dBTechnologies VIO S218F Le manuel du propriétaire

Taper
Le manuel du propriétaire
2x18” Flyable Active Bass-reflex Subwoofer
MANUALE D’USO – Sezione 1
USER MANUAL - Section 1
Le avvertenze nel presente manuale devono essere osservate congiuntamente al “MANUALE D’USO - Sezione2”.
The warnings in this manual must be observed together with the “USER MANNUAL- Section 2”.
2
VIO S218F Cod. 420120416 REV. 1.0
EMI CLASSIFICATION
FCC CLASS A STATEMENT
EMI CLASSIFICATION
According to the standards EN 55032 and 55035 this is a Class A equipment, designed and suitable to operate for
professional use.
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may
cause radio interference
Any changes or modications not expressly approved by the party responsible for compliance could void the
users authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
WARNING
Make sure that the loudspeaker is securely installed in a stable position to avoid any injuries or damages to
persons or properties. For safety reasons do not place one loudspeaker on top of another without proper
fastening systems. Before hanging the loudspeaker check all the components for damages, deformations, missing
or damaged parts that may compromise safety during installation. If you use the loudspeakers outdoor avoid
spots exposed to bad weather conditions. Contact dBTechnologies for accessories to be used with the speakers.
dBTechnologies will not accept any responsibility for damages caused by inappropiate accessories or additional
devices.
Features, specication and appearance of products are subject to change without notice.
dBTechnologies reserves the right to make changes or improvements in design or manufacturing without
assuming any obligation to change or improve products previously manufactured.
Changes or modications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
NFC MODULE
This equipment contains a transmitter module
FCC ID:2ADDV-NFCVIO
IC:12207A-NFCVIO
3
VIO S218F Cod. 420120416 REV. 1.0
IMPORTANT SAFETY INSTRUCTIONS:
1. Read these instructions
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments /accessories specied by the manufacturer.
12. Use only with the cart, stand tripod, bracket, or table specied by the manufacturer, or sold with
the apparatus. When a cart is used, use caution, when moving the cart/apparatus combination to avoid injury
from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
ADDITIONAL SAFETY INSTRUCTIONS:
• No naked ame sources, such as lighted candles, should be placed on the apparatus
• Do not use the apparatus in tropical climates
4
VIO S218F Cod. 420120416 REV. 1.0
Make sure that the loudspeaker is securely installed in a stable position to avoid any injuries or damages to
persons or properties. For safety reasons do not place one loudspeaker on top of another without proper
fastening systems. Before hanging the loudspeaker check all the components for damages, deformations, missing
or damaged parts that may compromise safety during installation. If you use the loudspeakers outdoor avoid
spots exposed to bad weather conditions.
Contact dBTechnologies for accessories to be used with the speakers. dBTechnologies will not accept any
responsibility for damages caused by inappropiate accessories or additional devices.
WARNING
5
VIO S218F Cod. 420120416 REV. 1.0
ITALIANO
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
6
VIO S218F Cod. 420120416 REV. 1.0
INDICE
Italiano
1. INFORMAZIONI GENERALI ................................................................................................... 7
BENVENUTI! ........................................................................................................................ 7
PANORAMICA INTRODUTTIVA .......................................................................................... 7
RIFERIMENTI PER LUTENTE ................................................................................................ 7
CARATTERISTICHE MECCANICHE E ACUSTICHE ................................................................ 8
DIMENSIONI E PESO .................................................................................................................................. 8
CARATTERISTICHE ACUSTICHE .................................................................................................................. 8
MECCANICA ............................................................................................................................................... 9
ACCESSORI ............................................................................................................................................... 10
CARATTERISTICHE DELLA SEZIONE DI AMPLIFICAZIONE E DI CONTROLLO ................. 11
SEZIONE DI INGRESSO, USCITA E DI CONTROLLO .................................................................................. 12
SEZIONE DI ALIMENTAZIONE .................................................................................................................. 14
2. PARAMETRI DI CONFIGURAZIONE .................................................................................... 15
3. COLLEGAMENTI ................................................................................................................... 16
COLLEGAMENTO E RILANCIO DELLALIMENTAZIONE............................................................................. 16
COLLEGAMENTO E RILANCIO DEL SEGNALE AUDIO ............................................................................. 16
COLLEGAMENTO E RILANCIO DEL SEGNALE RDNET ............................................................................. 17
4. CONTROLLO REMOTO .......................................................................................................... 18
5. INSTALLAZIONE E CONFIGURAZIONE ............................................................................... 19
CONTENUTO DELLA CONFEZIONE .................................................................................. 19
INSTALLAZIONE IN CONFIGURAZIONI MULTIPLE ........................................................... 19
CONFIGURAZIONE IN APPENDIMENTO .......................................................................... 21
CONFIGURAZIONE CARDIOIDE ....................................................................................... 21
CONFIGURAZIONE ENDFIRE ............................................................................................ 22
CONFIGURAZIONE IN APPOGGIO ................................................................................... 22
6. RISOLUZIONE DEI PROBLEMI ............................................................................................. 23
7. AGGIORNAMENTO DEL FIRMWARE .................................................................................. 24
8. SPECIFICHE TECNICHE ......................................................................................................... 25
GENERALE ................................................................................................................................................ 25
DATI ACUSTICI .......................................................................................................................................... 25
AMPLIFICATORE ....................................................................................................................................... 25
PROCESSORE ............................................................................................................................................ 25
INTERFACCIA UTENTE .............................................................................................................................. 26
INGRESSI E USCITE ................................................................................................................................... 26
SPECIFICHE DI ALIMENTAZIONE (ASSORBIMENTO) ............................................................................... 26
SPECIFICHE MECCANICHE ....................................................................................................................... 27
7
VIO S218F Cod. 420120416 REV. 1.0
1. INFORMAZIONI GENERALI
Grazie per aver acquistato un prodotto progettato e sviluppato in Italia da dBTechnologies! Questo subwoofer è
frutto di una lunga esperienza nel campo della diffusione sonora. Impiega soluzioni ottimizzate in campo acustico
ed elettronico, oltre che nella scelta dei materiali.
La famiglia VIO prosegue la nuova stagione dBTechnologies nel campo della diffusione sonora per le applicazioni
live indoor e outdoor di medie e grandi dimensioni.
VIO S218F è un subwoofer attivo professionale, che, nell’utilizzo con i line-array VIO, permette di ottenere un
sistema completo, dalle prestazioni acustiche ottime su un range di frequenze esteso. Grazie alla staffa integrata il
subwoofer è appendibile tramite il ybar DRK-218F.
Le sue caratteristiche principali sono:
Per utilizzare al meglio il vostro diffusore VIO consigliamo di:
2 woofer da 18” (voice coil: 4”)
2 amplicatori in classe D (2 x 1600 W RMS)
predisposizioni integrate che garantiscono congurabilità ed ergonomicità nell’utilizzo con altri
subwoofer VIO S218F
cabinet di alta qualità in legno multistrato, con nitura in poliurea che aumenta la durevolezza
superciale
tecnologia Floating ADC, sviluppata per un perfetto isolamento da interferenze, rumori o ronzii,
dell’ingresso audio
rilanci di alimentazione, audio e di rete per un cablaggio ottimizzato
controllo RDNet on-board e software predittivi e di gestione remota (DBTECHNOLOGIES COMPOSER,
EASE, EASE FOCUS 3, AURORA NET)
accessori dedicati (carrello DO-VIOS218F) per la movimentazione in sicurezza e per l’appendimento
(DRK-218F)
leggere il manuale d’uso quick start presente nella confezione e questo manuale d’uso completo in
ogni sua parte e conservarlo per tutta la durata di vita del prodotto.
registrare il prodotto sul sito http://www.dbtechnologies.com nella sezione “SUPPORTO”.
conservare prova d’acquisto e GARANZIA (Manuale d’uso “sezione 2”).
Italiano
BENVENUTI!
PANORAMICA INTRODUTTIVA
RIFERIMENTI PER L’UTENTE
8
VIO S218F Cod. 420120416 REV. 1.0
CARATTERISTICHE MECCANICHE E ACUSTICHE
DIMENSIONI E PESO
CARATTERISTICHE ACUSTICHE
Il cabinet in legno, rivestito in poliurea, pesa 100 kg (220 lbs).
Le misure sono: 1300 mm (L), 520 mm (A), 800 mm (P).
Italiano
La progettazione acustica di VIO S218F coniuga un’ampia supercie di radiazione con dimensioni compatte per un
subwoofer di questa fascia di utilizzo. Grazie ai controlli gestiti da DSP, la direttività in congurazione di utilizzo
multipla ne rende versatile l’utilizzo.
1300
800
520
9
VIO S218F Cod. 420120416 REV. 1.0
MECCANICA
Lergonomia del subwoofer ed il rapido montaggio in congurazione multipla sono garantiti da:
LATI [vista A]
1) Maniglie (2 per lato). Facilitano il sollevamento quando il subwoofer è in posizione orizzontale.
2) Staffe integrate per il ssaggio al ybar DRK-218F o per impilare più subwoofer.
3) Piedini plastici (4 su un lato) per utilizzo in congurazione verticale (per questo utilizzo è necessario un
ssaggio addizionale, non incluso).
LATO SUPERIORE [vista B]
4) Sedi di appoggio per piedi inferiori [8]. Permettono il posizionamento stabile di più VIO S218F sovrapposti.
5) Fori per il montaggio del y-bar DRK-212/DRK-210.
6) Scanalature passacavi. Permettono di far passare i cavi tra i subwoofer per un cablaggio ordinato e
semplice in congurazione cardioide.
RETRO E LATO INFERIORE [vista C]
7) Scanalature passacavi (2 sul lato inferiore). Permettono di far passare i cavi sotto al subwoofer per un
cablaggio, ordinato e semplice in congurazione cardioide.
8) Piedi inferiori (4 in totale). Stabilizzano l’appoggio e la costruzione di congurazioni a subwoofer sovrapposti.
Italiano
A
C
B
1
2
2
3
7
4
5
8
6
10
VIO S218F Cod. 420120416 REV. 1.0
ACCESSORI
Per un rapido montaggio, sono previsti come opzionali i seguenti accessori:
DRK-218F, ybar per l’utilizzo in appendimento di subwoofer VIO S218F
DO-VIOS218F, carrello per il trasporto dei subwoofer VIO S218F. E’ adatto all’utilizzo con un carrello
elevatore
DRK-212, ybar per l’utilizzo in appoggio di moduli VIO-L212
DRK-210, ybar per l’utilizzo in appoggio di moduli VIO-L210
Italiano
ATTENZIONE!
Utilizzare solo gli accessori e le congurazioni indicate nel presente manuale e operare in accordo
a quanto indicato nei manuali relativi agli accessori.
DRK-210, sul top di un VIO S218F permette di posizionare al massimo 3 moduli VIO L210 in
congurazione stacked. Ogni dettaglio installativo deve essere vericato con il software gratuito
dBTechnologies COMPOSER, disponibile sul sito www.dbtechnologies.com.
Per ogni ulteriore informazione si prega di consultare i manuali relativi.
Per tutti gli aggiornamenti sugli accessori consultare il sito www.dbtechnologies.com
DRK-210
DO-VIOS218F
DRK-218F
DRK-212
11
VIO S218F Cod. 420120416 REV. 1.0
CARATTERISTICHE DELLA SEZIONE DI AMPLIFICAZIONE E DI CONTROLLO
I due amplicatori in classe D sono il cuore dei subwoofer VIO S218F. Permettono di erogare no a 1600 W RMS
per sezione, per un totale di 3200 W RMS. Il funzionamento è silenzioso ed efciente.
Il controllo del sistema è afdato a un potente DSP che rende possibile la congurazione immediata e semplice
in qualsiasi contesto di utilizzo. Grazie alla possibilità di collegamento in rete con RDNet, i parametri sul pannello
possono essere controllati in remoto, grazie al software “AURORA NET” (vedere il paragrafo PARAMETRI DI
CONFIGURAZIONE).
Il pannello amplicatore posto sul retro del subwoofer è caratterizzato da:
SEZIONE DI
INGRESSO, USCITA E
CONTROLLO
SEZIONE DI
ALIMENTAZIONE
Italiano
Sezione di Ingresso, Uscita e Controllo
Sezione di Alimentazione
P
P
U
U
S
S
H
H
VIO S218
VIO S218F
(flyable)
P
P
U
U
S
S
H
H
P
P
U
U
S
S
H
H
Data Out
Data In
R
R
D
D
N
N
e
e
t
t
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED
IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
1
1
0
0
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
M
M
A
A
I
I
N
N
S
S
L
L
I
I
N
N
K
K
F
F
U
U
L
L
L
L
-
-
R
R
A
A
N
N
G
G
E
E
M
M
A
A
I
I
N
N
S
S
I
I
N
N
P
P
U
U
T
T
OFF
ON
OFF
ON
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
9
9
,
,
4
4
A
A
m
m
a
a
x
x
)
)
2
2
1
1
5
5
0
0
W
W
m
m
a
a
x
x
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
7
7
,
,
7
7
A
A
m
m
a
a
x
x
)
)
8
8
8
8
0
0
W
W
m
m
a
a
x
x
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
6
6
,
,
6
6
A
A
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
1
1
2
2
,
,
3
3
A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
T
T
1
1
0
0
A
A
L
L
2
2
5
5
0
0
V
V
~
~
)
)
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
T
T
5
5
A
A
L
L
2
2
5
5
0
0
V
V
~
~
)
)
12
VIO S218F Cod. 420120416 REV. 1.0
SEZIONE DI INGRESSO, USCITA E DI CONTROLLO
1. POLARITY
Permette di invertire la polarità del subwoofer. Può essere utile per allineare la fase tra vari subwoofer o fra un
subwoofer e i moduli line-array. Vedere per ogni ulteriore dettaglio il capitolo PARAMETRI DI CONFIGURAZIONE.
3. CARDIOID PRESET
Permette di congurare l’utilizzo cardioide con un solo comando. In caso sia selezionata questa modalità, il led
“Active” è acceso ed i valori di polarità e ritardo risultano bypassati.
4. STATUS LED
Led relativi al funzionamento del modulo. La tabella nella pagina seguente riepiloga e sintetizza il signicato dei
vari LED.
6. SYSTEM TEST
Effettua un test con segnale sweep per vericare l’integrità del woofer. Questo test non va considerato esaustivo,
ma solo un primo controllo nell’analisi di eventuali problematiche.
2. DELAY
I due selettori rotativi permettono di impostare il ritardo del segnale in uscita nel range 0-9.9 ms. Il selettore di
sinistra regola il valore unitario, quello di destra il valore decimale.
5. SUBWOOFER ATTENUATION
Permette di regolare l’attenuazione del subwoofer. Porre a 0 dB prima di iniziare a congurare il subwoofer ed il
sistema.
7. USB DATA SERVICE
Grazie a questa porta standard USB di tipo B è possibile, tramite PC e USB BURNER MANAGER, aggiornare il
rmware del prodotto. Per ulteriori informazioni consultare il sito http://www.dbtechnologies.com alla sezione
“DOWNLOADS” ed il capitolo AGGIORNAMENTO DEL FIRMWARE.
P
P
U
U
S
S
H
H
VIO S218
VIO S218F
(flyable)
P
P
U
U
S
S
H
H
P
P
U
U
S
S
H
H
Data Out
Data In
R
R
D
D
N
N
e
e
t
t
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED
IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
Italiano
1
10
2
11
3
12
4
13
5 6 7 8 9
13
VIO S218F Cod. 420120416 REV. 1.0
9. RDNet DATA IN/OUT
Sezione compatibile con cavi di rete dotati di connettori di tipo etherCON/RJ45. In particolare:
• “Data In” deve essere collegato a dispositivi come RDNet Control 2 o Control 8
• “Data Out” viene utilizzato per il rilancio della rete ad ulteriori dispositivi in congurazione daisy-chain
Italiano
10. BALANCED AUDIO INPUT
Ingresso compatibile con cavi XLR blanciati. Si utilizza per il collegamento in ingresso del segnale audio
proveniente dal mixer, o da un altro speaker o subwoofer in congurazione daisy chain.
13. HPF XOVER OUTPUT
Uscita compatibile con cavi XLR blanciati. Nel caso l’uscita audio del subwoofer sia inviata direttamente ad un
diffusore (es. VIO-L210), è possibile utilizzare un segnale audio ltrato alla frequenza di Xover. Questa frequenza è
selezionata con l’apposito controllo XOVER [12].
8. RDNET CONTROL LED
I Led sono relativi al funzionamento in rete (RDNet) del modulo. In particolare:
• “Link” acceso segnala che la rete RDNet è attiva e ha riconosciuto il dispositivo
• “Active” in modalità lampeggiante indica che il trafco dati è presente
• “Remote Preset Active” avvisa che tutti i controlli locali sul pannello amplicatore sono by-passati dal
controllo remoto RDNet
12. XOVER LPF
Seleziona la frequenza XOVER (70-75-80-85-90-95-95-100-105-Fullrange) applicata all’uscita [13]. La posizione
Service/User va invece utilizzata per lo stato di aggiornamento del rmware o per richiamare un’impostazione
USER (vedi il manuale di DBTECHNOLOGIES NETWORK). Vedi anche la sezione AGGIORNAMENTO DEL FIRMWARE.
TIPO LED FASE DI ACCENSIONE
DELLO SPEAKER
IN FUNZIONE
NORMALE
WARNING
GENERICO
BLOCCO PER
ANOMALIA DELLO
SPEAKER
LIMITER SPENTO SI ACCENDE IN
CASO DI
INTERVENTO
SI ACCENDE IN
CASO DI
INTERVENTO
LAMPEGGIO CICLICO
SIGNAL SPENTO SEGNALAZIONE
NORMALE DI
AUDIO IN
INGRESSO
SEGNALAZIONE
NORMALE DI
AUDIO IN
INGRESSO
SPENTO
MUTE/
PROT
ACCESO SPENTO LAMPEGGIO
CICLICO
ACCESO
READY SPENTO ACCESO ACCESO SPENTO
Tabella di segnalazione dei LED
11. BALANCED AUDIO LINK
Uscita compatibile con cavi XLR blanciati. Si utilizza per il rilancio del segnale audio agli altri VIO S218F in
congurazione daisy-chain.
14
VIO S218F Cod. 420120416 REV. 1.0
SEZIONE DI ALIMENTAZIONE
15. CONNETTORE DI ALIMENTAZIONE “MAINS INPUT
Compatibile con connettore powerCON TRUE1®. Alimentazione full range.
14. MAINS FUSES
Alloggio per i fusibili di rete.
16. RILANCIO DI ALIMENTAZIONE “MAINS LINK”
Compatibile con connettore tipo powerCON TRUE1® per il rilancio dell’alimentazione ad altri moduli. Per
conoscere il numero massimo di moduli che si possono connettere in un sistema rilanciato, consultare la sezione
SPECIFICHE TECNICHE di questo manuale.
ATTENZIONE!
I connettori di questa sezione svolgono anche la funzione di interruttori di alimentazione.
Non ostruire le alette posteriori di raffreddamento dell’amplicatore. In caso di
surriscaldamento eccessivo, il volume audio viene ridotto gradualmente no alla
stabilizzazione termica del modulo. Il livello viene ristabilito automaticamente al
raggiungimento della corretta temperatura di funzionamento.
In caso di malfunzionamento, interrompere immediatamente l’alimentazione, e
scollegare il modulo dalla rete. Rivolgersi ad un centro di assistenza autorizzato.
Non tentare in nessun modo di aprire l’amplicatore.
Utilizzare solo cavi dotati di connettori originali Neutrik®, di alta qualità. Controllarne
periodicamente l’integrità.
1
1
0
0
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
M
M
A
A
I
I
N
N
S
S
L
L
I
I
N
N
K
K
F
F
U
U
L
L
L
L
-
-
R
R
A
A
N
N
G
G
E
E
M
M
A
A
I
I
N
N
S
S
I
I
N
N
P
P
U
U
T
T
OFF
ON
OFF
ON
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
9
9
,
,
4
4
A
A
m
m
a
a
x
x
)
)
2
2
1
1
5
5
0
0
W
W
m
m
a
a
x
x
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
7
7
,
,
7
7
A
A
m
m
a
a
x
x
)
)
8
8
8
8
0
0
W
W
m
m
a
a
x
x
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
6
6
,
,
6
6
A
A
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
1
1
2
2
,
,
3
3
A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
T
T
1
1
0
0
A
A
L
L
2
2
5
5
0
0
V
V
~
~
)
)
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
T
T
5
5
A
A
L
L
2
2
5
5
0
0
V
V
~
~
)
)
15 16
14
Italiano
15
VIO S218F Cod. 420120416 REV. 1.0
2. PARAMETRI DI CONFIGURAZIONE
I parametri principali di VIO S218F vengono utilizzati per ottimizzare una congurazione multipla
(es. cardioide, endre).
CARDIOID PRESET - Questo parametro può essere
applicato in una congurazione come quella in
gura (cardioide a 3 elementi).
Va attivato solo sul subwoofer centrale, il quale
va meccanicamente ruotato rispetto agli altri.
Quando attivo, il comando Cardioid Preset
imposta automaticamente i valori di Delay e
Polarity (i cui controlli sici quindi sono by-
passati).
Esempio di congurazione cardioide a 3 elementi
Una volta che i vari parametri sono stati calcolati con DBTECHNOLOGIES COMPOSER, riportarne i valori sui
controlli presenti sul pannello amplicatore.
Se si effettua un controllo remoto tramite connessioni RDNet è possibile controllare tutti i parametri del
subwoofer tramite il software gratuito AURORA NET. E’ possibile scaricarlo nella sezione DOWNLOADS del sito
www.dbtechnologies.com. Per ulteriori informazioni si rimanda al manuale completo di questo software.
E’ buona norma che anche in caso di controllo remoto, i valori iniziali di progetto calcolati con
DBTECHNOLOGIES COMPOSER siano replicati sul pannello amplicatore di VIO S218F prima di procedere
all’installazione denitiva.
ATTENZIONE!
Se i parametri di controllo sono remotati con RDNet, i parametri locali sui pannelli dei subwoofer non
sono attivi.
Le ultime impostazioni scelte e salvate su VIO S218F (con l’utilizzo di AURORA NET), possono
essere successivamente richiamate sul subwoofer in assenza di controllo remoto RDNet. Per il
salvataggio su Aurora premere il pulsante STORE nella sezione LOAD/SAVE. Per richiamare le
impostazioni è sufciente ruotare il rotary Xover sulla posizione Service/User.
Italiano
16
VIO S218F Cod. 420120416 REV. 1.0
3. COLLEGAMENTI
COLLEGAMENTO E RILANCIO DELLALIMENTAZIONE
COLLEGAMENTO E RILANCIO DEL SEGNALE AUDIO
Nell’illustrazione sopra è mostrato un generico caso di collegamento. Utilizzare allo scopo cavi con connettori
powerCON TRUE1® (è fornito un solo cavo in dotazione per l’alimentazione a confezione).
Collegare l’alimentazione del subwoofer 1 (FULL-RANGE MAINS INPUT)
Rilanciare l’alimentazione dal subwoofer 1 al subwoofer 2, collegando l’uscita (MAINS LINK) del subwoofer 1
all’ingresso (FULL-RANGE MAINS INPUT) del subwoofer 2 (cavo link non fornito)
Ripetere quest’ultima operazione no a collegare il numero massimo ammesso di subwoofer (vedere il
capitolo SPECIFICHE TECNICHE)
Per il collegamento del segnale audio connettere innanzitutto la sorgente sonora nell’ingresso “Input” del
subwoofer. Per il rilancio a un altro subwoofer collegare con un cavo bilanciato XLR l’uscita “Link” del primo
subwoofer all’ingresso “Input” del secondo, e così via.
P
P
U
U
S
S
H
H
VIO S218
VIO S218F
(flyable)
PPUUSSHH
PPUUSSHH
Data Out
Data In
RRDDNNeett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
P
P
U
U
S
S
H
H
VIO S218
VIO S218F
(flyable)
PPUUSSHH
PPUUSSHH
Data Out
Data In
RRDDNNeett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
SUBWOOFER 2
SUBWOOFER 2
SUBWOOFER 1
SUBWOOFER 1
POWER SOURCE
AUDIO SOURCE
1
1
0
0
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
M
M
A
A
I
I
N
N
S
S
L
L
I
I
N
N
K
K
F
F
U
U
L
L
L
L
-
-
R
R
A
A
N
N
G
G
E
E
M
M
A
A
I
I
N
N
S
S
I
I
N
N
P
P
U
U
T
T
OFF
ON
OFF
ON
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
9
9
,
,
4
4
A
A
m
m
a
a
x
x
)
)
2
2
1
1
5
5
0
0
W
W
m
m
a
a
x
x
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
7
7
,
,
7
7
A
A
m
m
a
a
x
x
)
)
8
8
8
8
0
0
W
W
m
m
a
a
x
x
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
6
6
,
,
6
6
A
A
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
1
1
2
2
,
,
3
3
A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
110000--112200VV~~ ((TT1100AA LL 225500VV~~))
222200--224400VV~~ ((TT55AA LL 225500VV~~))
1
1
0
0
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
M
M
A
A
I
I
N
N
S
S
L
L
I
I
N
N
K
K
F
F
U
U
L
L
L
L
-
-
R
R
A
A
N
N
G
G
E
E
M
M
A
A
I
I
N
N
S
S
I
I
N
N
P
P
U
U
T
T
OFF
ON
OFF
ON
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
(
(
9
9
,
,
4
4
A
A
m
m
a
a
x
x
)
)
2
2
1
1
5
5
0
0
W
W
m
m
a
a
x
x
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
(
(
7
7
,
,
7
7
A
A
m
m
a
a
x
x
)
)
8
8
8
8
0
0
W
W
m
m
a
a
x
x
2
2
2
2
0
0
-
-
2
2
4
4
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
6
6
,
,
6
6
A
A
1
1
0
0
0
0
-
-
1
1
2
2
0
0
V
V
~
~
5
5
0
0
-
-
6
6
0
0
H
H
z
z
1
1
2
2
,
,
3
3
A
A
MAINS FUSES
(REPLACE FUSES WITH SAME RATINGS)
(REMPLACER FUSIBLES AVEC LE MÊME TYPE)
110000--112200VV~~ ((TT1100AA LL 225500VV~~))
222200--224400VV~~ ((TT55AA LL 225500VV~~))
Italiano
17
VIO S218F Cod. 420120416 REV. 1.0
Per il rilancio a uno speaker collegare con un cavo bilanciato XLR l’uscita HPF Xover Output del subwoofer
all’ingresso “Input” dello speaker. Impostare poi la frequenza di taglio del crossover dalla manopola “LPF”.
PPUUSSHH
VIO S218
VIO S218F
(flyable)
PPUUSSHH
PPUUSSHH
Data Out
Data In
RRDDNNeett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
PPUUSSHH
VIO S218
VIO S218F
(flyable)
P
P
U
U
S
S
H
H
P
P
U
U
S
S
H
H
Data Out
Data In
R
R
D
D
N
N
e
e
t
t
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
PPUUSSHH
VIO S218
VIO S218F
(flyable)
P
P
U
U
S
S
H
H
P
P
U
U
S
S
H
H
Data Out
Data In
R
R
D
D
N
N
e
e
t
t
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
P
P
U
U
S
S
H
H
VIO S218
VIO S218F
(flyable)
PPUUSSHH
PPUUSSHH
Data Out
Data In
RRDDNNeett
Link
Active
Remote
Preset Active
Expansion Card
DESIGNED & DEVELOPED IN ITALY
System test
Push and Hold to test
Active
Signal
Mute/Prot
Balanced
Audio
Input Link
USB Data Service
Status
Mute
Delay [ms] Cardioid presetPolarity
HPF
Xover output
LPF
Subwoofer Attenuation
Xover [Hz]
Service / User
When green light is on, polarity and delay are bypassed
0.0 -6dB
60
1.1 -3dB
70
2.2 -2dB
75
3.3 -1dB
80
4.4 0dB
85
90
5.5
6.6 -24dB
100
7.7 -18dB
110
8.8 -12dB
Fullrange
9.9 -9dB
180°
Ready
Limiter
COLLEGAMENTO E RILANCIO DEL SEGNALE RDNET
Per il controllo remoto, collegare il Data Input del subwoofer al controller hardware (RDNet Control 2 o
RDNet Control 8) con cavi equipaggiati con connettori etherCON. In caso di rilancio connettere il Data Output del
primo subwoofer al Data Input del secondo e inne dal secondo subwoofer al top. Una volta accesi i diffusori e
dopo aver richiesto “GoOnline” da software AURORA NET, i LED “Link” indicheranno l’avvenuto collegamento.
I LED “Active” inizieranno a lampeggiare in presenza di trafco dati. E’ possibile collegare in daisy chain no a un
massimo di 32 dispositivi RDNet.
I cavi devono essere opportunamente dimensionati e la progettazione, installazione e verica
dell’impianto devono essere effettuate esclusivamente da personale qualicato. AEB industriale
declina ogni responsabilità in caso di utilizzo di cavi non idonei, non certicati e non compatibili col
corretto dimensionamento dell’impianto e le normative in vigore per il Paese di utilizzo
Sostituire i cavi eventualmente danneggiati, per evitare malfunzionamenti ed una scarsa qualità del
suono (o la trasmissione dati in caso di collegamento RDNet).
ATTENZIONE!
LOUDSPEAKER
SUBWOOFER 2
SUBWOOFER
SUBWOOFER 1
RDNET CONTROL
Italiano
18
VIO S218F Cod. 420120416 REV. 1.0
4. CONTROLLO REMOTO
Italiano
Tramite software AURORA NET è possibile gestire in tempo reale diversi parametri del subwoofer VIO S218F.
Nel dettaglio:
Monitorare il segnale in ingresso e in uscita
Visualizzare l’eventuale presenza di compressione audio sul componente acustico
Attenuare il segnale in ingresso
Mettere in MUTE e ascoltare in SOLO il subwoofer
Monitorare la temperatura dell’amplificatore
Salvare impostazioni in preset e richiamarli in seguito da remoto
Equalizzare il subwoofer
Aggiungere delay
Attivare la modalità cardioide
19
VIO S218F Cod. 420120416 REV. 1.0
5. INSTALLAZIONE E CONFIGURAZIONE
CONTENUTO DELLA CONFEZIONE
Vericare che il contenuto dell’imballo del modulo VIO S218F sia completo. L’imballo contiene:
subwoofer VIO S218F
cavo powerCON TRUE1®
quick start e documentazione relativa alla garanzia
Italiano
INSTALLAZIONE IN CONFIGURAZIONI MULTIPLE
ATTENZIONE!
Il prodotto e gli accessori devono essere utilizzati solo da personale esperto! Assicurarsi che l’installazione
sia posizionata in modo stabile e sicuro per scongiurare ogni condizione di pericolo per persone, animali e/o
cose.
Lutilizzatore è tenuto a seguire le regolamentazioni e le leggi cogenti in materia di sicurezza nel Paese in cui
si utilizza il prodotto. Per l’utilizzo in sicurezza, vericare periodicamente la funzionalità di tutte le parti e
l’integrità prima dell’utilizzo.
La progettazione, i calcoli, l’installazione, il collaudo e la manutenzione di sistemi sospesi o stack audio
professionali deve essere effettuata esclusivamente da personale autorizzato. AEB Industriale non è
responsabile per installazioni improprie, effettuate in assenza dei requisiti di sicurezza.
E’ vietato l’utilizzo delle maniglie per scopi impropri come l’appendimento. E’ inoltre vietato salire sopra al
subwoofer stesso.
Effettuare l’installazione su una supercie piana, in caso contrario è necessario adottare opportuni mezzi di
ssaggio addizionale per evitare ogni pericolo di caduta o ribaltamento.
ATTENZIONE!
20
VIO S218F Cod. 420120416 REV. 1.0
Italiano
1. 2.
3.
Per impilare più subwoofer procedere come segue:
1. appoggiare il subwoofer superiore facendo corrispondere i fori delle staffe con quelle del subwoofer inferiore
2. estrarre verso l’alto le staffe laterali del subwoofer più basso
3. inserire i pin di ssaggio nei fori come mostrato per assicurare i subwoofer. Ripetere la procedura in caso di più
subwoofer
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115

dBTechnologies VIO S218F Le manuel du propriétaire

Taper
Le manuel du propriétaire