Royal Sovereign ARP-914 Mode d'emploi

Catégorie
Climatiseurs mobiles
Taper
Mode d'emploi

Ce manuel convient également à

Owner’s Manual
Portable Air Conditioner
Royal Sovereign International,Inc.
Please read and retain these instructions.
To register your product, please go to www.royalsovereign.com
ARP-912
ARP-914
Thank you for purchasing the Royal Sovereign Portable Air Conditioner,
ARP-912 / ARP-914. This manual will provide you with safetyinformation,
instructions for optimal use, and proper care and maintenance for your
product. Please read this manual carefully before operating.
CONTENTS
2
SAFETY INSTRUCTIONS ................................................................... 3-4
PRODUCT VIEW .............................................................................. 5
INSTALLATION ................................................................................ 6-7
PRODUCT OPERATION ..................................................................... 8-11
MAINTENANCE OF THE MACHINE ....................................................... 12-13
TROUBLESHOOTING ........................................................................ 14
SPECIFICATIONS ............................................................................. 15
WARRANTY .................................................................................... 16
3
When using this appliance follow these safety precautions to reduce risk of fire, electric shock, or injury.
Read & Fully Understand This Owner’s Manual Before Using This Machine.
SAFETY INSTRUCTIONS
WARNING
Electrical Safety
1. For your safety, this appliance should be properly grounded on a level surface indoors.
2. The appliance should be placed near an electrical outlet so that the outlet is easily accessible.
3. Make sure the voltage meets the appliance’s electricity requirements (115-120V/60Hz).
4. Do not connect this machine to an outlet having the electrical ratings below or above this
machine.
5. In case of any abnormality, be sure to turn off the machine, disconnect the plug, and contact
Royal Sovereign Customer Service.
6. Do not operate if the electrical plug or power cord is damaged. If damaged, call Royal Sovereign
Customer Service for repair/replacement.
7. Do not under any circumstances alter the electric plug.
8. Do not place heavy items on the plug or cord.
9. Do not plug this cord into a loose electrical outlet.
10. Only plug the appliance into a properly installed, grounded 3 prong outlet.
11. If the electrical outlet you intend to use is not adequately grounded or protected by a time delay
fuse or circuit breaker, you should have a qualified electrician install the proper outlet.
12. Do not share the electrical socket with other appliances.
13. Do not use an adapter plug or extension cord with this appliance.
14. Never attempt to turn off this machine by disconnecting the plug.
15. When plugging or unplugging, keep your hands dry.
16. Always grasp the plug when plugging or unplugging the appliance. Never unplug by pulling on
the cord.
17. Do not pull on the power cord while moving the unit.
18. This unit uses a plug with a built-in fuse. Conduct a Power Plug Check (see Operation page 8)
before use to confirm normal operation.
19. Turn the unit off and unplug when; cleaning the air conditioner, removing the filters, not using
the air conditioner for an extended time period.
When using this appliance follow these safety precautions to reduce risk of fire, electric shock, or injury.
Read & Fully Understand This Owner’s Manual Before Using This Machine.
SAFETY INSTRUCTIONS
WARNING
Operational Safety
1. Install the air conditioner according to the installation instructions supplied (Installation pages 6-7).
2. Do not block air outlets or intake with obstacles.
3. Do not insert any objects into the air conditioner.
4. Do not place heavy items or sit on the unit.
5. Do not place flammable or chemical substances near the unit.
6. Do not place this machine near heating appliances.
7. Do not splash or pour water on the housing or control panel.
8. To prevent the water from freezing, do not use this machine and the drain hose at a temperature
below 41°F (5°C).
9. Make sure the rubber drain plug is securely plugged into the drain port on the back of the unit at
the bottom to prevent water leaks.
10. Drain the unit before moving the air conditioner or storing the unit.
11. Do not operate the unit with the back cover removed.
12. Do not use this machine outside. Exposure to direct sunlight or rain may result in overheating,
electric shock and fire.
13. Do not modify any part of this product.
14. Do not operate this appliance for any other purpose other than its intended use.
15. This appliance is not designed for use by young children. Young children should be supervised to
ensure that they do not play with or climb on the unit.
4
1. Display panel
2. Air outlet
3. Caster wheels
4. Air filters
5. Exhaust duct (with connectors attached)
6. Cord management hook
7. Drainage port
5
PRODUCT VIEW
4
INSTALLATION
Accessories Included
1. Window seal plate
2. Exhaust duct connectors (2)
3. Exhaust duct
4. Remote control
5. Drainage hose
6. Instruction manual
NOTE: To prevent damage after moving, unpack your new portable air conditioner and let the
machine stand upright for a minimum of 2 hours before operating.
Part 1: Placement
Place the air conditioner on a flat surface and near a power supply outlet at least 8 in. (20 cm.)
away from any wall or object that could block the airflow (See below).
Socket wiring should be in accordance with the local electric safety requirements.
6
INSTALLATION
Part 2: Exhaust Hose Installation
The two exhaust duct connectors tighten on the ends of the exhaust duct (See Fig. 1).
Slide the square side of the exhaust duct connector into the opening at back of the air
conditioner (See Fig. 2 and Fig. 3).
The exhaust hose can extend up to approximately 59 in. (150 cm.).
Part 3: Window Seal Plate Installation
The window seal plate can be installed horizontally or vertically. The window seal plate can fit in
windows with a minimum width of 23.5 in (60 cm.) and a maximum width of 59 in. (150 cm.).
Open the window and place the window seal plate on the inside edge of the window.
Adjust the window seal plate to the width of the window. Once secure, close the window.
Connect the oval side of the exhaust duct connector to the window seal plate.
7
PRODUCT OPERATION
BEFORE PLUGGING IN THE UNIT TO A POWER SOURCE:
1. Let the appliance stand upright for a minimum of 2 hours. This will reduce the chance of
malfunction in the cooling system.
2. Check to make sure the rubber drain plug is securely plugged into the drainage port on the
back of the unit at the bottom to prevent water leaks.
3. Check to make sure the exhaust hose has been installed properly (See Installation page 7).
4. Check to make sure that the air conditioner has been properly vented out the window (See
Installation page 7).
Conduct a Power Plug Check:
1. Press the RESET button on the power cord.
2. Plug the cord into an electrical outlet.
3. Press the TEST button on the power cord. The RESET button should pop up.
4. Press the RESET button for use.
5. Do not use the air conditioner if the test fails. The green light on the power cord will
turn on if the plug is working properly.
Note: IF YOU TURN THE AIR CONDITIONER OFF AND IMMEDIATELY RESTART IT, ALLOW
3 MINUTES FOR THE COMPRESSOR TO RESTART COOLING. IN THE EVENT OF A POWER
FAILURE, WAIT 3 MINUTES BEFORE RESTARTING THE UNIT.
ATTENTION: THE UNIT SOLD IN THE UNITED STATES IS SET TO FAHRENEHIT. THE UNIT
SOLD IN CANADA IS SET TO CELSIUS.
8
Remote Control
All functions can be accessed from the remote control. A CR2025 battery is required for
operation. Battery is included.
Child Lock Function:
This button is on the remote control only. When pressed, this function locks the air conditioner
into the mode it is currently in. When in lock mode you cannot change modes from the display
or remote control until it is unlocked. Unlock by pressing the lock button again.
Touchscreen Control Panel:
Icon Description
Press this icon to turn the machine on and off.
Press this icon to switch between operating modes: fan, auto, and cool.
Press this icon to lower the set temperature or 24-hour timer.
Press this icon to raise the set temperature or 24-hour timer. Long press this key for 5
seconds to show the current room temperature.
Press this icon to set the wind speed of the machine. First press sets high speed,
second press sets low speed.
Press this icon to operate the timer. When the machine is on, use the timer to set
time-off. When the machine is off, use the timer to set the time-on.
Press this icon to turn on the dehumidification mode.
Press this icon (swing) to turn on vertical oscillating air vent.
PRODUCT OPERATION
9
PRODUCT OPERATION
Boot State:
When you select a mode, the machine will enter boot state. The front display, as well as the
indicator light of the mode selected will blink for a few seconds to allow the machine to process
the selection. Once the machine has processed the change, the indicator light will turn solid and
the new mode will begin.
Fan Operation:
In the boot state, press the mode icon to switch to fan mode. The front display, as well as the
indicator light will blink for a few seconds when selected and turn solid when confirmed.
In fan mode, the upper blower works and the compressor does not work.
Press the wind speed icon to switch between high and low wind speeds.
Auto Mode:
In the boot state, press the mode icon to switch to automatic mode. The front display, as well
as the indicator light will blink for a few seconds when selected and turn solid when confirmed.
When the machine is powered on for the first time or if the machine has been off for more than
30 minutes, the machine enters automatic mode by default.
When switching to automatic mode from other modes or from powering on the air conditioner
(first time or when off for over 30 minutes), the machine will automatically set to the following:
If room temperature is > 75°F (24°C) auto set to cooling mode
If room temperature is > 72°F (22°C) and < 75°F (24°C) auto set to fan mode
If room temperature is < 72°F (22°C) auto set to single cold type ventilation
Once in automatic mode, the room temperature will change, while the set mode will remain the
same. The set mode will not change until automatic mode is complete.
Cooling Operation:
In the boot state, press the mode icon to switch to cooling mode. The front display, as well as
the indicator light will blink for a few seconds when selected and turn solid when confirmed.
Press the increase or decrease icons to set the desired temperature. The temperature range is
from 59-88°F (15-31°C). The front and top digital displays will show the current set
temperature.
Press the wind speed icon to switch between high and low wind speeds.
For optimal operation, shorten the length of the air duct and keep from direct sunlight.
10
PRODUCT OPERATION
Oscillating Air Vent:
In the boot state, press the swing icon. The front display, as well as the indicator light will blink
for a few seconds when selected and turn solid when confirmed.
In this mode, the air vent louvers will automatically swing up and down.
Press the swing icon again. The indicator light will turn off when selected and the louvers will
stop swinging.
Dehumidify Mode:
In the boot state, press the dehumidification icon. The front display, as well as the indicator light
will blink for a few seconds when selected and turn solid when confirmed.
In the dehumidify mode, the fan runs at low speed and the temperature is not adjustable.
Do not use dehumidify mode when the temperature is lower than 59°F (15°C).
Timer
When the air conditioner is on, press the timer icon and select a desired off (shutdown) time
through the increase and decrease icons (+ / -). The off timer can be set for any time from 0 to
24 hours. Press the timer icon again to show the preset shutdown time on the control panel and
front display.
When the air conditioner is off, press the timer icon and select a desired on (startup) time
through the increase and decrease icons (+ / -). The on timer can be set for any time from 0 to
24 hours. The control panel and front display will show the time remaining until startup.
Once the desired time is selected, wait 3 seconds and the air conditioner will automatically
accept the setting.
11
MACHINE MAINTENANCE
Drainage
The internal water tank in the air conditioner has a water level safety switch. When the water level
reaches or exceeds an anticipated height, the buzzer alarm will ring 6 consecutive times, each
time interval of 1 second. The machine will then enter E4 water full protection mode and be shown
on the display. In E4 mode the machine will stop the refrigeration and the compressor. In order for
the the machine to resume operation it must be drained.
To drain manually:
1. Turn off the power to the unit and unplug.
2. Place a water tray under the drainage port at the bottom of the unit to collect water.
3. Remove the rubber drainage plug.
4. Replace the plug, when drainage water stops flowing.
For continuous drainage into a floor drain:
1. Turn off the power to the unit and unplug.
2. Remove the rubber drainage plug from the drainage port at the bottom of the unit.
3. Attach the drainage hose to the drainage port. Drainage hose is approximately 40in.(101cm.).
4. Place other end of drainage hose into a floor drain.
5. Replace the rubber drainage plug after operation to prevent leaks.
Cleaning the unit
1. Turn off the power to the unit and unplug.
2. Wipe down unit with a soft, dry, or damp cloth. A mild detergent can be used.
3. Never use a volatile substance such a gasoline or abrasive cleaners.
4. Do not splash water onto the unit.
WARNING: Before maintenance, turn the power switch off and disconnect the
power cord from the wall.
12
If the unit will not be used for a long time:
Drain the air conditioner manually using the drainage port (See Drainage page 12).
Remove the battery from the remote control before storage.
Clean the air filters.
Cover the unit with plastic or return it to the original carton.
Cleaning the air filters
The filters should be cleaned about every 2 weeks to maintain proper airflow.
Grasp the formed handle of the filter and pull it up, removing it from the evaporator.
Use a brush attachment with a vacuum cleaner to clean the air filters.
NOTE: Failure to keep the air filters clean will result in poor circulation. DO NOT operate the
machine without the filters.
MACHINE MAINTENANCE
WARNING: Before maintenance, turn the power switch off and disconnect the
power cord from the wall.
13
TROUBLESHOOTING
Symptom Solutions
The machine is not running
or only running on the fan
mode
Reset the power plug. Wait 3 minutes and try to run the unit again.
Securely confirm that the unit is plugged in.
Make sure the appliance voltage meets the electricity requirements.
Check to see if the water indicator light is on. If full, drain the water
tank (See Drainage page 12).
Check to see if the 24-hour timer is set to off.
Not cool enough
Make sure all windows and doors in the room are closed.
Connect the exhaust air hose tightly and make sure that it can
function properly. Keep it as short and free of curves as possible to
avoid bottlenecks.
Make sure all air inlets and outlets are not blocked. If they are, clear
the obstruction.
Remove all heat sources from inside the room.
Decrease the set temperature.
The air filter may be blocked by dust, so clean the air filter.
Machine is noisy or
vibrating during operation
Place the unit on a flat, level surface.
Make sure that the unit is not touching any other objects.
Machine often starts or
stops
Make sure that you are using the correct supply voltage from a
suitable power source.
Correct the placement of the exhaust hose
E2 Code Room temperature sensor is abnormal. Contact for repair.
E3 Code Indoor and outdoor sensor is abnormal. Contact for repair.
E4 Code Full of water. Empty tank.
E5 Code Outdoor coil sensor is abnormal. Contact for repair.
In case of problems, first turn off the air conditioner and disconnect from the source of electricity.
NOTE: For all replacements and repairs that need to be made, contact Royal Sovereign Customer Service at +1) 800-397-1025
14
MODEL ARP-912 ARP-914
Cooling Capacity
12,000 BTU ASHRAE
6,000 BTU DOE
14,000 BTU ASHRAE
7,000 BTU DOE
Room Size (Sq. ft.) Up to 450 Up to 500
Voltage / Frequency 115-120V / 60 Hz 115-120V / 60 Hz
Standard Cooling Input Power
1420W ASHRAE
1310W DOE
1880W ASHRAE
1576W DOE
Rated Cooling Current 11.5 A 6.6 A
Operating Sound Level ≤ 56 dB ≤ 56 dB
Dehumidifier Capacity 45.6 Pints (21.6 L) per Day 60.9 Pints (28.8 L) per Day
Air Flow Volume 340 m3h 340 m3h
Fan Speeds 2 2
Fan Speed Level
Low: 950 rpm
High: 1200 rpm
Low: 1000 rpm
High: 1250 rpm
Refrigerant R410A R410A
Temperature Setting
59-88 °F (15-31 °C) 59-88 °F (15-31 °C)
Certification cETLus cETLus
Unit Dimensions (W x D x H)
15.94”W x 12.4”D x 25.98”H
405 mm x 315 mm x 660 mm
15.94”W x 12.4”D x 25.98”H
405 mm x 315 mm x 660 mm
Unit Weight 55.12 lbs. / 25 kgs. 55.12 lbs. / 25 kgs.
15
SPECIFICATIONS
Royal Sovereign International, Inc. warranties this product to be free from defects in material and
workmanship to the original purchaser only as outlined below.
Parts: Replacement of defective parts for 1 year from the date of customer
purchase.
Compressor: 3-year warranty from the date of customer purchase. Royal
Sovereign will supply a replacement compressor (parts only), free of charge.
Labor: 1 year from the date of end user purchase.
This warranty only covers products that are properly installed, properly maintained, and properly operated in
accordance with the instructions provided. This limited warranty does not cover any failures or operating
difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper
installation, or improper maintenance and service by you or any thirdparty.
Returned product will not be accepted without a Return Authorization number. To request a Return
Authorization number, please visit us at www.royalsovereign.com. All transportation costs for the return of
damaged product or parts will be the responsibility of the purchaser. Return defective product, in original
packaging, to the addressbelow.
Royal Sovereign International, Inc. requires reasonable proof of your date of purchase from an authorized
retailer or distributor. Therefore, you should keep your receipt, invoice, or canceled check from the original
purchase. The limited warranty shall be limited to the repair or replacement of parts which prove defective
under normal use and service within the warranty period.
Royal Sovereign International, Inc. (and its affiliated companies) SHALL HAVE NO LIABILITY
WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE,
INCIDENTAL,OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of
incidental or consequential damages so the above exclusion and limitations may not apply toyou.
For product support and warranty questions, please visit us at
www.royalsovereign.com/customer-support.html
ROYAL SOVEREIGN INTERNATIONAL, INC.
2 Volvo Dr., Rockleigh, NJ 07647 USA
TEL: +1) 800-397-1025
Email:info@royalsovereign.com
ONE YEAR LIMITED WARRANTY
RS INTERNATIONAL CANADA INC.
191 Superior Blvd, Mississauga Ontario L5T 2L6 CANADA
TEL : +1) 905-461-1095 TF # : +1) 866-961-6673
FAX : +1) 905-461-1096
www.royalsovereign.ca
16
Guide d’utilisation
Climatiseur portable
Royal Sovereign International,Inc.
Veuillez lire et conserver ces instructions.
Pour plus d'informations, veuillez consulter le site
www.royalsovereign.com
ARP-912
ARP-914
Merci d'avoir acheté le climatiseur portable, ARP 912 / ARP 914 de Royal
Sovereign. Ce guide d'utilisation vous fournira des informations sur la
sécurité, des instructions pour une utilisation optimale, ainsi que pour un
entretien et une maintenance appropriés de votre produit. Veuillez lire
attentivement ce guide avant d'utiliser le produit.
CONTENU
INSTRUCTIONS DE SÉCURITÉ.……….........................................................................
SURVOL DU PRODUIT.……………………......................................................................
INSTALLATION………………………………………………………………………………...
FONCTIONNEMENT DU PRODUIT…….………………..………….................................
ENTRETIEN DE LAPPAREIL.
DÉPANNAGE...................................................................................................................
SPÉCIFICATIONS............................................................................................................
GARANTIE……….............................................................................................................
18
19-20
21
22-23
24-27
28-29
30
31
32
19
Lorsque vous utilisez cet appareil, suivez ces précautions de sécurité pour réduire les risques
d'incendie, d'électrocution ou de blessure.
Lisez et comprenez bien ce guide d'utilisation avant d'utiliser cet appareil.
INSTRUCTIONS DE SÉCURITÉ
AVERTISSEMENT
Sécurité électrique
1. Pour votre sécurité, cet appareil doit être correctement mis à la terre sur une surface plane à l'intérieur.
2. L'appareil doit être placé près d'une prise électrique de manière à ce que celle-ci soit facilement
accessible.
3. Assurez-vous que la tension est conforme aux exigences électriques de l'appareil (115-120V/60Hz).
4. Ne branchez pas cet appareil sur une prise de courant dont la puissance électrique est inférieure ou
supérieure à celle de cet appareil.
5. En cas d'anomalie, assurez-vous d'éteindre l'appareil, de débrancher la fiche et de contacter Service
clientèle de Royal Sovereign.
6. Ne pas utiliser si la prise électrique ou le cordon d'alimentation est endommagé. S'il est endommagé,
appelez le Royal Sovereign Service clientèle pour la réparation/remplacement.
7. Ne modifiez en aucun cas la prise électrique.
8. Ne placez pas d'objets lourds sur la prise ou le cordon.
9. Ne branchez pas ce cordon dans une prise électrique mal fixée.
10. Ne branchez l'appareil que sur une prise à 3 broches correctement installée et mise à la terre.
11. Si la prise électrique que vous comptez utiliser n'est pas correctement mise à la terre ou protégée par
une temporisation. Si vous avez besoin d'un fusible ou d'un disjoncteur, vous devez faire installer la
prise de courant appropriée par un électricien qualifié.
12. Ne partagez pas la prise électrique avec d'autres appareils.
13. N'utilisez pas d'adaptateur ou de rallonge avec cet appareil.
14. N'essayez jamais d'éteindre cet appareil en débranchant la prise.
15. Lorsque vous branchez ou débranchez l'appareil, gardez vos mains au sec.
16. Saisissez toujours la fiche lorsque vous branchez ou débranchez l'appareil. Ne débranchez jamais
l'appareil en tirant sur le cordon.
17. Ne tirez pas sur le cordon d'alimentation lorsque vous déplacez l'appareil.
18. Cet appareil utilise une prise avec un fusible intégré. Effectuez une vérification de la fiche d'alimentation
(voir Fonctionnement page 24) avant l'utilisation pour confirmer le fonctionnement normal.
19. Éteignez et débranchez l'appareil lorsque vous nettoyez le climatiseur, retirez les filtres ou n'utilisez pas
les le climatiseur pendant une période prolongée.
INSTRUCTIONS DE SÉCURITÉ
Fonctionnement sécuritaire
1. Installez le climatiseur conformément aux instructions d'installation fournies (Installation, pages 22
et 23).
2. N'obstruez pas les sorties ou les entrées d'air avec des obstacles.
3. N'insérez aucun objet dans le climatiseur.
4. Ne placez pas d'objets lourds ou ne vous asseyez pas sur l'appareil.
5. Ne placez pas de substances inflammables ou chimiques à proximité de l'appareil.
6. Ne placez pas l'appareil à proximité d'appareils de chauffage.
7. Ne pas éclabousser ou verser de l'eau sur le boîtier ou le panneau de commande.
8. Pour éviter que l'eau ne gèle, n'utilisez pas cette machine et le tuyau de vidange à une
température inférieure à 5°C (41°F).
9. Assurez-vous que les bouchons de vidange en caoutchouc sont bien branchés dans les orifices
de vidange à l'arrière de l'appareil pour éviter les fuites d'eau.
10. Vidangez l'appareil avant de déplacer le climatiseur ou de ranger l’appareil.
11. Ne faites pas fonctionner l'appareil lorsque le couvercle arrière est retiré.
12. N'utilisez pas l'appareil à l'extérieur.
13. Ne modifiez aucune partie de ce produit.
14. N'utilisez pas cet appareil à d'autres fins que celles pour lesquelles il a été conçu.
15. Cet appareil n'est pas conçu pour être utilisé par de jeunes enfants. Les jeunes enfants doivent
être surveillés pour s'assurer qu'ils ne jouent pas avec l'unité ou ne grimpent pas dessus.
20
Lorsque vous utilisez cet appareil, suivez ces précautions de sécurité pour réduire les risques
d'incendie, d'électrocution ou de blessure.
AVERTISSEMENT
Lisez et comprenez bien ce guide d'utilisation avant d'utiliser cet appareil.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Royal Sovereign ARP-914 Mode d'emploi

Catégorie
Climatiseurs mobiles
Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues