Extreme Networks Industrial Switches Guide de référence

Taper
Guide de référence
Industrial Switch Series
Quick Reference
Follow these steps to get the switch ready for use.
For complete installation instructions see the ISW Hardware Installation
& User Guide at www.extremenetworks.com/documentation
Necessary Tools
Appropriately grounded power receptacles
located within 1.8 m (6 ft.).
A readily accessible device for disconnecting
power, such as a breaker or primary switch.
Network cabling within reach.
Up to at least 7.6 cm (3.0 in.) on all sides, for
proper ventilation.
Temperature between -40°C (-40°F) and
75°C (167°F) -- or as noted in “Operating Temperature:”-- with
fluctuations of less than 10°C (18°F) per hour.
If the switch appears to be damaged, contact Extreme Networks. See
“Getting Help” for more information.
Extreme Networks does not include power input cords with this product.
To purchase the correct power cord for your country, refer to
http://www.extremenetworks.com/product/powercords/.
DIN-Rail Mount
1 Screw the DIN-Rail bracket on with the bracket and screws in the
accessory kit.
2 Hook the unit over the DIN rail.
3 Push the bottom of the unit towards the DIN Rail until it snaps into
place.
1#2 Phillips screwdriver
(magnetic screwdriver recommended) 2ESD-protective wrist strap
1Prepare the Site
The installation site must meet the following requirements:
2Unpack the Box
Remove the packing material, and verify that all of the
following components are included:
DIN-Rail/Wall Mount Rack Mount
Management Ethernet switch 1 1
Wall-mount plates 2 n/a
DIN-RAIL clip 1 n/a
19” Rack mount brackets n/a 2
M3 Screws (for the wall mount plates
& DIN-RAIL clip or rack mount) 4 8
DC power terminal block 1 1
Console cable 1 1
QRG (this document) 1 1
RJ45 Ethernet port
Dust Cover SFP Ethernet port
Dust Cover Earth Ground
Screw
ISW-4W-4WS-4X 8 8 M4
ISW-24W-4X 24 4 M4
16801 3 2 M3
16802 4 4 M3
16803 3 2 M3
16804 4 4 M3
3Install the Industrial Switch Series switch
The 8-port and 12-port switch models can only be DIN-Rail
mounted or wall mounted.
Note: The ISW-24W-4X switch can be installed in a standard
two-post equipment rack. It does not support Din Rail or
Wall Mount options.
Wall Mount
Attach the wall-mounting plates with the screws provided in the
accessory kit.
Note: Wall anchors and wood screws are not provided.
Two-Post Mount
This procedure uses the two-post mounting kit.
1 Attach a rack ear to one side of the switch, screwing it into the holes
so that the flange (ear) is flush with the front of the switch.
2 Attach the other rack ear to the other side.
3 Attach the rack ears to the front rack posts, using the screws (rack
post screws not provided).
Connect to the primary power source
To attach your switch to a power source, do the following:
1 Verify that the power source circuit is de-energized.
2 Connect the DC outlets on the power supply to the DC power inlets
on the rear or the top of the switch.
3 Connect the AC power inlets on the power supply to the AC power
source.
4 Energize the circuit.
5 When power is connected, verify that the switch’s PWR LED turns
green. If the PWR LED does not turn green, refer to ISW Series
Hardware Installation Guide for troubleshooting information.
4Connect Power
Extreme Networks Industrial Switches support dual DC power
input. Extreme Networks also offers power supplies that
accept AC input and provide DC output for use by the
switches. Refer to the Hardware Install & User Guide for more
information on DC input rating of the Switches, and the AC
Input and DC Output rating of the power supplies.
Note: Installing the system as described in this guide meets the
protective earth grounding requirements of the National
Electrical Code (NEC), UL/CSA/IEC/EN 60950-1/UL/CSA/IEC/
EN -62368-1 standards. Ensure that the provided earth ground
screw (either M4 or M3) on the system is used to connect to an
earth ground using the green-and-yellow 16 AWG ground wire.
Note: The power supplies must be installed by qualified
personnel such as licensed electricians, in accordance with local
electrical codes, and connected to a well fused power source.
5Update and Configure the Switch
Upgrade to a generally available (GA) version of the
software before you use this unit. For more information,
see ISW Hardware Installation & User Guide.
Safety Notices
Hardware Components
Figure 1 Industrial Series: 12-Port PoE Series Front Panel
Figure 2 Industrial Series: 12-Port PoE Series Top Panel
Figure 3 Industrial Switch Series: 28-Port PoE Series Front Panel
Electrical Hazard: Only qualified instructed or skilled personnel should perform
installation, repair, or disassembly procedures.
Risques d’électrocution: Seul un personnel qualifié ou expérimenté peut
effectuer les procédures d'installation, de réparation ou de démontage.
Warning: Extreme Networks power supplies do not have switches for turning
the unit on and off. Before servicing, disconnect all power cords to remove
power from the device. Make sure that these connections are easily accessible.
Avertissement: Les alimentations d’Extreme Networks n’ont pas d’interrupteurs
pour allumer ou éteindre l'appareil. Avant l'entretien, débranchez tous les
cordons d'alimentation pour couper l'alimentation de l'appareil. Assurez-vous
que ces connexions sont facilement accessibles.
Warning: This equipment is designed for installation in restricted access
locations and suitable for installation in Information Technology Rooms in
accordance with Article 645 of the National Electrical Code and NFPA 75, not
suitable for use in locations where children are likely to be present.
Avertissement: Cet équipement est conçu pour être installé dans des endroits
à accès restreint et peut être installé dans des salles informatiques
conformément à l'article 645 du Code national de l'électricité et à la norme
NFPA 75, et ne peut être installé dans des endroits où des enfants sont
susceptibles d'être présents.
Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each
power supply connection.
Avertissement: Un disjoncteur certifié 15A et dédié à l'installation doit être
utilisé pour chaque connexion d'alimentation.
Caution: Before mounting the device, ensure that the rack can support it
without compromising stability. Otherwise, personal injury or equipment
damage may result.
Caution: Follow appropriate ESD procedures when unpacking and handling
the switch. These include unpacking the switch in an ESD-safe environment
and wearing appropriate ESD protective gear, such as ESD-safe footwear and
ESD wrist straps where appropriate.
Caution: Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Warning: Do not use optical instruments to view the laser output. The use of
optical instruments to view laser output increases eye hazard. Use only
UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.
Avertissement: Ne pas utiliser d'instruments optiques pour mesurer la
puissance laser. L'utilisation d’instruments optiques pour mesurer la puissance
laser peut augmenter les risques de dommages oculaires. Utilisez uniquement
des modules certifiés UL/CSA,
IEC/EN60825-1 /-2.
1Combo ports:
10/100/1000BASE-T 90W 802.3bt
PoE ports or 1000BASE-X (SFP)
ports
210GBASE-X SFP+ ports
3System status LEDs
4Device info/status
510/100/1000BASE-T 90W PoE
802.3bt ports
6Port LEDs
7USB Type A port
1Dual power input (6p terminal
block)
2RJ45 serial console port
3Reset
4Grounding lug
1USB Type A port 5Device info/status
210/100/1000BASE-T OOB management
port 6System status LEDs
Figure 4 Industrial Series: 28-Port PoE Series Rear Panel
Figure 5 Industrial Switch Series: 8-Port PoE Series Front Panels
Figure 6 Industrial Switch Series: 12-Port PoE Series Front Panels
Figure 7 Industrial Switch Series: Top Panel of All 8-Port and 12-Port
Models
For component details, see ISW Hardware Installation & User Guide.
Operating Conditions
Operating Temperature:
-40°C (-40°F) to 75°C (167°F)
Temperature restrictions might apply. See ISW Series Hardware
Installation Guide for details.
Storage Temperature:
-40°C to 85°C (-40°F to 185°F)
Operating Relative Humidity:
5% to 95% (non-condensing)
310/100/1000Base-T PoE 802.3bt ports 7RJ-45 serial console port
4SFP+ ports (1/2.5/10G) 8Reset
1Dual power input (4p terminal block) 2Grounding lug
1PoE LEDs
2System status LEDs
310/100 Ethernet Copper Ports
4Gigabit Ethernet SFP Ports
5Device info/status
6Gigabit Ethernet SFP ports
7Gigabit Ethernet Copper Ports
1PoE LEDs
2System status LEDs
310/100 Ethernet Copper Ports
4Gigabit Ethernet SFP ports
5Device info/status
6Gigabit Ethernet Copper Ports
1Dual power input (6p terminal
block)
2RJ45 serial console port
3Reset
4Grounding lug
Note: The operating temperature range is -40°C (-40°F) to
59°C (138°F) when using the IS AC-DC PS 240W power supply
with the ISW-4W-4WS-4X and ISW-24W-4X switch models.
Interfaces
Each Industrial Switch Series switch includes an RJ-45 serial console
port, dual DC power inputs for redundancy and reverse power
protection, fanless cooling, and PoE ports that are 802.3af, 802.3at and
802.bt compliant with support for up to 90W.
The following table lists the specific interfaces for each switch.
Power Supply and Rail-Kit Options
Getting Help
For additional support related to Industrial Switch Series switches or this
document, contact Extreme Networks using one of the following methods:
Notice
Copyright © 2023 Extreme Networks, Inc. All Rights Reserved.
Legal Notices
Extreme Networks, Inc. reserves the right to make changes in specifications
and other information contained in this document and its website without
prior notice. The reader should in all cases consult representatives of
Extreme Networks to determine whether any such changes have been
made.
The hardware, firmware, software or any specifications described or referred
to in this document are subject to change without notice.
Trademarks
Extreme Networks and the Extreme Networks logo are trademarks or
registered trademarks of Extreme Networks, Inc. in the United States and/or
other countries.
All other names (including any product names) mentioned in this document
are the property of their respective owners and may be trademarks or
registered trademarks of their respective companies/owners.
For additional information on Extreme Networks trademarks, please see:
https://www.extremenetworks.com/company/legal/trademarks/
Warranty
Warranty information for Industrial Switch Series is located online at:
https://www.extremenetworks.com/support/policies/
ISW-12 802.3bt 4GbP 4
Combo 4 SFP+
(ISW-4W-4WS-4X)
(12-Port model): 4 10/100/1000Base-T 90W 802.3bt
ports, 4 combo ports supporting either 4 10/100/
1000Base-T 90W PoE OR 4 1000Base-X (SFP), plus 4
10GBase-X SFP+ ports dual DC power inputs, fanless
ISW-28 802.3bt 24GbP
4 SFP+ 1RU
(ISW-24W-4X)
(28-Port model): ISW Industrial Ethernet Switch 24 10/
100/1000Base-T 90W PoE 802.3bt ports, plus 4
10GBase-X SFP+ ports dual DC power inputs, fanless,
1RU
ISW 4-10/100P, 2-10/
100T, 2-SFP
(16801)
(8-Port model): 4-Port PoE+ 10/100 2-Port 10/100 w/2-
Port SFP dual DC power inputs, fanless
ISW 8-10/100P, 4-SFP
(16802) (12-Port model): 8-Port PoE+ 10/100 w/ 4-Port SFP
dual DC power inputs, fanless
ISW 4GbP, 2GbT, 2-SFP
(16803) (8-Port model): 4-Port PoE + Gigabit, 2-Port Gigabit w/
2-Port SFP dual DC power inputs, fanless
ISW 8 GbP, 4-SFP
(16804) (12-Port model): 8-Port PoE+ Gigabit w/ 4-Port SFP
dual DC power inputs, fanless
IS AC-DC PS 240W
(16807) IS AC-DC Power Supply 240W Output DIN Rail
IS AC-DC PS 480W
(16920) IS AC-DC Power Supply 480W Output DIN Rail
ISW AC-DC PS 960W DIN
Rail
(ISW-AC-DC-PS-960W)
ISW AC-DC Power Supply 960W Output DIN Rail
Product
Documentation
View hardware and software documentation for
products on the website at:
https://www.extremenetworks.com/documentation/
From this page, you can view and download hardware
installation guides, software release notes, compatibility
matrices, software license information, and other
documents.
Global Technical
Assistance Center
(GTAC)
Phone: 1-800-998-2408 (toll-free in U.S. and Canada) or
+1-408-579-2826. For the support phone number in your
country, visit:
http://www.extremenetworks.com/support/contact/
GTAC Knowledge Get on-demand and tested resolutions from the GTAC
Knowledgebase, or create a help case if you need more
guidance.
Visit: https://gtacknowledge.extremenetworks.com/
The Hub A forum for Extreme customers to connect with one
another, get questions answered, share ideas and
feedback, and get problems solved. The community is
monitored by Extreme Networks employees, but is not
intended to replace specific guidance from GTAC.
Visit: https://community.extremenetworks.com
Support Portal Manage cases, downloads, service contracts, product
licensing, and training and certifications.
Visit: http://support.extremenetworks.com/
To request an Extreme Portal account, use the Log in or
Sign Up link at the top right corner of the Extreme Portal
home page and click Create a new Extreme Portal
account.
Regulatory and Compliance Information
Federal Communications Commission (FCC) Notice
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment uses, generates, and can radiate radio frequency energy and if
not installed in accordance with the operator’s manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause interference in which case the user will be
required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Industry Canada Notice
CAN ICES-3 (A)/NMB-3(A)
This digital apparatus does not exceed the class A limits for radio noise
emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques
dépassant les limites applicables aux appareils numériques de la class A
prescrites dans le Règlement sur le brouillage radioélectrique dicté par le
Ministère des Communications du Canada.
Class A ITE Notice
WARNING: This equipment is compliant with Class A of CISPR 32. In a
residential environment this equipment may cause radio interference.
Product Safety
This product complies with the following international safety standards:
UL 62368-1
UL 60950-1
CAN/CSA C22.2 No. 62368-1-14
CAN/CSA C22.2 No. 60950-1-07
IEC 62368-1
IEC 60950-1
EN 62368-1
EN 60950-1
• 2014/35/EU
CNS 14336-1
GB 4943.1
Optical Module Compliance
Extreme Networks pluggable optical modules and direct-attach cables meet
the following regulatory requirements:
UL and/or CSA registered component for North America
Class 1 or Class 1M Laser Product
FCC 21 CFR Chapter 1, Sub-chapter J in accordance with FDA & CDRH
requirements
IEC/EN 60825-1, IEC/EN 60825-2 or later, European Standard
Korea EMC Statement
Australia (RCM)/European Union (CE)/United Kingdom (UKCA)
WARNING: This equipment is compliant with Class A of CISPR 32. In a
residential environment this equipment may cause radio interference.
Electromagnetic Compatibility (EMC)
This product complies with the following: FCC 47 CFR Part 15 Subpart B
Class A (US), ICES-003 (Canada), EN 55032 (ITE Emissions), EN 55035 (ITE
Immunity), EN 61000-3-2 (Harmonics), EN 61000-3-3 (Flicker), 2014/30/EU
(EMC Directive), Electromagnetic Compatibility Regulations 2016 (S.I. 2016/
1091), EN 300 386 (Telecom), EN 55011 (ISM), EN 61000-6-2 (Ind. Immunity),
EN 61000-6-4 (Ind. Emissions), RCM (Australia), VCCI (Japan), MSIP KCC
(Korea), BSMI (Taiwan), ANATEL (Brazil), and CCC (China).
VCCI Notice
This is a Class A product based on the standard of the Voluntary Control
Council for Interference by Information Technology Equipment (VCCI). If this
equipment is used in a domestic environment, radio disturbance may arise.
When such trouble occurs, the user may be required to take corrective
actions.
BSMI EMC Statement — Taiwan
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
Hazardous Substances- China and Taiwan BSMI RoHS
Guidance concerning the China and Taiwan BSMI RoHS (Restriction of
Hazardous Substances) directive for this Extreme Networks® product can be
found on the following web page:
https://www.extremenetworks.com/support/documentation/restriction-
hazardous-substances/
The page contains tables detailing the presence of 10 substances defined by
the RoHS directive.
Hazardous Substances - EU
This product complies with the requirements of Directive 2011/65/EU of the
European Parliament and of the Council of 8 June 2011 on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment.
European Waste Electrical and Electronic Equipment (WEEE)
Notice
In accordance with Directive 2012/19/EU of the European Parliament on
waste electrical and electronic equipment (WEEE):
1The symbol above indicates that separate collection of electrical and
electronic equipment is required.
2When this product has reached the end of its serviceable life, it cannot be
disposed of as unsorted municipal waste. It must be collected and treated
separately.
3It has been determined by the European Parliament that there are
potential negative effects on the environment and human health as a
result of the presence of hazardous substances in electrical and electronic
equipment.
4It is the users’ responsibility to utilize the available collection system to
ensure WEEE is properly treated.
For information about the available collection system, please contact
Extreme Customer Support at +353 61 705500 (Ireland).
Extreme Networks
Industrial Switch Series
Quick Reference
ISW-4W-4WS-4X
ISW-24W-4X
16801
16802
16803
16804
P/N 9037597-00 Rev. AE
  • Page 1 1
  • Page 2 2

Extreme Networks Industrial Switches Guide de référence

Taper
Guide de référence