Make Power Connections
CAUTIONS/AVERTISSEMENT:
• Observe the proper polarity when making connections to IN 1 and IN 2.
• Do not turn the power on until the DIN-2LEDPWM8 is fully connected.
• Use a certified Class 2 power supply (12–24 VDC) when making connections to
the + and - terminals for the IN 1 and IN 2 connection. The power supply provides power to
the LED channels.
• Respectez la polarité lorsque vous connectez IN 1 et IN 2.
• N’allumez pas l’appareil DIN-2LEDPWM8 tant qu’il n’est pas entièrement raccordé.
• Utilisez une source d’alimentation certifiée de Classe 2 (12-24 VDC) lors des connexions
aux bornes + et - pour le raccordement de IN 1 et IN 2. La source d’alimentation fournit du
courant aux canaux LED.
Connect power supplies to IN 1 and IN 2. The IN 1 and IN 2 terminals accept 18–12 AWG wires.
Power supplied to IN 1 provides power to OUTPUT-1 (100 W maximum) and power supplied
to IN 2 provides power to OUTPUT-2 (100 W maximum).
NOTE: One power supply can provide power to IN 1 and IN 2. Total combined power output for
OUTPUT 1 and OUTPUT 2 will be 100W.
12-24 VDC power input.
Use 18-12 AWG wires.
Supplies power to OUTPUT-1.
100W max input.
Ensure proper polarity.
12-24 VDC power input.
Use 18-12 AWG wires.
Supplies power to OUTPUT-2.
100W max input.
Ensure proper polarity.
Make OVERRIDE Connections (Optional)
The OVERRIDE (OVR G) port provides a connection to a contact closure and a pass-through
connection to additional devices. The OVERRIDE ports are wired in parallel. Make connections as
necessary.
From contact
closure
Daisy-chain to override
port on additional
Operation
Identify the Device
Press the SETUP button to acknowledge a TSID (Touch-Settable ID) message from Crestron
Toolbox ™ software.
Control the R, G, B, and W Channels
The R, G, B, and W buttons on the front of the DIN-2LEDPWM8 provide local control of the
red (R), green (G), blue (B), and white (W) channels.
Toggle the Channels
To toggle the red, green, blue, or white channel on and off, press the R (red channel),
G (green channel), B (blue channel) or W (white channel) button. The corresponding R, G, B, or W
LED lights to indicate that the channel is on.
NOTE: A command from the control system (turn on, turn off, raise or lower the LED) will
override any local settings.
Dim the Channels
To dim the red, green, blue, or white channel of the LED or LED strip, press and hold
the R (red channel), G (green channel), B (blue channel) or W (white channel) button. If the LED
or LED strip is off, the brightness raises until it reaches 100%. If the LED or LED strip is at 100%
brightness, the brightness lowers until it turns off. The corresponding R, G, B, or W LED lights to
indicate that the channel is on.
NOTES:
• If the button is released before the LED or LED strip brightness reaches 100% or off (0%),
a subsequent press and hold continues to raise or lower the LED or LED strip brightness.
• A command from the control system to change the LED or LED strip light level will override
any local settings.
Override Mode
Override mode is entered when a contact closure is engaged. When Override mode is enabled,
the R, G, B, and W channels are turned on to 100% brightness (default) and their corresponding
LEDs light. Remote control of the channels is disabled. Channels can be controlled using the
buttons on the front of the device. When Override mode is exited, the R, G, B, and W channels
return to their previous light level.
NOTE: The control system program can be configured to turn the channels to levels other than
100% brightness when the DIN-2LEDPWM8 is in Override mode.
Restart the Device
Press the RESET button to restart the DIN-2LEDWPM8. After the DIN-2LEDPWM8 boots, it
recalls its last known light levels until new levels are provided by the control system.
LED Indicators
The LEDs indicate the following:
• NET: Yellow - Lights to indicate activity on the Cresnet bus
• POWER: Green - On indicates that power is supplied to the unit.
• SETUP: Red - Flashing indicates that the device is in TSID mode.
• R, G, B, W: Red - On indicates that the channel is on.
• OVR: Red - On indicates that Override mode is enabled. The R, G, B, and W LEDs also light.
Additional Information
Scan or click the QR code for detailed product information.
DIN-2LEDPWM8
Compliance and Legal
Original Instructions: The U.S. English version of this document is the original instructions. All
other languages are a translation of the original instructions.
Regulatory Model: M201903002
As of the date of manufacture, the product has been tested and found to comply with
specifications for CE marking.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following
conditions: (1) This device may not cause harmful interference and (2) this device must accept
any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada (IC) Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
The product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at
www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specific information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, and Cresnet are either trademarks or registered trademarks of
Crestron Electronics, Inc. in the United States and/or other countries. UL is either a trademark
or registered trademark of Underwriters Laboratories, Inc. in the United States and/or other
countries. Other trademarks, registered trademarks, and trade names may be used in this
document to refer to either the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not
responsible for errors in typography or photography.
©2019 Crestron Electronics, Inc.
Crestron Electronics, Inc.
15 Volvo Drive, Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Quick Start - Doc. 7949A
(2048110)
04.19
Specifications subject to
change without notice.