Aurora Multimedia Mini Modem 33.6 Manuel utilisateur

Catégorie
Convertisseurs série / répéteurs / isolateurs
Taper
Manuel utilisateur
Mini Modem
Industrial Grade
33.6Kbps Data
14.4Kbps Fax
Panja (AMX) & Crestron Version Setup Manual
010101
So Simple.
Only 3.8” x 2.4” x 1”
Mini Modem
Designed for easy installation with RS-232 controllable equipment, the Mini Modem
is an installer’s answer to a time consuming and complicated process. The Mini
Modem comes with the initialization string preprogrammed and all the cables needed
to connect to the equipment. Mounting is not a problem because of its size. With the
enclosed hook & loop tape, this modem can be easily attached to just about any
surface area. The LED indicators on the front panel allow for viewing of the signals
and power. For locations that need some privacy, the modem has a speaker on/off
switch in addition to the software commands.
The Mini Modem is a winner when it comes to industrial environments. The enclosure
which is molded from UL94V0 plastic is just the beginning. Only top of the line
semiconductors are used, especially the RS-232 port. The 15KV ESD protection
rating ensures reliable operation in static prone environments. The DC power input
has a large voltage range of 9V-24V and is not polarity sensitive. Plugging an RJ-11
phone cord into this unit has never been easier. There is only one line jack so there is
no confusion as with a two jack system which has a line and phone connection.
So Simple.
The perfect modem for Panja & Crestron systems
Aurora has made this modem with control systems in mind. We designed a cable for
the RS-232 port for use on either brand. Our preprogrammed initialization strings
allow quick setup without having to know all the different codes that vary from one
manufacturer to another. Basically, we have standardized a modem for this and many
other applications. Everything is included for mounting and connecting to the system.
The advantage of standardization is simple, one modem for many types of systems
with no changes to the compatibility. We have successfully transferred files over the
modem at 19.2Kbps for the Panja (AMX) and 115Kbps for the Crestron. Application
notes and programming tips can be found at www.auroramultimedia.com
Installation is easy
1. Find the mounting location for the modem and attach the hook & loop tape to the
bottom of the modem by peeling away the adhesive strip. Next, remove the other
adhesive strip and press firmly onto the surface where it is to be located.
2. Connect the 9 pin male end of the RS-232 cable labeled MM to the Mini Modem.
The other end will connect to the RS-232 port of the equipment. Gender and size of
the connector is based on the equipment it is used with. The product code located on
the packing slip determines the cables included with the Mini Modem.
Control System
Power Adaptor
Custom Molded
Control System RS-232 Cable
Standardized Configuration Strings
Basic Modem Commands
AMX & Crestron Modem Commands
The Mini Modem has the initialization string preprogrammed at the factory and will be
marked accordingly on the box. The modem can be changed as described below.
Dial ATDn (n=phone number) Redial ATD L
Hangup ATH 0 Escape +++
Echo ATE0 (off) ATE1 (on) Factory AT&F0
Panja String: AT&F0 (ENTER) ATE0L3S0=1&Q0&D0&K0&W0&Y0 (ENTER)
Crestron String:AT&F0 (ENTER) ATE0L3S0=1&D0&K5&W0&Y0 (ENTER)
Note: We have found the strings to provide the most reliability for communications up
to 115Kbps for Crestron and 19.2Kbps for Panja (AMX).
If the modem is used for a desktop computer system, do not use the Panja/Crestron
cable. Instead use a 9 pin female - 9 pin female pin-pin with all hardware handshaking
lines and use the following string: AT&F0E0&W0 (ENTER)
Specifications
Modem Data Rate: 300 - 33,600 baud
Fax Data Rate: 2400 - 14,400bps
Size: 3.8”x2.4”x1.0”
Enclosure: UL94V0 Black Plastic
Power: 9v-24v DC / .5 watts Non-polarity sensitive
RS-232 Rating: 300 -115Kbps 15KV ESD Protection
FCC Ratings: FCC68 & FCC15
5 4 3 2 1
9 8 7 6
1 - DCD
2 - RXD
3 - TXD
4 - DTR
5 - GND
6 - DSR
7 - RTS
8 - CTS
9 - RI
Mini Modem RS-232 9 Pin Female (DCE)
9v DC Wall Adaptor
3. Plug the RJ-11 cable into the Mini Modem and then into the analog phone jack.
4. Connect the 9V DC round connector into the Mini Modem power connector.
Next, plug the transformer with the AC prongs into a 120V AC wall outlet (Note: If
you are using the control system power cable, plug the end with the green
connector into the AXLINK or CRESNET). The CD LED will briefly light up, the
green power LED will remain on, and the red DTR LED will be on as well.
FCC Part 15 Statement
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- I ncrease the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: "How to Identify and Resolve Radio-TV Interference Problems." This
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this
equipment under Federal Communications Commissions rules.
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved
equipment or unshielded cables is likely to result in interference to radio & television reception.
FCC Part 68 Notice
This equipment complies with FCC rules, Part 68. On the, bottom side of this equipment is a label that contains, among other information, the
FCC Registration Number and Ringer Equivalence Number (REN) for this equipment. If requested, provide this information to your telephone
company.
The (REN) is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices Ring when
your number is called. In most, but not all areas, the sum of the REN`s of all devices should not exceed five (5.0). To be certain of the number of
devices you may connect to your line, as determined by the REN, you should call your local telephone company to determine the maximum
REN for your calling area.
If this equipment causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they
will notify you in advance. But if advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a
complaint with the FCC.
Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of
your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
If you experience trouble with this equipment, please contact the manufacturer for warranty/repair information. The telephone company may
ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not
malfunctioning.
Canadian DOC Notice
The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network
protective, operation and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s).
The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure
that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using
and acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the
user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the
equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic
water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or
electrician, as appropriate.
NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals
allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only
to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.
"This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications."
"Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class
B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada."
Aurora Multimedia Corp.
300 Buckelew Avenue Suite 201
Jamesburg, NJ 08831
Voice: (732) 656-9026 Fax: (732) 656-9685
www.auroramultimeida.com
Tips
Use with Panja (AMX) Axcent 3: The auto baud can sometimes hangup the
modem at certain times when it checks for the computer. If this becomes a
problem, enter the string below in the axcess Define_Start section:
SEND_COMMAND 0,’SET BAUD 19200’
The 19200 can be substituted with 1200, 4800, 9600 baud rates. Remember the
baud rate since it will take it out of auto baud!
Use with Crestron: Set the Crestron frame for 38400 or less for the most
reliability. This is to assure proper uploads and downloads to network devices
such as touch panels. Using a higher baud rate will exceed the 38400 Crestron
network bus speed thus causing errors. If you are using version 1.40.07 of SIMPL
Windows, make certain you have the patch cmvpt32.dll dated 5/04/00 for the
viewport. If not, uploading programs to the frame will not be possible. If after
loading a program there is no communication to make a permanent memory
image, cancel the function then select send program from the file transfer (top
menu bar) again. Next, select permanent memory image only and it will carry out
the function. Crestron states they will look into the problem.
Note: Version 1.50.00 and above does not have the above problem.
In general practice, try not to send strings out through the master programming port
when using a control system with a modem. Modems in general will respond with an
error response making it harder to connect up to the unit. It is good practice to issue
the (enter)AT(enter) command out the programming port upon startup so the modem
can lock onto the baud rate of the unit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Aurora Multimedia Mini Modem 33.6 Manuel utilisateur

Catégorie
Convertisseurs série / répéteurs / isolateurs
Taper
Manuel utilisateur

dans d''autres langues