Bei Schäden, die durch Nichtbeachten dieser Bedienungsanleitung verursacht werden, erlischt der
Garantieanspruch! Für Folgeschäden übernehmen wir keine Haftung!
Ein in einem Dreieck bendliches Ausrufezeichen weist auf wichtige Hinweise in der Bedienungs-
anleitung hin. Lesen Sie vor Inbetriebnahme die Anleitung komplett durch.
Aus Sicherheits- und Zulassungsgründen ist das eigenmächtige Umbauen und/oder Verändern des
MS18-2 nicht gestattet.
Überschreiten Sie niemals die maximalen Eingangsgrößen.
Eine zuverlässige Anzeige ist nur in einem Temperaturbereich von –10 °C bis +50 °C und in einem Fre-
quenzbereich von 50 Hz bis 500 Hz gewährleistet. Der Tester darf nur in trockenen und geschlossenen
Räumen benutzt werden. Vermeiden Sie jeden Kontakt mit Feuchtigkeit.
Benutzen Sie den Tester niemals dann, wenn er Schäden aufweist. Vor jedem Einsatz muß das Gerät
auf Funktion geprüft werden.
IngewerblichenEinrichtungensinddieUnfallverhütungsvorschriftendesVerbandesdergewerblichen
Berufsgenossenschaften für elektrische Anlagen und Betriebsmittel zu beachten.
Statische Elektrizität, z.B. erzeugt durch starkes Reiben am Plastikgehäuse, kann die Anzeige verfäl-
schen.
Dieser Tester gehört nicht in Kinderhände.
Der Multitester ist zur Verwendung als Schraubendreher nicht geeignet.
Seien Sie besonders vorsichtig bei Spannungen größer 25 V/AC oder 35 V/DC. Bereits bei diesen Span-
nungen können Sie bei Berührung einen lebensgefährlichen elektrischen Schlag erleiden.
Dieser Tester darf nur in Stromkreisen eingesetzt werden, die selbst mit 10 A abgesichert sind (bzw.
keine Leistungen größer 4000 VA auftreten).
Sollten sich bei Fragen ergeben die nicht durch diese Bedienungsanleitung nicht beantwortet werden
können, setzen Sie sich mit einem Fachmann oder unserer telefonischen Kundenbetreuung in Verbin-
dung.
6
7. Einzelteilbezeichnung
1 Messspitze
2 Anzeige LED
3 Batteriefachdeckel
8. Bedienung
a) Einlegen der Batterien/Batteriewechsel
Der Multitester benötigt zum Betrieb zwei Knopfzellen des Typs 392A, AG3, LR41, 192 (oder baugleich).
Um einen elektrischen Schlag zu vermeiden, darf der Multitester nicht in geöffneten Zustand betrieben
werden. Nach jedem Batteriewechsel muss ein Selbsttest durchgeführt werden.
Zum Wechsel der Batterie gehen Sie wie folgt vor:
Öffnen Sie mit einem geeigneten Schraubendreher das Batteriefach (3) am Ende des Griffes. Öffnen = Drehung
nach links (entgegen dem Uhrzeigersinn). Siehe hierzu nachfolgende Abbildung.
Nehmen Sie den Batteriefachdeckel (3) heraus. Biegen Sie den Drahtbügel, welcher die Knopfzellen festhaltet,
vorsichtig zur Seite.
Entnehmen Sie jetzt die leeren Knopfzellen und ersetzen Sie diese durch zwei neue gleichen Typs. Beachten Sie
unbedingt die Polarität der Knopfzellen.
Biegen Sie den Draht wieder vorsichtig zurück in die Ausgangsposition.
Setzen Sie die Schraube wieder in das Gerät. Die Schraube mit Gefühl anziehen. Schließen = Drehung nach
rechts (im Uhrzeigersinn).
Lassen Sie Batterien nicht offen herumliegen. Es besteht die Gefahr, dass diese von Kindern verschluckt
werden. Ausgelaufene oder beschädigte Batterien können bei der Berührung mit der Haut Verätzungen
verursachen. Versuchen Sie nie Batterien aufzuladen. Werfen Sie keine Batterien ins Feuer!
7
b) Selbsttest
Um Fehlindikationen zu vermeiden, muss vor jedem Gebrauch und nach jedem Batteriewechsel die Funktionsfähig-
keit des Multitesters durch einen Selbsttest überprüft werden. Überprüfen Sie vor jedem Gebrauch das Gerät auf
Beschädigung(en) wie z.B. Gehäusebruch usw.
Berühren Sie die Spitze (1) des Testers mit einer Hand und gleichzeitig mit der ande-
ren Hand den Batteriefachdeckel (3)
Wenn die rote LED (2) zu blinken beginnt, ist der Multitester in Ordnung und darf
benutz werden.
Sollte die rote LED nicht blinken, darf das Gerät nicht benutzt werden. Wech-
seln Sie ggf. die Batterien.
c) Wechselspannungs-Detektion
1direkter Kontakt (70 bis 250 V Wechselspannung)
Berühren Sie mit der Messspitze (1) den Elektrischen Leiter (Phase). Leuchtet die LED (2) auf, ist Spannung vor-
handen.
Bei diesem Test darf der Batteriefachdeckel nicht mit dem Finger berührt werden.
2Indirekter Kontakt (70 bis 500 V Wechselspannung)
Bei diesem Test darf die Spitze des Testers die zu prüfende Leitung (Gerät) nicht direkt berühren.
Bitte beachten Sie, dass durch die Temporäre Speicher- funktion die LED (2) erst ca. 0,5 bis 2 Sekunden
nach Entfernen des Gerätes von der Spannung erlischt.
Führen Sie die Messspitze des MS18-2 entlang eines elektrischen Kabels, Steck-
dose oder Gerätes.
IstSpannungvorhanden(SteckerinderSteckdose,Geräteingeschaltetusw.)be-
ginnt die LED (2) zu blinken. Auf diese Weise können Sie einfach und schnell z.B.
Unterbrechungen in Kabeln usw. feststellen.
 ZurErhöhungderEmpndlichkeitkannderBatteriefachdeckelmitdem
Finger berührt werden.
Dieser Test kann nicht bei geschirmten Kabeln durchgeführt werden.
Zum Schnelltest von Steckdosen, Netzgeräten oder PVC isolierten Kabeln halten
Sie den MS18-2 an der Messspitze (1) und führen den Griff in die Nähe des zu
überprüfenden Gerätes.
IstSpannungvorhandenbeginntdieLED(2)zublinken.
8
d) Gleichspannungstest (1,2 bis 35 VDC)
MitdieserFunktionidentiziertderMS18-2diePolaritätvonGleichspannungsquellenwieBatterien,Akkus,usw.
Berühren Sie mit einem Finger einen Pol der zu Überprüfenden Batterie. Berühren Sie mit der Messspitze (1) den
anderen Pol der Batterie (Batteriefachdeckel berühren).
Beginnt die LED (2) zu leuchtet oder blinken, ist der Pol welcher mit der Messspitze verbunden ist der Plus-Pol, bleibt
die LED dunkel berühren Sie den Minus Pol.
„+“ Pol, LED leuchtet oder blinkt „-“ Pol, LED dunkel
e) Durchgangsprüfung 0 – 5 MOhm (direkter Kontakt)
Achtung!
Lebensgefahr durch elektrischen Schlag!
Das zu prüfende Objekt muss unbedingt spannungsfrei geschaltet, elektrische Bauteile ausgebaut sein.
Geräte die mit Batterien, Akkus oder einem Netzgerät betrieben werden, müssen von der Spannungsver-
sorgung getrennt werden. Bei 230 V-Wechselspannungsgeräten muss der Netzstecker gezogen werden.
Bei 230 V-Leitungen muss die Hauptsicherung abgeschaltet und gegen unbefugtes Wiedereinschalten
gesichert werden. Evtl. eingebaute Kapazitäten müssen entladen werden.
Berühren Sie mit einer Hand den Batteriefachdeckel (3) und mit der anderen Hand
einen Kontakt des zu prüfenden Bauteils (z.B. Glühbirne).
Führen Sie die Spitze des Multitesters an den anderen Kontakt. Beginnt die LED (2)
zu leuchten oder blinken, ist Durchgang vorhanden, bzw. die Glühbirne ist in Ordnung.
Der Multitester erkennt Widerstände bis 50 MOhm. Mit dieser Funktion können Sie
einfach und unkompliziert Sicherungen, Widerstände (bis 50 MOhm), Heizelemente,
elektrische Bauteile wie Kondensatoren, Transistoren, Dioden, Spulen usw. testen.
Praxis-Hinweis!
Eine Diode ist in Ordnung, wenn in Durchlassrichtung (Finger an Kathode, Testspitze an Anode) die LED zu
leuchten oder blinken beginnt, in Sperrichtung die LED dunkel bleibt.
Ein NPN-Transistor ist in Ordnung, wenn die LED zu leuchten oder blinken beginnt sobald Sie mit der Testspitze
den Emitter oder Kollektor berühren und gleichzeitig mit dem Finger die Basis angetippt wird.
Ein PNP-Transistor ist in Ordnung, wenn die LED zu leuchten oder blinken beginnt sobald Sie mit der Testspitze
die Basis berühren und gleichzeitig mit dem Finger den Emitter oder Kollektor antippen.
9
f) Mikrowellenleck-Test ( > 5 mW/cm2)
Achtung!
Mikrowellenstrahlung ist gefährlich! Dieser Tester ist nicht mit einem Hightech-Gerät vergleichbar. Solche
Messgeräte kosten ein Vielfaches mehr. Betrachten Sie daher diesen Test nur als Anhaltspunkt für evtl.
vorhandene Mikrowellenstrahlung.
SchaltenSieIhreMikrowelleein.
Berühren Sie mit einer Hand den Batteriefachdeckel (3) und führen Sie die Testspitze des Multitesters langsam an
derTürderMikrowelleentlang.IstdieTürdichtungderMikrowelleundicht,beginntdieLEDzublinken.In diesem
Fall darf die Mikrowelle nicht mehr betrieben werden. Bringen Sie das Gerät zu einem Fachhändler!
9. Wartung und Reinigung
Trennen Sie den Multitester vor einer Reinigung oder Wartung von allen Stromversorgungen. Zur äußerlichen Rei-
nigung verwenden Sie lediglich ein weiches, trockenes Reinigungstuch. Verwenden Sie auf keinen Fall Feuchtigkeit
oder Reinigungsmittel. Eine Wartung oder Reparatur darf nur durch eine Fachkraft erfolgen, die mit den einschlägigen
Vorschriften (VDE 100, VDE 0701) vertraut ist.
10. Entsorgung
a) Allgemein
Das Produkt gehört nicht in den Hausmüll.
Entsorgen Sie das Produkt am Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Vorschriften;
geben Sie es z.B. bei einer entsprechenden Sammelstelle ab.
Entnehmen Sie die eingesetzten Batterien bzw. Akkus und entsorgen Sie diese getrennt vom Produkt.
b) Entsorgung von gebrauchten Akkus
SiealsEndverbrauchersindgesetzlich(Batterieverordnung)zurRückgabeallergebrauchtenAkkusverpichtet;eine
Entsorgung über den Hausmüll ist untersagt!
Schadstoffhaltige Akkus sind mit nebenstehendem Symbol gekennzeichnet, die auf das Verbot der Entsor-
gung über den Hausmüll hinweisen.
Die Bezeichnungen für das ausschlaggebende Schwermetall sind: Cd = Cadmium, Hg = Quecksilber, Pb =
Blei.IhreverbrauchtenAkkuskönnenSieunentgeltlichbeidenSammelstellenIhrerGemeinde,unseren
Filialen oder überall dort abgeben, wo Akkus verkauft werden.
SieerfüllendamitdiegesetzlichenVerpichtungenundleistenIhrenBeitragzumUmweltschutz!
10
11. Technische Daten
Spannungsversorgung .....................................3 V (2 x 1,5 V Knopfzelle)
Batterietyp ........................................................392A, AG3, LR41, 192 (oder baugleich)
Schutzklasse ....................................................2 (Schutzisoliert)
Überspannungskategorie .................................CATII
Spannungsmessbereich ...................................direkt 70 V bis 250 VAC
Wechselspannung ............................................indirekt 70 V bis 500 VAC
Polaritätsprüfung ..............................................1,2 V bis 35 V DC (Gleichspannung)
Frequenzbereich ..............................................50 bis 500 Hz
Durchgangsprüfung ..........................................0bis50MΩ
Mikrowellenlecktester .......................................>5 mW/cm2
Arbeitstemperatur .............................................-10 °C bis +50 °C
Abmessungen (L x Ø ) ......................................140 x 21 mm
11
Table of contents
Page
1. Introduction ........................................................................................................................................................ 12
2. Explanation of symbols ...................................................................................................................................... 12
3. Intendeduse ...................................................................................................................................................... 12
4. Product description ............................................................................................................................................ 13
5. Delivery content ................................................................................................................................................. 13
6. Safety instructions .............................................................................................................................................14
7. Description of individual components ................................................................................................................14
8. Operation ........................................................................................................................................................... 15
a) Insertingthebattery/Changingofbattery ..................................................................................................15
b) Self-test .......................................................................................................................................................15
c) Alternating voltage detection .......................................................................................................................16
d) Direct voltage test (1.2 to 35 VDC) .............................................................................................................. 16
e) Continuity check 0 – 5 MOhm (direct contact) .............................................................................................17
f) Practice note! ...............................................................................................................................................17
g) Microwave leak test ( > 5 mW/cm2) .............................................................................................................17
9. Maintenance and care .......................................................................................................................................17
10. Disposal ............................................................................................................................................................. 18
a) General ........................................................................................................................................................18
b) Disposal of spent rechargeable batteries ....................................................................................................18
11. Technical data ....................................................................................................................................................18
12
1. Introduction
Dear customer,
Thank you for your purchasing the multitester.
Withthisproductyouhaveboughtastateoftheartproduct.Thisproductsatisesthestandardsoftheestablished
European and national guidelines. CE-conformity has been proven, the relevant documents are in the manufacturer’s
possession. We kindly request the user to respect this operating manual to preserve this condition and to ensure safe
operation.
Ifthereareanytechnicalquestions,pleasecontact:
www.conrad.com/contact
2. Explanation of symbols
The symbol with the exclamation mark in the triangle is used to indicate important information in these
operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on operation.
3. Intended use
The agreed upon use of the device covers:
Testing of alternating voltage:
- direct measuring 70 – 250 V AC
- indirect measuring 70 – 500 V AC
Polarity check 1.2 V to 36 V DC (direct voltage)
Continuity check approx. 0 to 5 MOhm
Testing of microwaves and televisions for radiant emittance
Use only in dry environment
Any use other than the one previously described can lead to damages on the product. Moreover, this in-
volvesdangers,suchase.g.,short-circuit,re,electricshock,etc.Nopartoftheproductmaybemodied
or rebuilt and the housing must not be opened.
Always observe the safety instructions and technical data.
13
4. Product description
The multitester MS18-2 is the further technical development of the successful MS 18. Next to the functions of the
MS-18 the MS 18-2 has also been equipped with power saving measuring electronics, through which the current
consumption could be lowered by 70 percent. MS18-2 furthermore has a temporary memory function which delays the
LEDdisplayafurther0.5to2secondsinordertoachievepreciseanddenitemeasuringresults.
With the MS 18-2 you can check voltage-carrying electric lines and part, whether alternating voltage is applied. This
can be carried out either with direct contact or contactless (indirect). The indirect measuring can be especially helpful
with insulated lines and parts. Moreover, the polarity of direct voltage sources can be determined. When using the
device as a continuity tester for circuit track conductors, chassis earth connections, fuses, power cords, light bulbs,
switches and many more can be tested on their function (continuity) when off circuit. A further area of use is the test-
ingofcomponentssuchasdiodes,rectiers,condensers,transistors(NPN/PNP),coils,etc.butalsothetestingof
microwaves for leakage. The display is via a built-in red LED.
5. Delivery content
Multitester MS 18-2
two round cell batteries
Operating instructions
1Up-to-date operating instructions
Download the latest operating instructions via the link www.conrad.com/downloads or scan the
QR code. Follow the instructions on the website.
14
6. Safety instructions
In the case of any damages which are caused due to failure to observe these operating instructions,
the guarantee will expire. We do not assume liability for resulting damages.
An exclamation mark inside a triangle points to important notes in the operating manual. Please
read through the entire manual before putting the device into operation.
Theunauthorisedconversionand/ormodicationoftheMS18-2isnotpermittedbecauseofsafetyand
approval reasons.
Never exceed the maximum input quantities.
A reliable display is only ensured at a temperature range of –10 °C to +50 °C and a frequency range of
50 Hz to 500 Hz. The tester is only authorized for the use in closed and dry rooms.
Avoid all contact to dampness
Never use the tester if there are any visible damages. Before each use the device needs to be checked
if it works correctly.
Incommercialandindustrialfacilitiestheregulationsforthepreventionofaccidentsoflaiddownbythe
professional trade association for electrical equipment and devices need to be observed.
Static electricity e.g., caused by strong rubbing on the plastic housing, can falsify the reading.
This tester should be kept out of reach of children.
The multitester is not suitable to be used as a screwdriver. Be especially careful with voltages larger
than 25 V AC or 35 V DC. With voltages like this you can already suffer a life-threatening electric shock.
This tester can only be used in electrical circuits which are protected with 10A (and/or no capacities
largerthan4000VAappear).Inthecaseofanyquerieswhichcouldnotbeansweredbytheseoperating
instructions, please a consult specialist or contact our customer service by phone.
7. Description of individual components
1 Measuring tip
2 LED display
3 Battery compartment lid
15
8. Operation
a) Inserting the battery / Changing of battery
To operate the multitester two round cell batteries type 392A, AG3, LR41, 192 (or identically constructed) are needed.
To avoid an electric shock the multitester must not be operated when open. After each battery change a
self-test needs to be carried out.
To change the batteries you need to:
Open the battery compartment at the end of the grip with a suitable screwdriver (3). Opening = turn left (anti-
clockwise). Also see illustration below.
Take out the battery compartment lid (3). Carefully bend back the wire clip which holds the round cell batteries.
Now take out the empty round cell batteries and replace them with two new others of the same type. Take care to
observe the polarity of the round cell batteries.
Carefully bend back the wire in its original position.
Put the screw back into the device. Carefully tighten the screw. Closing = turn right (clockwise).
 Donotletbatteriesliearoundopenly.Thereistheriskofbatteriesbeingswallowedbychildren.Insuch
case, seek instant medical care. Do not let batteries lie around openly. There is the risk of batteries be-
ingswallowedbychildren.Insuchcase,seekinstantmedicalcare.Leakingordamagedbatteriesmight
cause acid burns when getting into contact with skin, therefore use suitable protective gloves. Never try to
rechargebatteries.Donotthrowbatteriesintore.
b) Self-test
To avoid wrong readings, the operability of the multitester needs to be checked by a self-test before each use and
after each change of batteries. Please check the device for damage(s) such as e.g., breaks on the housing etc.
Touch the tip (1) of the tester with one hand and at the same time touch the battery
compartment lid (3) with the other hand.
When the red LED (2) starts blinking, the multitester is in working order and can be
used.
In case the red LED does not blink, the device must not be used. If necessary
change the batteries.
16
c) Alternating voltage detection
1Direct contact (70 to 250 V alternating voltage)
Touchtheelectricconductor(phase)withthemeasuringtip(1).IftheLED(2)lightsup,thereisvoltage.
 Duringthistestthebatterycompartmentlidmustnotbetouchedwiththenger.
2Indirect contact (70 to 500 V alternating voltage)
During this test the tip of the tester must not touch the tested line (device) directly.
Please note that the LED (2) only goes out after approx. 0.5 to 2 seconds after removing the device from
the voltage because of the temporary memory function.
Guide the measuring tip of the MS18-2 along an electric cable, electrical outlet or
the device.
Ifthereisvoltage,(pluginsocket,deviceswitchedon,etc.)theLED(2)startsblink-
ing.Inthiswaye.g.,interruptionsincablesetc.canbedetectedsimplyandquickly.
 Toincreasethesensitivity,thebatterycompartmentlidcanbetouchedwiththenger.
This test can not be carried out with shielded cables.
To carry out a quick test on electrical outlets, power supply units or PVC insulated
cables hold the MS18-2 on the measuring tip (1) and guide the grip near the device
to be tested.
Ifthereisvoltage,theLED(2)willstartblinking.
d) Direct voltage test (1.2 to 35 VDC)
WiththisfunctiontheMS18-2identiesthepolarityofdirectvoltagesourcessuchasbatteries,rechargeablebatteries,
etc.Touchthepoleofthebatterytobetestedwithonenger.Touchtheotherpoleofthebatterywiththemeasuring
tip (1) (touch battery compartment lid).
IftheLED(2)startstolightuporblink,thepolewithwhichthemeasuringtipisconnected,isthepositivepole.Ifthe
LED stays dark, touch the minus pole.
„+“ Pole, LED light up or blink „-“ Pole, LED dark
17
e) Continuity check 0 – 5 MOhm (direct contact)
Touch the battery compartment lid (3) with one hand and with the other hand the
contact of the component to be tested (e.g., light bulb). Guide the tip of the multit-
estertoanothercontact.IftheLED(2)startstolightuporblink,continuityisgiven
and the light bulb is in working order. The multitester recognises resistances up to
50 MOhm. With this function you can test fuses, resistances, (up to 50 MOhm), heat-
ing elements, electrical components such as condensers, transistors, diodes, coils,
etc. simply and easily.
f) Practice note!
AdiodeisinworkingorderiftheLEDstartstolightuporblinkinconductingdirection(ngeroncathode,testtip
on anode), the LED remains dark in reverse direction.
A NPN transistor is in working order if the LED starts to light up or blink as soon as the test tip of the emitter or the
collectorgetstouchedwhilethengertapsthebaseatthesametime.
A PNP transistor is in working order if the LED starts to light up or blink as soon as the test tip on the base is
touchedwhileatthesametimetappingtheemitterorthecollectorwiththenger.
g) Microwave leak test ( > 5 mW/cm2)
Caution!
Microwave radiation is dangerous. This tester can not be compared with a high-tech device. The cost for
measuring devices like this are much larger. This is why you should see this test only as an indication for
possibly existing microwave radiation.
Switch your microwave on
Touch the battery compartment lid (3) with one hand and guide the test tip of the multitester slowly along the door
ofthemicrowave.Ifthedoorsealisleaky,theLEDwillstartblinking.If this is the case, the microwave must not
be operated anymore. Take the device to a specialist.
9. Maintenance and care
Separate the multitester from all power supplies before cleaning it or carrying out maintenance. To clean the outside,
only use a soft, dry cleaning cloth. Do not get is damp or use cleaning agents. Maintenance or repairs may only be
carried out by an expert who is familiar with the relevant regulations (VDE 100, VDE 0701) (VDE mark of conformity).
18
10. Disposal
a) General
The product must not be disposed in the household waste.
Dispose of the product at the end of its serviceable life in accordance with the current statutory require-
ments; e.g., return it to any suitable collection point.
Remove any normal or rechargeable batteries inserted and dispose of them separately from the product.
b) Disposal of spent rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all spent rechargeable batteries; disposal of
them in the household waste is prohibited!
Contaminated rechargeable batteries are labelled with these symbols to indicate that disposal in the do-
mestic waste is forbidden.
The symbols of the relevant heavy metals are: Cd = Cadmium, Hg = Mercury, Pb = Lead.
You can return used rechargeable batteries free of charge to any collection facility in your local authority, to
our stores or to any other store where rechargeable batteries are sold.
Youtherebyfullyourstatutoryobligationsandcontributetotheprotectionoftheenvironment.
11. Technical data
Voltage supply ..................................................3 V (2 x 1.5 V round cell battery)
Type of battery ..................................................392A, AG3, LR41, 192 (or identically constructed)
Safety class ......................................................2 (totally insulated)
Overvoltage category .......................................CATII
Voltage measurement range ............................direct 70 V to 250 VAC
Alternating voltage ............................................indirect 70 V to 500 VAC
Polarity check ...................................................1.2 V to 35 V DC (direct voltage)
Frequency range ..............................................50 to 500 Hz
Continuity check ...............................................0 to 50 M
Microwave leak tester .......................................>5 mW/cm2
Operating temperature .....................................-10 °C to +50 °C
Dimensions (L x Ø ) ..........................................140 x 21 mm
19
Sommaire
Page
1. Introduction ........................................................................................................................................................ 20
2. Explication des symboles ..................................................................................................................................20
3. Utilisation conforme ...........................................................................................................................................21
4. Description du produit ........................................................................................................................................ 21
5. Contenu de l’emballage ..................................................................................................................................... 22
Modes d‘emploi actuels .....................................................................................................................................22
6. Consignes de sécurité .......................................................................................................................................22
7. Description des éléments ..................................................................................................................................23
8. Mode d’emploi ...................................................................................................................................................23
a) Installationdespiles/Changementdespiles ..............................................................................................23
b) Autocontrôle ................................................................................................................................................24
c) Détection d’une tension alternative .............................................................................................................24
d) Test sur tension continue (1,2 à 35 VCC) ....................................................................................................25
e) Test de continuité électrique 0 – 5 MOhm (contact direct) ..........................................................................25
f) Détection de fuites de micro-ondes ( > 5 mW/cm2) .....................................................................................26
9. Entretien et nettoyage ........................................................................................................................................26
10. Élimination .........................................................................................................................................................26
a) Généralités ..................................................................................................................................................26
b) Élimination des piles rechargeables usées .................................................................................................26
11. Caractéristiques techniques .............................................................................................................................27
20
1. Introduction
Cher client,
nous vous remercions de l’achat du Multitesteur MS-18/2.
Avec ce produit, vous avez fait l’acquisition d’un produit construit d’après les derniers progrès de la technique. Ce
produitestconformeauxexigencesdesdirectiveseuropéennesetnationalesenvigueur.Laconformitéaétévériée
et les notices correspondantes ont été déposées chez le fabricant.
Andemaintenirl’appareilenbonétatetd’enassurerl’exploitationsansrisques,l’utilisateurdoitabsolumenttenir
compte de ce mode d’emploi!
Pour toute question technique, veuillez vous adresser à:
France (email): [email protected]
Suisse: www.conrad.ch
2. Explication des symboles
Dans le présent mode d’emploi, le point d’exclamation précède les indications importantes qui doivent
impérativement être respectées.
 Lesymboledelaècheprécèdelesastucesetindicationsparticulièressurlefonctionnement..
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

VOLTCRAFT 120747 CAT II 250 V Manuel utilisateur

Taper