IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER
– TO REDUCE THE RISK OF ELECTRIC SHOCK:
Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use
under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by
exposure to water or moisture.
Always unplug the unit from the electrical outlet immediately after using and before cleaning
DO NOT reach for a unit that has fallen into water. Unplug it immediately.
DO NOT use while bathing or in the shower.
DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
DO NOT place or drop into water or other liquids.
DO NOT use water above 86° Fahrenheit.
WARNING
– TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
Close supervision is necessary when this unit is used by or near children, invalids, or disabled
persons.
Use this unit only for its intended use as described in this manual. Do not use attachments not
recommended by HoMedics; specifically any attachments not provided with this unit.
NEVER drop or insert any object into any opening.
DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.
NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has
been dropped or damaged, or dropped into water. Return the appliance to a HoMedics Service Center
for examination and repair.
Always unplug the unit when filling or moving the unit.
Ensure that your hands are dry when operating the controls or removing the plug.
Always hold the water tank firmly with both hands when carrying a full tank of water.
NEVER use the humidifier in an environment where explosive gasses are present.
DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to
direct sunlight.
DO NOT carry this unit by the power cord or use the power cord as a handle.
To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.
This product is intended for household use only.
Caution: All servicing of this humidifier must be performed by authorized HoMedics service
personnel only.
3
SAVE THESE INSTRUCTIONS
CAUTION
– PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
Never cover the unit while it is operating.
Always keep the cord away from high temperature and fire.
If the cord sustains damage, you must stop using this product immediately and contact HoMedics
consumer relations (see Warranty section for consumer relations contact information).
Perform regular maintenance on the ultrasonic membrane.
Never use detergent to clean the ultrasonic membrane.
Never clean the ultrasonic membrane by scraping with a hard object.
Do not attempt to adjust or repair the unit. Servicing must be performed by professional or qualified
personnel.
Stop using this unit if there is an unusual noise or smell.
Unplug this unit when not in use for a long period of time.
Do not touch the water or any parts of the unit that are covered by water while the unit is on or
plugged in.
Never operate without water in the tank.
Only use water in the tank.
Never use any additive to the water.
Do not wash, adjust, or move this unit without first unplugging it from the electrical outlet.
Keep this unit out of reach of children. Do not allow children to use this unit without supervision.
DO NOT use outdoors. For indoor use only.
4
UNIQUE FEATURES & SPECIFICATIONS
ULTRASONIC TECHNOLOGY
This humidifier uses ultrasonic high frequency technology to convert the water into 1–5 million super
particles that are dispersed into the air evenly.
DIGITAL READOUT
Displays programmed humidity setting, timer setting, warm or cool mist selection and mist output level.
PROGRAMMABLE HUMIDISTAT
Customize the level of humidity between 35% – 60% in 5% increments.
BUILT-IN TIMER
Programmable timer, up to 12 hours.
NIGHT LIGHT / DISPLAY LIGHTS
A useful light feature is included for your convenience, with the option of independent Night Light and
Display Light ON/OFF controls.
AUTO SHUT-OFF PROTECTION
When the tanks are empty the unit will shut off automatically.
CAPACITY
2.0 gallon – 7.57 liters
DUAL WATER TANKS
Refill one tank while the other is running.
RUN TIME: 12-120 HOURS
Run time is calculated based on using cool mist and setting the mist level from the high to the low
setting. Based on the natural humidity level in your home, the temperature of water you use, and the mist
level setting you choose, you may experience longer or shorter run times.
AROMA CAPABLE
Includes 2 essential oil samples and aroma pads, or use your favorite essential oil to deliver aroma into
the air.
5
TIMER
+
HUMIDISTATMIST
WARM
LAMP
TOTAL COMFORT ULTRASONIC HUMIDIFIER WARM & COOL MIST
WATER TANKS
TANK CAPS
MIST SPOUT
DIGITAL CONTROL
PANEL
POWER PLUG
ULTRASONIC
DISC*
1
ULTRASONIC
COVER*
1
ESSENTIAL
OIL TRAY*
* These items are accessed
from the back of the unit
1
Water Tanks must be
removed to access
6
HOW TO FILL
CAUTION: Before filling unit with water, turn the power off and unplug the unit from the outlet.
NOTE: Always use two hands to carry the water tank.
TIMER
+
HUMIDISTATMIST
WARM LAMP
TIMER
+
HUMIDISTATMIST
WARM LAMP
+
1. Grasp tank handle
and lift up from
humidifier base.
3. Fill the water tanks with
clean, cool (not cold)
water. We recommend
using distilled water
if you live in a hard
water area. Never add
essential oils into the
water tank. Even a few
drops will damage the
unit. See page 9 for
aroma instructions.
5. Install the tank back
on the base of the unit.
Make sure the tank is
firmly seated.
6. Your humidifier is
ready for use.
4. Replace the tank cap by
turning clockwise until
tight.
2. Turn the tank upside
down—remove the
tank cap by turning it
counter-clockwise.
O
P
E
N
C
L
O
S
E
O
P
E
N
C
L
O
S
E
7
HOW TO FILL
CAUTION: Before filling unit with water, turn the power off and unplug the unit from the outlet.
NOTE: Always use two hands to carry the water tank.
HOW TO USE
Display shows:
Programmed Humidity Setting (pictured),
Timer Setting, Warm or Cool Mist
Selection, and Mist Output Level
Power ON/OFF Button
Timer
Night Light / Display Light
Programmable Humidistat
Mist Temperature
Mist Output Level
Programmable Humidistat Setting
POWER ON/OFF BUTTON
Plug unit in to a 120 volt AC electrical outlet. Press the POWER button to turn unit on.
MIST OUTPUT LEVEL
Mist adjusts from the lowest output 1 to the highest output 5. To increase the mist output, press the
+ Button. The corresponding Mist Level will be lit on the display. To decrease mist output, press the –
Button.
MIST TEMPERATURE SETTING
To change the mist temperature from Cool to Warm Mist, press the Mist Temperature Button. WARM
will be illuminated on the display. To change the mist temperature from Warm to Cool Mist, press the Mist
Temperature Button again. COOL will be illuminated on the display.
NOTE: Once Warm Mist is selected, it will take approximately 20 minutes to heat up before the mist
becomes warm.
8
HOW TO USE
PROGRAMMABLE HUMIDISTAT
The Programmable Humidistat can be set in 5% increments from 35% - 60% humidity.
To program the humidity level, press the Humidistat Button. Then press the + / - Button. The humidity
level will increase / decrease by 5% every time the + / - Button is pressed and will show on the display
screen. Keep pressing the + / - Button until the desired programmable humidity setting is reached. The
display will show the set humidity level for 5 seconds, then default back to display the mist output level.
NOTE: To eliminate any programmed Humidistat setting, press the Humidistat Button. Then press the +
Button until you reach “CO” (continuous on) one level above 60%.
NOTE: When the set humidity level is reached, the humidifier will cycle off until the humidity in the room
drops 5% below the set humidity level, then will cycle on until the set humidity level is reached again.
NIGHT LIGHT / DISPLAY LIGHT
Press the Night Light / Display Light Button once to turn on the night light. The light at the bottom of
the water tanks will turn on, illuminating the tanks. Press a second time to leave the night light on, but
turn off the display light. Press a third time to turn off the night light and display light so no lights are
illuminating. Press a fourth time to turn the display light on.
TIMER
Press the Timer Button. Keep pressing the Timer Button until the desired timer setting is lit on the
display. The Timer Button will cycle through the following settings 0 hours, 2 hours, 4 hours, 8 hours,
12 hours, 0 hours. To turn the Timer off, press the Timer Button until 0 hours is shown on the display.
NOTE: Always be sure the humidifier has a full tank of water prior to using the timer setting.
AUTO-OFF
When the water in the tank is almost empty, the humidifying function will power off to indicate to the user
to refill the tank.
NOTE: It is normal to have a small amount of water in the base during and after use.
AROMA CAPABLE
The aroma feature will function automatically when the mist is turned ON.
9
HOW TO USE
AROMA
Choose from 2 included oil samples, or your favorite essential oil to deliver aroma into the air.
NOTE: For use with the Included HoMedics Aroma Pads only.
NOTE: Do not leave a filled Aroma Pad in the Essential Oil Tray of the humidifier if it will be out of use for
a long period of time.
1. To open the essential oil tray on the
lower back panel of the humidifier,
press the spring loaded tray. It will
pop open, and you can remove the tray.
2. Place 1 Aroma Pad into the
matching slot in the essential
oil tray
3. Add 5-7 drops of essential oil to the
pad. Depending on your personal
preference, you may add more or
fewer drops of essential oil.
4. Place the essential oil tray back in its
compartment and push to close. The
aroma will start automatically when
the mist is turned ON.
To purchase genuine HoMedics replacement aroma pads, Model # ARMH-PAD1-10PK, go to your retailer where you
purchased your TotalComfort Ultrasonic Humidifier Warm & Cool Mist, or visit www.homedics.com.
To purchase genuine HoMedics essential oils, go to your retailer where you purchased your TotalComfort Ultrasonic
Humidifier Warm & Cool Mist, or visit www.homedics.com.
10
ABOUT WHITE DUST:
Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces
in the room near the humidifier. The mineral residue is commonly called “white dust.” The higher the
mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is
not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.
HOW AND WHY TO USE DEMINERALIZATION CARTRIDGES:
The HoMedics demineralization cartridge will help reduce the potential for white dust, a deposit of
minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30
– 40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace
the cartridge when you notice an increase in white dust build-up. If white dust still forms around the
humidifier after a new cartridge has been installed, consider using distilled water.
To purchase new demineralization cartridges, model # UHE-HDC4, go back to the retailer (where you
purchased your humidifier), or visit www.homedics.com
If you live in an area with hard water, or use a water softener, we recommend using distilled water for
better results from your humidifier. Never use water softening additives in your humidifier.
INSTALLATION INSTRUCTIONS
1. Remove demineralization cartridges from packaging and let them soak in water for 10 minutes.
2. Remove the tanks from humidifier base and turn them over.
3. Unscrew the tank caps by turning counter-clockwise.
4. Fill each tank with water as shown in the How to Fill section of the instructions included with
your humidifier.
5. Add the soaked demineralization cartridge into each tank.
6. Replace the tank caps by turning clockwise.
7. Place the tanks back on the base.
Demineralization Cartridges
11
CLEANING AND CARE
CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.
TO CLEAN THE TANKS
Remove the water tanks from the humidifier base by lifting them
from the main unit. Unscrew the tank caps and rinse inside the
tanks with clean water.
Every Day: Empty and rinse each tank and tank cap before refilling.
Every Week: To remove any scale or build up, use a 50/50 mixture of
white vinegar and lukewarm water to clean the inside of the tanks.
TO CLEAN THE ULTRASONIC MEMBRANE
Every Day: Empty, rinse and dry the ultrasonic membrane and the
reservoir before refilling.
Every Week: Remove the transducer plate cover. Pour a 50/50
mixture of white vinegar and water on the surface of the ultrasonic
membrane, then soak for five minutes. Brush clean with a
soft-bristle brush (not included) and rinse. Replace transducer
plate cover.
NEVER touch the ultrasonic membrane with your fingers as the
natural oils in skin can damage the membrane.
NOTE: Never submerge the base in water or any liquid
TO CLEAN THE AROMA TRAY
Open the aroma tray and remove the aroma pad. Aroma pads
should be changed when switching to a different essential oil scent.
If continuing to use the same scent, set the aroma pad aside for
reuse. Wipe down the inside of the aroma tray with a soft cloth.
Place the aroma pad back in the tray and close.
NOTE: Leave the aroma pad out of the aroma tray when storing.
TO CLEAN THE SURFACE
Clean the surface of the unit with a clean damp soft cloth.
Before Storing: Clean the Tanks, Reservoir, Tank Caps and the
Ultrasonic Membrane with a 50/50 mixture of white vinegar and
water. Be sure to rinse and let all parts dry completely before
storing. Clean the aroma tray with a soft cloth.
After Storing: Rinse the Tanks, Reservoir, Ultrasonic Membrane and
Aroma Tray with water. Dry completely before filling. Only fill the
tank just before operating.
COOL
% RH
TIMER
+
HUMIDISTATMIST
WARM LAMP
TIMER
+
HUMIDISTATMIST
WARM LAMP
+
NOT FOR USE WITH ESSENTIAL OILS
12
PROBLEM POSSIBLE CAUSE SOLUTION
No Power/No Mist from Spout Unit is not plugged in
No power at unit
Low water level
The humidistat setting is
lower than the current room
humidity
Plug unit in
Press the Power Button to
turn the unit on
Check circuits and fuses or
try a different outlet
Refill the tank with water
Reset the humidistat to a
higher humidity level, or
change the mist output to
Continuous ON
Peculiar Odor Unit is new
If unit is in use, the odor
may be a dirty tank or old
tank water
Open the water tank cap and
keep it in a shady, cool place
for 12 hours
Empty the old water,
clean the tank and fill
with clean water
Excessive Noise Unit is not level
Low water level
Place unit on a flat,
even surface
Check the water level. Refill
the tank if the water is low
White Dust Accumulation Hard water used
Demineralization Cartridge
needs replacement
Use distilled water and a
Demineralization Cartridge
Replace Demineralization
Cartridge
TROUBLESHOOTING
13
FCC DISCLAIMER
This product has been tested and complies with the requirements for Federal Communication
Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other
devices. If this product is found to interfere with another device, separate the other device and this
product. Conduct only the user maintenance found in this instruction manual. Other maintenance and
servicing may cause harmful interference and can void the required FCC compliance.
Caution: All servicing of this humidifier must be performed by authorized HoMedics service
personnel only.
HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of one
year from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects
in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend
to Retailers.
To obtain warranty service on your HoMedics product, contact a consumer relations representative for assistance. Please
make sure to have the model number of the product available.
HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the
product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This
warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory;
alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power
supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer’s
recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use
during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever
that are beyond the control of HoMedics
This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A
product that requires modifications or adoption to enable it to operate in any other country than the country for which it was
designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered
under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER
WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER
OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL
HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY
REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE
WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE
MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR
OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including
but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers.
Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are
repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.
This warranty provides you with specific legal rights. You may have additional rights which may vary from state to state and
country to country. Because of individual state and country regulations, some of the above limitations and exclusions may
not apply to you.
For more information regarding our product line in the USA, please visit: www.homedics.com. For Canada, please visit:
www.homedics.ca.
FOR SERVICE IN THE USA:
Monday-Friday 8:30am-7:00pm EST
1.800.466.3342
FOR SERVICE IN CANADA:
Monday-Friday 8:30am-5:00pm EST
1.888.225.7378
ONE YEAR LIMITED WARRANTY
©2017 HoMedics, LLC. All Rights Reserved. HoMedics is a registered trademarks of HoMedics, LLC.
Total Comfort and Leaders in Home Environment are trademarks of HoMedics, LLC.
IB-UHEWM350
MANUEL D'UTILISATION ET INFORMATIONS SUR LA GARANTIE
UHE-WM350
UNE ANNÉE DE GARANTIE LIMITÉE
www.homedics.com/register
Votre contribution précieuse
concernant ce produit nous aidera à
créer les produits que vous voudrez
à l'avenir.
VEUILLEZ PRENDRE
MAINTENANT UN MOMENT
ENREGISTRER VOTRE
PRODUIT À :
16
IMPORTANTES CONSIGNES DE SÉCURITÉ
LORSQUE VOUS UTILISEZ DES PRODUITS ÉLECTRIQUES, DES PRÉCAUTIONS DE BASE DEVRONT TOUJOURS
ÊTRE RESPECTÉES, Y COMPRIS LES SUIVANTES :
LISEZ TOUTES LES INSTRUCTIONS AVANT UTILISATION
DANGER
– POUR DIMINUER LE RISQUE D’ÉLECTROCUTION :
Posez toujours l’humidificateur sur une surface plate et ferme. Il est recommandé de poser
l’humidificateur sur un paillasson ou une serviette étanche. Ne le posez jamais sur un tapis ou une
moquette, ou sur un sol fini qui pourrait être endommagé au contact avec de l’eau ou de l’humidité.
Débranchez toujours l’appareil de la prise électrique immédiatement après usage ou avant entretien
NE TOUCHEZ PAS à un appareil qui est tombé dans l’eau. Débranchez-le immédiatement.
NE L’UTILISEZ PAS lorsque vous prenez un bain ou une douche.
NE POSEZ PAS ou NE RANGEZ PAS l’appareil à un endroit où il pourrait tomber ou être accroché et
tomber dans une baignoire ou un évier.
NE LE POSEZ PAS ou NE LE PLONGEZ PAS dans de l’eau ou d’autres liquides.
N’UTILISEZ PAS une eau à une température de plus de 86° Fahrenheit.
AVERTISSEMENT
– POUR DIMINUER LE RISQUE DE BRÛLURE, D’INCENDIE, D'ÉLECTROCUTION,
OU DE BLESSURES :
Une surveillance étroite est nécessaire lorsque cet appareil est utilisé par ou à proximité d’enfants,
d’invalides ou de personnes handicapées.
Utilisez cet appareil uniquement aux fins décrites dans ce manuel. N'utilisez pas d'accessoires qui
ne sont pas recommandés par HoMedics; de manière spécifique, tout accessoire non fourni avec
l’appareil.
N’insérez JAMAIS un objet dans n’importe laquelle des ouvertures.
NE L’UTILISEZ PAS à un endroit où des produits en aérosol (vaporisateurs) sont utilisés ou en cas
d’administration d’oxygène.
N’utilisez JAMAIS l’appareil si son cordon ou sa fiche sont endommagés, s’il ne fonctionne pas bien,
s’il est tombé ou a été endommagé, ou s’il est tombé dans l’eau. Rapportez l’appareil au centre de
services HoMedics pour examen et réparation.
Débranchez toujours l’appareil lors de son remplissage ou lorsque vous le déplacez.
Veillez à ce que vos mains soient sèches lorsque vous utilisez les commandes ou lorsque vous
débranchez la fiche.
Déplacez le réservoir d’eau en veillant toujours à le tenir fermement des deux mains lorsqu’il est
rempli.
N’utilisez JAMAIS l’humidificateur dans les endroits où des gaz explosifs sont présents.
NE mettez PAS l’humidificateur à côté d'une source de chaleur telle qu'un four et ne l’exposez pas
directement aux rayons du soleil.
17
NE PORTEZ PAS cet appareil par le cordon d’alimentation ou en utilisant le cordon d’alimentation
comme poignée.
Pour l’éteindre, réglez toutes les commandes sur la position «off», puis retirez la fiche de la prise.
Ce produit est destiné à un usage domestique uniquement.
Attention : L’entretien de cet humidificateur doit être effectué uniquement par le personnel de
services autorisé de HoMedics.
CONSERVEZ CES INSTRUCTIONS
ATTENTION
– VEUILLEZ LIRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS AVANT DE L’UTILISER.
Ne couvrez jamais l’appareil lorsqu’il est en marche.
Placez toujours le cordon à l’écart des températures élevées et du feu.
Si le cordon a été endommagé, vous devez immédiatement arrêter d’utiliser ce produit et contacter le
centre de relations avec les consommateurs de HoMedics (voir la partie Garantie pour les coordonnées
du centre de relations avec les consommateurs).
Effectuez l'entretien régulier de la membrane d’ultrasons.
Ne nettoyez jamais la membrane d’ultrasons avec des détergents.
Ne nettoyez jamais la membrane d’ultrasons en grattant avec un objet dur.
N’essayez pas de moduler ou de réparer l’appareil. L’entretien doit être effectué uniquement par le
personnel de services autorisé ou des professionnels.
Arrêtez d’utiliser cet appareil en cas de bruit ou odeur inhabituels.
Débranchez cet appareil en cas d’absence prolongée de son utilisation.
Ne touchez pas l’eau ou toute partie de l’appareil recouverte d’eau lorsque celui-ci est en marche ou
branché.
Ne le faites jamais fonctionner en cas d’absence d’eau dans le bac.
Utilisez uniquement de l’eau dans le bac.
N’utilisez aucun additif dans l’eau.
Veillez à ne pas nettoyer, moduler, ou déplacer cet appareil sans l’avoir préalablement débranché de la
prise électrique.
Gardez l'appareil hors de portée des enfants. Ne laissez pas les enfants utiliser cet appareil sans
surveillance.
NE L’UTILISEZ PAS à l’extérieur. Pour usage intérieur uniquement.
18
CARACTÉRISTIQUES ET SPÉCIFICATIONS UNIQUES
TECHNOLOGIE DES ULTRASONS
Cette humidificateur s’appuie sur la technologie des ultrasons à haute fréquence pour tranformer l’eau en
1 à 5 millions de particules fines qui sont dispersées uniformément dans l’air.
AFFICHAGE DIGITAL
Affiche les réglages programmés en matière d’humidité et de minuterie, le choix de vapeur froide ou
chaude et le niveau de débit de vapeur.
HYGROSTAT RÉGLABLE
Réglez le niveau d’humidité par paliers de 5 %, entre 35 % et 60 %.
MINUTERIE INTÉGRÉE
Minuterie réglable, jusqu’à 12 heures.
MODE NUIT/LUMIÈRE D’AFFICHAGE
Pour votre confort, la caractéristique de lumière est offerte avec l’option de commandes ON/OFF pour la
lumière en mode nuit et de lumière d’affichage.
SÉCURITÉ AVEC DISPOSITIF D’ARRÊT AUTOMATIQUE
Lorsque les bacs sont vides, l’appareil s’éteindra automatiquement.
CAPACITÉ
2,0 gallons – 7,57 litres
SYSTÈME À DEUX BACS D’EAU
Remplissez un bac tandis que l’autre bac est utilisé.
DURÉE DE FONCTIONNEMENT : 12 -120 HEURES
La durée de fonctionnement est calculée sur la base de l’utilisation ou non de la vapeur et du réglage
élevé ou bas du niveau de débit de la vapeur. Suivant le niveau d’humidité de votre maison, la
température de l’eau que vous utilisez, et le niveau de débit de vapeur que vous choisissez, les durées de
fonctionnement s’en verront affectées.
FONCTION AROMA
Comprend 2 échantillons d’huiles essentielles et de diffuseurs aroma; vous pouvez également utiliser
votre huile essentielle préférée pour diffuser des senteurs dans les airs.
19
HUMIDIFICATEUR À ULTRASONS TOTAL COMFORT AVEC
VAPEUR CHAUDE ET FROIDE
TIMER
+
HUMIDISTATMIST
WARM
LAMP
BACS D’EAU
BOUCHONS DE BAC
BEC VERSEUR DE VAPEUR
COMMANDE DIGITALE
PANNEAU
PRISE DE COURANT
ULTRASONIQUE
DISQUE
ULTRASONIQUE*
1
ULTRASONIQUE
REVÊTEMENT*
1
ESSENTIELLE
BAC À HUILE*
* Ces éléments sont accessibles
au dos de l’appareil
1
Les bacs d’eau doivent être
enlevés pour y accéder
20
INSTRUCTION DE REMPLISSAGE
PRUDENCE : Avant de remplir l’appareil avec de l’eau, éteignez et débranchez l’appareil de la prise murale.
REMARQUE : Utilisez toujours vos deux mains pour déplacer le bac.
TIMER
+
HUMIDISTATMIST
WARM LAMP
TIMER
+
HUMIDISTATMIST
WARM LAMP
+
1. Tenez la poignée du
bac et soulevez-le
pour le détacher
de la base de
l’humidificateur.
3. Remplissez les bacs avec de
l’eau claire et fraîche (non
froide). Nous conseillons
l’utilisation de l’eau distillée si
vous vivez dans un endroit où
l’eau est dure. N’ajoutez jamais
d’huiles essentielles à l’eau du
bac. Quelques gouttes suffisent
à endommager l’appareil. Voir
page 23 pour les instructions
en matière d’aroma.
5. Remettez le bac sur
la base de l’appareil.
Veillez à ce que le bac
soit fermement fixé.
6. Votre humidificateur
est prêt à l’emploi.
4. Vissez à fond le bouchon
du bac en tournant
dans le sens des
aiguilles d’une montre.
2. Retournez le bac d’eau
– enlevez le bouchon
du bac en tournant
dans le sens inverse
des aiguilles d’une
montre.
O
P
E
N
C
L
O
S
E
O
P
E
N
C
L
O
S
E
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

HoMedics TOTAL COMFORT UHE-WM350 Le manuel du propriétaire

Catégorie
Humidificateurs
Taper
Le manuel du propriétaire
Ce manuel convient également à